TL6020 - Data SheetDual Camera synchronous Video Switcher with Image Processor
TL6020 - Features+ Dual FCB-H11/H10 camera input interfaces
+ Frame synchronous switching between inputs (no output sync interrupts)
+ Integrated image processor (picture in picture or image flipping)
+ PIP size selectable 1/2, 1/4, 1/8, 1/16 of full image size
+ HD-SDI (SMPTE292M) or YPbPr/RGB analog output
+ Sync on Y/G in case of analog output
+ 1080i/50Hz, 1080i/59.94Hz, 720p/50Hz and 720p/59.94Hz outputs
+ Full digital signal processing chain for best image quality
+ Serial control of TL6020 and cameras via RS232 interface (Sony VISCA protocol support)
+ Single power input for camera and module
+ Supply voltage requirements: 7V to 12V DC regulated
+ Tiny module size 50mm x 50mm (width x height)
+ Cable kit included
Block Diagram TL6020Order Codes:
TL6020
TL6020-F Image flip function (no PIP)
TL6020CK Cable kit
SAFETY NOTE:
FFCs with contacts on opposite sides MUST be used with TL6020 when interfacing to Sony FCB-H11/H10 cameras.
Data_LVDS
Clk_LVDS
DESER
SYNCHRONIZER
PIP SCALER
DATA FORMATTER
ENCODER
CPU
RS232Rx Tx
CAMERA 1(J4)
VIDEOENCODER
Cable Conn.(J5)
YsPBPR OUTPUT(J7)
Data_LVDS
Clk_LVDS
RS422Rx Tx
Cam 1(J1)
CAMERA 2(J6)
SDRAM
JUMPERJ1-2J3-4J5-6
CAMERA SELECTUNIT
SERIALIZERHD-SDI OUTPUT
(J8)
Cable Conn.
Thunder Link is a family of small form factor modules for formatting and converting generic digital video streams to standard compliant formats. Different interface standards are supported from the transmitter side including DVI/HDMI, VGA, HD-SDI, SDI and USB.
The modules connect to the digital video interface of Sony’s FCB-H, FCB-EH and FCB-EX-E block cameras and support several progressive and interlace HDTV or SDTV formats. As no analog to digital conversion is done on these modules, best output image quality is guaranteed.
1
Preliminary Data
A1_DS_TL6020_V.3.1.0.fm March, 9th, 2012
Cam 2(J2)
ONBOARDPOWER
12V DC inputONBOARD DC SUPPLY VOLTAGES
Cable Conn.(J3)
Internet: www.aivion.comE-Mail: [email protected] 2
TL6020 - Data SheetDual Camera synchronous Video Switcher with Image Processor
Preliminary Data
A1_DS_TL6020_V.3.1.0.fm © 2008-2012 Visual Communication Systems GmbH, all rights reserved.
Specification INPUTS:CAMERA DATA* 4 LINK LVDSCAMERA CLOCK* LVDSCONTROL Rx (RS232 Level)
OUTPUTS:CONTROL Tx (RS232 Level)HD-SDI VIDEO 1080i or 720p, 59.94Hz or 50HzSMPTE292M, SMPTE274 and SMPTE296M compliantAnalog Y, Pb, Pr / Trilevel Sync on Y orAnalog R, G, B / Trilevel Sync on GY(G) output level 1Vpp into 75 ohmsPb(B) output level 0.7Vpp into 75 ohmsPr(R) output level 0.7Vpp into 75 ohms
POWER INPUT:7V TO 12V regulated (12V recommended),<14 Watts (FOR BOTH, 2x FCB-H11 CAMERAS AND TL6020 MODULE)
MECHANICAL:WIDTH = 50mmHEIGHT = 50mmTHICKNESS PCB = 1.6mmCOMPONENT HEIGHT (TOP/BOT) = 11mm/5mm
CABLES:0.5 mm FFC with contacts on OPPOSITE sides MUST be used (supplied with FCB-H11)Micro coaxial cable is KEL SSL20-10SSB-xxx-B type (xxx=length in cm)Connectors J3: WUERTH** 620 002 113 322, Crimp Contact 620 001 137 22Connectors J5, J7: JST SHR-08V-S, Crimp Contact SSH-003T-P0.2-H
Notes:* Applies for both camera inerfaces. Cameras MUST be set to same video standard.** For J3 also possible: JST PHR-2, Crimp Contact SPH-002T-P0.5-L
Typical Application
PIP Application Example.Camera 1 captures overview and camera 2 operates with optical zoom providing a detailed view on any region of interest.Note:For TL6020-F, the PIP function is replaced by the image flip feature. In this case both camera pictures can be flipped independently in horizontal and vertical direction.
Connectors OverviewPCB TOP SIDE:J3 Power inputJ5 RS232 Host control IFJ7 Analog video outputJ8 HD-SDI video output
PCB BOTTOM SIDE:J1 Camera 1 power and control IFJ2 Camera 2 power and control IFJ4 Camera 1 LVDS video IFJ6 Camera 2 LVDS video IF
J7
J3
J5
J8
J2 J1
J4J6
Internet: www.aivion.comE-Mail: [email protected] 3
TL6020 - Data SheetDual Camera synchronous Video Switcher with Image Processor
Preliminary Data
A1_DS_TL6020_V.3.1.0.fm © 2008-2012 Visual Communication Systems GmbH, all rights reserved.
Onboard Connector Pin AssignmentsBoard-to-wire connectors:
Power input, JST PH Series
Control Interfaces, JST SH, 8 pin
Note: RS422 interface operation requires dedicated software. It can not be selected by jumpers. Contact to [email protected].
