FUMIGATION OF FARM STORED GRAIN AND of equipment needed for fumigation ..... 12 Bin preparation prior to fumigation ..... 13 Calculating dosage

  • View
    225

  • Download
    7

Embed Size (px)

Text of FUMIGATION OF FARM STORED GRAIN AND of equipment needed for fumigation ..... 12 Bin preparation...

  • FUMIGATION OF FARM STORED GRAINAND STRUCTURES

    COOPERATIVE EXTENSION SERVICECollege of Agriculture

    The University of WyomingDEPARTMENT OF PLANT, SOIL AND INSECT SCIENCES

  • Trade or brand names used in this publication are used only for the purpose of educational information. The information givenherein is supplied with the understanding that no discrimination is intended, and no endorsement information of products by theAgricultural Research Service, Federal Extension Service, or State Cooperative Extension Service is implied. Nor does it implyapproval of products to the exclusion of others which may also be suitable.

    Issued in furtherance of Cooperative Extension work, acts of May 8 and June 30,1914, in cooperation with the U.S. Departmentof Agriculture, Glen Whipple, Director, Cooperative Extension Service, University of Wyoming Laramie, WY. 82071.

    Persons seeking admission, employment or access to programs of the University of Wyoming shall be considered without regardto race, color, national origin, sex, age, religion, political belief, handicap, or veteran status.

  • FUMIGATION OF FARM STORED GRAINAND STRUCTURES

    (revised September 1996)

    Mark A. FerrellExtension Pesticide Coordinator

    AcknowledgmentsThe section on Insect Pest Management for Farm Stored Grain was modified from the

    publication Insect Pest Management for Farm Stored Grain (EB-45) originally produced byDean K. McBride, Extension Entomologist of the North Dakota State University Extension

    Service.

    The section on Fumigation of Structures Including Buildings, Ships & Railcars was modifiedfrom the publication Fumigation Manual Category 7C, A Guide for Private and Commercial

    Pesticide Applicators (CS-27) originally produced by the Iowa State University ExtensionService.

  • i

    TABLE OF CONTENTS

    INSECT PEST MANAGEMENT FOR FARM STORED GRAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . 1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1TYPES OF STORED GRAIN INSECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

    Surface feeders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Internal feeders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1External feeders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

    CONDITIONS THAT ENCOURAGE STORED GRAIN INSECTS . . . . . . . . . . . . . . . . . . . . . . . 2SOURCES OF INFESTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2MONITORING BINS FOR INSECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3USE OF INSECT TRAPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3PREVENTION OF STORED GRAIN INSECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

    Bin sanitation and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Bin spraying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Grain protectants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Application of grain protectants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Control grain temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    INSECT CONTROL OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6FUMIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    Types of fumigants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Factors which influence the effectiveness of fumigation . . . . . . . . . . . . . . . . . . . . . . . . 9

    Sorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Grain Moisture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Grain Type and Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Insects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Storage Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Air Movement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Dosage and time of exposure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    Application and distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Aluminum Phosphide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Methyl bromide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Checklist of equipment needed for fumigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Bin preparation prior to fumigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Calculating dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Determining concentrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Detection tubes for fumigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Halide leak detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Summary of requirements for successful grain fumigation . . . . . . . . . . . . . . . . . . . . . 15Reasons for fumigation failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Insufficient Fumigant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Storage Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Type of Grain and Dockage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Moisture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    FUMIGATION OF STRUCTURES INCLUDING BUILDINGS, SHIPS & RAILCARS . . . . . . . . . 16INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

  • ii

    VAULT FUMIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Vacuum chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    ATMOSPHERIC VAULTS OR FUMIGATION CHAMBERS . . . . . . . . . . . . . . . . . . . . . . . . . . 16TRUCKS (STATIONARY) AND FREIGHT CARS (STATIONARY OR IN TRANSIT) . . . . . 16SHIPBOARD FUMIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17BUILDING FUMIGATION (BY SEALING) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17PREMISES INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17TARPAULIN FUMIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Outdoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Entire structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    SPOT OR LOCAL FUMIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19GENERAL FUMIGATIONS (MILLS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19AERATION OR VENTILATION OF FUMIGANTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20FACTORS AFFECTING AERATION TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    Rate of air exchange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Sorption and desorption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    AERATION PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Building ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Tarpaulins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Fumig