D D D D D eltaS eltaS eltaS eltaS eltaS ol ol ol ol ol ® ® ® ® ® B www.resol.de RESOL DeltaS eltaS eltaS eltaS eltaSol ol ol ol ol ® ® ® ® ® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the best performance from this unit.

Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDD De

lta

Se

lta

Se

lta

Se

lta

Se

lta

So

lo

lo

lo

lo

®

®

®

® B

www.resol.de

RESOL DDDDDeltaSeltaSeltaSeltaSeltaSololololol® ® ® ® ® B

Mounting

Connection

Operation

Examples

Thanks for buying a RESOL.Read this manual carefully to get the best performance from this unit.

Page 2: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 2/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

Contents

Security devices ................................................................ 2

Technichal data and function survey .............................. 3

1. Installation ............................................................. 5

1.1 Mounting ............................................................... 5

1.2 Electrical wiring .................................................... 5

2. Sensor types ......................................................... 6

3. Operation and function ........................................ 7

3.1 Adjustment switch ................................................ 7

3.2 Control parameter and indication channels ....... 7

3.2.1 Indication channel TC ........................................... 8

3.2.2 Indication channel TS ........................................... 8

3.2.3 Indication channel TT / T3 ................................... 8

3.2.4 Indication channel PC .......................................... 8

3.2.5 Indication channel HO ......................................... 8

3.2.6 ∆∆∆∆∆T-regulation ......................................................... 8

3.2.7 Maximum store temperture ............................... 8

3.2.8 Limit collector tempreture .................................. 9

3.2.9 Maximum collector temperature ....................... 9

3.2.10 Minimum collector tempreture .......................... 9

3.2.11 Recooling function ................................................ 9

3.2.12 Collector colling function ................................... 10

3.2.13 Minimum pump speed ........................................ 10

3.2.14 Operation mode ................................................. 10

3.2.15 Thermostat function .......................................... 10

3.2.16 LED blinking codes ............................................. 11

4. Comissioning ....................................................... 11

5. Tips for fault localization .................................... 11

6. Examples ............................................................. 12

6.1 Standard solarsystem ......................................... 12

6.2 Solarsystem with after-heating .......................... 12

6.3 Additional solar heating(heating support) ....... 13

6.4 After-heating of store with minimum

temperature limitation ...................................... 13

6.5 Atore after-heating via buffer store .................. 14

6.6 Swimming-pool solar system ............................. 14

6.7 Thermostat system (heating / cooling) ............ 15

This mounting- and operation manual including all parts iscopyrighted. Another use outside the copyright requires theapproval of RESOL - Elektronische Regelungen GmbH. Thisespecially applies for copies, translations, micro films andthe storage into electronic systems.

Editor: RESOL - Elektronische Regelungen GmbH

Important notice:We took a lot of care over the texts and drawings of thismanual and to the best of our knowledge and consent. Asfaults can never be excluded, please note:Your own calculations and plans under consideration of thecurrent norms and DIN-directions should only be basis foryour projects. We don´t offer a guarantee for thecompleteness of the drawings and texts of this manual -they only represent some examples. They can only be usedon own risk. No liability is assumed for incorrect, incompleteor false information and the resulting damages.

Errors and technical changes excepted

Imprint:

TRD 802 Steamboiler of group III,TRD 402 Equipment of steamboiler systems with hot watergenerators of group IVDIN 1988, Teil 1 – 8 Technichal rules for drinking water installationDIN 4708, Teil 3 Central warm water heating systemsDIN 4751, Teil 1 + 2 Water heating systemsDIN 4753 Water heater and systems and for drinking waterDIN 4757, Teil 1 – 4 Solar heating and solar thermal systemsDIN 18338 Roofing and roof sealing worksDIN 18339 Plumbers worksDIN 18451 Scaffolding worksVDE 0100 Set up of electrical operating suppliesVDE 0185 General rules for setting up overvoltage protection

systemsVDE 0190 Main potential equalization of electrical systemsDIN 18381 Gas-, water- and sewage installation systemsDIN 18382 Electrical cable- and line systems in housingsHeizAnlV Heating system regulation

Safety regulations:

Please read the followinginformation carefully beforeinstalling and operating thecontroller. In this way damageto the solar system by wronginstallation will be avoided.Please observe that themounting is adapted to thecharacteristics of the building,that the local regulations arerespected and is conform tothe technical rules.

