52
© SCHRACK SECONET AG • M. Schwantner • B-PPT-040EN.ppt• V 1.1 Schrack Seconet Fire Alarm Systems. Sales Training. Schrack Seconet Fire Alarm Systems. FIRE ALARM

Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

  • Upload
    others

  • View
    22

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Sales Training.

Schrack Seconet Fire Alarm Systems.

FIRE ALARM

Page 2: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral IP system family.

Common hardware platform

Uniform firmware and PC tools

For all system sizes

Intelligent network structurs

Hard- & software redundancy

Interfaces BACnet, OPC, MODBUS, etc.

Intuitive operating concept

Operation in national languages

Forward and backward compatibility

Made in Europe

Page 3: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral IP system family.

Modular, decentralised construction

Hardware & Software redundancy

TCP/IP interface

can be networked

X-LINE: up to 16 Loops

up to 4.000 elements

Multi zone extinguishing panel

Compact, decentralised construction

Software-redundancy

TCP/IP interface

can be networked

X-LINE: up to 4 Loops

up to 250 elements per loop

Single zone extinguishing panel

MX CX

Basic version

Software-redundancy

TCP/IP interface

can be networked

X-LINE: 1 Loop

up to 250 elements

BX

Page 4: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral IP MX.

fully redundant and modular fire alarm control panel

decentralised system design

could be networked from a single control panel up to large systems by using copper or fiber connections

up to 16 loops (4000 elements) per control panel

Event memory for up to 65,000 messages

freely programmable inputs/outputs and algorithms

remote access via network or internet

various communication protocols for connection to management systems and higher-level systems

100% compatible to former systems

multi-zone extinguishing panel

MX

Page 5: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

B5-NET4-485 Network Module

Double security thanks to real redundancy.

Two identical systems work constantly in "Hot-Stand-By-Operation"

Not only the microprocessor structure, but all other system structures, components and parts are also duplicated

The occurrence of a fault in the active section of the system causes the system to be automatically switched over to the second side of the system and for a system fault to be indicated

All functions, such as detection, triggering of alarms, plain text indication and controlling of fire alarm devices etc. remain unaffected

Page 6: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Membrane keypad and plain text display currently in more than 20 languages

Integral MAP operating panel.

Page 7: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Fire alarm control panel Integral IP MXF.

X-LINE

Fire alarm device

Fire alarm routing equipment

Fire brigadekey safe

Fire brigade panelacc. to DIN 14661

MMI-BUS

not monitored alarm devicesfire actuation devices

triggering relay bus

monitored alarm devices

monitored inputsconventional detector zones

modernisation monologue technology

SecoLOG

ComBOX

External printers

Voice alarm

Telephone switchboards, Pager, ESPA

SecoLOG IP

RemoteMESSAGE

RemoteACCESS

VirtualMAP

Ethernet

LAN network

EPI-BUS

B5-BAF

B5-DXI2

B5-MRI16

B5-OM8B3-IM8

B3-MTI8

B3-USI4

B5-LANB5-NET2-FXMB5-NET2-FXS

B5-NET2-485B5-NET4-485

Page 8: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multi-zone extinguishing panel Integral IP MXE.

X-LINE

MMI-BUS

B5-BAF

B5-DXI2

not monitored alarm devicesfire actuation devices

triggering relay bus

B5-MRI16

B5-OM8

monitored alarm devices

Monitored inputs

Manual triggering deviceVentile

Conventional detector zones

B3-IM8

Stop-button

flood

SecoLOG IP

RemoteMESSAGE

RemoteACCESS

VirtualMAP

Ethernet

LAN network

EPI-BUS

B5-LANB5-NET2-FXMB5-NET2-FXS

B5-NET2-485B5-NET4-485

blocking device

switchoperation/reserve

pressure switch

loss

Page 9: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Fire alarm control panel Integral IP CXF.

X-LINE

Fire alarm device

MMI-BUS

not monitored alarm devicesfire actuation devices

SecoLOG

ComBOX

External printer

Voice alarm

Telephone switchboards, Pager, ESPA

SecoLOG IP

RemoteMESSAGE

RemoteACCESS

VirtualMAP

Ethernet

LAN network

EPI-BUS

B6-BAF

B6-DXI2

B6-EIOB4-USI

B6-LXI2

B5-NET2-FX

B6-NET2-485

X-LINE

B6-LAN

Conventional detector zones

monitored alarm devices

monitored inputs

B6-REL5

on main control unitB6-BCU-X2

on main control unitB6-BCU-X2

on main control unitB6-BCU-X2

Fire alarm routing equipment

Fire brigadekey safe

Fire brigade panelacc. to DIN 14661

Page 10: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Single-zone extinguishing panel Integral IP CXE.

