TPR 280, 80 °C, DN 16 ISO-KF
Flange size: DN 16 ISO-KF
For general vacuum applications
Compact and rugged
Maximum pressure refers to inert gases
Similar Image
Dimensions
Technical Data TPR 280, 80 °C, DN 16 ISO-KF
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 ISO-KFOutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 280, 80 °C, DN 16 ISO-KF
Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. ≤ 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 1.5 cm³Weight 80 g
Order number
TPR 280 PT R26 950
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -TVacuum accessoriesCentering ring with metal mesh-fine filter,pore size 4 m, FPM/stainless steel PT 120 132 -TCentering ring with protection filter,pore size 20 m, FPM/stainless steel PF 117 216 -T
www.pfeiffer-vacuum.com Page 3
TPR 280, 80 °C, DN 16 CF-R
Flange size: DN 16 CF-R
For general vacuum applications
Compact and rugged
Maximum pressure refers to inert gases
Similar Image
Dimensions
Technical Data TPR 280, 80 °C, DN 16 CF-R
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 CF-ROutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 280, 80 °C, DN 16 CF-R
Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 1.5 cm³Weight 100 g
Order number
TPR 280 PT R26 951
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T
www.pfeiffer-vacuum.com Page 3
TPR 280, 80 °C, 8 VCR
Flange size: DN 8 VCR
Maximum pressure refers to inert gases
Compact and rugged
For general vacuum applications
Similar Image
Dimensions
Technical Data TPR 280, 80 °C, 8 VCR
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealed
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 280, 80 °C, 8 VCR
Feedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter 8 VCROutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 2 cm³Weight 130 g
Order number
TPR 280 PT R26 953
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T
www.pfeiffer-vacuum.com Page 3
TPR 280, 80 °C, 1/8" NPT
Maximum pressure refers to inert gases
Compact and rugged
Fast, stable measurement
Similar Image
Dimensions
Technical Data TPR 280, 80 °C, 1/8" NPT
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter 1/8" NPT
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 280, 80 °C, 1/8" NPT
Output signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 2 cm³Weight 70 g
Order number
TPR 280 PT R26 952
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T
www.pfeiffer-vacuum.com Page 3
TPR 280, 250 °C, DN 16 ISO-KF
Flange size: DN 16 ISO-KF
Maximum pressure refers to inert gases
Compact and rugged
For general vacuum applications
Similar Image
Dimensions
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 280, 250 °C, DN 16 ISO-KF
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 250 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 ISO-KFOutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 10 cm³Weight 130 g
Order number
TPR 280 PT R26 960
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -TTPR 280 PiraniTPR 280, 80 °C, DN 16 ISO-KF PT R26 950Vacuum accessoriesCentering ring with metal mesh-fine filter,pore size 4 m, FPM/stainless steel PT 120 132 -TCentering ring with protection filter,pore size 20 m, FPM/stainless steel PF 117 216 -T
www.pfeiffer-vacuum.com Page 3
TPR 280, 250 °C, DN 16 CF-R
Flange size: DN 16 CF-R
Maximum pressure refers to inert gases
Compact and rugged
For general vacuum applications
Similar Image
Dimensions
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 280, 250 °C, DN 16 CF-R
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 250 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 CF-ROutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 10 cm³Weight 140 g
Order number
TPR 280 PT R26 961
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T
www.pfeiffer-vacuum.com Page 3