Page 3: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 3/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

• housing in outstandingdesign and compactdimensions, easy toinstall

• multifunctional com-bined display

• user-friendly opera-tion by simple hand-ling

• intuitive menu mode

• function control

• optional speed control,solar operation hourscounter and thermos-tat function

RESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B – the next generation of controllers

Technical dataHousing: plastic, PC-ABS and PMMAProtection type: IP 20/DIN 40050Environmental temperature: 0 ... 40°CSize: 172 x 110 x 46 mmInstallation: wall mounting, mounting intopatch panels is possibleDisplay: LCD, multi-functional combineddisplay with 8 pictograms, two 2-digittext fields and two 4-digit 7-segment dis-plays as well as one 2-coloured lumines-cent diodeOperation: by three pushbuttons in thefront of the housing

The controller RESOL DeltaSol® Bis used for application in standard so-lar thermal systems as well as in hea-ting and air conditioning systems andpersuades by its clear operation con-cept.

A newly developed, multi-functionaldisplay enables the user to simutane-ously request two temperatures (e.g.collector and store temperature). Simp-le icons give information about functionand opertion mode of the device or

system which can be understood easi-ly.

The controller is equipped with 3 sen-sor inputs for Pt1000-sensors, storetemperature limitation and a manualswitch (menu). The central operationelement is the 3-key-field below thedisplay. The newly developed combinedLC-display enables an intuitive and re-liable controller configuration as wellas a comprehensive visualisation of thesystem status. Collector cooling and

recooling and recooling function as wellas a security switch-off, but also a ther-mostat function can be realised easily.A speed control and a solar operationhours counter are also integrated de-pending on the controller variant (lookat the overview „controller versions“)

The controller DeltaSol® B is alsoavailable as an individual OEM-version,so that further system adaptions arepossible.

Functions: standard solar controller withadjustable values: minimum-maximum tem-perature limitation, switch-on and switch-off-temperature difference. Frost protec-tion / cooling function, security switch-off,function control according to BAW-direc-tions, speed control and solar operationhours counter (depending on program,look at overview „controller versions“)Inputs: 3 temperature sensors Pt1000Output:depending on version, look at overview „con-troller versions“Breaking capacity: max. 4A

Power supply:210 ... 250V (AC) 50 ... 60 HzPower consumption: approx. 2 VAdegree of pollution: 2

rating surge voltage: 2,5 kV

temp. for ball pressure check: 75°C

mode of functioning:type 1.b (versions 51.02, 53.02)type 1.y (versions 52.02, 54.02)

breaking capacity per relay:semi-conductor relay: 1,6 (1) A 250 V~electromechanical relay: 4 (2) A 250 V~

Electrostatical discharge cancause damage of electroniccomponents.

Attention! Parts are highvoltage energized.

Controller version PG

Semi-conductor

relay

Standard relay

Speed control

Operation hours counter

Thermostat function

51.02 0 1 no yes no 52.02 1 0 yes no no 53.02 0 2 no yes yes 54.02 1 1 yes no yes

Controller versions:

Page 4: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 4/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

Examples DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B

Standard solar systems

Swimming pool-solarsystems

Store after-heatingby solid fuel boilers with

minimum temperaturelimitation

Store after-heatingvia buffer store

Electronic thermostat(heating / cooling)

Additional solar heating(heating support)

AccessoryOvervoltage protection

It is highly recommended to connect this RESOL overvoltage protection SP1 to all collectorsensors in order to avoid overvoltages (e.g. by lightning).

