2
 Profiles Products Show OEM Services Trade Dept. Forum Contact us Homepage  Contact: Tel: +86 574 8790 5657 +86 574 8790 5216 Fax: +86 574 8790 5852 E-mail: [email protected] Add: Room 2-26-2, innovation Center, Ning bo Hi-T ech Par  Products Show  English >> Products >> Gas Sens or >> QM -NG1  QM-NG1 Ty pe Gas Sensor us es SnO2 material as impressible material. SnO2 material is most advanced in the world at pr esen t, and being us ually in cosm icall production. The charact eristic of the product is with High sensitivity for all flammable and poisonous gas, Long inductiv e time, Long res umptive t ime, and Lon g life-span ect. Applications  Exhaus t fan, Toy , A ir cleaner, Smog inductor, Gas annunciator and all pla ce polluted ect. Sructure Ci rcui t diagram Specifications Calefaction V oltage (V H) AC or DC 5±0.2V Loop V ol tage(V C) Max . DC 24V Load Resi stance(RL) 2k Output in clean air(V0) ?.2V Si gnal Output(V 01) V0+1; 3V0 Inductiv e Time 10S Resumptiv e Ti me(tres) 30S Power 0.7W Life-span 5 Years Operati on me thod and cautions 1. When working with electric circuit and has not met gas tes ted, t he ele-conductance is on the increase, then being s tabiliz ation after one m inute, just it is use d normally. I n this change course, we can adopt overtime disp osal . 2. It mus t be in v oltage range when us ed, because the change of calefact ion volt age can directly effect the capability . 3. The V oltage of load resis tance can be per.80 of dispers ion(Vdg-V a)(Induct iv e Time) when s ensor 2010/2/3 Ningbo Hi-Tech Park SKKY Science T… skky.com.cn/english/qm-ng1.html 1/2

QM NG1 Specification

Embed Size (px)

Citation preview

Page 1: QM NG1 Specification

8/6/2019 QM NG1 Specification

http://slidepdf.com/reader/full/qm-ng1-specification 1/2

 

Profiles

Products Show

OEM Services

Trade Dept.

Forum

Contact us

Homepage

 

Contact:

Tel:+86 574 8790 5657

+86 574 8790 5216

Fax:+86 574 8790 5852

E-mail:[email protected]

Add:

Room 2-26-2, innovation

Center, Ningbo Hi-TechPar 

 

Products Show  

English >> Products >> Gas Sens or >> QM-NG1

  QM-NG1 Type Gas Sensor us es SnO2 material asimpressible material. SnO2 material is most advanced in

the world at present, and being us ually in cosm icall

production. The characteristic of the product is with High

sensitivity for all flammable and poisonous gas, Long

inductive time, Long resumptive time, and Long life-span

ect.

Applications

  Exhaust fan, Toy, Air cleaner, Smog inductor, Gas annunciator and all place polluted ect.

Sructure Circuit diagram

Specifications

Calefaction Voltage (VH) AC or DC 5±0.2V

Loop Voltage(VC) Max. DC 24V

Load Resistance(RL) 2k

Output in clean air(V0) ?.2V

Signal Output(V01) ≥V0+1; ≥3V0

Inductive Time ≤10S

Resumptive Time(tres) ≤30S

Power ≤0.7W

Life-span 5 Years

Operation method and cautions

1. When working with electric circuit and has not met gas tes ted, the ele-conductance is on the

increase, then being s tabilization after one m inute, just it is used normally. In this change course,

we can adopt overtime disposal .

2. It mus t be in voltage range when used, because the change of calefaction voltage can directly

effect the capability .

3. The Voltage of load resis tance can be per.80 of dispers ion(Vdg-Va)(Inductive Time) when sensor 

2010/2/3 Ningbo Hi-Tech Park SKKY Science T…

skky.com.cn/english/qm-ng1.html 1/2

Page 2: QM NG1 Specification

8/6/2019 QM NG1 Specification

http://slidepdf.com/reader/full/qm-ng1-specification 2/2

meets the hydrogen of 500ppm in 10 seconds. The voltage of load resis tance can be per.80 of 

dispersion(Vdg-Va) (Rdsumptive Time) when sensor leave the hydrogen of 500ppm in 30

seconds.

4. Symbol specification

Resis tance in tested gas Rdg Voltage in tested gas Vdg

Resis tance in tested gas Rig Voltage in tested gas Vig

Relation of Rdg and Vdg Rdg=Rl(Vc/Vdg-1)

Relation of Rig and Vig Rig=Rl(Vc/Vig-1)

5. Load res istance can be changed properly if require, the change will not effect the sensi tivity.

6. Condition

Temp.:-15~35?C

Relative Humidi ty: 45~75%RH

Amospheric Pessure:80~106Kpa

7. When used in precision instrument, sensor should carry on the warm humidity to compensate,

because the change of warm humidi ty can effect the resis tance.The bes t way for the following just

adopt Thermal resistor.

8. Avoid to be put in caustic gas and oil, and jammed by dust for stainless s teel network of the

explos ion-proof when used chronically.

9. Six foot positions of componet can be matched and used with senven corners of electron seat.

CopyRight ® 2003 Ningbo Hi-Tech Park SKKY Science Technology Co.,Ltd.

2010/2/3 Ningbo Hi-Tech Park SKKY Science T…