4
PUMP SELECTION – EXAMPLE 1 Duty Capacity : 20 m 3 /hr Viscosity : 100 CPS Discharge : 7 Bar Step 1 Select pump model, using Viscosity Limitations Graph (Section D - Part 2 Page 2.3). Model R32. Step 2 Using Performance graph R32S, find point A, using Viscosity and Discharge Pressure. Step 3 The diagonal dotted line from A, gives pumps performance at any flow rate, at these viscosity and pressure conditions. Step 4 Using capacity of 20 m 3 /hr, find point B. From this point, by projecting vertically upwards and downwards, the following can be found: C Pump speed : 900 RPM D Power required : 5.6 kW E Maximum pressure : 8 Bar F Maximum viscosity : 7 Poise (700 CPS) G NPSH required : 4.5 Metres Section D - Part 3 Issue No.: 3 Page 3.1 Issue Date : 1 July 2005 Back

PUMP SELECTION – EXAMPLE 1...Section D - Part 3 Issue No.: 3 Page 3.1 Issue Date : 1 July 2005 Back PUMP SELECTION EXAMPLE No 1 r.p.m. 100 200 300 400 500 600 700 800 900 1000 BAR

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • PUMP SELECTION – EXAMPLE 1 Duty Capacity : 20 m3/hr Viscosity : 100 CPS Discharge : 7 Bar Step 1 Select pump model, using Viscosity Limitations Graph (Section D - Part 2 Page 2.3). Model R32. Step 2 Using Performance graph R32S, find point A, using Viscosity and Discharge Pressure. Step 3 The diagonal dotted line from A, gives pumps performance at any flow rate, at these viscosity and pressure conditions. Step 4 Using capacity of 20 m3/hr, find point B. From this point, by projecting vertically upwards and downwards, the following can be found: C Pump speed : 900 RPM D Power required : 5.6 kW E Maximum pressure : 8 Bar F Maximum viscosity : 7 Poise (700 CPS) G NPSH required : 4.5 Metres Section D - Part 3 Issue No.: 3 Page 3.1 Issue Date : 1 July 2005

    Back

  • PUMP SELECTIONEXAMPLE No 1

    r.p.m. 100 200 300 400 500 600 700 800 900 1000

    BAR

    1

    2

    3

    5

    7

    10

    14.5

    29

    43.5

    72.5

    10.15

    145

    10 CP

    50 CP

    100 CP

    300 CP

    200 CP

    P.S.I.

    1 CP

    10BA

    R

    8 BAR

    6 BAR

    2 BAR

    1 BAR

    4 BAR

    7.5

    5.5

    4

    3

    2.2

    1.5

    1.1

    KW

    POWER VISCOSITY

    24

    20

    15

    10

    5

    0

    500

    1000

    1500

    2000

    2500

    3000

    3500

    4000

    4500

    5000

    5500

    6000

    6340

    0

    500

    1000

    1500

    2000

    2500

    3000

    3500

    4000

    4500

    5000

    5729

    0

    300 130 65 43 28 21 17

    10 9

    11

    3.61.5 2.1 2.8

    8 7

    4

    5.5

    7

    MAX PRESSURE (BAR)

    MAX VISCOSITY (POISE)

    NPSHR (METRE)

    US

    .gp

    h

    IMP.g

    ph

    M3/h

    B

    C

    A

    E

    F

    G

    ROTOFLO R32SPERFORMANCE CURVE

    D

    D212Section D - Part 3

    Page 3.2 Issue Date : 1 July 2005 Issue No. : 3

  • PUMP SELECTION – EXAMPLE 2 Duty Capacity : 20 m3/hr Viscosity : 6 000 CPS Discharge : 7 Bar Step 1 Select pump model, using Viscosity Limitations Graph (Section D - Part 2 Page 2.3). Model R42. Step 2 Using Performance graph R42, find point A, using Viscosity and Discharge Pressure. Step 3 The diagonal dotted line from A, gives pumps performance at any flow rate, at these viscosity and pressure conditions. Step 4 Using capacity of 20 m3/hr, find point B. From this point, by projecting vertically upwards and downwards, the following can be found: C Pump speed : 300 RPM D Power required : 5 kW E Maximum pressure : 10 Bar F Maximum viscosity : 120 Poise (12 000 CPS) G NPSH required : 1.9 Metres Section D - Part 3 Issue No.: 3 Page 3.3 Issue Date : 1 July 2005

  • 10BA

    R8 B

    AR 6 BAR

    2 BAR

    4 BAR

    r.p.m. 100 200 300 400 500 600 700 800 900 1000

    700 300 120

    1.6

    90

    2.2

    55

    10

    35

    3.1

    25

    8

    18

    4.1

    12 8

    7

    6

    MAX PRESSURE (BAR)

    MAX VISCOSITY (POISE)

    NPSHR (METRE)

    US

    .gp

    h

    IMP.g

    ph

    M/h

    3

    65

    60

    50

    40

    30

    20

    10

    0

    17177

    16000

    15000

    14000

    13000

    12000

    11000

    10000

    9000

    8000

    7000

    6000

    5000

    4000

    3000

    2000

    1000

    0

    1000

    2000

    3000

    4000

    5000

    6000

    7000

    8000

    9000

    10000

    11000

    12000

    13000

    14298

    0

    PUMP SELECTIONEXAMPLE No 2

    D213Section D - Part 3

    Page 3.4 Issue Date : 1 July 2005 Issue No. : 3

    1

    2

    3

    5

    7

    10

    300 CP

    200 CP

    100 CP

    50 CP

    10 CP

    1 CP

    145

    101.5

    72.5

    43.5

    29

    14.5

    P.S.I.

    BAR

    18.5

    15.0

    11.0

    7.5

    5.5

    3

    0

    KW

    POWER VISCOSITY

    4

    ROTORFLO R42PERFORMANCE CURVE

    F G

    E

    B

    C

    D