RESOL SP1 Art.-No.: 180 110 10

Order indication:

• Version 51.02: 1 Standard relay, operation hours counterRESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 1 115 313 70RESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 1 - full kitincl. 3 Temperature sensors Pt1000 (1 x FKP6, 2 x FRP6) 115 313 80

• Version 52.02: 1 Semiconductor relay, Speed controlRESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 2 115 313 20RESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 2 - full kitincl. 3 Temperature sensors Pt1000 (1 x FKP6, 2 x FRP6) 115 313 40

• Version 53.02: 2 Standard relay, Thermostat function,Operation hours counterRESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 3 115 313 50RESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 3 - full kitincl. 3 Temperature sensors Pt1000 (1 x FKP6, 2 x FRP6) 115 313 30

• Version 54.02: 1 Semiconductor relay,1 Standard relay, Speed control, Thermostat function

RESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B / 4 115 320 10RESOL DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol®®®®® B/ 4 - full kitincl. 3 Temperature sensors Pt1000 (1 x FKP6, 2 x FRP6) 115 320 20

Please find detailedconnection schemes forthe shown systems inchapter 6.

Solar systems withafter-heating

(53.02/54.02)

Page 5: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 5/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

1.1Mounting

The unit must only be located internally. It is not suitable forinstallation in hazardous locations and should not be sitednear to any electromagnetic field. The controller mustadditionally be equipped with an all-polar gap of at least 3mm or with a gap according to the valid installatonregulations, e.g. LS-switches or fuses. Please pay attentionto a seperate laying of the cable lines and installation of acpower supply.

1. Installation

housing

key field

base

clamps

cover

cable conduits with strain relief

operation control lamp

combined LCD

Warning!Switch-off power supply beforeopening the housing.

1. Unscrew the cross-recessed screw of the cover andremove it from the housing.

2. Mark the upper fastening point on the underground andpremount the enclosed dowel and screw.

3. Hang up the housing at the upper fastening point and markthe lower fastening point on the underground (hole pitch130 mm), afterwards put the lower dowel.

4. Fasten the housing at the underground.

1.2 Electrical wiringThe power supply to the controller must only be made byan external power supply switch (last step of installation!)and the line voltage must be 210 ... 250 Volt (50...60 Hz). Fle-xible lines are to be fixed at the housing by enclosed strainrelief supports and screws.Depending on the version the controller is equipped with1 relay (PG 51.02 and PG52.02) or 2 relays (PG 53.02 andPG54.02, cp. overview „Controller versions“ on p. 3) towhich the consumers e.g. pumps, valves etc. can beconnected:• Relay 1 (PG 52.05 and PG 54.02)18 = conductor R117 = neutral conductor N13 = ground clamp • Relay 2 (PG 53.02 and PG 54.02)16 = conductor R215 = neutral conductor N14 = ground clamp The temperature sensors (S1 up to S3) will be connectedto the following terminals independently of the polarity:1 / 2 = sensor for heat source (e.g. collector sensor)3 / 4 = sensor for heat sink (e.g. store sensor)5 / 6 = additional sensor (PG 51.02 and PG 52.02)

or thermostat sensor (PG 53.02 and PG 54.02)

The power supply is effected to the clamps:19 = neutral conductor N20 = conductor L12 = ground clamp

net clamps

fuse

sensor clamps consumer clamps

net clampssensor clamps

consumer clamps

fuse

Page 6: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 6/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

Precision-platin sensors type PT1000 (FKP and FRP) areused for DeltaSolDeltaSolDeltaSolDeltaSolDeltaSol® B.

The arrangement of the sensors is of great importance tothe total efficiency of the regulator. The collectortemperature should be measured in the upper part of thecollector. In stores with integral heat exchanger, the sensormust be directly mounted in the upper part of the heatexchanger. When using external heat exchangers, the sensormust be fixed at the bottom of the store. For individualoperation systems, our product range contains 3 differenttypes of sensors (sensors for installation in existingimmersion sleeves, flatscrew sensors or cylindrical clip-onsensors). The sensor types FK and FR have the sameelectrical features and are available in the same models, Theyonly differ in the connecting cable:

2. Sensor types

Immersion sensors: in different lengths (immersiondepth) availableFK...60: 60 mm immersion depth, immersion sleeves ofchromium-plated brassFK...150: 150 mm immersion depth, immersion sleeve ofchromium-plated copperImportant: The sensors must be completely pushed intothe sleeve and the nut must be slightly tightenend.

