  • NIBE AB Sweden- Box 14, Jrnvgsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433 - 73 000 Fax: +46-(0)433 - 73 190 E-mail: [email protected] www.nibe.com

    TIF GB 0815-3 PAGE 1 (3)

    M10293 - FIGHTER 1240 with ground water system

    ApplicationHouses.

    FunctionFIGHTER 1240 can be connected to a water table well. in which case an intermediate heat exchanger (65) is used to protect the heat pumps exchanger from dirt. The wa-ter is released into a buried filtration unit or a drilled well.

    Available groundwater flow should be 25% higher than requisite brine flow.

    See the appropriate Installation and Maintenance Instructions for more information.

    63

    65

    66

    15

    63

    44

    44 44 52

    84

    64

    31

    Note! This is an outline diagram. Actual installations must be planned according to applicable standards.

  • NIBE AB Sweden- Box 14, Jrnvgsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433 - 73 000 Fax: +46-(0)433 - 73 190 E-mail: [email protected] www.nibe.com

    TIF GB 0815-3 PAGE 2 (3)

    M10293 - FIGHTER 1240 with ground water system

    List of Components

    Pos

    Name Specification Manufacturer Remarks

    15 Outside temperature sensor NIBE Included in FIGHTER 1240

    31 Auxiliary contactor

    44 Shut-off valve

    52 Safety valve Included in FIGHTER 1240

    63 Particle filter NIBE Included in FIGHTER 1240

    64 Particle filter, groundwater

    65 Heat exchanger, groundwater Plex NIBE

    66 Groundwater pump

    84 Level vessel NIBE Included in FIGHTER 1240

  • NIBE AB Sweden- Box 14, Jrnvgsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433 - 73 000 Fax: +46-(0)433 - 73 190 E-mail: [email protected] www.nibe.com

    TIF GB 0815-3 PAGE 3 (3)

    M10293 - FIGHTER 1240 with ground water system

    FIGHTER 1220/1230FIGHTER 1120/1130

    Start equipment for groundwater pump

    E29:X1b:28-29 in FIGHTER 1240

    The groundwater pump (66) is connected in parallel through the heat pumps brine pump via a contactor. Positions E29:X1b:28-29 may not be subject to output from the groundwater pump. Auxiliary contactor is dimensioned based on the voltage needs of the groundwater pump.

    FIGHTER 1240

    F-1235/40 3x400V+tillbehrskortF-1235/40 3x400V

    F-1235/40 3x400V leveranskoppling

    L1N L2 L3 PE

    F-1235/40 3x400V tariffkoppling

    L10LN L2 L3 PEL1 L2 L3 PE

    LEK

    LEK LEK

    LEK

    LEK

    -E29

    -X1b

    E29:X1b

    28 29