Ravenna™ IPI / TCC Page 1 of 2 P/N 506035-43, REV. NC, 03/2012 Input (BTU) - Electronic Models Fuel RDV40 IPI/TCC RDV33 IPI/TCC Input Rate (BTU / HR) Nat. Gas Hi 40,000 Lo 28,000 Hi 33,000 Lo 24,000 LP Gas Hi 37,500 Lo 26,000 Hi 33,000 Lo 24,000 Efficiency RDV40 IPI/TCC RDV33 IPI/TCC EnerGuide P4 67.17% - NG 69.07% - LP 65.55% - NG 67.80% - LP Steady State** 83%–86% 83%–86% DIRECT VENT FIREPLACE INSERT Appliance Specifications Insert Dimensions This insert has been tested and cer- tified by OMNI -Test Laboratories to ANSI Z21.88 / CSA 2.33 Standard for Vented Gas Fireplace Heater and CGA 2.17-M91 and UL 307B Gas Burning Heating Appliances for Manufactured (Mobile) Homes in both USA and Canada. New York City, New York (MEA#: 138-07-E). Commonwealth of Massachusetts (G3-1104-102) Note: Diagrams, illustrations and photographs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice. Listing Information ** Efficiency varies slightly with various pipe configurations. Top View Left Side View Right Side View Front View 31-1/8" (791mm) 15-7/8" (403mm) 13-3/8" (340mm) 15-7/8" (403mm) 19-3/8" (492mm) O.D. = 2-15/16" (75mm) This fireplace insert is factory equipped for 40,000 BTU input and can be converted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas or P/N H5925 for Propane Gas). Hearth Protection MINIMUM CLEARANCES Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible or equiva- lent, with a k factor of .84. A D B E C C L MINIMUM FIREPLACE SIZES REQUIRED .................... RDV40 IPI/TCC RDV33 IPI/TCC Front Opening Width ....................................................... 31.50” (800mm) 31.50” (800mm) Height ................................................................................. 19.50” (495mm) 19.50” (495mm) Rear Width ........................................................................ 19.00” (483mm) 19.00” (483mm) Depth ................................................................................. 16.00” (406mm) 16.00” (406mm) MINIMUM CLEARANCES TO COMBUSTIBLES A = Top Facing to Bottom of Appliance ..................... 35.5" (902mm) 31.5" (800mm) B = Side Facing or Side Wall to Center of Glass ...... 25.5" (648mm) 25.5" (648mm) * C = 10.5” (267mm) Mantel to Bottom of Appliance . 43" (1092mm) 39" (991mm) HEARTH PROTECTION D = Vertical Distance from base of appliance 0" 2” 4” 0" 2” 4” to Hearth Extension .......................................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm) E = Minimum Horizontal Distance 14" 10” 0” 13" 10” 0” from Front of Appliance.................................. (356mm) (254mm) (0mm) (330mm) (254mm) (0mm) MANTEL FACING Insert Clearances Report # 100501897PRT-001

Ravenna™ IPI / TCC - woodstoves.net · Ravenna™ IPI / TCC Options Standard Features • Realistic log set • Heavy, 14-gage aluminized steel firebox construction • Approved

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Ravenna™ IPI / TCC

Page 1 of 2P/N 506035-43, REV. NC, 03/2012

Input (BTU) - Electronic Models

FuelRDV40 IPI/TCC RDV33 IPI/TCC

Input Rate (BTU / HR)

Nat.Gas

Hi 40,000Lo 28,000

Hi 33,000Lo 24,000

LPGas

Hi 37,500Lo 26,000

Hi 33,000Lo 24,000

EfficiencyRDV40 IPI/TCC

RDV33 IPI/TCC

EnerGuide P4

67.17% - NG69.07% - LP

65.55% - NG67.80% - LP

Steady State**

83%–86% 83%–86%

DIRECT VENT FIREPLACE INSERTAppliance Specifications

Inse

rt Di

men

sions

This insert has been tested and cer-tified by OMNI -Test Laboratories to ANSI Z21.88 / CSA 2.33 Standard for Vented Gas Fireplace Heater and CGA 2.17-M91 and UL 307B Gas Burning Heating Appliances for Manufactured (Mobile) Homes in both USA and Canada.

New York City, New York(MEA#: 138-07-E).

Commonwealth of Massachusetts (G3-1104-102)

Note: Diagrams, illustrations and photographs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice.

Listin

g Inf

orm

atio

n

** Efficiency varies slightly with various pipe configurations.

Top View

Left Side View Right Side ViewFront View

15-7/8

31-1/8

13-3/8

31-1/8"(791mm)

15-7/8"(403mm)13-3/8"

(340mm)

15-7/8

19-3/8

15-7/8"(403mm)

19-3/8"(492mm)

O.D. = 2-15/16" (75mm)

This fireplace insert is factory equipped for 40,000 BTU input and can be converted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas or P/N H5925 for Propane Gas).

Hearth Protection

MINIMUM CLEARANCES

Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible or equiva-lent, with a k factor of .84.