Cylindrical clip-on sensors: for any pipe diameter; cpl.with fastening collar; FK...21 or FR...21Ensure good thermal contact of the sensor with the pipework by cleaning the contact area and by applying heatconduction paste between sensor and pipe. In order toprotect the sensor cable against outside temperatureinfluences, it is recommended to insulate the pipe..

Flatscrew sensors: for installation on flat surfacesFK...9 or FR...9Ensure good thermal contact. Use conduction paste andinsulate the sensors against outside temperature influences.Indication:In order to avoid overvoltage damage at the collector (e.g.by lightening), it is highly recommendend to use theovervoltage protection RESOL SP1.

FK... : collector sensorFR... : reference sensor (store sensor)

FK: 1,5 m weather- and temperature resistant silicone cablefor temperatures between -50 °C ... +180 °C, mostly usedfor collectors.

FR: 2,5 m PVC cable for tempertures between-5 °C ... +80 °C, mostly used for stores.

Make sure that all electrical works are carried out accordingto the relevant local and IEE-regulations. The sensor cablescarry low voltages and they must not run together in a cableconduit with cables carrying higher voltages than 50 Volts.When using longer cables or cable conduits, please usescreened cables. The sensor cables can be lengthened up to100 m, but the cross section must be 1,5 mm² (or 0,75 mm²up to a cable length of 50m); screened cables should be usedpreferably. The sensors must not be in direct contact withwater, please always use immersion sleeves.

Page 7: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 7/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

123

123

3. Operation and function

3.1 Adjustment keysThe controller is only operated by the 3 pushbuttons belowthe display. The forward-key (1) is used for scrolling forwardthrough the indication menu or to increase the adjustmentvalues. The backwards-key (2) is accordingly used for thereverse function.

The adjustment channels follow the pure indication channelsin the display. In order to come to these channels, press theforward key to channel HO (PG 51.02 and PG53.02) or tochannel PC (PG 52.02 und PG54.02) for 2 sec. If anadjustment value is shown on the display, SEt is indicated.In this case you can press the key „Set“ (3) in order tochange into input mode.

! Select a channel by keys 1 and 2! Shortly press key 3, so that „SEt“ flashes! Adjust the value by keys 1 and 2! Shortly press key 3, so that „SEt“ permanently

appears, the adjusted value is now saved

backwards forwards

set(selection / adjustment mode)

3.2 Controller parameter / indication channnels

• TC=TemperatureCollectorcollector temperature

• TS=TemperatureStoragestore temperature

• TT/T3=Termperature (Thermostat)Thermostat temperature (only PG 53.02 and PG 54.02)

• PC=PumpSpeed Currentcurrent relative pump rotational speed(only PG 52.02 and PG 54.02)

• HO=Hours of Operationsolar operating hours(only PG 51.02 and 53.02)

• DO=Temperature Difference Onstarting temperature difference

• DF=Temperature Difference OfFswitch off temperature difference

• SX=StorageTemperatur(MaXimum)maximum store temperature

• CL=CollectorTemperature(Limited)collector limiting temperature

• CX=CollectorTemperature(MaXimum)maximum collector temperature

• CN=CollectorTemperature(MiNimum)minimum collector temperature

• TO=ThermostatTemperature (On)thermostat starting temperature(only PG 53.02 and PG 54.02))

• TF=ThermostatTemperature(OfF)thermostat switch off temperature(only PG 53.02)