X-LINEB6-DXI2

on main control unitB6-BCU-X2

MMI-BUSB6-BAF

on main control unitB6-BCU-X2

EPI-BUS

not monitored alarm devicesfire actuation devices

B6-REL5on main control unit

B6-BCU-X2

B6-EIO

monitored inputs

blocking device

monitored alarm devices

Ventile

conventional detector zones

switchoperation/reserve

pressure switch

lossManual triggering device

Stop-button

flood

Page 11: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral IP BX.

X-LINEB7-DXI

on main control unitB7-BCU-X1

B7-BAF

EPI-BUS

Fire alarm device

on main control unitB7-BCU-X1

B7-LANon main control unit

B7-BCU-X1

SecoLOG IP

RemoteMESSAGE

RemoteACCESS

VirtualMAP

Ethernet

Alarm routing equipment

Page 12: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Supports all Integral IP system family control panels

Suitable for configuring all sizes of systems as well as SecoNET networks

Dongle-protected

Compatible with all Windows operating systems from Windows 2000

Graphically clear user interface, ergonomic and intuitive to learn

Integral Software.

Page 13: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Clear and user-friendly operation in message and command direction

IP interface for networking using existing LAN networks

Compatible with all Schrack fire alarm systems - can also be integrated subsequently

Multi-user enabled and approved in accordance with ÖNORM F 3003

Managementsystem SecoLOG IP Fire.

Page 14: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

IP Applications for Fire Alarm Systems.

Page 15: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral IP Applications - Overview.

Get informations e.g. Analysis of the current status of a control panel before a service or maintenance takes place. Receipt of programmed messages (alarms, faults, etc.)

Operating the systeme.g. Remote operation of the control panel or remote help during operating the system

ProgrammingSupport during system start-up or assistance in troubleshooting or reprogramming

Page 16: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral over IP – Applications & Benefits.

Use of existing networks(Intranet, Internet)

Standard interfaces (LAN, IP)

Central Web-applications (Cloud Service)

„Anywhere @ Anytime“ - independent of location & always available

Messaging: Panels send information's automatically to responsible persons

Immediate intervention of specialists possible from anywhere

Central control and centralized support for any number of panels

Any many more

Page 17: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral IP Applications - Overview.

Page 18: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral over IP – PC terminal devices.

RemoteMESSAGEAutomatic messages from one or several control panels to a Server and visualisation on one or several PCs.

Integral MAILInformation: the control panels sends event-based emails to one or more recipients

Page 19: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral over IP - PC terminal devices.

Integral VirtualMAP

Indicates information about the current state of the system, e.g. before a maintenance takes place, or is used for receiving messages (alarms, faults, etc.)

Performing operation procedures, as they were possible only from stationary facilities up to now (control centre, doorman, etc.) or

Online-Help when the supervising staff has difficulties during operation

IAC RemoteACCESSSupport during start-up procedure, assistance in troubleshooting, remote reprogramming

Page 20: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral over IP - Mobile devices.

indication and operation of one or more fire alarm panels independent of location of the user

Indicates information about the current state of the system, e.g. before a maintenance takes place, or is used for receiving messages (alarms, faults, etc.)

Performing operation procedures, as they were possible only from stationary facilities up to now (control centre, concierge, etc.) or

Remote help when the supervising staff has difficulties during operation

Active information via Push-Notifications

Geodata query

Page 21: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Digital, interactive loop communication and data backup

Integrated short circuit isolator in each element

Up ot 250 elements per loop

Up to 3.500 m loop length

Start-up time <100s when fully equipped

Monitoring of hazardous areas via loop-module and stub-line

Intelligent integration of special detectors

universal or individual parameter sets programable

Information from the connected special detector systems, incl. forwarding of the information to the management system

Inputs and outputs are freely programmable or can be assigned by means of parameter sets

Intelligent implementation of power supply devices

High degree of backward compatibility

Integral X-LINE.

Page 22: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Integral X-LINE.

