The ultimate solution for Gas Detection Systems
STL
-154
8-20
07
DRÄGER REGARD
02 |
ST-
2107
-200
3
| 03
Technology for Life
For over thirty years Dräger has been leading the challenge to offer Gas Detection Solutions for the protection of human life, industrialassets and the environment. The technological solution offered byDräger, supported by its global infrastructure of Dräger Service ensures a total company commitment to safety.
Combining the innovative technology used byDräger and the competencies of the Dräger gasdetection system engineers, clients and customerscan be 100% confident in the solution offered byDräger. Dräger is the market leader for all GasDetection Solutions, including field devices andHuman Machine Interfaces.
Customers and clients rely on the advice andsolutions offered by Dräger, thus demonstratingtheir confidence with the technology employed, theease and flexibility of dealing with an internationalcompany and the long term integrity of after salessupport.
Dräger works in close collaboration with all of theircustomers and clients to find the best possible
solution, taking care of the initial investment withoutany reduction in safety. Experts from Dräger arealways available to study an application, give adviceon existing systems and propose new and costeffective solutions or modifications.
The Life Cycle approach from Dräger ensures thatnot only the current and instantaneous demand for safety is fulfilled, but the long term cost ofownership, serviceability and where necessary de-commissioning are all part of the initial designplan. This approach by Dräger meets with the latestdemands of EN 50402 ‘Electrical apparatus for thedetection and measurement of combustible or toxicgases or vapours or of oxygen - Requirements onthe functional safety of fixed gas detectionsystems’.
A customised Dräger REGARD system
ApprovalsATEX performanceapproved systems require a supporting QualityAssurance Certificate from a Notified Body
ST-
523-
98
ST-
294-
2007
The Dräger REGARD family
This requirement is totally satisfied by the DrägerREGARD system; the Dräger REGARD system has ATEX certification II (2) G.
For applications where ATEX certification is notdemanded the standard Dräger REGARD controlsystem is offered.
Dräger offers many different types of gas detectorfor the detection of combustible gases / vapours,toxic gases and for oxygen deficiency / enrichment.The Dräger REGARD system fully supports eachtype of gas detector whether the gas detector is athree or two wire device, a conventional 4 to 20 mAdevice, a HART addressable device or a simple mVbridge signal device.
The Dräger REGARD Gas Detection Systemrecognises the need to interface with top tier DCS systems and third party SCADA systems. To support these external links the DrägerREGARD system includes standard industrialgateways, supporting Modbus RTU and / orProfibus DP protocols.
REGARD describes Dräger’s modular control system for Gas DetectionSystems and Solutions.
Universal channel cards, multiplexing modules and HART fieldbus interfaces, supported byModbus RTU and Profibus DP gateways make up the Dräger REGARD family. All of the DrägerREGARD I/O cards / modules are available with or without ATEX measurement performancecertification. The simplistic design and systemconfiguration methods of the Dräger REGARDsystem ensures that the Dräger REGARD familycan be easily designed, configured and set intooperation by the end user or by your local DrägerService representative.
The Dräger REGARD family of control cards andmodules is well established. The installed basecomprises of over 240,000 I/O points. With thisexperience the migration to comply with the ATEXDirective 94/9/EC and the latest demands of EN50402 (based on EN 61508) was seamless for theDräger REGARD family of products.
The ATEX Directive 94/9/EC asks for performanceapproval of the entire system when there is a directfunction to remove the risk of explosion (ignition).
04 |
Dräger REGARD rack 19" Dräger Vision32 - a typical viewing screen
2-66
9-95
ST-
292-
2007
ST-
3837
-200
4
ST-
467-
2008
Standard or custom solutions
With over thirty years of gas detection experienceDräger are ideally place to offer a standard gasdetection solution or engineer a specific solution to a specific application. From conceptual designthrough to system installation and start-up DrägerSaftey are there to help.
Standard Dräger REGARD gas detection systemsutilise components from within the Dräger REGARDrange and are normally constructed into a centralcontrol cabinet. The alarm logic and systemintegration is normally basic and straight forward. A rigid design is normally used.
Complex, or custom systems take one further step.It is normal to use standard Dräger REGARDcomponents; however the overall system complexityis derived from the use of third party equipment. For custom system we offer flexible solutions toyour application. Before we commence our systemdesign to meet with your requirements we under -take a detailed analysis of your current situation.
With our global set-up, therefore our local presence,we can visit your facility and engage in detailedcommunication with respect to your application. Wethen work together planning a final solution. Designchanges, system modifications and detailed plansfor installation and commissioning are all part ofour planning element.
