26
Siemens Industry Online Support Answers for industry. STARTER: USB connection with SINAMICS G120 STARTER, SINAMICS G120 FAQ January 2014

STARTER, SINAMICS G120 FAQ y January 2014 - Siemens · Siemens Industry Online Support Answers for industry. STARTER: USB connection with SINAMICS G120 STARTER, SINAMICS G120 FAQ

Embed Size (px)

Citation preview

Siemens Industry Online Support

Answers for industry.

STARTER: USB connection withSINAMICS G120

STARTER, SINAMICS G120

FAQ January 2014

Table of contents

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 2/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Table of contents1 Preconditions for an online connection between STARTER and

SINAMICS G120 via USB ................................................................................... 3

2 What do I do if …? ............................................................................................. 4

A. after installing/updating STARTER, I cannot establish anonline connection via USB? .................................................. 4

B. after "withdrawing" and "inserting" the USB cable, a USBconnection can no longer be established? ........................... 6

C. after installing/updating STARTER, I cannot establish anonline connection via USB, however the registry entries areOK? ....................................................................................... 8

3 Additional information ... ................................................................................ 11

D to go online with STARTER via USB .................................. 11Select and install the PG/PC interface "S7USB"................................ 11Setting the access point. .................................................................... 12Activate driver installation................................................................... 13Select accessible nodes ..................................................................... 14Load the hardware configuration into the project ............................... 15E regarding series commissioning with the same Control Units17F regarding series commissioning with various Control Unit

versions, offline/online ........................................................ 20Version upgrade in the project, offline ................................................ 20G regarding the online connection via USB after a device has

been replaced and different serial numbers. ...................... 23Open the project and select accessible nodes................................... 23

Preconditions for an online connection between STARTER andSINAMICS G120 via USB

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 3/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

1 Preconditions for an online connectionbetween STARTER and SINAMICS G120via USB

The latest version of STARTER (V4.3.3) must be installed.The CU (Control Unit) is connected to the PC USB port using the specified USBcable or USB interface cable.

Table 1

Order number (MLFB) Description Entry ID

6SL3255-0AA00-2CA0 SINAMICS G120 PC CONVERTERCONNECTION KIT -2 3M USB CABLE FORCONTROL UNITS CU230P-2 CU240B-2,CU240E-2 AND SINAMICS G120C

35068034

6SL3555-0PA00-2AA0 USB INTERFACE CABLE FORCOMMISSIONING ET 200PRO FC,SINAMICS G110D, G120D AND SIRIUSM200D 2.5 M LONG INCLUDING DRIVERCD

35068235

NOTE This FAQ is valid only for WINDOWS XP Computer

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 4/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

2 What do I do if …?A. after installing/updating STARTER, I cannot establish an online connection

via USB?

Countermeasure/remedy: Close STARTER Open the registry with "regedit" Open the folder

HKEY_LOCAL_MACHINE\SOFTWARE\SIEMENS\SINEC\LogDevices\S7USB If the entry is missing, the content should be displayed as follows

Fig. 1 Incomplete registry entry

Delete the S7 USB folder Open STARTER Connect the USB cable to the CU. The system creates a new "S7USB" folder

with the following content. Depending on the software packages installed, thefollowing syntax should be displayed in "S7USB". If this is not the case, thenthe STARTER software should be installed again.

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 5/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 2 Complete registry entry of deleting the "S7USB" folder

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 6/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 3 Complete registry entry of deleting the "S7USB" folder

B. after "withdrawing" and "inserting" the USB cable, a USB connection can nolonger be established?This problem depends on which Intel chip was installed for the USB host controller;it only occurs under Windows XP and the "Intel 5 Serie 3400" chipset. This problemis manifested by the USB port freezing in the device manager. The SINAMICSG120 is no longer detected after inserting the USB cable. Further, it is no longerpossible to detect the MMC card in the SINAMICS G120.

Countermeasure/remedy: Reboot the computer,

or Upgrade to WIN7 64 bit

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 7/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 4 Intel USB host controller

Fig. 5 SIMATIC USB installed by S7DOS

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 8/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 6 If the USB cable is inserted at the Control Unit, then the driver is installed inthe SIMATIC USB device as "SINAMICS G120".

