System Configuration Data SheetFebruary 201500806-0100-5100, Rev AA
Rosemount Tank Gauging System
System InformationIn order to be able to correctly configure and assemble the parts of the system, the System Configuration Data Sheet must be filled in. It is also necessary to provide drawings of the tank farm layout with proposed location of Level Gauges, Field Displays, Tank Hubs, System Hubs, Field Bus Modems, TankMaster etc.
NoteThe information on this form is used for tagging signs, temperature sensor specification and wireless network information only. No setting of device data base is done based on information on this data sheet.
Please state all distances in metric units.
System Overview
Customer Information
Rosemount Tank Gauging system number:_______________________ Installation site: ____________________________________________
Total number of tanks: _______________________________________ Year and Month: ____________________________________________
End Customer:_____________________________________________ Contact Name: _____________________________________________
Telephone: ________________________________________________ P.O. Reference No:___________________________________________
Customer Signoff: ______________________________________________________________________________________________________
Email address: _________________________________________________________________________________________________________
www
ESD
TankMasterPC in Network
TankMaster.net for Web Access
Alternative Connectionto DCS/PLC/SCADA/Host
1420 Smart WirelessGateway
2460System Hub
Alternative Connectionto DCS/PLC/SCADA/Host
Alternative Connectionto DCS/PLC/SCADA/Host
5900C 775
3051S
5300
2160
3308
2410
644
22305900S2240S5400
3051S644
5900S 2-in-1
2410 2410
5400
Alarm
644 Temperature Transmitter with Single PointTemperature Sensor
Smart Wireless THUM Adapter
2230 GraphicalField Display
2410 Tank Hub
FieldCommunicator
5300 GuidedWave Radar Transmitter
765 Multiple Spot Temperature and Water Level Sensor
2240S Multi-input TemperatureTransmitter
565/566 Multiple Spot Temperature Sensor
2120/2130/2160Liquid Level Switch
3051S Pressure Transmitter
5900S Radar Level Gauge(2-in-1 optional)
Still-pipe Array Horn LPG/LNG Still-pipe Array Cone LPG/LNG
Parabolic
5900C Radar Level Gauge
3308 WirelessGuided Wave RadarTransmitter
5400 RadarLevelTransmitter
5900S 2240S2410
bolic
2180 FieldBus Modem
Fn1 2 34 5 67 8 9. 0 -
www.rosemount-tg.com
February 2015Rosemount Tank Gauging System
Tank Name Antenna Type Tank ProductTank Height
(mm)5900 Radar Tag Name
2410 Hub Tag Name
2240 Temp Tx Tag Name
2230 Display Tag Name
Note
2
February 2015 Rosemount Tank Gauging System
Tag/Tank name
L0 Temp sensor length include WLS (mm)
Position of temperature spot elements from sensor bottom end (mm)
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
3
February 2015Rosemount Tank Gauging System
Multiple Spot Temperature Sensor Multiple Spot Temperature Sensor with WLS
L= Distance from nozzle top to tank bottom
LW = Height of weight
LT = Total length of temp sensor and WLS
L0 = LT + 350 (mm)
Where:350 = Distance from top of sensor to lower thread (exact position of flange can be adjusted up or down about 100 mm at installation using the nuts and the 256 mm thread length)
Lowest temp. spot (T1) 0,5 - 1,0 m above tank bottom, min 300 mm from eye bolt in level sensor
Highest temp. spot 0,5 - 1,0 m below max level, min 1000 mm from top of sensor
L= Distance from nozzle top to tank bottom
LW = Height of weight
LT = Total length of temp sensor and WLS
L0 = LT + 350 (mm)
Where:350 = Distance from top of sensor to lower thread (exact position of flange can be adjusted up or down about 100 mm at installation using the nuts and the 256 mm thread length)
Lowest temp. spot (T1) 0,5 - 1,0 m above tank bottom, min 300 mm from eye bolt in level sensor
Highest temp. spot 0,5 - 1,0 m below max level, min 1000 mm from top of sensor
T1
LWLTLL0
T2T3
Min. 500 mm
Min. 1000 mm350
mm
Hig
hest
tem
pera
ture
ele
men
t <T1
6
Max Filling Level
T1
LWLTLL0
T2T3
Min
. 150
mm
Min. 500 mm
Min. 1000 mm350
mm
Hig
hest
tem
pera
ture
ele
men
t <T1
6
Max Filling Level
4
February 2015 Rosemount Tank Gauging System
Wireless Network Design (if included)
For complete help on preplanning of a Tank Gauging Wireless network see Reference Manual 300570EN. Tools to be used are a scaled sketch of the
installation site and AMS Wireless SNAP-ON Software.
Rule of 5 Found to be OK: Comments: _____________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
Rule of 3 Found to be OK: Comments:____________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
Rule of 25% Found to be OK: Comments:____________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
Make a small sketch of the planned Wireless Network or send a copy of the SNAP-ON design picture
5
Rosemount Tank Gauging World Headquarters
System Configuration Data SheetFebruary 2015
Rosemount Tank Gauging System00806-0100-5100, Rev AA
Emerson Process Management Box 130 45SE-402 51 GothenburgSWEDEN
+46 31 337 00 00+46 31 25 30 22 [email protected]
Rosemount Tank Gauging North America Inc.Emerson Process Management 6005 Rogerdale RoadMail Stop NC 13677072 Texas, Houston, USA
+1 281 988 4000+1 800 722 2865 [email protected]
Latin America Regional OfficeEmerson Process Management 1300 Concord Terrace, Suite 400Sunrise, Florida, 33323, USA
+1 954 846 5030+1 954 846 [email protected]
Asia Pacific Regional OfficeEmerson Process Management Asia Pacific Pte Ltd1 Pandan CrescentSingapore 128461
+65 6777 8211+65 6777 0947 [email protected]
Rosemount Tank Gauging Middle East & Africa.Emerson Process Management P. O Box 20048Manama, Bahrain
+973 1722 6610+973 1722 7771 [email protected]
The Emerson logo is a trademark and service mark of Emerson Electric Co.Rosemount and Rosemount logotype are registered trademarks of Rosemount Inc.All other marks are the property of their respective owners.
© 2015 Rosemount Tank Radar AB all rights reserved.