BX-UPI

X-LINE module2 monitored inputs

1 Optokoppler input1 relay output

LKM 531

MCP 535X MCP 545X BX-APIBX-SBL501

BX-SBL502

BX-SOL

BX-FOLMTD 533X

BX-ESL

BX-O1

BX-IM4BX-I2

BX-RGW BX-REL4BX-O2I4

BX-IOM

BX-AIM

BX-OI3

XLM35

Parallel indicator

Multisensordetector

Ventilation duct detector

Manual callpoint

Manual callpoint

Base sounder Base sounderPlatform sounder

Loop siren

Loop flash light

X-LINE module for special detectors

X-LINE module1 primary line f.detector zones

X-LINE module1 monitored output1 monitored input

X-LINE module2 relay output

4 monitored inputs

X-LINE module4 relay outputs

X-LINE modulefor radio detectors

X-LINE module1 Optokoppler input

1 monitored input

X-LINE module4 monitored inputs

X-LINE module1 relay output

X-LINE moduleEnd-position switch

Integral X-LINEmax. 3.500 m lengthmax. 250 elements

Page 23: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

CUBUS technology - New standards in detection.

Page 24: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

New standards in detection.

Multisensor detectorsfor all applications

CUBUS technologyfor intelligent detection

Compliant with all new EN standards prEN 54-26:2008

Point fire detectors using carbon monoxide sensors

prEN 54-30:2009 Point detectors using a combination of carbon monoxide and heat sensors

prEN 54-31:2012Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors

prEN 54-29:2009 Point detectors using a combination of smoke and heat sensors

Page 25: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

CUBUS Technology.

The detector adjusts itself automatically according to its ambient conditions other detectors have to be configured manually after installation

The detector monitors the ambient temperature as well as the relative increase of temperature and automatically calculates the optimal smoke sensitivity for each location

Thanks to CUBUS technology:

Costly deceptive alarms can be reduced

At the same time a fast and reliable detection is guaranteed

Evtl. Link auf neuen CUBUS Film !!

Page 26: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

The heat sensor can be configured in to standard classes A1, A2 and B (for special areas of application also with the index R or S) in accordance with EN 54-5

Class index „S“ is particularly well suited for use where deceptive values should be filtered out (e.g. in boiler houses or kitchens)

Class index „R“ for areas with low ambient temperatures (e.g. unheated buildings)

The three standard classes combined with the indexes R or S give a total of 9 variations in order to ensure optimal adaptation to surrounding conditions

The principle of heat classes

Configurable Heat Classes.

Page 27: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Up to 250 pcs MTD 533X on one loop with up to 3.500 m length connectable

Serial number for unique identification

Fire zones can be defined as desired„Virtual Loop“

Controlling of fire actuations also possible without forwarding an alarm and during the detector is switched off

Intelligent test function for economical detector test

Mechanically and electronically forwards and backwards compatible

Automatic short circuit detection during startup

Multiple sensor detector MTD 533X.

Page 28: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Constant operational safety thanks to constant self tests

Integrated short circuit isolator

Parameterisable heat sensor

Parameterisable alarm output

Parallel indicator connectable

Pre-alarm levels can be set at 30% or 75% a pre-alarm signal can be sent to the fire alarm control panel

History memory for all detector data and events

Monitoring of the contamination state

Approved acc. to EN 54-5, EN 54-7, EN 54-17 and Construction Products Directive (CPD)

Base

Smoke chamber

Heat sensor

LED light beam

Multiple sensor detector MTD 533X.

Page 29: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

The highest degree of safety for detection for all sizes of smoke particle thanks to an optimised inflow behaviour

Smoke detection also always involves temperature evaluation

In the event of a rapid increase in temperature fires are also detected without the formation of smoke

Smoke and temperature sensors can be activated and disabled separately

Automatic changeover possible based on time of day or clock time

Multiple sensor detector MTD 533X.

Page 30: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multiple sensor detector CMD 533X - Technology.

Detects the fire characteristics smoke, heat and carbon monoxide (CO)acc. to EN54-5, EN54-7, EN54-26, EN54-29, EN54-30 & EN54-31

CUBUS+ technology for automatic sensitivity adjustment (smoke detection supported by heat & CO)

Adjustable technical CO alarm acc. to EN 50291-1 from 20 to 320 ppm

Ambient CO-concentration can be read out

Fire characteristics acc. EN54 and technical CO alarm can be activated individually

Durable CO-cell: life-time up to 8 years

Compensation of detector pollution

Page 31: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multiple sensor detector CMD 533X - Benefits.

