SMP - 7000H USER’S MANUAL

YUMYUNG ENGINEERING CO., LTD.

Page 2: smp-7000H

Table of Contents

YUMYUNG

1.Introduction ......................................................................................................................1 1.1 Features....................................................................................................................1

2.Product Specifications ..................................................................................................2

3.Front Plate Descriptions ...............................................................................................3

4.System Processing Methods .......................................................................................4

5.RPM & Time Setting Flow chart ..................................................................................5

6.ENG & T/C Voltage Output, Software Group Setting Flow Chart .......................6

Page 3: smp-7000H

SMP - 7000H USER MANUAL

1 YUMYUNG

1. Introduction SMP-7000H has been designed by Microprocessor control type, it can

operating have the stability, simple operation, easily expansion and com-

pact view atc.

1.1 Features

1) Stability

- It is reliable operation by Microprocessor control

- Power supply have the noise filter

- PCB has been designed with separate line as like power

line and signal line for EMI protection.

- Unit case has made by aluminium material

2) Simple operation

- It has applied the one- touch operation type with MODE and

ENT key

3) Easily Operation

- It has spare terminal of input/output signal and software margine

also.

4) Compact view (outside)

- It have many functions with compact designed by micom practice.

5) Easily A/S

- It can be changed the trouble PCB only of several PCB's

- Terminal blocks has been designed separately with main unit.

Page 4: smp-7000H

SMP - 7000H USER MANUAL

2 YUMYUNG

2. Product Specification

Specification

Power Source DC 24V, ±20%

Consumption Power 5.04W (Max. 220mA)

Display Method Engine RPM Display : FND

Relay Output Status Display : LED

Accuracy FS. ±0.2%

Display Range 0 ~ 9999

Setup Digital Setting

INPUT

ENG Speed

Sensor Type: SPS-02 Sensor (L27/38 : SPS-01 Sensor)

+UB(10 ~ 40V)-1.8V Square Wave

Teeth & RPM Teeth: 1EA ~ 500EA

0 ~ 1200 RPM

T/C Speed

Sensor Type: KBB Sensor (Magnetic Pick-up)

Sign wave

RPM 0 ~ 60000RPM (0~2kHz)

Power Source for Sen-sor

ENG +UB=12V MAX (300mA)

T/C 12V MAX (300mA)

Frequency Range ENG 0~10kHz

T/C 0~2kHz (L27/38: 0~1kHz)

OUTPUT

Voltage Output ENG 0 ~ 6V

T/C 0 ~ 6V

Frequency Output ENG 0 ~ 10kHz (+12V, Square Wave)

Relay Driver Output

FET Driver MAX=100V, 500mA

1. Tacho fail (L27/38 Pickup Fail), (L32/40 Pickup Fail)

2. Safety Start

3. Running

4.Over Speed

5. Fuel Limit (L27/38: Start Limit), (L32/40: RPM)

6. Spare (L27/38: JET SYS), (L32/40: Spare)

Applied Engine H25/33, H21/32, L27/38, L32/40

Insulation Resistance Over than 100MΩ

Operating Temperature -10 ~ +65℃

Storage Temperature -25 ~ +70℃

Operating Humidity Less than 95% RH (Non Condensing)

Dimension 118(W) X 130(H) X 60(D) (UNIT: mm)

Weight 720g

Case Material Steel

ITEM

Page 5: smp-7000H

SMP - 7000H USER MANUAL

3 YUMYUNG

3. Front Plate Descriptions

Number Name Descriptions

SAFE START LED LED is for indication of the condition of ready to start

TACHO FAIL LED

After input of fail or start of Pick-up sensor, during the

time of safety start, if RPM is not input LED shall be

lighted.

(it is for warning to inform of abnormal operation

condition)

ENG RUN LED LED is for indication of the condition of engine run.

OVER SPEED

LED

In the condition the speed limit value is established, the

LED is lighted when the speed exceeds the speed limit

value.

FUEL LIMIT LED is for indication of the Fuel limit when engine start.

② RPM Display RPM of engine in running is indicated by digital number

③ Setting Button Each Button used for system setup when RPM display for all relay output

and, Time value, ENG. RPM or T/C RPM output voltage change.

Relay Driver

Output

/Voltage Output

Relay Driver Output terminal and Engine or T/C RPM output terminal.

ENG. Status LED

Page 6: smp-7000H

SMP - 7000H USER MANUAL

4 YUMYUNG

4. System Processing Methods

● Engine RPM Processing Method

Frequency (Hz) signal of engine pick-up is transmitted from

pick-up installed at Cam Gear. The proportional value and

calculating method of rotation number (RPM), frequency(Hz) and

voltage (V) are as follows.

Note: L23/30 needs 70 cam gears and L28/32 needs 74 cam gears. However, L23/30 and L28/32 should be calculated with 35 and 37 cam gears respec-tively.

● T/C RPM Processing Method

Frequency (Hz) signal of T/C Speed Pick-up is transmitted from Pick-up

installed at T/C Inside. The proportional value and calculating method of

rotation number (RPM), frequency (Hz) and voltage (V) are as follows.

Note: Number of hole for T/C Pick-up signal in medium size engine is

one.

ITEM H21/32 H25/33

Hz 1200(RPM) X 286(Gear) /60sec = 5720(Hz) 1200(RPM) X (282(Gear) /60sec = 5640(Hz)

RPM 0 ~ 1000 RPM 0 ~ 1000 RPM

Output 0 ~ 6V 0 ~ 6V

ITEM T/C MAX. RPM : 60000

Hz 60000(RPM) X (2Hole) /60sec = 2000(Hz)

RPM 0 ~ 60000 RPM

Output [V] 0 ~ 6V

Page 7: smp-7000H

SMP - 7000H USER MANUAL

5 YUMYUNG

5. RPM & Time Setting Flow chart

Enter the Setting Mode

Press M key during 5sec

Save the setting value

Mode change

Setup the OVER SPEED

Setup the TACHO FAIL

Running RPM Setting

Running Delay Time Set-

OFF RPM Set-

Save the setting value

Setup the Engine Run RPM

Setup the Engine Run Delay Time

Setup the Engine Run Off RPM

Mode change

Save the setting value

Save the setting value

Save the setting value

Mode change

Mode change

Exit the Setting Mode

Setup the FUEL LIMIT

Save the setting value

Mode change

Safe Start Delay Time Set-

Safe Start OFF RPM Set-

Setup the Delay Time

Save the setting value Mode change

Setup the OFF RPM

Save the setting value

Mode change

Page 8: smp-7000H

SMP - 7000H USER MANUAL

6 YUMYUNG

6. ENG & T/C Voltage Output, Software Group Setting Flow Chart

Enter the Setting Mode

Press M key with down key during 5sec

Save the setting value

Setup the ENG. Voltage Output Zero

Setup the ENG. Voltage Output Span

Mode change

Save the setting value

Exit the Setting mode

Setup the Software Group

Save the setting value

Mode change

Save the setting value

Setup the T/C Voltage Output Zero

Setup the T/C Voltage Output Span

Mode change

Save the setting value

Mode change