    www.resol.deThank you for buying a RESOL product.Please read this manual carefully in order to put this controller to the best possible use.

    RESOL DeltaSol® AXMounting

    Connection

    Operation

    Application examples

    manual

    *48000250*

    4800

    0250

  • DeltaSol® AX

    © R

    ESO

    L 06

    255

    delta

    sol_

    ax.m

    onen

    .indd

    | 2

    ContentsImprint ................................................................................2Security devices ..................................................................2Technical data and function survey ..................................31. Installation ...................................................................41.1 Mounting ......................................................................................... 41.2 Electrical connection .................................................................... 42. Functions and Settings ...............................................5 2.1 Micro-switch and potentiometer .............................................. 52.2 Switch-on temperature difference ............................................ 5

    Scope of delivery:• controllerDeltaSol® AX

    (full kit incl. 2 temperature sensors)• sparefuseundercover• accessorybagconsistingofsiliconesealing, fastening

    screwsanddowels,strainreliefclampandscrews• manual

    2.3 Manual operation .......................................................................... 52.4 Maximum temperature limitation ............................................. 62.5 Anti-Freeze protection ................................................................ 62.6 Minimum temperature limitation .............................................. 62.7 Blinking codes ................................................................................ 63. Tips for fault diagnostics ............................................74. Applications of use .....................................................75. Annex: Fault diagnostics .......................................... 10

    Security advice

    Pleasepayattentiontothefollowingsecurityadviceinordertoavoiddangeranddamagetopeopleandproperty.

    Instructions

    Attentionshouldbepaid

    -tothestatutoryprovisionsforpreventionofindustrialaccidents,

    -tothestatutoryprovisionsforenvironmentalprotection,

    -totheHealthandSafetyatWorkAct1974

    - to Part P of the Building Regulations 2005

    - to BS7671 Requirements for electrical installations and relevantsafetyregulationsofDIN,EN,DVGW,TRGI,TRFandVDE.

    This instruction isexclusivelyaddressedtoauthorisedskilled personnel.

    -Onlyqualifiedelectriciansshouldcarryoutelectricalworks.

    -Initial installationshouldbeeffectedbynamedqualifiedpersonnel

    Declaration of conformity

    We, RESOL Elektronische Regelungen GmbH, D-45527Hattingen, declareunderour sole responsibility thatourproduct DeltaSol® AX complies with the following stan-dards:

    EN55014-1EN60730-1

    According to the regulationsof theabovedirectives, theproductislabelledwith :

    89/336/EWG73/23/EWG

    Hattingen,07.07.2006RESOLElektronischeRegelungenGmbH,

    ppa.GeraldNeuse

  • DeltaSol® AX©

    RES

    OL

    0625

    5 de

    ltaso

    l_ax

    .mon

    en.in

    dd

    3 |

    Electrostatical discharges can lead to damages of electronic components!

    Dangerousvoltageoncontact!

    DeltaSol® AXThanks to its tough and deliberately simple design concept this low priceddifferentialcontrollercanbewidelyusedinsolar,heatingandairconditioningsystems.Thelargecontrolrangeandadjustabletemperaturedifferencesensurethatthisunitcanbeusedinalmostallapplicationswhereswitchingprocessesarecontrolledbytemperaturedifference.Theouter cover is availablewith anoptional seal toprotect the electronicsagainst dripping water.

    The controller checks a temperature diffference ∆T measured by two tem-perature sensors by comparing this difference with a preadjusted switch-ondifference(adjustablewithintherangeof2...16K).Thecontrolofthesystemiseffectedbyastandardrelay(=changeovercontact),towhichseveralmotorsorelectricalvalvescanbeconnected.Thecontrollerswitches-ON,iftheadjustedtemperaturedifferenceisexceeded;ifthisdifferenceisunderrunby1,6K,thecontroller switches-OFF.