• FN=FuNctionFunction0 : Maximum store temperature deactivated1 : Maximum store temperature activated2 : Maximum store temperature deactivated, recooling

function activated3 : Maximum store temperature activated, recooling

function activated• PN=PumpSpeed MiNimal

minimum relative pump rotational speed(only PG 52.02 and PG54.02)

• MM=ModeManual for PG 53.02 and PG 54.02manual operation mode0 : relays 1 and 2 are deactivated1 : relay 1 is activated, relay 2 is deactivated2 : relay 1 is deactivated, relay 2 is activated3 : relays 1 and 2 are activated4 : automatic operation

• MM=ModeManual for PG 51.02 and PG 52.02manual operation mode0 : relay 1 is deactivated1 : relay 1 is activated2 : automatic operation

• PG=ProGramprogram number

• VN=VersionNumberversion number

Please note: The controller is equipped with a security switch-off of the store, which prevents a further loading of thestore at 90 °C store temperature.

Page 8: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 8/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

3.2.6 ∆∆∆∆∆T-controller (DODODODODO, DFDFDFDFDF)

The controller controls the temperatures measured by thetwo sensors S1 and S2 and compares the resultingtemperature difference with the preadjusted switch-on-temperature difference ∆T

ON (DO). The controller switches

ON, when the measured temperature difference ∆T is higherthan or identical to the preadjusted set value in channel DO.In the display is shown and the operating control lampflashes green. When the adjusted switch-off-temperature-difference ∆TOFF (DF) is underrun, the controller switches-OFF. By RESOL, the switch-on temperature difference is setto 6 K and the switch-off temperature difference is set to4 K.

Please note: Switch-on temperature difference DO mustbe at least 1 K higher than the switch-off temperaturedifference DF.

3.2.7 Maximum store temperature (SXSXSXSXSX)If the adjusted maximum temperature is exceeded, a furt-her loading of the store is stopped so that a damagingoverheating can be avoided. The maximum store temperatureis activated by factory setting (FN =3). If the maximum storetemperature is exceeded in the display is shown and (flashing), the operating control lamp flashes red. In order torealize a pure maximum temperature limitation and todeactivate the recooling- and/or collector cooling function,FN = 1 must be adjusted.

3.2.1 Indication channel TCThe indication channel TC indicates the current sensortemperature of the heat source (e.g. collector sensor) in °C.

3.2.2 Indication channel TSThe indication channel TS indicates the current sensortemperature of the heat sink (e.g. store sensor) in °C.

3.2.3 Indication channel TT / T3The indication channel TT/T3 indicates the current sensortemperature for the thermostat function (only PG 53.02 /54.02) or of the additional sensor (PG 51.02 / 52.02, withoutinfluence oon regulation) in °C.

3.2.5 Indication channel HOThe indication channel HO (only PG 51.02 / 53.02) indicatesthe solar operating hours of the solar pump resp. theoperating hours of the consumer connected to the relayoutput R1. The summed-up operating time is saved in an 6-hour-cycle so that the maximum deviation in case of a powerfailure is 6 hours at the most. This display value can not beresetted.

3.2.4 Indication channel PCThe indication channel PC (only PG 52.02 / 54.02) indicatesthe current relative rotational speed of the solar pump resp.the rotational speed of the consumer connected to the relayoutput R1.

DO: turn-on temperaturedifferenceadjustable values 2 ... 10 Kfactory setting 6.0

DF:Turn-off temperaturedifferenceadjustable values 1 ... 9 Kfactory setting 4.0 K

SX: maximum store temperatureadjustable values 2 ... 85 °Cfactory setting 60 °C

Page 9: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 9/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

3.2.8 Limit collector temperature (CLCLCLCLCL)Extremely high collector temperatures are normallyintercepted by a properly dimensioned membrane-expansionball. If the preadjusted collector limit temperature(CL) is exceeded, the solar pump (R1) is switched-off in orderto avoid a damaging overheating of the solar components(collector safety shutdown). The limit temperature is set to140 °C by RESOL but it can be changed within theadjustment range of 110 ... 200 °C. In the display is shown

and if the maximum collector temperature isexceeded, the operating control lamp flashes red.