REFDES PIN# SIGNAL
J3 1 P12V_IN
2 GND
REFDES PIN# SIGNAL
J5 1 RXD-FPGA (RS232)
2 TXD-FPGA (RS232)
3 GND
4 GND
5 NC (TXD_422_P)
6 NC (TXD_422_N)
7 NC (RXD_422_N)
8 NC (RXD_422_P)
Analog video output, JST SH, 8 pin
JP1 Jumper Settings - TL6020 configuration
REFDES PIN# SIGNAL
J7 1 Y_OUT (sync on Y)
2 GND
3 PB_OUT
4 GND
5 PR_OUT
6 GND
7 NC, do NOT connect
8 NC, do NOT connect
Pins 1-2 Pins 3-4 Camera Select Mode Pins 5-6 Active Video Output
OPEN OPEN Camera select by software OPEN HD-SDI
CLOSED OPEN Camera 1 selected CLOSED Analog YPbPr
OPEN CLOSED Camera 2 selected
CLOSED CLOSED Reserved
Four mounting holes (blue), 2.5mm diameter
Internet: www.aivion.comE-Mail: [email protected] 4
TL6020 - Data SheetDual Camera synchronous Video Switcher with Image Processor
Preliminary Data
A1_DS_TL6020_V.3.1.0.fm © 2008-2012 Visual Communication Systems GmbH, all rights reserved.
Board Operation Remote Protocol Notes:
1. Protocol does not depend on physical layer of remote control interface (independent of RS232 / RS422 selection)
2. Baudrate is set to 38.4kbps, 8 data bits, no parity, 1 stop bit (8N1 terminal setting)
3. Transmission of a byte starts with start bit followed by the lsb
4. Protocol is subset of SONY VISCA protocol. The camera select unit has VISCA device address 7 (seven) assigned. Traffic carrying other addresses is not processed and not acknowledged by the camera select unit. Such bytes are directly transferred to the selected camera.
5. When accessing cameras with dedicated addresses, address 7 cannot be used. Address coding of cameras is basically not required because camera control lines are actively switched by selecting the desired camera as signal output.
6. Actual implementation supports the following command codes:
See separate table.
7. Received commands are acknowledged by the camera select unit. Acknowlewdge code is always F0 41 FF.
8. Acknowledge is always followed by a completion code. Completion code is always F0 51 FF.
9. General protocol timing (on command level) is given within the VISCA protocol specification issued by SONY.
10. When using the Windows based control software from SONY, the camera select unit can be controlled by typing the command codes directly into the "Direct Command" box in the bottom right corner.
Remote Protocol:
Internet: www.aivion.comE-Mail: [email protected] 5
TL6020 - Data SheetDual Camera synchronous Video Switcher with Image Processor
Preliminary Data
A1_DS_TL6020_V.3.1.0.fm © 2008-2012 Visual Communication Systems GmbH, all rights reserved.
Board OperationREMOTE PROTOCOL COMMAND CODES AND PARAMETERS:
Note: Both cameras MUST be set to same video standard.
SOURCE SELECT:
IMAGE FLIP CONTROL (TL6020-F only):
Command Describtion
87x0 FF Camera 1 as direct output
87x1 FF Camera 2 as output (synchronized and processed)
87x2 FF Camera 1 as output (image captured and processed)
87xF FF for selecting color bar as output, YPbPr
x=0 Analog video output as YPbPr
x=1 Analog video output as RGB
Command Describtion
87 A0 FF All image flip functions OFF
87 A1 FF All image flip functions ON (both images are flipped in horizontal and vertical direction)
87 A2 FF Camera 1, H-flip OFF
87 A3 FF Camera 1, H-flip ON
87 A4 FF Camera 2, H-flip OFF
87 A5 FF Camera 2, H-flip ON
87 A6 FF Camera 1, V-flip OFF
87 A7 FF Camera 1, V-flip ON
87 A8 FF Camera 2, V-flip OFF
87 A9 FF Camera 2, V-flip ON
PIP PARAMETER RANGES:
PIP Window Positioning (table shows hexadecimal values):
Notes:
1. PIP window size can be changed only if PIP scaler is OFF. If PIP scaler is switched ON, window size is adjusted automatically.
2. PIP frame color cannot be changed. It is set due to the actual video standard.
Green = 1080i / 59.94Hz
Blue = 720p / 59.94Hz
Cyan = 1080i / 50Hz
Magenta = 720p / 50Hz
Position Parameter sx sy
Video Standard min max min max
1080i 0x0 0x59 0x0 0x21
720p 0x0 0x4F 0x0 0x2C
PIP CONTROL (TL6020 only):
PICTURE FREEZE CONTROL:
Command Describtion
87 80 FF PIP mode OFF
87 81 FF PIP mode ON
87 82 FF Reserved Code, do not use
87 83 sx FF PIP window x size, 8 pixel steps, sx is 8bit hex number for size
87 84 sy FF PIP window y size, 8 line steps, sy is 8bit hex number for size
87 85 px FF PIP window x position, 8 pixel steps, px is 8bit hex number for position
87 86 py FF PIP window y position, 8 line steps, py is 8bit hex number for position
87 90 FF PIP scaler OFF
87 91 FF PIP scaler ON, scale 1/2
87 92 FF PIP scaler ON, scale 1/4
87 93 FF PIP scaler ON, scale 1/8
87 94 FF PIP scaler ON, scale 1/16
87 95 FF Reserved Code, do not use
Command Describtion
87 AC FF Camera1, freeze OFF
87 AD FF Camera 1, freeze ON
87 AE FF Camera 2, freeze OFF
87 AF FF Camera 2, freeze ON