PRDCM Series
D-44 D-45
Cylindrical Long Sensing Distance, Connector Type Proximity Sensor
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.※2: The weight includes packaging. The weight in parenthesis is for unit only.※Environment resistance is rated at no freezing or condensation.
Model
PRDCMT12-4DOPRDCMT12-4DCPRDCMT12-4DO-IPRDCMT12-4DC-I
PRDCMT12-8DO PRDCMT12-8DC PRDCMT12-8DO-I PRDCMT12-8DC-I
PRDCMT18-7DO PRDCMT18-7DC PRDCMT18-7DO-IPRDCMT18-7DC-IPRDCMLT18-7DOPRDCMLT18-7DCPRDCMLT18-7DO-IPRDCMLT18-7DC-I
PRDCMT18-14DOPRDCMT18-14DCPRDCMT18-14DO-IPRDCMT18-14DC-IPRDCMLT18-14DOPRDCMLT18-14DCPRDCMLT18-14DO-IPRDCMLT18-14DC-I
PRDCMT30-15DOPRDCMT30-15DCPRDCMT30-15DO-IPRDCMT30-15DC-IPRDCMLT30-15DOPRDCMLT30-15DCPRDCMLT30-15DO-IPRDCMLT30-15DC-I
PRDCMT30-25DOPRDCMT30-25DCPRDCMT30-25DO-IPRDCMT30-25DC-IPRDCMLT30-25DOPRDCMLT30-25DCPRDCMLT30-25DO-IPRDCMLT30-25DC-I
Diameter of the sensing side 12mm 18mm 30mmSensing distance 4mm 8mm 7mm 14mm 15mm 25mm
Installation Shield (flush)
Non-shield(non-flush)
Shield (flush)
Non-shield(non-flush)
Shield (flush)
Non-shield(non-flush)
Hysteresis Max. 10% of sensing distance
Standard sensing target 12×12×1mm (iron)
25×25×1mm (iron)
20×20×1mm (iron)
40×40×1mm (iron)
45×45×1mm (iron)
75×75×1mm (iron)
Setting distance 0 to 2.8mm 0 to 5.6mm 0 to 4.9mm 0 to 9.8mm 0 to 10.5mm 0 to 17.5mmPower supply(operating voltage)
12-24VDCᜡ(10-30VDCᜡ)
Leakage current Max. 0.6mAResponse frequency※1 450Hz 400Hz 250Hz 200Hz 100Hz 100Hz Residual voltage Max. 3.5VAffection by Temp. Max. ±10% for sensing distance at ambient temperature 20Control output 2 to 100mAInsulation resistance Over 50MΩ (at 500VDC megger)Dielectric strength 1,500VAC 50/60Hz for 1 minuteVibration 1mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hoursShock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 timesIndicator Operation indicator: red LED (4 sides)
EnvironmentAmbient temperature -25 to 70, storage: -30 to 80Ambient humidity 35 to 95%RH, storage: 35 to 95%RH
Protection circuit Surge protection circuit, power reverse polarity protection circuit, output short over current protection circuit
Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing surface: heat-resistant acrylonitrile butadiene styrene
ApprovalProtection structure IP67 (IEC standard)
Weight※2 Approx. 28g (approx. 18g) PRDCMT: Approx. 60g(approx. 42g)PRDCMLT: Approx. 78g(approx. 60g)
PRDCMT: Approx. 150g(approx. 110g)PRDCMLT: Approx. 190g(approx. 150g)
Features
Specifications
Long sensing distance (1.5 to 2 times longer sensing distance guaranteed compared to existing models)
Shorten the time of maintenance Easy to check operation from various angles with 4-side LED (DC 2-wire) Red LED operation indicator (DC 3-wire) Improved the noise immunity with dedicated IC Built-in surge protection, reverse polarity protection,
over-current protection circuit IP67 protection structure (IEC standard)
DC 2-wire type
Please read “Safety Considerations” in operation manual before using.
