7
TITLE SHEET T-1 DN72XC020 DN72XC020M17.1 CO0190 - PHASE 1A 4490 E BLANEY ROAD PEYTON, CO 80831 W I R E L E S S 540 W. MADISON ST. 17TH FLOOR CHICAGO, IL 60661 www.sacw.com 312.895.4977 A NOKIA COMPANY ä ä LETS America, Inc. · · R Call before you dig. below. Know what's TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN COLORADO, CALL COLORADO 811 TOLL FREE: 1-800-922-1987 OR www.co811.org COLORADO STATUTE REQUIRES MIN OF 2 WORKING DAYS NOTICE BEFORE YOU EXCAVATE NORTH NORTH CO0190-PHASE 1A DN72XC020 DN72XC020M17.1 4496 E BLANEY ROAD PEYTON, CO 80831 EL PASO COUNTY PIKESPEAKREGIONALBUILDINGDEPARTMENT 260'-0" SELF-SUPPORT TOWER MWDO PROJECT SITE NAME: SITE NUMBER: AUGMENT ID: ADDRESS: JURISDICTION: SITE TYPE: PROGRAM TYPE: SITE SITE 10/27/17

SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

  • Upload
    dinhdan

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

TITLE SHEET

T-1

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

·

·

R

Call before you dig.below.Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN COLORADO, CALL

COLORADO 811

TOLL FREE: 1-800-922-1987 OR

www.co811.org

COLORADO STATUTE

REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE

NORTH NORTH

CO0190-PHASE 1A

DN72XC020

DN72XC020M17.1

4496 E BLANEY ROAD

PEYTON, CO 80831

EL PASO COUNTY

PIKES PEAK REGIONAL BUILDING DEPARTMENT

260'-0" SELF-SUPPORT TOWER

MWDO PROJECT

SITE NAME:

SITE NUMBER:

AUGMENT ID:

ADDRESS:

JURISDICTION:

SITE TYPE:

PROGRAM TYPE:

SITE

SITE

10/27/17

Page 2: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

X

X

X-X

X

X-X

X

X-X

NEW ANTENNA

EXISTING ANTENNA

EXISTING MW ANTENNA

NEW MW ANTENNA

GROUND ROD

GROUND BUS BAR

MECHANICAL GRND. CONN.

CADWELD

GROUND ACCESS WELL

ELECTRIC BOX

TELEPHONE BOX

LIGHT POLE

FND. MONUMENT

SPOT ELEVATION

SET POINT

REVISION

GRID REFERENCE

DETAIL REFERENCE

ELEVATION REFERENCE

SECTION REFERENCE

GROUT OR PLASTER

EXISTING BRICK

EXISTING MASONRY

CONCRETE

EARTH

GRAVEL

PLYWOOD

SAND

STEEL

WOOD CONT.

WOOD BLOCKING

CENTERLINE

P PROPERTY/LEASE LINE

MATCH LINE

WORK POINT

GROUND CONDUCTOR

TELEPHONE CONDUIT

ELECTRICAL CONDUIT (POWER)

COAXIAL CABLE

FIBER CABLE

TELCO/ELECTRICAL CONDUCTORS

FIBER/ELECTRICAL CONDUITS

CHAIN LINK FENCING

CAT5E/WAVEGUIDE

C

L

L

NEW IBR 1300

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

GENERAL NOTES,

LEGEND &

ABBREVIATIONS

T-2

10/27/17

Page 3: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

XXXXXXXX

XX

XX

XX

XX

X

X X X X X X X X X X X X X

XX

XX

XX

XX

X

XX

X

XX

XX

X X X

XX

OVERALL &

ENLARGED SITE

PLANS

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

A-1

NORTHNORTH

10/27/17

Page 4: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

EXISTING & NEW

ANTENNA LAYOUTS,

MOUNTING &

SCHEDULE

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

A-2

NORTH

NORTH

±

10/27/17

Page 5: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

EXISTING & NEW

ELEVATIONS

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

A-3

10/27/17

Page 6: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

EQUIPMENT

DETAILS & SINGLE

LINE DIAGRAM

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

A-4

10/27/17

Page 7: SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · a nokia company ä ä lets america, inc. ... and bts manufactures practices for grounding requirements. ground coax shields

SCHEMATIC

GROUND PLAN &

DETAILS

ANTENNA GROUND BUS BAR NEAR ANTENNA MOUNTS WITH COAX GROUND KIT.

EQUIPMENT GROUND BUS BAR NEAR EQUIPMENT WITH COAX GROUND KIT.

#6 AWG GROUND FROM ANTENNA GROUND BUS BAR TO TIE INTO EXISTING

GROUNDING SYSTEM (TYP OF (2) PLACES).

#6 AWG GROUND FROM ANTENNAS TO ANTENNA GROUND BUS BAR.

#6 AWG GROUND FROM RADIOS TO ANTENNA GROUND BUS BAR.

#6 AWG GROUND MMBTS GROWTH CABINET TO NEW EQUIPMENT GROUND BUSS BAR.

#6 AWG GROUND FROM NEW GROUND BUS BAR TO TIE INTO EXISTING GROUNDING

SYSTEM (TYP OF (2) PLACES).

GROUND FROM CABINETS TO NEW EQUIPMENT GROUND BUS BAR.

1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION

MAY VARY DUE TO SITE SPECIFIC CONDITIONS.

2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS

USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS, FOLLOW ANTENNA

AND BTS MANUFACTURES PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX

SHIELDS AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES.

3. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND.

4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER

OPERATIONAL TESTING WILL BE WITNESSED BY AN SPRINT REPRESENTATIVE.

5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY

WITH ALL REQUIREMENTS OF GROUNDING STANDARDS.

6. CONTRACTOR TO ABIDE BY ALL SPRINT SAFETY STANDARDS DURING SITE CONSTRUCTION.

7. CONTRACTOR SHALL REFER TO SPRINT STANDARDS FOR GROUNDING CONNECTIONS &

INSTALLATION METHODS.

8. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND

RECEIVE APPROVAL OF DESIGN BY AUTHORIZED SPRINT REPRESENTATIVE, PRIOR TO

INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND

RING.

9. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING

SYSTEM DUE TO SITE SOIL CONDITIONS.

10.GROUNDING ROD NOTES (WHERE APPLICABLE)

11.ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND

SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL. UTILIZING THE FALL OF POTENTIAL

METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST

AND CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING LINE, GRAPHED OUT TO

SHOW THE PLATEAU.

12.POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO

THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE

COUNTERPOISE IS ISOLATED. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS

ISOLATED FROM THE A/C SYSTEM GRIDS AND EXISTING COMMUNICATIONS FACILITY.

DN72XC020

DN72XC020M17.1

CO0190 - PHASE 1A

4490 E BLANEY ROAD

PEYTON, CO 80831

W I R E L E S S

540 W. MADISON ST.

17TH FLOOR

CHICAGO, IL 60661

www.sacw.com

312.895.4977

A NOKIA COMPANY

ä

ä

LETS America, Inc.

G-1

1

2

3

4

5

6

7

8

10/27/17