Where systems are required to meet a minimumsafety target governed by EN 50402, our experiencedsystem engineers will provide detailed calculationsto support a specific SIL target.
| 05
A typical Dräger REGARDsystem
Dräger REGARD rack 1/2 19"
ST-
286-
2007
ST-
339-
2004
06 |
Gas detector transmitter for toxicgases and oxygen
Gas detector transmitter forflammable gases and vapours
Horn
Strobe
110 / 230 vac
24 vdc UPS
Dräger REGARD HART Interface
Open path detector for flammablegases and vapours
CENTRAL SYSTEM
Dräger REGARDInstallation
| 07
INSTALLATION METHODS
POINT TO POINT WIRING
Using either single input Dräger REGARD cards or mutli-entry Dräger REGARD modules each fielddevice can be installed and wired to the DrägerREGARD central system using conventional pointto point wiring.
Multi-entry Dräger REGARD modules are flexibleenough to allow remote installation, utilising pointto point wiring locally and a single RS485 link tothe central control unit.
HART MULTI-DROP
Using a Dräger REGARD HART® card allowsDräger Polytron transmitters to be multi-droppedonto a single field cable. This offers a reduction inthe quantity of field cable used. The number oftransmitters on a single multi-drop loop is dictatedby the individual installation parameters. Specialistadvice and design services are offered by Dräger.
SYSTEM INTERFACING
The Dräger REGARD system recognises the needto interface with top tier DCS systems or theDräger Vision32 SCADA system. The DrägerREGARD system utilises the two main protocolscommonly found around the globe. Both ModbusRTU and Profibus DP protocols are used.
REMOTE CABINET
Dräger Polytron 7000RS485
Pellistor
24 vdc
24 vdc
Modbus RTU / Profibus DPSCADA system
HART Diagnostics protocolDiagnostic system
08 |
Dräger Vision32 – Multiple SCADA solutions from Dräger
Dräger Vision32 is configured from the Rockwellsoftware package. Using gas detector icons todisplay the Dräger REGARD gas information,status and historical records ensures that allDräger Vision32 systems are easily configured and operated.
Each Dräger Vision32 system requires a runtimelicense. The license required is determined by thesize and flexibility of the SCADA system and istotally dependant upon the end users requirements.For a runtime license, Dräger will remain responsiblefor the total configuration of the Dräger Vision32system and any subsequent modifications.
SIGNAL INFORMATION TYPES
The following signal information is transmitted via a serial interface (RS232, RS422/RS485) from theDräger REGARD Modbus gateway card to the PCand displayed by the visualisation software DrägerVision32.
For each Dräger REGARD channel:– Current measured value (gas concentration)– Current status of gas alarms A1, A2 and A3/Fault
condition– Calibration and maintenance override– Card inhibit mode– Equipment or system failure
DISPLAY INFORMATION
The following display screens can be configured:– Bar graphs showing five gas channels
simultaneously– Alarm window showing event history– Overview of plant images– Operator functions– Customised inputs e.g. wind direction
INTEGRATION OF PLANT IMAGES
Plant images can be imported into the DrägerVision32 software. This allows each individual gas detector to be linked to a plant image, thussupporting the system operator with locationinformation should a gas leak occur. The gasdetector icon shows the gas alarm and fault status as well as inhibit and calibration signal.
By selecting any gas detector icon, a bar graphwindow is called up showing gas value, alarmlevels, maintenance and override status and faultcondition. Trending can be selected in a furtherstep.
Dräger Vision32 is an example of a SCADA system specifically designed to support any Dräger REGARD system. The Vision32 system graphicallydepicts gas concentration, status changes such as gas alarming,malfunction and maintenance overrides. All information can be displayedas either bar graphs, tables, XY diagrams and/or plant images.
| 09
TRENDING
Trending is an integral function of the DrägerVision32 system. The accuracy, performance andlimitations are all restricted by the base software.
Normally the Dräger Vision32 system offers ahistorical trend of up to 90 days.
EVENT LOGGING
Each software base package is delivered with itsown default event logging package; a system eventlog. Event logs can be configured to identify alarmevents for gas and fault, maintenance and overrides,channel inhibit and alarm acknowledgement. All of these events are customer specific and areconfigured into the final Dräger Vision32 packageafter detailed discussion with the end user.
