Information

Introduction

Technical And Operational Description

Installation

Connectors On Back Cover

Connections

Connection Of Multiple Units

Specifications

Demo Software Instructions

........................................................................................... 1

3

4

8

11

13

16

18

19

...........................................................................................

............................................

...........................................................................................

............................................................

.........................................................................................

............................................................

.....................................................................................

............................................................

FCC COMPLIANCE STATEMENT

This equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference whenthe equipment is operated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, if not installedand used in accordance with the instruction manual, may cause harmfulinterference to radio communication.Operation of this equipment in a residential area is likely to cause harmfulinterference in which case the user will be required to correct the interferenceat his own expense.

Communication Protocol 22...................................................................

Page 3: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

GNETVER 1.2

KEY8

P

RTC VFD4 Digital

TR-550 Series time recorder

TR-550M

GNETVER 1.2

KEY8

P

RTC

TR-550R

GNETVER 1.2

KEY8

P

RTC

TR-550B

GNETVER 1.2

KEY8

P

RTC

TR-550F

RS-232

RS-232

RS-232

MC

RFID

BC

RS-232BC

BEEP

BEEP

BEEP

BEEP

PRINT TESTAUTO

PRINT TESTAUTO

PRINT TESTAUTO

PRINT TESTAUTO

VFD4 Digital

VFD4 Digital

VFD4 Digital

INFO

MACHINE TYPE FUNCTION OPTIONAL

Magnetic Card Reader

RFID Proximity Reader

Barcode Reader

Infrared Barcode Reader

- 1 -

F- MEM512 KB

TIME32

MODEM2400

RS- 485256

F- MEM512 KB

TIME32

RS- 485256

MODEM2400

RS- 485256

MODEM2400

TIME32

F- MEM512 KB

TIME32

F- MEM512 KB

RS- 485256

MODEM2400

Page 4: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Information

Standard Package

Optional

Wall-mounting screw Kit( ASY-M93-1049-18 )

RS-232 Cable( WAS-1436 )

Telephone line( WAS-1438 )

Main unit( TR550X)

Power Adaptor DC12V/120VACor DC12V/230VAC

RS-232 / RS-485 Converter( CON422/485 )

Installation marker( M92-5016 )

( Modem version only )

- 2 -

CD-ROM

Page 5: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

TR-550 Time Recorder is designed for facility access controls , attendancelogging , employee time record tracking and job management and otherapplications.This device utilizes RFID cards or magnetic or barcode card for eachauthorized user seeking access to the facility.

Validates and stores the personal number read from the magnetic card orRFID card or barcode card of the accessing card holder.

Machine ID Address number can be set. Factory preset is "000".

Built-in Modem version is also available.

Can be connected with serial printer directly.

Allows 32 time table for alarm. The longest alarm-on duration is 60 seconds.

Provides RS-232 communication interfaces of remote command programmingand data collection. RS-485 interface is optional.

Up to 255 devices can be connected via RS-232 or RS-485 interfaces.

Magnetic card technology provides reliable and positive identification , yetvery low production cost and repeated usages.

Contain 512 K bytes memory buffer , store up to twenty thousands of recordsfor 10 digits of ID-code.

Provides eight (8) selectable function keys.

Provides drive port for external alarm buzzer connections.

Audio feedback to indicate correct or erroneous card input.

Baud rate are able to be changed if necessary.

Use VFD (Vacuum Fluorescent Display) for clock display.

The VFD provides a wide viewing angle, long life and high display quality.

Wall-mount or desk-top use.

Built-in Real-Time Clock (RTC) module.

Provide two serial port connectors for daisy-chain connection of multi-unitapplications, up to 255 units.

Provide RS-232 communication interface. RS-485 version for long-distanceconnection is also available.

Use non-volatile memory, the memory will never lose when power failure.

- 3 -

Page 6: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Front Panel Controls and Operations

CARDREADER

LED EVENTFUNCTIONINDICATORS

EVENTFUNCTION

KEYS

ERRORINDICATOR

READYINDICATOR

TIMEDISPLAY

READY INDICATORIndicating the time recorder is ready to accept new inputs.

ERROR INDICATORWhen encountering erroneous input, defective card, misread, orincorrectly encoded data, the device will turn on the ERROR indicator andsound 3 beeps.

TIME DISPLAYShows the present time and information.

EVENT FUNCTION KEYSEach of the 8 function keys can be defined to represent a certain eventfunction , e.g., check-in , check-out , overtime , break time , etc … .When activated , the device will store the specific event function code inconjunction with the individual ID code whose card is just being read.

LED FUNCTION INDICATORSIndicating the status of the specific function key, If ON' the function isactive.