C. after installing/updating STARTER, I cannot establish an online connectionvia USB, however the registry entries are OK?

Countermeasure/remedy:1. Check the registry entries.2. Upgrade the operating system to WIN7 64bit

Check the registry entries: Close STARTER Open the registry with "regedit" Open the folder

HKEY_LOCAL_MACHINE\SOFTWARE\SIEMENS\SINEC\DefDevices\DefaultLogDevices\S7USB

The correct content of the registry entry should look like this:

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 9/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 7 Correct registry entry

Open the folderHKEY_LOCAL_MACHINE\SOFTWARE\SIEMENS\SINEC\LogDevices\S7USB

The correct content of the registry entry should look like this:

What do I do if …?

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 10/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 8 Correct registry entry

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 11/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

3 Additional information ...D to go online with STARTER via USB

1. Open STARTER2. Create a project3. Select „S7USB“ in the PC/PG Interface.

Proceed as follows if the "S7USB" interface is not installed:

Select and install the PG/PC interface "S7USB"Fig. 9 Selecting and installing the interface

Fig. 10 The "S7USB" interface is installed

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 12/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Setting the access point.For USB, the point-to-point "DEVICE (STARTER, SCOUT)" must be selectedFig. 11 Setting the access point.

Additional information on the topic: FAQ Entry ID: 67474312

Connect the Control Unit to the PC/notebook using the USB cableIt can occur that the USB driver is only installed now

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 13/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Activate driver installationFig. 12 Activate driver installation

Exit driver installationFig. 13 Exit driver installation

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 14/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Select accessible nodesFig. 14 Accessible nodes

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 15/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Load the hardware configuration into the projectFig. 15 Load the HW Config

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 16/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Close the "Online/offline comparison" windowFig. 16 Online/offline comparison

Online status – symbol is greenFig. 17 Online status

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 17/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

E regarding series commissioning with the same Control Units4. Open STARTER5. Open project6. Set the PC/PG interface on the USB7. Accessible nodes – nodes found8. Click on online icon

Open the project and select accessible nodesFig. 18 Open the project

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 18/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Activate the online connection via the iconFig. 19 Online

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 19/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Connect to the target deviceFig. 20 Connect

The SINAMICS G120 is now connected with the PC/PG, "Online".This is marked GREEN in the project tree.

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 20/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 21 Online status

F regarding series commissioning with various Control Unit versions,offline/online

Version upgrade in the project, offline Open STARTER Open project offline Set the PC/PG interface on the USB Right click on "Drive device" Click on "Target device", "Upgrade device version/device type" Select "Available device version(s)" Click on "Upgrade" Click on "Yes" A confirmation note is displayed once the operation has been successfully

completed.

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 21/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Open the project offlineFig. 22 Open the project "OFFLINE"

Upgrade the firmware in the projectFig. 23 Sequence when upgrading the firmware in the project

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 22/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 24 Select upgrade version

Fig. 25 Note: all STEP 7 applications must be closed (confirm with "Yes").

Fig. 26 The firmware upgrade has been successfully completed

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 23/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

G regarding the online connection via USB after a device has been replacedand different serial numbers.

Note After a node has been replaced, the serial number (of theSINAMICS G120) is checked when a connection is beingestablished. In this case, when establishing the connection via USB,problems can be encountered.

Open STARTER Open the project Set the PC/PG interface on the USB Accessible nodes – nodes found Click on online icon

Open the project and select accessible nodesFig. 27 Select accessible nodes

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 24/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Activate the online connection via the iconFig. 28 Online

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 25/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Connect to the target deviceFig. 29 Connect

The SINAMICS G120 is now connected with the PC/PG, "Online".This is marked GREEN in the project tree.

Additional information ...

USB connection with SINAMICS G120; ID: 85574448

Version 1.1; FAQ-01PAQUW2 14.01.2014 26/26

Cop

yrig

htSi

emen

sAG

2013

Allr

ight

sre

serv

edFA

Q-0

1PAQ

UW

2_ST

ARTE

R_V

4-3-

x_U

SB-c

onne

ctio

n-is

sues

_V1-

1_en

.doc

x

Fig. 30 Online status

The new Control Unit with serial number can be seen in parameter p7758Figure 31