MINIMUM HARDWARE REQUIREMENTS
– IBM Pentium II 2.6 GHz computer– Minimum of 1 GB RAM– 80 GB hard drive– CD/DVD-ROM drive, 3.5" disk drive– SVGA or higher colour monitor– One serial port– USB ports– Network adaptor– Minimum 17" screen
SOFTWARE REQUIREMENTS
– Operating system – Windows 2000/XPProfessional
– Runtime licence Rockwell RS View 6.5– Runtime, Kepserver, Enterprise, Modbus OPC 3.1
STL
-290
-200
7
ST-
287-
2007
ST-
325-
2004
Profibus DP gateway An interface module for connection to thirdparty systems
Modbus RTU gateway A serial interface cardfor connection to thirdparty systems, includingDräger Vision32
10 |
DRÄGER REGARD COMPONENTS
ST-
330-
2004
ST-
477-
2001
ST-
329-
2004
ST-
330-
2004
ST-
328-
2004
ST-
332-
2004
ST-
331-
2004
8 entry 4 to 20 mA moduleA single DIN rail mountingmodule for the directconnection of up to eight 4 to 20 mA transmitters
ST-
2-66
9-95
19" rackStandard cardframe for allindustrial cabinets
8 way display cardA control card to interfacewith the 8 entry 4 to 20 mAmodules. The card has a localdisplay, 3 common gas alarmlevels, optional common faultand a remote reset input
SE Ex cardA single channel controlcard with local display, 3 gas alarm levels, optionalfault, repeat 4 to 20 mAand a remote reset input S
T-32
6-20
04
HART cardA multiplexing alarm cardwith local display, 3 common gas alarm levels,optional common fault anda remote reset input
ST-
327-
2004
ST-
336-
2004
Relay moduleA DIN rail mounting modulefor the direct connection ofup to sixteen alarm devices.Sixteen modules can beconnected to a single relaydisplay card
Relay display cardA control card to interfacewith the relay modules. Thecard has a local display,flexible relay logic and faultalarm
ST-
339-
2004
1/2 19" rackHalf size cardframe forcustomised solutions
ST-
325-
2004
Modbus RTU gatewayA single card with ModbusRTU protocol giving gasand alarm data via RS232,RS485 or RS422
ST-
287-
2007
Profibus DP gatewayA single DIN rail modulewith Profibus DP protocolgiving gas and alarm data
4 to 20 mA Optical cardA single channel control cardspecifically for Infrared gasdetections with local display,2 gas alarm levels, 2 faultlevels, repeat 4 to 20 mA anda remote reset input
4 to 20 mA cardA single channel controlcard with local display, 3 gas alarm levels, optionalfault, repeat 4 to 20 mA anda remote reset input
Extra Master cardA silent, no supervisionMaster card offeringadditional single, commonand voting alarms
Master cardA system Master card whichsupervises up to 99 inputchannels. Offers common,single and voting alarms anda remote system reset input
D-1
2700
-200
9
Interface cardA single card to interfacebetween the REGARDsystem and a PC to send,receive and modify thesystem configuration.
| 11
ORDER INFORMATION
Standard Dräger REGARD cards Order No
Master card 42 05 702
4 to 20 mA card 42 05 701
4 to 20 mA Optical card 42 06 085
SE Ex card 42 05 703
HART card 42 05 900
HART 7000 card 42 08 987
8 way display card 42 06 078
8 entry 4 to 20 mA module 42 06 079
Relay display card 42 06 081
Relay module 42 06 432
Modbus card V 1.9 42 05 706
Modbus card V 2.0 42 06 739
Profibus DP gateway AG 00 485
Interface card 8322990
ATEX Dräger REGARD cards
Master card 42 06 708
4 to 20 mA card 42 06 706
4 to 20 mA Optical card 42 06 721
SE Ex card 42 06 707
8 way display card 42 06 717
8 entry 4 to 20 mA module 42 06 718
Relay display card 42 06 719
Relay module 42 06 720
Rack systems
19" rack 42 05 700
1/2 19" rack 42 05 709
90 4
6 26
4 |
02.
10-1
| M
arke
ting
Com
mun
icat
ions
| C
S |
PR
| L
E |
Pri
nted
in
Ger
man
y |
Chl
orin
e-fr
ee –
env
iron
men
tally
com
patib
le |
Sub
ject
to
mod
ifica
tions
| ©
201
0 D
räge
r S
afet
y A
G &
Co.
KG
aA
HEADQUARTERSDräger Safety AG & Co. KGaARevalstrasse 123560 Lübeck, Germany
www.draeger.com
GERMANYDräger Safety AG & Co. KGaARevalstrasse 123560 LübeckTel +49 451 882-2794Fax +49 451 882-4991
FRANCEDräger Safety France SAS3c route de la Fédération, BP 8014167025 Strasbourg Cedex 1Tel +33 3 88 40 59 29Fax +33 3 88 40 76 67
SINGAPOREDraeger Safety Asia Pte Ltd67 Ayer Rajah Crescent #06-03Singapore 139950Tel +65 68 72 92 88Fax +65 65 12 19 08
UNITED KINGDOMDraeger Safety UK Ltd.Blyth Riverside Business ParkBlyth, Northumberland NE24 4RGTel +44 1670 352 891Fax +44 1670 544 475
SYSTEM CENTERS
P. R. CHINABeijing Fortune Draeger SafetyEquipment Co., Ltd.A22 Yu An Rd, B Area, Tianzhu Airport Industrial Zone,Shunyi District, Beijing 101300Tel +86 10 80 49 80 00Fax +86 10 80 49 80 05
USADraeger Safety, Inc.505 Julie Rivers, Suite 150Sugar Land, TX 77478Tel +1 281 498 1082Fax +1 281 498 5190