CARD READERFollow the graphic for correct card orientation and swipe the cardthrough the entire length of the slot for the magnetic card version andbarcode version, or take the RFID card close to here to read.

- 4 -

Page 7: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Technical And Operational Description

Rear Panel Controls & Power and Interface Connections

MOUNTINGHOLES

RESET

ALARMCONNECTION

NEXTJACK

TELEPHONELINE

HOSTJACK

POWERJACK

HOST JACKFor connection to the host computer or the preceding time recorder unit.

NEXT JACKFor connection to the next time recorder unit.

TELEPHONE LINE JACKFor connection to the telephone line for built-in Modem version.

ALARM CONNECTIONFor connection to the external alarm ring buzzer.

POWER JACKPulg in the power for the time recorder, DC12V.

RESETFor resetting time recorder.

MOUNTING HOLESFor mounting on the wall.

- 5 -

Page 8: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Technical And Operational Description

Display Information

READY

ERROR

READY

ERROR

READY

ERROR

READY

ERROR

SRAM ERROR

FLASH MEMORY ERROR

RECORD FULL

READ CARD ERROR

COMMUNICATION INFORMATION

ADDRESS INFORMATION

When powering TR550, it will self test the SRAMinside the unit. The display will blink this message"SrAM" and beeps if the SRAM is abnormal.

The display will blink this message "FULL" and beepswhen the record data memory is full.

Each record data will be kept into the flash Memoryafter each card reading. If the data can not be keptinto the flash Memory after each card reading, thedisplay will blink this message "FMEM" and beeps.

The display will show "Err" when reading card in error.

At Information mode, it will display the informationyou select to ask. For example, it displays "C103","C1" means this unit is with built-in modem and "03"means the current baud rate is 2400 bps. Please referto the section "Information Mode" for more details.

At information mode, it displays "A005" for example,this means the ID address of this unit isADDRESS=005.

RECORD WILL BE FULLWhen the memory space is about to be full, the"READY" LED will start blinking.

READY

ERROR

READY

ERROR

READY

ERROR

- 6 -

Page 9: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

1. Simultaneously press F2 F3

3. Slide reset switch OFF -> ON -> OFF, the address and baudrate will keep no change, but the CPU will be reset just like restarting the unit by power plug.

Simultaneously press F1 F4F2 F3

KEY

F1

F2

F3

F4

MESSAGE DESCRIPTION

Existing Records Total( in Hexadecimal number )

Usable Memory Size( KBytes in hexadecimal number )

Communication Status And Baud rate*Baud rate code pls refer to“Communication Protocol”

10-1. set Baud rateMachine Address Number

( in Hexadecimal number )

YearMonth / Day

Minute / Second

Exit From Information Mode

DEFAULT

0000 h

01FF h C005 - C0 : Without Modem , 05 : 9600BPS C103 - C1 : Built-in Modem , 03 : 2400BPS

A000 h

XXXXXXXXXXXX

-

Technical And Operational Description

Reset Control

Information Mode

2. Reset from softwareF1 F2 F3 F4

four keys, the unit will be reset and the

Built-in Modem Without Modem00h 00hADDRESS

BAUDRATE 2400bps 9600h

Built-in Modem Without Modem00h 00hADDRESS

BAUDRATE No change No change

ADDRESSBAUDRATE

F1 F2 F3 F4

"ADDRESS" and "BAUDRATE" will become as below :

Built-in ModemNo changeNo change

Without ModemNo changeNo change

four keys to enter"Information Mode". At this time,all LED's will turn OFFand the VFD will display the firmware version of thisunit, such as "1201" which means the firmware versionis V1.2R01. At information mode, press each key to getinformation messages as below:

- 7 -

Page 10: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

1. Use the enclosed mounting accessories.2. Use the enclosed mounting template for the guide to mount the unit on the wall.

1. Use the enclosed WAS-1436 cable.2. Plug the 9pin D-SUB connector into the RS-232 port of the computer and plug another end 8 pin

Phone connector into the HOST jack of TR-550.

1. Mounting

2. Connecting with The Computer

3. Connecting with The External Alarm Bell

4. Connecting with Power Supply

5. Reading a Card and Pushing Buttons

1. Make sure the type of your external alarm bell, N.C. or N.O. type and then connect to the ALARM port on TR-550.2. Make sure the RESET SWITCH must be put at OFF position.

1. Use the power adaptor APR-1014 (for AC 120V) or APR-1015A (for AC 230V).2. Pulg the DC12V into the DC JACK of TR-550.3. Power on TR-550, the unit will make self-test, all

LED's will blink 3 times and buzzer beeps 3 sounds.4. After self-test is successful, the VFD will display time and the READY LED will turn on to be ready for reading a card.