Cylindrical Long Sensing Distance, Connector Type
D-44 D-45
(A) Photoelectric Sensors
(B) FiberOpticSensors
(C) Door/AreaSensors
(D) ProximitySensors
(E) PressureSensors
(F) RotaryEncoders
(G) Connectors/Connector Cables/Sensor Distribution Boxes/ Sockets
(H)TemperatureControllers
(I)SSRs / PowerControllers
(J) Counters
(K) Timers
(L) PanelMeters
(M)Tacho /Speed / PulseMeters
(N)DisplayUnits
(O)SensorControllers
(P)SwitchingMode PowerSupplies
(Q)Stepper Motors & Drivers & Controllers
(R)Graphic/LogicPanels
(S)FieldNetworkDevices
(T) Software
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.※Environment resistance is rated at no freezing or condensation.
Model
PRDCM12-4DN PRDCM12-4DP PRDCM12-4DN2 PRDCM12-4DP2 PRDCML12-4DN PRDCML12-4DP PRDCML12-4DN2 PRDCML12-4DP2
PRDCM12-8DN PRDCM12-8DP PRDCM12-8DN2 PRDCM12-8DP2 PRDCML12-8DN PRDCML12-8DP PRDCML12-8DN2 PRDCML12-8DP2
PRDCM18-7DN PRDCM18-7DP PRDCM18-7DN2 PRDCM18-7DP2 PRDCML18-7DN PRDCML18-7DP PRDCML18-7DN2 PRDCML18-7DP2
PRDCM18-14DN PRDCM18-14DP PRDCM18-14DN2 PRDCM18-14DP2 PRDCML18-14DN PRDCML18-14DP PRDCML18-14DN2 PRDCML18-14DP2
PRDCM30-15DN PRDCM30-15DP PRDCM30-15DN2 PRDCM30-15DP2 PRDCML30-15DN PRDCML30-15DP PRDCML30-15DN2 PRDCML30-15DP2
PRDCM30-25DN PRDCM30-25DP PRDCM30-25DN2 PRDCM30-25DP2 PRDCML30-25DN PRDCML30-25DP PRDCML30-25DN2 PRDCML30-25DP2
Diameter of the sensing side 12mm 18mm 30mmSensing distance 4mm 8mm 7mm 14mm 15mm 25mm
Installation Shield (flush)
Non-shield(non-flush)
Shield (flush)
Non-shield(non-flush)
Shield (flush)
Non-shield(non-flush)
Hysteresis Max. 10% of sensing distance
Standard sensing target 12×12×1mm (iron)
25×25×1mm (iron)
20×20×1mm (iron)
40×40×1mm (iron)
45×45×1mm (iron)
75×75×1mm (iron)
Setting distance 0 to 2.8mm 0 to 5.6mm 0 to 4.9mm 0 to 9.8mm 0 to 10.5mm 0 to 17.5mm Power supply(operating voltage)
12-24VDCᜡ(10-30VDCᜡ)
Current consumption Max. 10mAResponse frequency※1 500Hz 400Hz 300Hz 200Hz 100Hz 100HzResidual voltage Max. 1.5VAffection by Temp. Max. ±10% for sensing distance at ambient temperature 20Control output Max. 200mAInsulation resistance Over 50MΩ (at 500VDC megger) Dielectric strength 1,500VAC 50/60Hz for 1 minuteVibration 1mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hoursShock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 timesIndicator Operation indicator: Red LED
Environ-ment
Ambient temperature -25 to 70, storage: -30 to 80Ambient humidity 35 to 95%RH, storage: 35 to 95%RH
Protection circuit Surge protection circuit, power reverse polarity protection circuit, output short over current protection circuitProtection structure IP67 (IEC standard)
Material Case/Nut: nickel plated brass, washer: nickel plated iron, Sensing surface: heat-resistant acrylonitrile butadiene styrene
Approval
Unit Weight PRDCM: approx. 26gPRDCML: approx. 34g
PRDCM: approx. 48gPRDCML: approx. 66g
PRDCM: approx. 142gPRDCML: approx. 182g
Specifications DC 3-wire type
PRDCM Series
D-46 D-47
(unit: mm) Dimensions PRDCMT12-4D - PRDCMT12-8D -
PRDCMT18-14D -
