4
Performance Optimization for Oil & Gas Extraction Pump - Off Controller

Optimization Pump - Off Controller - Home - INTECH · PDF fileand control rod pumps at the well site or by using telemetry and SCADA systems. PUMP-OFF CONTROLLER (POC) ... Non Linear

Embed Size (px)

Citation preview

Page 1: Optimization Pump - Off Controller - Home - INTECH · PDF fileand control rod pumps at the well site or by using telemetry and SCADA systems. PUMP-OFF CONTROLLER (POC) ... Non Linear

Performance

Optimization

for Oil & Gas

Extraction

Pump - OffController

Page 2: Optimization Pump - Off Controller - Home - INTECH · PDF fileand control rod pumps at the well site or by using telemetry and SCADA systems. PUMP-OFF CONTROLLER (POC) ... Non Linear

INTECH’s value resides in software algorithms embedded in the Rugged PC, which

requires no external sensors, wires, load cells or other field devices. The POC uses

technology that analyzes the motor’s rotor relationship to the stator to determine

load and position. As with traditional Pump-Off Controllers, pump-off is determined

when the load is reduced at specific positions. Unlike traditional Pump-Off

Controllers, INTECH’s POC can be integrated via GSM, radio, fiber or Ethernet and

report problems such as pump-off, parted rod, leaking valve, high load and

minimum load, even shutting down if conditions warrant. All this data is available

via ModBus Ethernet as read and write values. INTECH’s POC allows you to monitor

and control rod pumps at the well site or by using telemetry and SCADA systems.

PUMP-OFF CONTROLLER (POC)

SYSTEM ARCHITECTURE

Pump-Off Processor

WIFI

RADIO

GPRS / GSM

COPPER / FIBER

Intelligent Motor Controller

1

23 4

5

6

Page 3: Optimization Pump - Off Controller - Home - INTECH · PDF fileand control rod pumps at the well site or by using telemetry and SCADA systems. PUMP-OFF CONTROLLER (POC) ... Non Linear

PANEL SPECIFICATIONS

INTELLIGENT MOTOR CONTROLLER

INDUSTRY EDGE

PUMP-OFF PROCESSOR

Description

4- Port Ethernet Switch

Motor Contactor for 30-50 HP MotorEthernet Remote IO

Rod position sensor(wireless)

Description

Display Panel

Fanless Rugged PC

6-8 Port Ethernet Switch

Cloud Gateway

Wifi access point

FEATURES

BENEFITS DELIVERED

IMPROVE OPERATIONS EFFICIENCYRemote data collection from distant data points allows you to react more effectively and efficiently to real time changes in production conditions.

INTECH systems are easy to configure and allow faster and easier mapping over networks. The time you save in setting up the solution can be utilized in getting well pads running sooner.

FASTER DEPLOYMENT

MAXIMIZE LIFETIME PRODUCTIONINTECH’s easy and cost effective installation helps reduce costs and ensure better returns on asset investment. INTECH systems are safe and reliable; lowering OPEX costs through reduced disruptions, which also extends the production life of wells.

INTECH's solution sets a benchmark for quick andeasy installation, and enables production in remote locales and harsh weather conditions. The POC equipment is certified NEMA-4X.

HARSHCONDITIONS

EASY DISTRIBUTED SOLUTIONSINTECH's POC solution is easily networked on the wellpad wirelessly for faster system commissioning and monitoring, and faster production without need for trenching and wiring time delays.

INTECH’s ready-to-use solutions can be easily configured and attached to any network to increase network size. Wireless operations allow these solutions to be easily removed and installed at new locations.

SCALABLE AND REUSABLE

VSD (optional)

Protection Functions

Core Differentiation

Ambient Temperature

DC overvoltage

DC under voltage

Drive temperature

Input phase loss

Overcurrent

Power limits

Short circuit

Software FeaturesData Mining:

Torque computed through Current (and Voltage) and beam displacement

Non Linear (Current) function Model development

Visual interface:

Rod Pump Analytics

Dyno-graph with Calculations

Operational:

Automatic start & reset

Diagnostics & Notifications

60-Day Log for Pump Curve

Programmable I/O

OPC integration

Non-linear model for wells of all depths

Small footprint; less-intrusive, easy installation

Combined well-test data for accurate performance prediction

Derived DifferentiationEarly detection of anomalies and prevention

Flexible communication options

Quick to install and limited number of dependent sensors needed

Deployment DifferentiationRTU with Local Pump-Off Function

Power (incl. auxiliary equipment) under 30W

Base Function (Remote Server Based), Beaming to Cloud option

Page 4: Optimization Pump - Off Controller - Home - INTECH · PDF fileand control rod pumps at the well site or by using telemetry and SCADA systems. PUMP-OFF CONTROLLER (POC) ... Non Linear