    130

    45

    Technical dataHousing: plug-in plastic PC-ABS

    Protection type: IP20/DIN40050

    Ambient temp.: 0 ... 40 °CSize: Ø130mm,45mmheight

    Mounting: wall mounting

    Display: 1 function control lamp

    Inputs: 2sensorinputsPT1000

    Outputs: 1standardrelay(changeovercontact)

    Switch-on difference: ∆T2...16KadjustableSwitch-off difference: 1,6Kbelowswitch-ondifference

    Control range: -20 ... +150 °C

    Power consumption: max. 4 A

    Powersupply:220...240V~

    Order indications

    RESOL DeltaSol AX 115 211 70

    RESOL DeltaSol A X- full kit - 115 211 80incl. 2 temperature sensors Pt1000 (1xFKP6,1xFRP6)

    Accessory Overvoltage protection

    ItishighlyrecommendedtoconnecttheRESOLovervoltageprotectionSP1toallcollectorsensorsinordertoavoidovervoltages(e.g.bylightning).

    RESOL SP1 180 110 10

  • DeltaSol® AX

    © R

    ESO

    L 06

    255

    delta

    sol_

    ax.m

    onen

    .indd

    | 4

    Theunitshouldbelocatedinternally.Itisnotsuitableforinstallationinhazardouslocationsandshouldnotbesitedneartoanyelectromagneticfield.Pleaseensuresensorcablesandacpowersupplyareseparated.

    1. Choosea location,drill twoholesofØ6mmsidebysidewithadistanceof113mmandfitintheencloseddowels.

    2. Fixthecontrollerbymeansoftheenclosedscrews(4x40 mm)(pos. 1).

    3.Theelectricalconnectionmustbeeffectednow.Powersupplyofthecontroller(210...250V)mustbeeffectedbyexternalpowerswitch.

    Connection of the sensors at the clamps:

    1/2 = sensor1(e.g.collectorsensor)

    3/4 = sensor2(e.g.storesensor)

    Connection of the consumer to the clamps: 7 = normallyopencontactrelay(RO) 8 = breakcontactrelay(RC) 9 = neutralcontactrelay(N)

    ground clamp (collective terminal strip)

    ac power supply to the clamps:

    10 = neutralconductorN

    11 = conductorL

    ground clamp (collective terminal strip)

    Theguidesoftherequiredinsertionchannelsmustbebrokenawayatthebottomsideofthecover.

    Thecablesaretobefixedtothehousingbyenclosedstrainrelief supports and screws (pos.2).

    If necessary, activate anti-freeze function by jumper. Ifprotection against dripping water is required insert the siliconesealingringintothegrooveonthebaseplatetakingcare not to stretch it.

    Putonthecoverandscrewit(pos.3).Ifnecessary,adjusttemperature difference ∆T.Putonhousingcoverandscrewit(pos.4).

    1. InstallationWarning!Switch-off power supply before opening the housing.

    1

    4

    3

    2

    housingcovercover

    base

    sensor 1

    sensor 2relay(consumer)

    acpowersupply

    ground clamp (collectiveterminalstrip)

    fuseT4A

    1.2 Electrical connection

    Insertsealingbandwithoutstrainintothenut

  • DeltaSol® AX©

    RES

    OL

    0625

    5 de

    ltaso

    l_ax

    .mon

    en.in

    dd

    5 |

    2.1 Micro-Switch and Potentiometer

    2. Functions and Settings

    Themicro-switch(A)activates(ON)deactivates(OFF)

    following functions:

    •Manualoperation(micro-switch1)•Maximumtemperaturelimitation(micro-switch2)•Anti-freezeprotection(micro-switch3)•Minimumtemperaturelimitation(micro-switch4)

    Potentiometer(B)adjuststhetemperatureforthemaxi-mum or minimum temperature limitation in °C.

    Potentiometer(C)adjuststheswitch-ontemperatureinK

    2.3 Manual operation modeON

    OFF1 2 3 4

    1

    ON

    OFF1 2 3 4

    ON

    OFF1 2 3 4

    B

    C

    2.2 Switch-on temperature difference

    ON

    OFF1 2 3 4

    A

    ThecontrollercheckstheexistingtemperaturedifferencebetweentemperaturesensorS1andtemperaturesensorS2withtheadjustedtemperaturedifference∆Tatthepotentiometer(C).Thecontrollerswitchesovertherelayassoonasthetemperaturereachestheadjustednominalvalue,theoperatingcontrollampflashesgreen.Ifthesetvalueisunderrunbyadifferenceof1,6K(hysteresis,cannotbechanged)thecontrollerswitchestherelayback.