3.2.9 Maximum collector temperature (CXCXCXCXCX)If the collector temperature exceeds the adjusted maximumcollector temperature (CX) in standstill of the solar circuit(maximum store temperature is reached), the solar pump(R1) switches-on and cools the collectors by heat transfervia lines and the store (collector cooling function). The storetemperature might increase, but only up to 90 °C (safetyshutdown of the store). This function guarantees a longeroperating time for very hot summer days and ensures a ther-mal relief for the collectors and the heating medium. Themaximum collector temperature is set to 120 °C by RESOL,but it can be changed within the adjustment range of100 °C ... 190 °C. In the display is shown , and ifthe maximum collector temperature is exceeded, theoperating control lamp flashes green.

3.2.11Recooling function

Recooling (FN 2FN 2FN 2FN 2FN 2):If the adjusted maximum store temperature (S XS XS XS XS X) isexceeded, the solar pump remains activated in order to avoidan overheating of the collector. The store temperature mayincease - but only up to 90 °C (store safety shutdown).The solar systems remains running in the evening until thestore is cooled down to the adjusted maximum storetemperature (S XS XS XS XS X) by the collector or lines.

The minimum collector temperature is a minimum switchingtemperature, which must be exceeded so that the solarpump (R1) is switched-on. The minimum temperature shallavoid a steady starting-up of the solar pump (or solid fuelboiler charging pumps) for low collector temperatures.Theminimum temperature is set to 10 °C by RESOL (=deactivated). In the display is shown and if theminimum collector temperature is exceeded, the operatingcontrol lamp flashes green. This function analogly is alsousable as minimum temperature limitation for solid fuelboilers, recommended adjustment value: 60 °C.

Please note:The minimum collector temperature is used for adjustmentof the frost protection function between -10,0 ... 9,9 °C forminimum temperature function between 10,1 ... 90 °C.

3.2.10 Minimum collector temperature (CNCNCNCNCN)

CL: collector limitingtemperatureadjustable 110 ... 200 °C,factory setting 140 °C

CX:maximum collectortemperatureadjustable values 100... 190 °Cfactory setting 120 °C

CN : minimum colletortemperatureadjustable values -10 ... 90 °Cfactory setting 10 °C

Page 10: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 10/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

Display: PG 53.02 / PG 54.02

The controller is equipped with a 2nd relay and a 3rd tem-perature sensor input (S3, e.g. in the upper store part) forthermostat function. The thermostat function worksindependently from the solar operation and can e.g. be usedfor use of surplus energy or after-heating. Adjustement byRESOL to = 40 °C, tf = 40 °C

• to = tfthe thermostat function is deactivated, in this caserelay output R2 is activated if the maximum storetemperature is exceeded

• To < Tfthe thermostat function is used for after-heating

• To > Tfthe thermostat function is used as use of surplusenergy

If the 2nd relay output is activated, in the display isshown .

3.2.15 Thermostat function (ttttto, TFo, TFo, TFo, TFo, TF)

after-heating use of surplus energy

The regulator’s operating mode can be adjusted manuallyfor control- and service works. For this purpose the indicationchannel MM, has to be set according to the following:MM=ModeManual for PG 53.02 and PG 54.02Manual operating mode0: control lamp flashes red/green. Relay 1 and 2 off1: control lamp flashes red/green. Relay 1 on, relay 2 off2: control lamp flashes red/green. Relay 1 off, relay 2 on3: control lamp flashes red/green. Relay 1 and 2 on4: control lamp flashes red or green (depending on

operation status). Automatic operation.MM=ModeManual for PG 51.02 and PG 52.02Manual operating mode0: control lamp flashes red/green. Relay 1 off1: control lamp flashes red/green. Relay 1 on2: control lamp flashes red or green (depending on

operation status). Automatic operation.