PRDCMT30-15D - PRDCMT30-25D -
Ø4235 Operation
indicator(red)
6328 2510
5M30×1.5 M12×1
Ø2117 Operation
indicator(red)
56.57
4 M12×1 M12×1
24.5 25
Ø2924 Operation
indicator(red)
589.5
4 M18×1 M12×1
23.5 25
Ø4235 Operation
indicator(red)
6338 25
5M30×1.5 M12×1
PRDCMT18-7D -
Ø2924
58
4 M18×1 M12×1
33 25 Operationindicator(red)
Ø2117
56.5
4 M12×1 M12×1
31.5 25 Operationindicator(red)
PRDCMLT18-7D -
PRDCMLT30-15D - PRDCMLT30-25D -
PRDCMLT30-14D -
Ø2924
8762
4M18×1 M12×1
Operationindicator(red)
85
60
M12×15
Ø42
35 Operationindicator(red)
Ø2924
M12×1
8752
4 M18×1
Operationindicator(red)
Ø42
35
85
5010
M12×15
Operationindicator(red)
M30×1.5 M30×1.5
10
Cylindrical Long Sensing Distance, Connector Type
D-46 D-47
(A) Photoelectric Sensors
(B) FiberOpticSensors
(C) Door/AreaSensors
(D) ProximitySensors
(E) PressureSensors
(F) RotaryEncoders
(G) Connectors/Connector Cables/Sensor Distribution Boxes/ Sockets
(H)TemperatureControllers
(I)SSRs / PowerControllers
(J) Counters
(K) Timers
(L) PanelMeters
(M)Tacho /Speed / PulseMeters
(N)DisplayUnits
(O)SensorControllers
(P)SwitchingMode PowerSupplies
(Q)Stepper Motors & Drivers & Controllers
(R)Graphic/LogicPanels
(S)FieldNetworkDevices
(T) Software
(unit: mm) Dimensions
PRDCML12-8D
Ø21
17
68.3
37
M12×1 M12×14
7
PRDCML18-14D
86.8
52
M18×1 M12×14
10Ø2924
PRDCML30-25D
Ø42
35
85.8
50
M30×1.5 M12×15
10
PRDCML30-15D
Ø42
35
85.8
60
M30×1.55 M12×1
PRDCML18-7D
87.362.5
M18×1 M12×14
Ø29
24
PRDCML12-4D
Ø21
17
68.3
44
M12×1 M12×14
PRDCM12-4D PRDCM12-8D
PRDCM18-7D PRDCM18-14D
Ø29
24
53.81910
4 M18×1 M12×1
PRDCM30-15D
Ø42
35
63.8
38
5 M30×1.5 M12×1
PRDCM30-25D
Ø42
35
63.82810
5 M30×1.5 M12×1
Ø21
17
M12×1
55.8
31.5
4 M12×1
Ø29
24
54.3
29.5
4 M18×1 M12×1
Ø21
17
55.8
24.57
4 M12×1 M12×1
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
Operationindicator(red)
PRDCM Series
D-48 D-49
Control Output Diagram and Load Operation
4
3
Mai
n ci
rcui
t
Load +V
0V
Brown
Blue
Sensingtarget
OperationIndicator(red LED)
Load
PresenceNone
OperationReturn
ONOFF
N.O. N.C.
※The number in a circle is pin no. of connector.
NPN output type
10kΩ
Mai
n ci
rcui
t Load
+V
0VBlue
Brown
Black
PNP output type
Mai
n ci
rcui
tBlue
Brown
Black
10kΩ Load
+V
0V
1
4
3
DC 2-wire type
DC 3-wire type
1
4
3
Sensingtarget
OperationIndicator(red LED)
PresenceNoneOperationReturn
HLONOFF
N.O. N.C.
Load(brown-black)
Output voltage
(black-blue)
Sensingtarget
Output voltage
(black-blue)OperationIndicator(red LED)
PresenceNone
OperationReturn
HL
ONOFF
N.O. N.C.
Load(brown-black)
※②,③ of N.O. type and ③,④ of N.C. type are not used terminals.
※The pin arrangement of connector applying IEC standard is being developed.
※Please attach "I" at the end of the name of standard type for purchasing the IEC standard product.E.g.)PRDCMT12-4DO-I
※The connector cable for IEC standard is being developed. Please attach "I' at the end of the name of standard type. E.g.)CID2-2-I, CLD2-5-I
※Please fasten the vibration part with PEFE tape.※Refer to page G-6 about IEC standard connector wires
and specifications.