A

D

B

E

C

CL

MANTELTRIM

MINIMUM FIREPLACE SIZES REQUIRED .................... RDV40 IPI/TCC RDV33 IPI/TCCFront Opening Width ....................................................... 31.50” (800mm) 31.50” (800mm)Height ................................................................................. 19.50” (495mm) 19.50” (495mm)Rear Width ........................................................................ 19.00” (483mm) 19.00” (483mm)Depth ................................................................................. 16.00” (406mm) 16.00” (406mm)MINIMUM CLEARANCES TO COMBUSTIBLES A = Top Facing to Bottom of Appliance ..................... 35.5" (902mm) 31.5" (800mm) B = Side Facing or Side Wall to Center of Glass ...... 25.5" (648mm) 25.5" (648mm)* C = 10.5” (267mm) Mantel to Bottom of Appliance . 43" (1092mm) 39" (991mm)HEARTH PROTECTION D = Vertical Distance from base of appliance 0" 2” 4” 0" 2” 4” to Hearth Extension .......................................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm) E = Minimum Horizontal Distance 14" 10” 0” 13" 10” 0” from Front of Appliance .................................. (356mm) (254mm) (0mm) (330mm) (254mm) (0mm)

MANTELFACING

Inse

rt Cle

aran

ces

Report # 100501897PRT-001

Printed in U.S.A. © 2012 Lennox Hearth Products P/N 506035-43 REV. NC 03/2012 Page 2 of 2

Ravenna™ IPI / TCC

Optio

nsSt

anda

rd Fe

atur

es

• Realistic log set• Heavy, 14-gage aluminized

steel firebox construction• Approved for zero-clear-

ance (metal) and masonry fireplaces

• Battery back-up in case of power outage

• Standard 155-CFM variable-speed blower delivers warm, consistent heat

3"/76mm

3"/76mm

3"/76mm1-1/2”38mm

35-1/2”902mm

37-1/2”953mm

40-1/2”1029mm

43-1/2”1105mm

3"/76mm

3"/76mm

3"/76mm1-1/2”38mm

31-1/2”800mm

33-1/2”851mm

36-1/2”927mm

39-1/2”1003mm

RDV40 IPI/TCCRDV33 IPI/TCC

Vent

Kits

Facin

g and

Man

tel C

leara

nces

Typi

cal In

stalla

tion

Decorative Faces(one required) Traditional and Arch inset

Foundry™ Screen

Cast Pillar

Screen Face

Contemporary Face

Surround Kits(one required)• Traditional 1-pc. (41"W x 29"H)

• Traditional 3-pc.(41"W x 29"H,

48"W x 29"H, 41"W x 33"H or 48"W x 33"H)

• Cast Iron (45-1/2"W x 30"H-Cast Pillar face only)

Misc. OptionsGT Remote Control Kit (IPI only)

ZC Lower Finish Panel/Reg Face Support

ZC Front Support Extension

Vertical Cap

Termination Connector

Exhaust

Intake

Combustion Air Intake

The existing fireplace chimneys may take various contours which the flexible liners will accommodate. However, keep the flexible liner as STRAIGHT as possible, avoid unneces-sary bending.

Liner Requirements:

Vertical Height Min. = 10 ft. (3.1 M)Vertical height Max. = 35 ft. (10.7 M)Note: Measured from flue collar on unit to the end of the vent pipe or liner

Use 3" (76 mm) diameter listed gas vent liner (UL1777 ONLY) for the EXHAUST

Use 3" (76 mm) diameter listed liner(UL 181 or UL1777) for the AIR INTAKE

The flexible vent pipe must NOT be allowed to sag behind insert or in fireplace flue.

The standard cap in Termination Kit TKDVI, and in Vent Kit DV3FK35 is a high wind cap

Product Reference Information

Cat. No.

Description Ship. Weight

Ship. Volume

H8450 Ravenna IPI 144 lb. 16.9 cu. ft.

H8451 Ravenna TCCTotal Comfort Control

144 lb. 16.9 cu. ft.

Firebox Liner Kits (one required)Tan Brick

Architectural Stone

Red Brick

Zen Garden

Simpson Dura Vent -

• Flex Liner 3” X 35’ - #3DFA-35• Adaptor w/ Flashing - #46DVA-GK• Termination Cap - #46DVA-VCH With

#460 DVA-VWG• Termination Cap - #460DVA-VG• Co-Linear Kit w/ 3” X 35’ Flex

Liner (Intake and Exhaust), Adaptor, Flashing and Termination Cap - #46DVA-CL33

Selkirk -

• Flex Liner 3” X 35’ - #AF35-03• Flex Liner 3” X 25’ - #AF25-03• Flex Liner 3” X 15’ - #AF15-03• Adaptor w/ Flashing - #4DT-CTB• Termination Cap - #4DT-VT

Amerivent -

• Flex Liner 3” X 35’ - #3AFL-35• Adaptor w/ Flashing - #4DCAT33• Termination Cap - #4DVC