    Thefactorysettingfortheswitch-ontemperaturedifferenceispreadjustedto6K.Adjustabletemperaturedifferencewithinarangeof2...16K.

    ON

    OFF1 2 3 4

    C

    A

    Duringcomissioningandmaintenancetherelaycanbeswitched-onpermanentlybymanualoperation.

    Themanualoperationmodeisactivatedanddeactivatedbythemicro-switch.Whenthemanualoperationmodeisactivated,theoperatingcontrollampflashesgreen.

    Thefactorysettingforthemanualoperationmodeisdeac-tivated(micro-switchinOFF-position),thecontrollerisinautomatic operation.

  • DeltaSol® AX

    © R

    ESO

    L 06

    255

    delta

    sol_

    ax.m

    onen

    .indd

    | 6

    Micro-switch3activatesananti-freezeprotectionfunction.Theanti-freezeprotection functionreacts to the tempe-rature of sensor S1(e.g. a collector sensor). As soon as thissensormeasuresatemperaturebelow+4°C,warmerwaterispumpedfromthestoretothecollectortopreventdamages to the collector; in the course of this the operating control lampflashes green.As soon as a temperatureof+5°Cisreached,thepumpswitches-offagain.

    Please note:Asthereisonlyalimitedheatquantityofthestoreavailableforthisfunction,theanti-freezefunctionshouldonlybeusedinregionswithfewdaysoftemperaturesaround freezing point.

    Thefactorysettingfortheanti-freezefunctionisdeactivated.(micro-switch in OFF-position).

    2.5 Anti-freeze protection

    3

    ON

    OFF1 2 3 4

    2.6 Minimum temperature limitation

    4

    Micro-switch4activatesthetemperaturelimitationasami-nimumtemperaturelimitation.ThetemperatureisadjustedasalimitingvalueforthesensormountedontheterminalsS1atthepotentiometer„temperaturelimitation“.Therelaywon’tswitchuntiltheadjustedtemperatureisreached.Thisfunctionshouldpreferablybeusedincombinationwithasolidfuelboiler inordertoavoidfluegascondensationwithintheboiler.Bymaintainingaminimumtemperaturelimitationintheheatgeneratorafluegascondensationonthe boilerwalls isavoided.Iftheminimumtemperatureisunderrun,theoperatingcontrollampflashesred.

    Thefactorysettingfortheminimumtemperaturelimitationisdeactivated(micro-switchinOFF-position).Whenactiva-ted,atemperaturelimitationof60°Cispreadjusted.

    ON

    OFF1 2 3 4

    ON

    OFF1 2 3 4

    A

    A B

    2.4 Maximum temperature limitation

    2

    Micro-switch2activatesthetemperaturelimitationasamaximumtemperaturelimitation.ThetemperatureforthetemperaturesensormountedonclampS2isadjustedasalimitingvalueatthepotentiometer(B).Iftheadjustedma-ximumtemperatureisexceeded,therelayisswitchedoverandsopreventse.g.afurtherstoragecharge(protectionagainstoverheating).Ifthemaximumstoretemperatureisexceeded,theoperatingcontrollampflashesred.

    Thefactorysettingforthemaximumtemperaturelimitationisactivated(micro-switchinON-position),Thetemperaturelimitationispreadjustedto60°C.Adjustabletemperaturedifferencewithinarangeof20...90°C.

    ON

    OFF1 2 3 4

    ON

    OFF1 2 3 4

    BA

    2.7 Blinking codes

    TheLEDshowstheactualoperatingstatusofthecont-roller.

    Readyforuse red

    Relayactive green

    Manualmodeactive green(blinking)Maximum temperature exceeded red(blinking)

    Anti-freezeprotectionactive green(blinking)Minimum temperature under-run red(blinking)

  • DeltaSol® AX©

    RES

    OL

    0625

    5 de

    ltaso

    l_ax

    .mon

    en.in

    dd

    7 |

    4. Application examples

    Standard solar system with 1 store

    Ifthecurrenttemperaturedifference∆Tbetweencollectorsensor S1 and store sensor S2 exceeds the temperature differenceadjustedatthecontroller,thesolarpumpisswitched-on. Heat is transported from the collector to the store; in the course of this the temperature difference is reduced.Iftheadjustedtemperaturedifferenceisunderrunbyadifferenceof1,6K(hysteresis,cannotbechanged),thepump is switched-off again.