3.2.14 Operating mode (MMMMMMMMMM)

MM R1 R20 off off1 on off2 off on3 on on4 auto autoPG 53.02/PG 54.02

MM R10 off1 on2 autoPG 51.02/PG 52.02

3.2.12Collector cooling function

Collector cooling function (FN 3FN 3FN 3FN 3FN 3):If the adjusted maximum store temperature is reached, thesolar system switches-off. If the collector temperature nowraises up to the adjusted maximum collector temperature(CXCXCXCXCX), the solar pump remains activated until this limittemperature value is again underrun. The store temperaturemay increase - but only up to 90 °C (store safety shutdown).If the maximum store temperature (SX) is exceeded by thestoretemperature and the collector temperature is al least5K below the store temperature, the solar system remainsrunning until the store is cooled down to the adjustedmaximum store temperature (SX) by the collector and thepipes.

3.2.13 Mininum pump speed The indication channel PN makes it possible to preadjusta minimum value for the relative rotational speed of thecomponent connected to R1. 100% have to be adjusted(rotational speed deactivated) for components which arenot RPM-regulated.

only PG 53.02 and PG 54.02

Page 11: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 11/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

20

4 (1) A 250 V~

4. Commissioning

Ac power supply must be activated. The controller passesan initialisation phase in which the operating control lampflashes red and green. After having finished the initialisation,the controller is in automatic operation, which is the mosteffective one for most of the systems with the indicatedfactory settings.

If individual conditions require an adaptation of theparameter, please adjust the values accordingly (see 3.2).

5. Tips for fault location:Please check the following points if the controllerRESOL DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B does not work faultlessly:

1. Power supplyIf the operating control lamp is off, please check the powersupply of the controller.

The controller is protected by one can fuse T4 A, which issituated at the base/isolation plate and can be replaced byopening the cover of the housing (spare fuse is enclosed inone of the accessory bags).

2. Sensor faultsIf there is a malfunction due to a sensor defect, the operatingcontrol lamp flashes red and the symbol is shown on thedisplay (T3 is not affected). An error code for the concernedsensor is shown on the display (TC, TS or TT). The pushbuttonkey <+> must once be pressed for checking the 3rdtemperature sensor.

Short-circuit: Short-circuit in the sensor wire withindication of the concerned temperature sensor (TC, TS orTT). The error code -888.8 is shown on the display.

Line break: Interruption of the sensor wire withindication of the concerned temperaturesensor (TC, TS or TT). The error code888.8 is shown on the display for theconcerned sensor.

Clamped Pt1000-temperature sensors can be checked by aresistance-measuring device. The measured temperatures canbe compared with the resistance values of the table opposite.

resistance values ofPT1000 sensors

can fuse T4A

green constantly: at least one relay ist switched-ONred constantly:: all relays are switched-OFFred/green flashing: initialisation phase

sensor defectmanual operation

3.2.16 LED blinking codes

Attention!Before opening the housingplease make sure that all polesare separated from the linevoltage.

Depending on the PG versionthe picture above is varying fromyour controller!

Page 12: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 12/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

2

4

1S1

S2

3

S3

2

1

4

S1

S2

3 S3

6. Examples6.1 Solar system with 1 collector and 1 store:

Solar irradiation transfers heat, which is made utilizable bythe heat exchanger of the store (4), via collector (2) to thesystem. The controller (1) measures the temperaturedifference between collector sensor S1 and store S2. Assoon as this difference is higher or identical to the adjustedvalue (DO), the pump (3) is started and the store is loaded

up. If the switch-off temperature difference (DF) is underrunby this difference, the pump is stopped.

The 3rd temperature sensor S3 is an additional sensor formeasuring purpose, e.g. for measuring the upper storetemperature.

6.2 Solar system with 1 collector, 1 store and afterheating (only PG 53.02/54.02):

Solar irradiation transfers heat which is made utilizable bythe heat exchanger of the store (4) via collector (2) to thesystem (2). The controller (1) measures the temperaturedifference between collector sensor S1 and store sensor S2.As soon as this difference is higher or identical to theadjusted value (DO), the pump (3) is started and the storeis loaded up. If the switch-off temperature difference (DF)is underrun by this difference, the pump is stopped.