1. When pushing a key button, the corresponding LED will turn on and buzzer beeps.2. If you have set Event Function Time Table, you may also push the key button, but the event function key will get back to the corresponding position preset by the time table after reading a card or in 5 seconds without reading a card.3. The READY LED will go out momentarily when reading a card. The buzzer will beep once and the

READY LED will reappear and the VFD will display the last 4 digits of the card number after reading a card successfully.4. If reading a card in error, the buzzer will beep 2 sounds and the VFD will display "Err".

ISO JIS II

- 8 -

Page 11: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

1. This is an optional feature that TR-550 can also connect with Radio Modem RDL401 (optional item) which can communicate with the computer at about 100 meters without cable installation. Just put one each RDL401 Radio Modem on both the TR-550 end and the computer end.

6. RF Modem ( Optional )

Installation

This is also an optional feature that TR-550 candirectly connect with an RS-232 interface serialPrinter to print out the data.1. You should use a proper serial printer with RS-232 interface and make the connection with TR-550 properly --- connect to TR-550 HOST JACK. See detailled connection at paragraph "Connections " --- Printer.2. Set Printer baud rate to be the same as TR-550 and set printer parameters to be None Parity, 8 Data Bits, 1 Stop Bit and Hardware Flow Control.3. See next paragraph for more information

7. Connect with Serial Printer (Optional )

8. Printer Function

9. Multi-unit Connection - Direct wired

10. Multi-Unit Connection - Modem Remote

See the above paragraph "Connect with Serial Printer".1. Simultaneously press both keys, TR-550 will send all the data in its memory buffer to the printer to print out.2. Simultaneously press both keys and then read the card which you want to print out all the recorded data about this card number, TR-550 will send all the recorded data about this card number to the printer to print out.3. The printer also can print out each record right away after reading a card. Simultaneously press both keys to turn on this function and then press the same both keys again to turn off this function.4. Simultaneously press both keys to stop printing the above Step 1 or Step 2 function during printing.

1. You can make multi-unit connection through RS- 232 port (up to 50 meters maximum) or RS-485 port (up to 1000 meters maximum), and up to 255 units maximum.2. See detailled connection at paragraph "Connection of Multiple Units" --- PC Connect.

1. You also can make a multi-unit connection at remote end by using the first unit with built-in modem, the other units can be without built-in modem.2. See detailled connection at paragraph "Connection of Multiple Units" --- Modem Connect.

F1

F2

F3

F4

F3

PRINT ALL RECORD

PRINT SELECT RECORD

REAL TIME PRINT

STOP PRINT

- 9 -

CANCEL

Page 12: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Installation

1. For the built-in modem version, you can also make a modem network. This means you can connect up to 255 units through telephone lines.2. Each unit is connected with one telephone line through modem port.

11. Modem Network

- 10 -

Page 13: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

HOST

NEXT

CTS123

PIN

CONNECT TO PC / RF MODEM / SERIAL PRINTER

CONNECT TO NEXT TR-550X

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

HOST

CTS123

PIN

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

RS-232

CTS123

PIN

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

RS-485

12345678

NCRS485-

SGRS485+

TXDCTSRXDRTS

PIN FUNCTIONNEXT

12345678

NCRS485-

SGRS485+

TXDCTSRXDRTS

PIN FUNCTIONRS-232

12345678

NCRS485-

SGRS485+

TXDCTSRXDRTS

PIN FUNCTIONRS-485

- 11 -

Page 14: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Connectors On Back Cover

MODEM

ALARM

DC12V

RESET

PIN

NO1COM2NC3

CONNECT TO TELEPHONE LINE

CONNECT TO RING BELL

CONNECT TO DC POWER

DC 12V 10% / 500mA

RESET

ON

OFF

RESET

ON

OFF

RESET ON RESET OFF

RESET TR-550X BY HARDWARE

NO :COM :

NC :

