The Fumigation Monitor Company. Integrated Fumigation Monitoring &Web Based Data Acquisition Methyl Bromide & Alternatives Conference Surabaya, Indonesia PART 2. Sulfuryl Fluoride SO2F2. Corrects Temperature Differences Compensates for Pressure Changes - PowerPoint PPT Presentation

Citation preview

Page 1: The Fumigation Monitor Company

The Fumigation Monitor Company

Integrated Fumigation Monitoring &Web Based Data AcquisitionMethyl Bromide & Alternatives Conference

Surabaya, IndonesiaPART 2

Page 2: The Fumigation Monitor Company

Sulfuryl Fluoride

SO2F2

Page 3: The Fumigation Monitor Company

1. Corrects Temperature Differences

2. Compensates for Pressure Changes

3. Gas Specific NO Interference Gases

4. Calibration (14,000+Sensors)

5. NOT EMF Susceptible

6. Consistent Ideal Gas Law PV=nRT

Page 4: The Fumigation Monitor Company

   当前位置:办公厅>新闻发布>图片新闻

宁波局穿山港办事处启用熏蒸气体检测仪

        日前,宁波检验检疫局穿山港办事处在宁波口岸启用了性能先进、携带方便的熏蒸气体检测仪。该仪器能够在较短的时间内准确检测出集装箱内残留的有毒有害熏蒸气体的浓度,有效保障现场检验检疫人员及作业人员的人身安全。此前,该办事处已经配备了两台性能优良的通道式放射性检测仪,大量高科技检测设备的投入使用必将进一步提高穿山港区废物原料通检效率。

相关文档:

Page 5: The Fumigation Monitor Company

Warehouse SF Fumigation

Page 6: The Fumigation Monitor Company

Warehouse SF Fumigation

Gas Added

Page 7: The Fumigation Monitor Company
Page 8: The Fumigation Monitor Company

Methyl BromideCH3Br

Page 12: The Fumigation Monitor Company

start time Duration Container Position 温度reading(g/m3)

MB3000

MB-ContainIR

ZR-A

11/5/2008 12:00 26 hours 011031 bottom 22℃ 43 42.8 55.9 11/5/2008 12:13 20 hours23mins 022435 bottom 22℃ 63 63.4 88.3 11/5/2008 13:40 27hours40mins 011031 top 22℃ 34 34.2 42.2 11/5/2008 14:30 22hours40mins 022435 top 23℃ 58 59.0 87.2 11/5/2008 14:35 28hours35mins 011031 bottom 23℃ 41 40.9 56.3 11/5/2008 14:40 28hours40mins 011031 top 23℃ 35 34.8 47.2 11/5/2008 14:50 23hours 022435 bottom 23℃ 62 61.6 72.6 11/5/2008 15:10 10mins 228489 bottom 23℃ 123  124.0 147.2 11/5/2008 15:20 29hours20mins 011031 middle 23℃ 41 40.6 55.7 11/5/2008 15:30 35mins 336106 bottom 23℃ 85 83.9 109.2 11/5/2008 15:40 45mins 401681 bottom 23℃ 82 81.3 109.4

Shanghai CIQ Quarantine Fumigation20-30% Error with Thermoconductivity Monitor (NO P&T Correction)

Page 13: The Fumigation Monitor Company

12/17/2007

MeBr at Lab Temperature - Spectros Test LV1008

Pr. Temp.PPM per Air MeBr PPM g/m3 Spectros

Difference

mm Hg °C g/m3 ml ml Calc. Calc IR-g/m3Calc-Instr. %

748.0 28 264.44 8000 20 2,494 9.4 9.5 0.1 0.7%753.2 28 262.61 8000 40 4,975 18.9 18.6 -0.3 -1.8%748.2 28 264.37 8000 80 9,901 37.5 37.4 -0.1 -0.1%748.0 28 264.44 8000 120 14,778 55.9 56.9 1.0 1.8%748.0 28 264.44 8000 160 19,608 74.1 74.7 0.6 0.7%749.7 28 263.84 8000 240 29,126 110.4 110.5 0.1 0.1%749.9 28 263.77 8000 320 38,462 145.8 145.0 -0.8 -0.6%749.9 28 263.77 8000 420 49,881 189.1 187.4 -1.7 -0.9%750.5 28 263.56 7800 500 60,241 228.6 225.5 -3.1 -1.3%751.5 28 263.21 8000 600 69,767 265.1 262.1 -3.0 -1.1%751.5 28 263.21 8000 700 80,460 305.7 302.5 -3.2 -1.0%752.1 28 263.00 8000 800 90,909 345.7 339.3 -6.4 -1.8%752.5 28 262.86 8000 1000 111,111 422.7 418.0 -4.7 -1.1%

USDA Test of Methyl Bromide MBContainIR #LV1008

APPROVED

Page 14: The Fumigation Monitor Company

MBContainIR is USDA Approved

APPROVED

Page 15: The Fumigation Monitor Company

Apples from New Zealand to Japan

Compliant Quarantine Pre Shipment Certification

Page 17: The Fumigation Monitor Company

Web Based Fumigation Monitoring & Data Acquisition

Page 18: The Fumigation Monitor Company

Web Based Platforms• Hardened Enclosure

• Advanced Infrared Technology (NDIR)

• Solid State Electronics• Modular Components• Multiple Sample Positions• Web Based Data Acquisition &

Management

NEMA Fixed

Transportble

Page 19: The Fumigation Monitor Company

Encrypted, Flexible ,Secure Data Transmission

Page 20: The Fumigation Monitor Company

Secured, Encrypted Website

Page 21: The Fumigation Monitor Company

Threshold Settings for Action Alerts

Page 22: The Fumigation Monitor Company

Main Networking FunctionsFTP-Based File Transfer

Page 23: The Fumigation Monitor Company

USA Federal Register 21 CFR Part 11Calibrated Fumigant Gas CylinderSpectros Monitors Pressure and Temperature Calibration Verification Onsite and Individual

Fumigation Proof of Compliance Encrypted Transfer of Secured Data Like “Bank

Transfer”Government Enforcement PROOF

Electronic Notebook: Traceable to Compliance

Page 24: The Fumigation Monitor Company

AN ENCRYPTED WEB BASED TRANSFER OF FUMIGATION DATA

STEP1: Fumigation Collects CxT Secured Data

STEP2: Method Defined CxT has Spectros Issues Certificate Pass/Fail TRACEABLE TO CERTIFIED CALIBRATION GAS

STEP3: Good Fumigation gets Spectros Notification to Customer/ Government Agency Protected Server (ENCRYPTED)

STEP4: Governing Agency Issues THEIR TRACKING # (Unique and No Way to Counterfeit)

STEP5: This # Used by Brokers/Forwarders/Shipping Companies

USA FEDERAL REGISTER: Electronic Notebook 21CFR Part 11

China CIQ & Chile SAG