One detector for all applications

Detects smoke, heat and carbon monoxide (CO)

Ready for all future tenders – fulfils all EN 54-standards

Very flexible if the use of the room changes

Secure detection

Prevents deceptive alarms caused by dust and steam

Wide range of fire detection (test fires acc. to EN 54)

Added value detection

Early protection against suffocation

Ambient CO-concentration can be read out

Automatic triggering of controls at a configurable level of CO-concentration

Page 32: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multiple sensor detector CMD 533X - Applications.

For a rapid and secure detection of all types of fire in applications with a high risk of deceptive alarms:

Kitchens, catering areas, washrooms

Bakeries, carpentry, mechanic workshops, discos, stables, swimming pools

Storage areas, cable trays, suspended ceilings, equipment rooms

Pre-alarm for harmful CO-concentrations

dependent on the duration:

Hotels, Hospitals, Residential and commercial buildings (rooms where people sleep)

Manufacturing plants, boiler rooms, closed garages

Page 33: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multiple sensor detector MTD 533X-S/SP - Technology.

Detects the fire characteristics smoke and heat acc. to EN54-5, EN54-7 & EN54-29

Integrated sound & voice acc. to EN54-3

Four tones: DIN, Slow Whoop, Sweden and continuous tone selectable via the control panel

Three volume levels:92dB (high), 81dB (middle) and 69dB (low)

Simultaneous sounder activation on one loop:approx. 20 (high), 32 (middle) and 60 (low)

Voice output of 12 stored texts in different languages

Synchronized audio and voice output

Voice output of stored texts in different languages

Page 34: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multiple sensor detectors MTD 533X-S/SP - Benefits.

One product for 2 functions

detects smoke and heat

integrated sound & voice

Secure detection

Clearly understandable alarm messages

Reduced product costs

Reduced installation costs

Higher flexibility

Uninterrupted alarm even in case of a failure

Page 35: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Multiple sensor detectors MTD 533X-S/SP - Applications.

For a rapid and secure detectionin applications where acoustic alarm is

required:

Hotels

Schools

Office buildings

Public buildings

Meeting places

Page 36: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Green building door holding magnet BX-MDH.

Page 37: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Door holding magnet BX-MDH.

Directly on the loop

Saves energy costs in full,no continuous current required

No power supply required(permanent magnet)

Integrated monitoring of the door position

High availability through loop technology

Integrated short circuit isolator

Selective activation(individual addressing)

Easy to install – even afterwards

Page 38: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Aspirating smoke detectors

Line type heat detectors

Linear smoke detectors

Flame detectors for hazardous areas

Special detector systems.

Page 39: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Time

Incr

ease

of t

he s

mo

ke c

onc

entra

tion Line-type heat detectors

Smoke aspirating system

Point type detectorsSmoke detector Heat detector

Sensitivity survey of fire detectors.

Page 40: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Aspirating smoke system AirSCREEN ASD 535.

Monitoring of rooms

Warehouses and distribution centers, archives, false ceilings and raised floors, large halls, museums, galleries, theaters, cinemas, cultural heritage, monuments, airports, computer rooms, laboratories and research centers, transformer rooms, clean rooms, cold storage

Monitoring of objects

Telecommunication facilities, high and low voltage distribution centers, computer equipment, CNC controls

Invisible applications

Protection of cultural property, prison cells, etc.

Page 41: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

AirSCREEN ASD 535 - Features.

Sensitivity adjustable from 0.002 to 10 %/m

1 or 2 sampling tubes with separate airflow sensor

Asymmetrical aspirating lines possible with VdS approved calculation software PipeFlow

Perfected smoke detection by means of High dynamic technology

High suction capacity and low noise

IP 54 without additional housing

Optimized aerodynamics for reduced contamination

also suitable for cold store areas

Auto learning-function

Comprehensive system integration

VdS approval in accordance with EN 54-20 (classes A,B,C)

Page 42: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Application fields for line type heat detectors.

Aggressive environments (gases, off gases, salt mist dust, etc.)

Moisture, incl. condensing moisture

Extreme temperatures

where conventional point detectors cannot be used

Outdoor use

Long lengths or large areas with many measuring points like tunnels or car parks

Applications with difficult access after installation, e.g. hollow ceilings

Page 43: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Examples for typical line type heat detector applications.