123456

NCNCTIP

RINGNCNC

FUNCTIONMODEM

PIN FUNCTIONALARM

Normal OpenCommonNormal Close

- 12 -

Page 15: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

PC

CTS123

PIN

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

HOST

DCDPIN

123456789

RXDTXDDTRSG

DSRRTSCTSRI

PCFUNCTION

24613

CONNECT

23578

1. RS - 232 CONNECT

2. RS - 485 CONNECT

CTS123

PIN

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

HOST

RS485+RS485-

PCFUNCTION

57

CONNECT

RS485+RS485-

3. CABLE ( WAS-1436 )PLUGDB9

PIN123

PIN

45678

WIRE

GRAYORANGEBLACK

COLOR

REDGREEN

YELLOWBLUE

BROWN

7283

NC5

NCNC

PLUGDB9

1

8

PERSIONAL

COMPUTER

- 13 -

Page 16: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

RF

MODEM

Connections

TIPRING

TELEPHONE LINE

34

CONNECTMODEM

TIPRING

LINE

1. TELEPHONE LINE CONNECT

MODE

TELEPHONELAN

PIN123456

NCNCTIP

RINGNCNC

FUNCTIONMODEM

FUNCTION

RF MODEM

CTS123

PIN

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

HOST

DCDPIN

123456789

RXDTXD

DTRSG

DSR

RTSCTS

RI

RF MODEMFUNCTION

42631

CONNECT

HOST

23578

RFMODEM

1. RF MODEM CONNECT ( Optional RDL-401 )

MODEM

1

6

6

1

2. CABLE ( WAS-1438 ) PLUGPLUGPIN

45

PINWIRE

GREENYELLOW

COLOR

45

23

BLACKRED

23

1NC1

6NC6

- 14 -

Page 17: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Connections

PRINTER

CTS123

PIN

45678

FUNCTION

TXDRTSRXD

RS485+SG

RS485-NC

HOST

DCDPIN

123456789

RXDTXD

DTRSG

DSR

RTSCTS

RI

SERIAL PRINTERFUNCTION

42631

CONNECT

HOST

2

SERIALPRINTER

1. SERIAL PRINTER CONNECT

SERIAL PRINTER

3578

CABLE ( WAS-1432 )PLUGPLUG

PIN

67

PINWIRE

BLACKORANGE

COLOR

32

45GREEN

RED54

3

YELLOW

6

8

GRAY

1

1

81

82

BLUE

71

BROWN

8

SCABBLE CABLE ( WAS-1436 ) FOR RS-485 COMMUNICATION

1

8

1

8

PIN 5GREEN

PIN 7BLUE

STEP 1

STEP 2

STEP 3

CUT

CON485

RS-485/RS-232 Converter ( Optional )

- 15 -

GREEN

BLUE

1

8

RS485-

RS485+

Page 18: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

PC

WAS-1436 WAS-1432 WAS-1432

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NCRS485-

SG

RS485+TXDCTSRXD

RTSCTS

TXDRTSRXD

RS485+

SGRS485-

NC

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NCRS485-

SG

RS485+TXDCTSRXD

RTSCTS

TXDRTSRXD

RS485+

SGRS485-

NC

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NCRS485-

SG

RS485+TXDCTSRXDRTSCTS

TXDRTSRXD

RS485+

SGRS485-

NC

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NCRS485-

SG

RS485+TXDCTSRXDRTSCTS

TXDRTSRXD

RS485+

SGRS485-

NC

01 02 03

02 03

02 03

PC

1

2

3

4

5

6

7

8

9

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NCRS485-

SG

RS485+TXDCTSRXD

RTSCTS

TXDRTSRXD

RS485+

SGRS485-

NC

01

PC

RS485+RS485-

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NCRS485-

SG

RS485+TXDCTSRXDRTSCTS

TXDRTSRXD

RS485+

SGRS485-

NC

01

DB9

RS232-485

DCD

RXD

TXD

DTR

SG

DSR

RTS

CTS

RI

PC Connect

1. RS-232 Interface

2. RS-485 Interface

PC

Communication Multiple Connect

- 16 -

Page 19: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

MODEM

Connection Of Multiple Units

PC

WAS-1438 WAS-1432 WAS-1432

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NC

RS485-SG

RS485+TXD

CTSRXDRTSCTS

TXDRTS

RXDRS485+

SGRS485-

NC

1

HOST NEXT

2

3

4

5

6

7

8 1

2

3

4

5

6

7

8

NC

RS485-SG

RS485+TXD

CTSRXDRTSCTS

TXDRTS

RXDRS485+

SGRS485-

NC

01 02 03

02 03PC

1

MODEM NEXT

2

3

4

5

6

1

2

3

4

5

6

7

8

NC

RS485-SG

RS485+TXD

CTSRXDRTSNC

NCTIP

RINGNCNC

01TEL. LINE

RINGTIP

Modem Connect

1. MODEM / RS-232 Interface

PC

Communication Multiple Connect

TELLAN

TELLAN

MODEM

Note:For remote Modem multi-unit Connection, the 1st unit should be with built-inmodem which can connect to TEL LAN ( telephone line ) and the rest of unitscan be without modem.