    Ifthecontrollerdoesnotworkperfectly,pleasecheckthefollowing items:

    Ifthecontrollerdoesnotswitchonwhenthereisapowersupply available please check the fuses.The controller isprotectedbyafinefuseT4A,whichcanbereplacedafterhavingremovedthehousingandthecover.Asparefuseisenclosedonthebacksideofthecover.

    Pleasecheckthesensors.Sensorswhicharenotconnected,musthavefollowingresistancevaluesdependingonthegiventemperature.

    3. Tips for fault diagnostics

    ResistancevaluesofthePt1000-sensors

    1S1 S2

    2 3 4 7RO RC N N L

    8 9 10 11

    S1

    RO

    S2

    ON

    OFF1 2 3 4

    C

    ON

    OFF1 2 3 4

    A

    ON

    OFF1 2 3 4

    B

    S1=collectorsensor

    S2=storesensor

    RO=solarpump

    bracketforsparefuse(interiorpartofcover)

    Usegroundclampcollectiveterminalstrip!

    °C -10 -5 0 5 10 15 20 25 30

    W 961 980 1000 1019 1039 1058 1078 1097 1117

    °C 35 40 45 50 55 60 65 70 75

    W 1136 1155 1175 1194 1213 1232 1252 1271 1290

    °C 80 85 90 95 100 105 110 115

    W 1309 1328 1347 1366 1385 1404 1423 1442

  • DeltaSol® AX

    © R

    ESO

    L 06

    255

    delta

    sol_

    ax.m

    onen

    .indd

    | 8

    1S1 S2

    2 3 4 7RO RC N N L

    8 9 10 11

    S2

    Heat exchange (betweentwostores)

    S1

    R0

    ON

    OFF1 2 3 4

    C

    ON

    OFF1 2 3 4

    A

    Ifthetemperaturedifference∆Tbetweenstore(1)-sensorS1andstore(2)-sensorS2exceedsthetemperatureadjus-tedatthecontroller,thecirculationpumpisswitched-on.Heat is transported from the store (1) into store (2); in the course of this the temperature difference is reduced.

    Iftheadjustedtemperaturedifferenceisunderrunbyadif-ferenceof1,6K(hysteresis,cannotbechanged),thepumpis switched-off again.

    S1 = store(1)sensorS2 = store(2)sensorRO= circulationpump

    Ifthetemperaturedifference∆TbetweenstoresensorS1and heating circuit return sensor S2 exceeds the tempera-turedifferenceadjustedatthecontroller,the3-way-valveisswitched-over.Thereturntemperatureoftheheatingcircuitisraisedbytheheatofthestoresothatlessconventionalenergyisnecessarytoreachtherequiredflowtemperature;in the course of this the temperature difference is reduced.

    Iftheadjustedtemperaturedifferenceisunderrunbyadif-ferenceof1,6K(hysteresis,cannotbechanged),thevalveisswitched to initial position.

    S1 = storesensorS2 =heatingcircuitreversesensorRO=3-way-valve

    Heating circuit - raising the return temperature1

    S1 S22 3 4 7

    RO RC N N L8 9 10 11

    S1

    C

    A

    RO

    S2

    ON

    OFF1 2 3 4

    ON

    OFF1 2 3 4

    Usegroundclampcollectiveterminalstrip!

    Usegroundclampcollectiveterminalstrip!

  • DeltaSol® AX©

    RES

    OL

    0625

    5 de

    ltaso

    l_ax

    .mon

    en.in

    dd

    9 |

    Thecontrollercomparesthetemperatureatthesensorofthesolidfuelboilerorboilerinsertedinstove(S1)withthetemperatureatthesensoratstore(S2).Ifthedetec-ted temperature difference is higher than or equals the preadjustedvalue∆T,thepump(RO)isswitched-onwhensimultaneouslythegivenminimumtemperatureisreachedorexceeded.Thetemperaturedifferenceisreduced.