Road tunnels, rail tunnels, metro tunnels

Car parks, refrigerated storehouses

Industrial object protection / refineries / gas lines and external heating lines

Loading ramps

Cable & energy tunnels

Conveyor systems (e.g. coal coal loading stations, paint shops car industry, etc.)

Disposal operations, recycling plants

43

Page 44: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Line type heat sensor LWM1.

works on the principle of line resistance

4-wire cable

up to 300 m monitoring length

Temperature range: -20 ° C to 50 ° C(with special cable: -60 ° C to 175 ° C)

Detection via maximum temperature or rate-of-rise

Page 45: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Areas of usage for linear smoke detectors.

Large industrial and public buildings, such as

Airports

shopping malls

corporate buildings

underground or railway stations

trade fair halls and warehouses

Garages and hangars

Naves of churches

Page 46: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

SPC-Esender/receiver5 to100 m distanceIP 42

ES 25

ES 50

ES 80

SPC-E

ECO sender/reflector ES 50/25: 2 to 50 m distancesender/reflector ES 80: 10 to 80 m distanceIP 44

ILIA sender/reflector ILIA S/R: 10 to 150 m distancesender/receiver ILIA S/E: 10 to 200 m distanceIP 65

Linear smoke detectors - Overview.

ILIAECO

Page 47: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Areas of usage for flame detectors.

Flame detectors release an alarm, when flames radiation and the typical flicker of flames and embers appear

to avoid deceptive alarms, several sensors are often combined within one housing and are evaluated together

Flame detectors operate in the invisible (ultraviolet or infrared) range and are preferably used in environments where smoke appears or if it is to be expected that a rapid development of open flames will appear in case of a fire.

Page 48: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Flame detector Selection.

hydrocarbon fires

IR UV/IR

non hydrocarbon fires

IR UV/IR UV

Fuels

X3301

3-fach IRMulti IR

X9800

1-fach IRSingle IR

X5200

UV/IR

X5200

UV/IR

X3302

3-fach IRMulti IR

X2200

UV

Page 49: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Flame detectors - Overview.

Multi-IR Flame detector X3301

detects 0,1m² N-Heptan fire in a distance of 63m

3 different IR sensors

µP controlled heated optics

SIL 2 Certification

Applications: Wide areas, spray painting booths, gas turbines

IR Flame detector X9800

detects 0,1m² N-Heptan fire in a distance of 15m

µP controlled heated optics

Applications: Hydrocarbon fires

UV Flame detector X2200

detects 0,1m² N-Heptan fire in a distance of 18 m

Fast response

Applications: Propellants, Munitions, Black powder, TNT, gun powder, sulphur

UV/IR Flame detector X5200

detects 0,1m² N-Heptan fire in a distance of 15m

combines the technologies of X2200 and X9800

Detection of both sensors generate an alarm signal simultaniously

aux.-rel. programmable for UV and/or IR alarm signal

µP controlled heated optics

Applications: Test engine cells, Exhaust test cells, hangars

Page 50: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Audible alarm devices - Overview.

BX-SOLAddressable siren Loop connectionApproval acc. to EN 54-3/-17

BX-SBL 501/502 Addressable base sirenLoop connection Approval acc. to EN 54-3/-17

CS 200 & YO4 & ACWconventional sirensnot addressable additional cabelling requiredconnection via loop module BX-IOM possibleApproval acc. to EN 54-3

BX-APIAddressable base sirenLoop connection Approval acc. to EN 54-3

Page 51: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

EN 54-23 Visual alarm devices.

white or red flashlight

flash rate between 0,5 Hz and 2 Hz

min. illumination of 0.4 lm/ m² [unit = Lux] at each point in the room

min. effective light intensity of 1 cd at max. 500 cd

Page 52: Schrack Seconet Brandmeldesysteme - Metrix Securitymetrixsecurity.com/images/Products/fire detection...Integral IP Applications - Overview. Get informations e.g. Analysis of the current

© S

CH

RAC

K S

ECO

NET

AG

• M

. Sch

wa

ntne

r •

B-P

PT-0

40

EN.p

pt•

V 1

.1

Schrack Seconet Fire Alarm Systems.

Visible alarm devices - Overview.

BX-FOLAddressable flashlight Loop connectionApproval acc. to EN 54-17

V4conventional flashlightnot addressable additional cabelling requiredconnection via loop module BX-IOM possibleApproval acc. to EN 54-3

VTBconventional combined sounder / flashlightnot addressable additional cabelling requiredconnection via loop module BX-IOM possibleApproval acc. to EN 54-3