- 17 -

Page 20: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

GNETVER 1.2

VFD4 Digital

RS-232

RFID

Magnetic Card : TR-550M

Barcode Card : TR-550B

RFID Proximity Card : TR-550R

Communication Interface :

MC

RTC

BC

PRINT

BC

Memory Size for Storing Data :

Clock :

Display :

Power Supply :

Dimensions :

Mounting :

Environment :

Relay Contact Capacity for ALARM :

Barcode Card : TR-550F

ISO Track 2 , 75 BPI

Code 39 , Numeric Codes Only

Code 39 , Numeric Codes Only

125 KHZ , ASK , 64 Bits , Manchester Coding

RS232 , Full-Duplex , 8N1 , 2400 - 19200 bps

Communication Interface :RS485 , Half-Duplex , 8N1 , 2400 - 19200 bps

Communication Interface :2400 bps Modem , CCITT V.22bis , V.22 , Bell 212 , and Bell 103

Printer Interface :Serial Printer , RS232 , 8N1 , 2400 - 19200 bps

CMOS SuperFlash * EEPROM 512K bytes

* SuperFlash is a registered trademark of Silicon Storage Technology, Inc.

R

Real Time Clock (RTC) module with built-in 10 year battery

Vacuum Fluorescent Display , 4 Digits

Communication protocol :GIGA-TMS Net Version 1.2 ( GNET V1.2 )

ACDC DC 12V , 500mA

W 192 x H 120 x D 52 mm

%C/F

Operating Temp : 0 ~ 55 Deg.CStorage Temp : -10 ~ 55 Deg.CHumidity : 10 ~ 90 % relative

Wall-mounting or Desk-top

AC 120V / 1A , DC 24V / 1A

- 18 -

RS- 485256

MODEM2400

F- MEM512 KB

Page 21: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

1. Installing the Demo Software1. Use the enclosed DISK5039 CD-ROM to put into the CD-ROM drive disk of your computer.2. The setup program will automatically start software installation at WIN98.3. Please follow the instruction on the screen, step by step to install the software.

1. Run "TR550" Demo Software.2. The screen will display the Password Input dialog box.3. At the first time, input the preset default password "0000" and then click OK.4. After password input is correct, it will show the

Main Menu TR550-Express.4. At "Settings" dialog box, you may select "New Password" to change password if you wish.

1. At "Settings" dialog box, first of all, you must select the COM port through which you connect TR-550 to the computer, such as "COM1" and select "Use RS-485" if you are connecting RS-485.2. Make sure TR-550 has been connected to the computer properly and turn it on, then click "AutoScan" to get hand-shaking with TR-550.3. After the hand-shaking between TR-550 and the Computer is successful, all the features at "Setting" dialog box will become active. But the "Dial" feature will not be active until Phone Number is input.

The default Baud Rate of the version with built-inModem is 2400 bps, without Modem is 9600 bps. Youmay change Baud Rate as below: a. Click at Baud Rate box to select 2400, 4800, 9600 or 19200 bps. b. Click "AutoScan" to set the new Baud Rate to TR-550. During scanning, "Status" will change momentarily. After Bate Rate setting is successful, the "status" will show "Successful".4. Click "SET ID" to set new Machine Address ID number ( Default : 000 ) from 001 to 255.

Before you set ID for the next unit, you must"Add" the new ID number onto the "Device List" and"Device Name" at "Settings" dialog box.a. Click "Add" to add the new ID number onto the "Device List" or click "Delete" to delete the ID number from the "Device List".b. You can change the "Device Name" for the unit at the "Device Name" box.

3. Set Parameters

2. Input Password

REMARKS

REMARKS

- 19 -

Page 22: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

5. Click "SET TIME" to set Date/Time to TR-550. The screen will show "Setting Date & Time" dialog box.

a. Click to select Month/Year.b. Directly click the Day on the screen calendar to

select Date. c. Click to select Hour/Minute/Second. d. Then click OK to set Date & Time to TR-550. e. If you want just to use the Date & Time of your computer for setting to TR-550, at "Setting Date & Time" dialog box, just click "Reset" and "OK".6. At "Settings" dialog box, click "Reset" to reset the TR-550. This will reset the Machine Address ID number of TR-550 to become default : 000, other keep no change.7. Click "New Password" to Change Password .

Demo Software Instructions

4. Event Table 1. Click "Event Table" to enter "Event Table" dialog box.2. You may select "Use Time Table" or "Manual Mode" to control Event Function Keys.3. At "Manual Mode", you should press Event Function keys on the unit manually.4. At "Use Time Table" mode, you should establish a time table to download to TR-550. Then the Event Function Keys will be controlled by the preset time table. You may set maximum 8 event time. a. "Upload" means Get the existing Time Table from TR-550. b. "Download" means Set time Table to TR-550. After you have established a time table, you should click this "Download" to set the time table to TR-550. c. "Load" means Load Time Table from File saved previously. You may edit this old file. d. "Save" means Save Time Table to File for future use.