    Store charge

    1S1 S2

    2 3 4 7RO RC N N L

    8 9 10 11

    S1

    R0

    S2

    ON

    OFF1 2 3 4

    C

    ON

    OFF1 2 3 4

    A

    ON

    OFF1 2 3 4

    B

    Ifthedifference1,6K(hysterisis,candifferenceisreduced,cannotbechanged)underrunstheadjustedtemperaturedifference,thepumpisswitched-offagain.

    S1=boilersensor

    S2=storesensor

    RO=circulationpump

    t

    Usegroundclampcollectiveterminalstrip!

  • DeltaSol® AX

    © R

    ESO

    L 06

    255

    delta

    sol_

    ax.m

    onen

    .indd

    | 10

    Pumpstartsforashortmoment,switches-off,switches-onagain,etc.(„controllerhunting“)

    Is the temperaturedif-ference at the controller too small?

    no yes

    Wrongpositionofthecollector sensor?

    yes

    Change ∆Ton and ∆Toffaccordingly.

    Mount the collector sen-

    soratsolarflow

    warmest collector out-

    put);

    Pumpstartsupverylateandsoonstopsworkingsoon. Thetemperaturedifferencebetweenstoreandcollectorincreasesenormouslyduringoperation;thecollectorcir-cuit cannot dissipate the heat.

    Collector circuit pump defect ?

    no yes

    Heat exchanger calci-fied??

    yes

    Conrtol/replacement

    Decalificatiomno

    Heatexchangerblocked?

    yesno Cleaning

    Heat exchanger too small?

    yes Newcalculationofthedimension.

    Change ∆Ton and ∆Toffaccordingly.

    Switch-on-temperature difference ∆Ton too large

    no yes

    Collectorsensorunfavour-ableplaced (e.g. contactsensor instead of immersion sleevesensor?

    o.k.no

    Pumpisoverheated,butnoheattransferfromcollectortothestore,feedflowandreturnflowareequallywarm,perhapsalsobubbleinthelines.

    Ventsystem;increasesys-tem pressure to at least staticprimarypressureplus0,5bar; ifnecessa-rycontinuetoincrease,switch the pump for a short time off and on.

    Airinthesystem?

    no yes

    Isthecollectorcircuitblockedatthedirttrap?

    yes

    Clean the dirt trap

    Ifnecessaryactivatetubecollector function.

    yes

    o.k.

    5. Annex: Fault finding

  • DeltaSol® AX©

    RES

    OL

    0625

    5 de

    ltaso

    l_ax

    .mon

    en.in

    dd

    11 |

    Stores are cooled during the night.

    Doescollectorcircuitpump run during the night?

    no yesCheck the controller functions

    Collector temperature is higher at night than am-bienttemperature?

    no yesCheck operation of non returnvalves.

    Istroreinsulationsuffi-cient?

    yes noIntensifytheinsulation.

    Isstoreinsulationcloseenough to the store?

    yes no

    Replaceor intesify theinsulation.

    Are the store connceti-ons insulated?

    yes noInsulateconnections.

    Warmwateroutflowupwards?

    no yes

    Change connection and let the water flow side-wards or through a siphon (bowdownwards); lessstore losses now?

    Thesolarcircuitpumpdoesnotworkalthoughthecoll-ectorisobviouslywarmerthanthestore.

    DoesthecontrolLEDflash?

    yes no

    Doesthepumpstartupin manual operation?

    yes

    Thereisnocurrent;checkfuses/replacethemandcheckpowersupply.

    Theadjustedtemperaturedifference for starting the pump is too high; choose avaluewhichmakesmoresense.

    no

    Isthecurrentofthepumpreleasedbythecontroller?

    Free the pump using a screwdriver;inoperationnow?

    Is thepumpdefective -replace it.

    Are the fuses of the controller o.k.?

    Controllerseemstobedefective-replaceit.

    no

    no

    no yes

    Replace the fuses.

    no yes

    o.k.

    Controlthereturnflowpreventerinwarmwatercirculation- o.k.

    no

    Cleaning or replacement.

    yes Isthepumpstuck?

    yes

  • DeltaSol® AX

    © R

    ESO

    L 06

    255

    delta

    sol_

    ax.m

    onen

    .indd

    | 12