2
~~ ~ ~ ~ ~ ~ b / OPERATINGROOM ScoliosisOperating Frame Relton-Hall Scoliosis Operating Frame Product Overview Product Details · Designed to support the patient in the prone position during corrective operative procedures for scoliosis · Provides lateral stability · Reduces blood loss by keeping the anterior abdominal wall pendulous and free from external pressure · Positioning on the antero-Iateral supports facilitates correction of the scoliosis deformity · Radiolucent supports allow for intra- operative imaging Frame Assembly · The frame consists of four well padded vertical supports which are arranged in two V-shaped pairs · The supports are set at a 35 degree inward tilt and are individually adjustable for length and width · The frame is manufactured using both welded stainless steel for maximum patient support and radiolucent fiber- reinforced resin pad supports in order to allow for unobstructed visualization under imaging · Full adjustability is achieved with three-point phenolic knobs with welded positioning attachments Support Pads · The support pads are removable with a dual density foam core and double stitched anti-bacterial vinyl covering · Additional padding is provided by optional dry polymer pads specifically moulded for the Relton-Hall Frame to assist with the prevention of decubitus ulcers and necrosis which may result from procedures of extended duration '-./ 1935 .......J U) :::> '---' en .......J « w a... Montreal Toronto Vancouver V New Jersey California 1· 800.496.6060 Tel.: +1· 514. 631 · 7988 Fax: +1.514.631.9083

OPERATING ROOM Relt… · OPERATING ROOM Scoliosis Operating Frame. Product Selection o-,. Model # OR-6050 Dimensions (L x W x H) Overall: 24 in x 22 in x 61/4 in (610 mm x 559 mm

  • Upload
    others

  • View
    22

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OPERATING ROOM Relt… · OPERATING ROOM Scoliosis Operating Frame. Product Selection o-,. Model # OR-6050 Dimensions (L x W x H) Overall: 24 in x 22 in x 61/4 in (610 mm x 559 mm

~~~ ~~ ~~b

/ OPERATINGROOM

ScoliosisOperating Frame

~

,..

Relton-Hall Scoliosis Operating FrameProduct Overview Product Details

· Designed to support the patient in theprone position during correctiveoperative procedures for scoliosis

· Provides lateral stability· Reduces blood loss by keeping the

anterior abdominal wall pendulous andfree from external pressure

· Positioning on the antero-Iateralsupports facilitates correction of thescoliosis deformity

· Radiolucent supports allow for intra-operative imaging

Frame Assembly· The frame consists of four well padded

vertical supports which are arranged intwo V-shaped pairs

· The supports are set at a 35 degreeinward tilt and are individuallyadjustable for length and width

· The frame is manufactured using bothwelded stainless steel for maximumpatient support and radiolucent fiber-reinforced resin pad supports in orderto allow for unobstructed visualizationunder imaging

· Full adjustability is achieved withthree-point phenolic knobs with weldedpositioning attachments

Support Pads· The support pads are removable with

a dual density foam core and doublestitched anti-bacterial vinylcovering

· Additional padding is provided byoptional dry polymer pads specificallymoulded for the Relton-Hall Frame toassist with the prevention of decubitusulcers and necrosis which may resultfrom procedures of extended duration

'-./

1935

.......J

U):::>

'---' en.......J«wa...

MontrealToronto

Vancouver

V New JerseyCalifornia

1· 800.496.6060Tel.: +1· 514. 631· 7988Fax: +1.514.631.9083

Page 2: OPERATING ROOM Relt… · OPERATING ROOM Scoliosis Operating Frame. Product Selection o-,. Model # OR-6050 Dimensions (L x W x H) Overall: 24 in x 22 in x 61/4 in (610 mm x 559 mm

OPERATINGROOM

Scoliosis Operating Frame .Product Selection -,.

oModel #OR-6050

Dimensions (L x W x H)Overall: 24 in x 22 inx 61/4 in (610 mm x 559 mm x 159 mm)Length Adjustment: 3 1/4 in to 24 in (83 mm to 610 mm)Width Adjustment: 5 1/2 in to 14 1/2 in (140 mm to 368 mm)

Vinyl Pads (Set of four) 6 1/2 in x 5 1/4 in x 3 1/2 infor OR-6050 Operating Frame (165 mm x 133 mm x 89 mm)

Action @Products Pressure relief pads (set of 4). To be applied over vinyl pads.

DescriptionRelton-Hall Operating Frameclw Vinyl Pad Supports

OR-6050-P

~OR-6050-A

Product Application·The frame has been designed to properly support patients weighing up to 275 Ibs 1 125 kgFrame Preparation· The positioning knobs should be tested for proper operation and securely fastened prior to positioning the

patient to ensure total frame stability throughout the procedure· Ensure that the cushioned pads are securely fastened to the support frame in order to prevent patient

movement during the procedure· The operating table mid-section mattress should be removed from the operating table in order for the

operating frame to be positioned firmly on the table metal or radiolucent surface· It is recommended that the operating frame be securely fastened to the operating table using straps or velcro

fasteners to prevent the possibility of frame movement during the procedurePatient Positioning· The rostral pair of supports are applied to the lateral aspects of the upper thoracic cage, below the clavicles

and as far above the xiphisternum as is practicable· Position the patient so that the nipple line is in the middle of the upper support pad

· Female patients should have the breasts re-adjusted inward after being positioned on the operating frame I Jto ensure that pressure is applied to the lateral chest area and not directly on the breast tissue

· The supports should not encroach on the epigastrium· The caudal pair of supports are applied to the antero-Iateral aspects of the pelvic girdle between the iliac

crests and the greater femoral trochanters ensuring that they do not encroach on the lower parts of theanterior abdominal wall

· All potential pressure points should be well padded including the elbows, forearms, knees and lower legs toavoid complications from localized pressure

· The head should be well supported; It is essential to avoid any external pressure on the orbits· The tendency towards hyperextension of the vertebral column is partially counteracted by lowering the

legs, and, at the same time ensuring that the knees remain in a semi-flexed position· Adjusting the vertical supports as outlined above will assist with improved patient positioning and prevent

external pressures from being applied to the anterior abdominal wall during the procedure·The use of the Relton-Hall Operating Frame is not recommended during laminectomy for discprotrusion due to the lordotic position of the lumbar vertebrae resulting from this method of patientsupport

Reference:

RELTON,J.E.S. & HALL, J.E.: "Reduction of Hemorrhage during Spinal Fusion combined with InternalMetallic Fixation using a New Scoliosis Operating Frame" Brit. Journal of Bone and Joint Surgery.(Volume 49B 2:327 (1967))

IMPERIALSURGICALLTD.Montreal - Toronto - Vancouver - New Jersey - California

International: +1-514-631-7988 Fax: +1-514-631-9083o

Toll Free 800.496.6060Printedin Canada.6/00