5. Ring Table1. Click "Ring Table" to enter "Ring Table" dialog box.2. At "Ring Table" you may establish maximum 32 alarm time to activate the ALARM Drive for turning on the external alarm bell. a. "Upload" means Get the existing Ring Table from TR-550. b. "Download" means Download the the Ring Table to TR-550. After you have established a ring table, you should click this "Download" to set the ring table to TR-550. c. "Load" means Read Ring Table from the File saved previously and you may edit this old file to make what you want. d. "Save" means Save Ring Table to File for future use.

- 20 -

Page 23: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

6. Record

8. Built-in Modem Version

1. Click "Record" to enter "Record" dialog box.2. Click "Upload" to upload the records from TR-550.3. You may select the item(Card NO., On duty, Date or Time) you want and use "Ascending" or "Descending" to arrange the records in order before "save record to file".4. Click "Save" to save the records to the file. The records will disapper from the display after "Save record to file" is complete and the record data will be cleared from TR-550 memory buffer.5. Click "Load" to open the file saved previously.

1. Built-in Modem Version can be a remote unit which can be polled and accessed by the Main Computer through the normal telephoneline with modem.2. Use the enclosed phone cable to connect TR-550 to the telephone line--plug one end of the phone cable into the MODEM jack on TR-550 and plug another end of the phone cable into the telephone line jack.3. At Main Computer side, the computer must be connected with a regular modem which is connected to the normal telephone line. a. Run the TR-550 Demo Software . b. At "Settings" dialog box, 1.) You must select the ID number of the Remote unit from the "Device List" which you want to poll and access.If no Remote unit ID number on the "Device List", you must add it. 2.) Enter the "Phone Number" on which the Remote unit is connected. 3.) Select the COM port on which you connect the regular modem with the Computer. 4.) The "Dial" icon button should be activated after Phone Number is input.Click "Dial" to dial the Remote unit. The "Status" will show "Connect" or "LOGIN" after the connection is successful, otherwise it will show "BUSY" or "NO CARRIER".Note: The baud Rate of the Remote unit,which is with built-in Modem,must be set to 2400 bps.

Demo Software Instructions

- 21 -

A function of card validation is provided by setting theprefix of card number. The reader will check the cardsread and only accept and record the cards matchingto the pre-set prefix.1. Click "Other Options" to set the prefix table.2. Click "Primary" and “Secondary” to set the required checking code. You can set up to 31 groups of Secondary code.

Note : “Primary” means to check the first 2 digits of card number.

“Secondary” means to check the 3th and 4th digit of card number.3. Click “Download” to set the prefix table to TR550.4. Click “Upload” to get the existing prefix table from TR550.

7. Other Options

Page 24: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

ACK

TX1

ACK

RX

NACK

TX2 TX4RX

RXERR

TIMEOUT

RX1 RX2

RX

NORX4

TX3

WAITRXACK

RX

NACK TIME OUT

Support TTY (TELE TYPE) OPERATION - Use TTY to send commands and messages.

NACK

TX3

RX3

NACK

GNET FEATURES

Simple handshaking - One enquiry one answer back.

Multi-link capability

Expandability - GNET provides 4 major functions:

1. POLLING2. LOGIN / LOGOUT3. DATABASE4. INFORMATIONAlso can be expandable.

Simple format Use ASCII value for each field and use Separator "," between two Fields.

GNET Handshaking

- 22 -

Page 25: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

STX CMD CONTENTS CHKSUM CR

GNET PACKET

STXCMD

CONTENTSCHKSUM

CR

2 ^B Start of Text02

STX REPLY CONTENTS CHKSUM CR

ITEM Dec Control Key FunctionHex

13 ^M Carriage Return0d

Ascii Ascii Command CodeAsciiAscii Ascii Contents DataAsciiAscii Ascii Check SumAscii

REPLY (78) 65 (N) A (Negative) Acknowledge(4e) 41

Command Index Table

POLLING

LOGIN/OUT

SETTING

Topic

DATABASE

CommandD

O

IL

P

TS

FR

NGE

CB

AddressContents

-

AddressPassword

Password

-Date+Time

--

-Number

-

Number+Param+ChkSumNumber

Polling Designated MachineDescription

Logout

Set New Machine IDLogin

Set New Password

Get Date and TimeSet Date and Time

Get Product VersionReset Machine

Get Number Of RecordRead Record By Number

Erase All Record

Set Register by NumberGet Register by Number

- 23 -

Page 26: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

Reply Index Table

ACKNAK

Topic ReplyAN

Reply InformationContents

See Error Index TableACK+Information

Description

NAK+Information

Error Index Table ( For Reply NAK )