The 3rd temperature sensor S3 can be used for thermostatfunction. The thermostat switch-on temperature (TO) andthe switch-off temperature (TF) must be adjusted in the

adjustment channels. Depending on your adjustment, thethermostat function works in after-heating or coolingopertion.

Necessary adjustments for store after-heating:

TO = 40 °CTF = 45 °C

The adjustmens can be adapted to the individual systemconditions.

Page 13: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 13/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

1

S1 2S2

3

1

S1

2S2

3

4

The controller (1) compares the temperature measured bysensor S1 at the buffer store (2) with the reverse tem-perature at measuring sensor S2. If the measured tem-perature difference is higher or identical to the adjusted

6.3 Reverse raising of the heating circuit:

value ∆T, the reverse temperature is increased by thewarmth of the buffer store when connecting the 3-way-valve (3)(heating support) .

The controller (1) compares the temperatures measuredby sensor S1 in the boiler or chimney boiler (2) with thetemperature measured by sensor S2 in the store (3). If themeasured temperature difference is higher or identical tothe adjusted value DO (switch-on temperature difference),the pump (4) is activated, if the adjusted minimumtemperature (CN, adjustment range 10,1 ...90 °C) issimultaneously reached or exceeded. If the switch-off

6.4 Loading of the store by solid fuel boiler or chimney boiler:

temperature difference DF or the minimum temperature isunderrun, the pump switches-off.

Necessary adjustment for minimum temperature limitation(to avoid flue gas condensation):

CN = 60 °C (recommended)

Page 14: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 14/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

S1

S2

1

3

S1

S2

3

1

2

6.5 After-heating of the boiler by buffer store:

The controller(1) measures the temperature differencebetween buffer store sensorS1 and store sensor S2. As soonas the difference is higher or identical to the adjusted value(DO), the pump (3) is activated and the store is loaded up.If the switch-off difference (DF) is underrun by the measureddifference, the pump is again deactivated.

The 3rd temperature sensor S3 is an additional sensor formeasuring purpose, e.g. for measuring the upper storetemperature.

6.6 Swimming pool solar system:

The controller (1) measures the temperature differencebetween collector sensor S1 and swimming pool reversesensor S2. As soon as the difference is higher or identicalto the adjusted value (DO), the pump (3) is activated so thatthe water in the pool is heated up. If the switch-offdifference (DF) is underrun by the measured difference, thepump is again deactivated.

The 3rd temperature sensor S3 is an additional sensor formeasuring purpose, e.g. for measuring the upper storetemperature.

Page 15: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 15/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

S3

1

6.7 Thermostat after-heating function (only PG 53.02):

The third temperature sensor S3 can be used for thethermostat function. The thermostat switch-ontemperature TO and the thermostat switch-off temperatureTF must be adjusted in the adjustment channels. Dependingon the adjustment, the thermostat function works in after-heating or cooling operation.

to = 40 °C, tf = 40 °C

• to = tfthe thermostat function is deactivated, that meansthat relay output R2 is activated if the maximum storetemperature is exceeded

• To < Tfthe thermostat function is used as after-heating

• To > Tfthe thermostat function is used as surplus energy

Page 16: Mounting Connection Operation Examples · D eltaS ol ® B RESOL DeltaSol® B Mounting Connection Operation Examples Thanks for buying a RESOL. Read this manual carefully to get the

DDDDDeltaSeltaSeltaSeltaSeltaSololololol®®®®® B Page 16/16

© R

ESO

L 05

034

delta

sol_

b.m

onen

.pm

d

RESOL - Elektronische Regelungen GmbH

Heiskampstraße 10D - 45527 Hattingen

Tel.: +49 (0) 23 24 / 96 48 - 0Fax: +49 (0) 23 24 / 96 48 - 55

[email protected]

Your wholesaler:

NotesDesign and specifications are subject to change without notice.Illustrations may differ slightly from production models.