Wiring Diagram
※Please fasten the cleat of connector not to shown the thread. (0.39 to 0.49N.m)
NPN output type PNP output type
Load
2
3
1
4
Brown
Black
Blue
+V
0V
Load
2
3
1
4
Brown
Black
Blue
+V
0V
DC 3-wire type
DC 2-wire type (IEC standard type)
4
3
Normally Open (N.O.) Normally Closed (N.C.)
Load
23
14
+V
0V
Brown
Blue
+V
0V
Load
2
3
1
4
Brown
Blue
Normally Open (N.O.) / Normally Closed (N.C.)
Load +V
2
3
1
4
0V
Brown
Blue
Load
+V
2
3
1
4
0V
Brown
Blue
※Pin ①, ② are not used terminals.※For DC 3-wire type connector cable, it is available to use
with black wire (12-24V DC) and blue wire (0V).
DC 2-wire type (standard type)
Cylindrical Long Sensing Distance, Connector Type
D-48 D-49
(A) Photoelectric Sensors
(B) FiberOpticSensors
(C) Door/AreaSensors
(D) ProximitySensors
(E) PressureSensors
(F) RotaryEncoders
(G) Connectors/Connector Cables/Sensor Distribution Boxes/ Sockets
(H)TemperatureControllers
(I)SSRs / PowerControllers
(J) Counters
(K) Timers
(L) PanelMeters
(M)Tacho /Speed / PulseMeters
(N)DisplayUnits
(O)SensorControllers
(P)SwitchingMode PowerSupplies
(Q)Stepper Motors & Drivers & Controllers
(R)Graphic/LogicPanels
(S)FieldNetworkDevices
(T) Software
One side length of sensing target d (mm)
4.00
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCMT12-4D -
One side length of sensing target d (mm)
9.00
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCMT12-8D -
One side length of sensing target d (mm)
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)T18-7D -
One side length of sensing target d (mm)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)T18-14D -
One side length of sensing target d (mm)
18.00
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 9
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)T30-15D -
One side length of sensing target d (mm)
30.00
25.00
20.00
15.00
10.00
5.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)T30-25D -
Sensing Distance Feature Data by Target Material and Size Detecting
MethodSensing
distance (X)
Sen
sing
ta
rget
dO
ne s
ide
leng
th
PRDCM Series
D-50 D-51
PRDCM(L)12-4D
One side length of sensing target d (mm)
4.50
4.00
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)12-8D
One side length of sensing target d (mm)
9.00
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)18-7D
One side length of sensing target d (mm)
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)18-14D
One side length of sensing target d (mm)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)30-15D
One side length of sensing target d (mm)
18.00
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
PRDCM(L)30-25D
One side length of sensing target d (mm)
30.00
25.00
20.00
15.00
10.00
5.00
0.00
Sen
sing
dis
tanc
e X
(mm
)
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
Iron (SS401)
Stainless steel 364(SUS364)
Brass (C3601)Aluminum (ALS052)Copper (C1100)
Sensing Distance Feature Data by Target Material and Size Detecting
MethodSensing
distance (X)
Sen
sing
ta
rget
dO
ne s
ide
leng
th
Cylindrical Long Sensing Distance, Connector Type
D-50 D-51
(A) Photoelectric Sensors
(B) FiberOpticSensors
(C) Door/AreaSensors
(D) ProximitySensors
(E) PressureSensors
(F) RotaryEncoders
(G) Connectors/Connector Cables/Sensor Distribution Boxes/ Sockets
(H)TemperatureControllers