ACCESS LEVEL

COMMAND CODE

Topic Error Index0001

Access Denied or Password ErrorDescription

Command packet is too long

DATABASE

FILE

0203

Command packet is emptyCommand code is out of range

0405

Illegal Command or DataDatabase and Register is Empty

06 Record number is out of range0708

Check Sum ErrorMemory Not Enough

0A File Not Exist

Note

- 24 -

Page 27: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

1. POLLING ADDRESS :

ADR1STX D CR

2. SET NEW ADDRESS :

ADRSTX A CR, ST1 , PD , ST2

0002 D 0d

Polling Broadcast : 00hReply Address =01 , Login Status , Product Name = TR550 , Record Level = 0

EXAMPLE

0102 A , TR550LOGIN , 0d0,

ADRSTX I CR

STX A CR

0502 I 0d

Set New Address : 05h

ADR New Address

02 A 0d

ST2

EXAMPLE

Login / LogoutProduct NameRecord Level

Polling Address , 00 = BroadcastST1PDST2

ADR1

01 - 8

9

Record EmptyRecord LevelRecord Full

3. LOGIN :

PASSWORDSTX L CR

STX A CR

PASSWORD 4 CHARACTERS FOR LOGIN . 0000 = Initial Value

00h ( 000 )

- 25 -

Page 28: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

4. LOGOUT :

000002 L 0d

Login Password : 0000h

02 A 0d

STX O CR

STX A CR

02 O 0d

Logout

02 A 0d

EXAMPLE

EXAMPLE

5. SET PASSWORD:

PASSWORDSTX P CR

STX A CR

PASSWORDCHKSUM

New Four Digit PasswordThe SUM of all Character Between the STX and the CHKSUM

CHKSUM

123402 P 0d

Set New Password : 1234h

02 A 0d

1A

EXAMPLE

Check Sum : P+1+2+3+4 = 50h+31h+32h+33h+34h = 11Ah => 1A

0000

- 26 -

Page 29: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

6. SET DATE AND TIME :

STX S CR

STX A CR

02 S 0d

Set Date = 1999 / 9 / 15Set Time = 12 : 30 : 00

02 A 0d

YYYYMMDDhhmmss

19990915123000

EXAMPLE

YYYYMMDDhhmmss

7. GET DATE AND TIME:

STX T CR

STX A CR

02 T 0d

Get Date : 1999 / 12 / 1

02 A 0d

EXAMPLE

Get Time : 14 : 20 : 31

YYYYMMDDhhmmss

19991201142031

8. GET PRODUCT VERSION :

STX F CR

STX A CR

VxxRmm , Vxx : Firmware Version X.X , Rmm : Modify mm TimesVERSION

VERSION

Year (1980 - 20xx )Month (01 - 12 )Date ( 01 - 31 )Hour ( 00 - 23 )

Mintue ( 00 - 59 )Second ( 00 - 59 )

- 27 -

Page 30: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

02 F 0d

Firmware Version = 1.1Modify times = 1

02 A 0dV1.1R01

EXAMPLE

9. RESET :

STX R CR

STX A CR

02 R 0d

TR-550 is Reset

02 A 0d

EXAMPLE

Address = 00h , Password = 0000 ( TR-550 internal password, not on Demo software )

10. SET REGISTER :

STX C CR

STX A CR

REGSTER

REGSTER , PARAM CHKSUM

PARAMRegister Address . 2 Bytes Width ( 00h ~ FFh )Set Parameters of Register

10-1. SET BAUDRATE :

STX C CR

STX A CR

00 , BPS CHKSUM

BPS"3""4"

2400 bps4800 bps

"5""6"

9600 bps19200 bps

- 28 -

Page 31: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

02 C 0d

Write to Parameter Table Address : 00 hSetup Communication Baudrate : 19200 bps

02 A 0d

EXAMPLE

00 , 6 05

10-2. SET MANUAL / TIME TABLE FOR EVENT FUNCTION KEYS

STX C CR

STX A CR

01 , M/T CHKSUM

M/TMT

MANUAL MODEUSE TIME TABLE

02 C 0d

Write to Parameter Table Address : 01 hUse Time Table

02 A 0d

EXAMPLE

01 , T 24

10-3. SET FUNCTION KEY/LED LOCATION

STX C CR

STX A CR

02 , FK CHKSUM

FK"0""1"

LED1LED2

"4""5"

LED5LED6

"2""3"

LED3LED4

"6""7"