Notice: All registered logotypes, trademarks, brands, product and services marks used in this document are acknowledged as properties of their respective companies/owners and such companies/owners have not consented to their use by INTECH (Term INTECH is used for INTECH Process Automation Inc. and its affiliates). INTECH is not affiliated with these logotypes, trademarks, brands, product and services marks and any use by INTECH should not be construed as an endorsement of INTECH or its services. The services described herein are provided solely by INTECH. © 2017. All rights reserved by INTECH Process Automation Inc. facebook.com/Intechprocessautomation

linkedin.com/company/intech-process-automation

Vendor Expertise Standards & Certifications

AmericasWORLD HQINTECH Process Automation Inc.4903 W. Sam Houston Parkway N. Suite A-100Houston, TX 77041, USATel: +1 713 849 1000 Fax: +1 713 856 0785

INTECH Process Automation Perú S.A.C.Av. República De Panamá N°3030 Oficina 7a San Isidro, Lima, Perú Tel: +511 606 6849Cel: +51 982117562

EuropeINTECH Process Automation Sarl168 Avenue Charles De Gaulle, 92 522 Neuilly-sur-seine Cedex, [email protected]

Central AsiaINTECH Process Automation LLP.5A Erniyazova Str. Atyrau, KazakhstanTel: +7 7122 32 01 16Fax: +7 7122 32 00 52

AsiaINTECH Process Automation Pte. Ltd600 North Bridge Road, #23-01 Parkview Square, Singapore 188778Tel: +65 68289118Fax: +65 68289112

PT INTECH Process AutomationRukan Permata Senayan, Blok C Nomor 5, 4th Floor,Jalan Tentara Pelajar, Kebayoran Lama,Jakarta Selatan, 12210 IndonesiaTel & Fax: +62 21 579 49 444

INTECH Process Automation (Shanghai) Co. Ltd.Room 1605c, 16f Feidiao International Building, No.1065 Zhaojiabang Road, Xuhui District,Shanghai 200030 – P.R.C.Tel: +86 21 2426 1951Fax: +86 21 2426 1877

INTECH Process Automation Pvt. Ltd.2nd Floor, Commercial Building #2PCSIR Phase – IILahore 54782, PakistanTel: +92 42 111 468 324, 3531 2509/11Fax: +92 42 3531 4149

Middle EastINTERNATIONAL HQINTECH Process Automation FZCOP.O. Box 61479, RA08ZC01, JAFZA, DUBAI, United Arab EmiratesTel: +971 4 8810056Fax: +971 4 8810057

INTECH Process Automation Inc. Br.G-201 Al-salah Tower, P.O. Box 4270, Al-khobar - 31952,Kingdom Of Saudi ArabiaTel: +966 13 8966052, +966 13 8966053

INTECH Process Automation FZCO Br. 470, Italian City, Erbil, Iraq Tel: +964 780 131 2198, +964 750 309 3766

North Africa OperationsTel: +971 55 607 3230, +971 553768482

Email: [email protected]

AfricaINTECH Process Automation Nigeria Ltd.64b, Abacha Link Road, G.R.A. III,Port Harcourt, Rivers State, NigeriaTel: +234 905 3992976

Liaisons Office,Victoria IslandsLagos, NigeriaTel: +234 805 [email protected]

INTECH Process Automation Inc.(Sucursal De Angola)Casa Nº B07, Condominio Boulevard, Via Al16, Talatona, Luanda - Republica De AngolaTel: +244 222 720 471Fax: +1 281 377 3455 [email protected]

[email protected]

www.intechww.com

End User EPC

What Our Customers Say...“I commend you on your efforts in customizing the business analysis software for trial deployment for a Web Based Alarm Management Dashboard. It meets our objectives and has produced the desired results.”

Control & Automation Leader

“[We] commend INTECH’s knowledge of alarm management, dedication, commitment and effort. Most importantly, works have been completed safely and INTECH has been able to work successfully in our diverse environment”

Central Maintenance Coordinator

“INTECH’s team worked with extraordinary zeal & efforts at the Adhi Electronic Flow Metering Project which included on-line trends and alarms of sales gas parameters’ limits. The competency level and performance of their deputed team is satisfactory and commendable. “

Deputy Chief Engineer

PPL

OEM