(I)SSRs / PowerControllers
(J) Counters
(K) Timers
(L) PanelMeters
(M)Tacho /Speed / PulseMeters
(N)DisplayUnits
(O)SensorControllers
(P)SwitchingMode PowerSupplies
(Q)Stepper Motors & Drivers & Controllers
(R)Graphic/LogicPanels
(S)FieldNetworkDevices
(T) Software
Sensing Distance Feature Data by Parallel (Left/Right) Movement Detecting
Method
Sen
sing
di
stan
ce (X
)
Sensing area (Y)
Sensing target
8.0
7.0
6.0
5.0
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
Sen
sing
dis
tanc
e X
(mm
)
Left ← Center → Right
Sensing area Y (mm)
6.0 4.0 2.0 0.0 2.0 4.0 6.0
PRDCM(L)12-4D /8D
PRDCM(L)12-4DPRDCM(L)12-8D
14.0
13.0
11.0
9.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Sen
sing
dis
tanc
e X
(mm
)
Left ← Center → Right
Sensing area Y (mm)
15.0 10.0 5.0 0.0 5.0 10.0 15.0
PRDCM(L)18-7D /14D
PRDCM(L)18-7DPRDCM(L)18-14D
25.0
23.0
20.0
17.0
15.0
14.0
12.0
11.0
10.0
8.0
6.0
5.0
4.0
2.0
Sen
sing
dis
tanc
e X
(mm
)
Left ← Center → Right
Sensing area Y (mm)
20.0 15.0 10.0 5.0 0.0 5.0 10.0 15.0 20.0
PRDCM(L)30-15D /25D
PRDCM(L)30-15DPRDCM(L)30-25D
8.0
7.0
6.0
5.0
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
Sen
sing
dis
tanc
e X
(mm
)
Left ← Center → Right
Sensing area Y (mm)
6.0 4.0 2.0 0.0 2.0 4.0 6.0
PRDCMT12-4D - / PRDCMT12-8D -
PRDCMT12-4D -PRDCMT12-8D -
14.0
13.0
11.0
9.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Sen
sing
dis
tanc
e X
(mm
)
Left ← Center → Right
Sensing area Y (mm)
15.0 10.0 5.0 0.0 5.0 10.0 15.0
PRDCM(L)T18-7D - / PRDCM(L)T18-14D -
PRDCM(L)T18-7D -PRDCM(L)T18-14D -
25.0
23.0
20.0
17.0
15.0
14.0
12.0
11.0
10.0
8.0
6.0
5.0
4.0
2.0
Sen
sing
dis
tanc
e X
(mm
)Left ← Center → Right
Sensing area Y (mm)
20.0 15.0 10.0 5.0 0.0 5.0 10.0 15.0 20.0
PRDCM(L)T30-15D - / PRDCM(L)T30-25D -
PRDCM(L)T30-15D -PRDCM(L)T30-25D -
PRDCM Series
D-52 D-PB
When using DC 2-wire type proximity sensor, the load must be connected otherwise internal components may be damaged. The load can be connected to either wire.
[ ]Vs: Power supply,Ioff: Return current of load,
Io: Min. action current of proximity sensor,P : Number of Bleeder resistance watt
VsR ≤ Io-Ioff
(kΩ)
Vs2
P > R
(W)
Please make the current on proximity sensor smaller than the return current of load by connecting a bleeder resistor in parallel.※W value of Bleeder resistor should be bigger for proper heat dissipation.
Load connections
In case of the load current is small
Proper Usage
DC 2-wire type
Parallel B
(unit: mm)
When several proximity sensors are mounted close to one another a malfunction of the may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors as below chart indicates.
When sensors are mounted on metallic panel, you must prevent the sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as below chart indicates.
ModelItem
PRDCMT12-4D -PRDCM(L)12-4D
PRDCMT12-8D -PRDCM(L)12-8D
PRDCM(L)T18-7D -PRDCM(L)18-7D
PRDCM(L)T18-14D -PRDCM(L)18-14D
PRDCM(L)T30-15D -PRDCM(L)30-15D
PRDCM(L)T30-25D -PRDCM(L)30-25D
A 24 48 42 84 90 150B 24 36 36 54 60 90ℓ 0 11 0 14 0 15Ød 12 36 18 54 30 90m 12 24 21 42 45 75n 18 36 27 54 45 90
Face to Face
A
ℓ
Ød
ℓ
Mutual-interference & Influence by surrounding metals
m
ℓ
n
< DC 2-wire type >
+-
Brown
Blue
< DC 2-wire type >
Load
Load
24VDC+-
Brown
Blue
VsBleeder resistor (R)+
-
Brown
Blue
Load