LED7LED8

F1 F2 F3 F4

LED1 LED2 LED3 LED4

LED5 LED6 LED7 LED8

Modem : 2400Non- modem : 9600

Manual Mode

- 29 -

Page 32: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

02 C 0d

Write to Parameter Table Address : 02 hAssignment Key/Led Local : LED7

02 A 0d

EXAMPLE

02 , 6 07

10-4. SET FUNCTION KEY :

STX C CR

STX A CR

30-37 , HR CHKSUM

ADR3031

01

02 C 0d

Write to Parameter Table Address : 30 hLED3 on Action Time = 13 : 30

02 A 0d

EXAMPLE

30 , 24

3233

23

3435

45

3637

67

MIN F1 F2 F3 F4

HR00 - 23

MIN00 - 59

F2 - F4None

F1"0" LED1 "4""1" LED2 "5""2" LED3 "6""3" LED4 "7"

CHKSUMC+...+F3+F4

LED5LED6LED7LED8

13 30 2 0 0 0

10-5. SET RING TABLE :

STX C CR

STX A CR

80-9F , WK CHKSUMHR MIN SEC

- 30 -

Page 33: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

ADR8081

01

02 C 0d

Write to Parameter Table Address : 80 h Ring Relay ON Action Week : Monday - Sunday (Everyday)

Ring StartsTime : 13 : 30 Ring Duration : 5 Seconds ( Alarm keeps ringing for 5 seconds.)

02 A 0d

EXAMPLE

80 , 33

8283

23

8485

45

:9D

:29

WK"0"

0 13 30 05

9E 309F 31

MOM - SUNHR

00 - 23

MIN00 - 59

SEC00 - 59

CHKSUMC+...+MIN+SEC

"1" MOM"2" TUE"3" WED"4" THU"5" FRI"6" SAT"7" SUN"8" MON - FRI"9" SAT - SUN

11. GET REGISTER :

STX B CR

STX A CR

REGSTER

REGSTER

PARAMRegister Address . 2 Bytes Width ( 00h ~ FFh )Get Param of Register

11-1. GET BAUDRATE :

STX B CR

STX A CR

00

BPS CHKSUM

PARAM CHKSUM

* Same 10-1. SET BAUDRATE

02 B 0d

Get Parameter From Parameter Table Address : 00 hGer Communication Baudrate : 2400 bps

02 A 0d

EXAMPLE

00

3 74

- 31 -

Page 34: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

11-2. GET MANUAL / TIME TABLE AND FUNCTION KEY LOCATION :

STX B CR

STX A CR

01

M/T CHKSUM

* Same 10-2 , 10-3 .

02 B 0d

Get Parameter From Parameter Table Address : 01 hGet Function Key Action : Manual ModeGet Function Key Location : LED 5

02 A 0d

EXAMPLE

01

M C2

FK

4

11-3. GET FUNCTION KEY :

STX B CR30 - 37

* Same 10-4

02 B 0d

Get Parameter From Parameter Table Address : 35 hGet LED6 ON Active Time : 18 : 30

EXAMPLE

35

STX A CR30-37 , HR CHKSUMMIN F1 F2 F3 F4

02 A 0d35 , 6618 30 5 0 0 0

11-4. GET RING TABLE :

STX B CR80 - 9F

* Same 10-5

STX A CR80 - 9F , WK CHKSUMHR MIN SEC

- 32 -

Page 35: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

02 A 0d

Get Parameter From Parameter Table Address : 9E hRing Relay ON Action Week : Monday - Friday

Time : 08 : 00 Ring Duration : 5 Seconds

02 B 0d

EXAMPLE

9E , 508 08 00 05

9E

12. GET NUMBER OF RECORD :

STX N CR

STX A CR

02 N 0d

The Total of Record Count : 12

02 A 0d

EXAMPLE

NUMBER

000C

CHKSUM

NUMBER Record Count . 4 Bytes Width ( 0000h ~ FFFFh )

14

13. READ RECORD BY NUMBER :

STX G CR

STX A CR

02 G 0d

Read Record Number : 12Card ID : 1001 , Function Key : 2 , Date : 1999/09/08 , Time : 12:44

02 A 0d

EXAMPLE

NUMBER

000B

CHKSUM

NUMBER Record Count . 4 Bytes Width ( 0000h ~ FFFFh )

C7

NUMBER

DATA,

DATA Record Data ( Card ID , FUN , DATE , TIME )

000B

, 1001 , 2 , ,1999/09/08 12:44

- 33 -

Page 36: Information · TR-550 Time Recorder is designed for facility access controls , attendance logging , employee time record tracking and job management and other applications. This device

Communication Protocol

14. ERASE ALL RECORD :

STX E CR

STX A CR

02 E 0d

ERASE ALL RECORD

02 A 0d

EXAMPLE

Note