Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
ENGINE EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 02-Dec-15
COPPER IS ELEVATED. ELEVATED COPPER LEVEL MAY BE DUE TO INCREASED OIL COOLER CORE LEACHING,
NOT WEAR. OTHER READINGS APPEAR TO BE NORMAL. RESAMPLE AT THE NEXT SERVICE INTERVAL.
INTERPRETATION BY MARY C. - LAB MANAGER
E330-45336-0087
LABEL#: 0087
SAMPLE SHIP TIME (days) : 2
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 02-Dec-15
SAMPLE INFORMATION
30-Nov-15
E330-45336-0087
02-Dec-15
750
250
CONOCO
15W-40
Y
Y
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
WEAR LEVELS / ADDITIVES
30-Nov-15
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 17
Fe Iron 16
Cr Chromium 0
Al Aluminum 3
Pb Lead 1
Sn Tin 0
Si Silicon 3
Na Sodium 2
K Potassium 2
Mo Molybdenum 6
Ag Silver 0
Ca Calcium 2237
P Phosphorus 966
Zn Zinc 1129
Mg Magnesium 47
PREVIOUS SAMPLE
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
30-Nov-15
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 13.4
INFRARED (UFM) ASTM E2412
ST Soot 9
OXI Oxidation 12
SUL Sulfur Products 18
NIT Nitration 5
WATER
W Water N
ANTIFREEZE
A Antifreeze N
FUEL
F Fuel N
FUEL CONTENT (%) ASTM D3524
PFc Percent Fuel 3.04
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
ENGINE
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-45336-0087
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
ENGINE EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 05-Dec-16
NORMAL WEAR METAL READINGS. OTHER ANALYSIS READINGS APPEAR TO BE ACCEPTABLE. NO PROBLEMS
PRESENTLY ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL.
INTERPRETATION BY MARY C. - LAB MANAGER (WEAR METAL TESTING PERFORMED BY CATERPILLAR)
E330-46333-0025
LABEL#: 0025
SAMPLE SHIP TIME (days) : 6
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 28-Nov-16
SAMPLE INFORMATION
22-Nov-16
E330-46333-0025
28-Nov-16
1750
1750
250
CONOCO
15W-40
Y
Y
0
U
16-Aug-16
E330-46239-0043
26-Aug-16
1500
250
CONOCO
15W-40
Y
Y
U
22-May-16
E330-46147-0027
26-May-16
1250
250
CONOCO
15W-40
Y
Y
U
01-Mar-16
E330-46063-0060
03-Mar-16
1000
250
CONOCO
15W-40
Y
Y
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
22-Nov-16 16-Aug-16 22-May-16 01-Mar-16
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 5 4 6 18
Fe Iron 10 9 10 16
Cr Chromium 0 0 0 0
Al Aluminum 1 2 3 3
Pb Lead 0 1 1 1
Sn Tin 0 0 0 0
Si Silicon 2 1 2 2
Na Sodium 1 0 0 1
K Potassium 1 0 1 2
Mo Molybdenum 0 0 1 2
Ni Nickel 0
Ag Silver 0 0 0 0
Ti Titanium 0
V Vanadium 0
Mn Manganese 0
Cd Cadmium 0
Ca Calcium 2268 2167 2233 2242
P Phosphorus 982 951 964 953
Zn Zinc 1103 1094 1115 1117
Mg Magnesium 11 18 17 18
Ba Barium 0
B Boron 2
PREVIOUS SAMPLE
NORMAL WEAR METAL READINGS. OTHER ANALYSIS READINGS APPEAR TO
BE ACCEPTABLE. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION
BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
22-Nov-16 16-Aug-16 22-May-16 01-Mar-16
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 13.4 13.4 13.6 13.7
INFRARED (UFM) ASTM E2412
ST Soot 15 13 11 8
OXI Oxidation 14 13 13 13
SUL Sulfur Products 20 19 19 19
NIT Nitration 6 6 6 6
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
FUEL
F Fuel N N N N
FUEL CONTENT (%) ASTM D3524
PFc Percent Fuel 0.57 0.42 2.31 2.19
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
ENGINE
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-46333-0025
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
ENGINE EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Rachel SmithNo Action Required
Interpreted On: 18-Jan-18
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT
THE NORMAL INTERVAL. INTERPRETATION BY RACHEL S. - FLUIDS TECH
E330-48015-0058
LABEL#: 0058
SAMPLE SHIP TIME (days) : 3
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 15-Jan-18
SAMPLE INFORMATION
12-Jan-18
E330-48015-0058
15-Jan-18
2750
2750
250
CONOCO
15W-40
Y
Y
U
13-Oct-17
E330-47306-0023
02-Nov-17
2500
2500
200
CONOCO
15W-40
Y
Y
U
13-Jun-17
E330-47167-0076
16-Jun-17
2250
2250
250
CONOCO
15W-40
Y
Y
0
U
22-Mar-17
E330-47089-0039
30-Mar-17
2000
2000
250
CONOCO
15W-40
Y
Y
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
12-Jan-18 13-Oct-17 13-Jun-17 22-Mar-17
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 2 2 2 4
Fe Iron 10 10 10 10
Cr Chromium 0 0 0 0
Al Aluminum 2 2 3 3
Pb Lead 1 0 1 0
Sn Tin 1 0 0 0
Si Silicon 2 3 0 2
Na Sodium 3 1 3 0
K Potassium 0 0 0 0
Mo Molybdenum 54 0 3 3
Ni Nickel 0
Ag Silver 0 0 0 0
Ti Titanium 0
V Vanadium 3
Ca Calcium 1407 2125 2094 2057
P Phosphorus 1142 865 921 910
Zn Zinc 1299 1009 1063 1030
Mg Magnesium 922 20 46 41
B Boron 2
PREVIOUS SAMPLE
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION
BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
12-Jan-18 13-Oct-17 13-Jun-17 22-Mar-17
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 13.9 14.0 13.1 13.6
INFRARED (UFM) ASTM E2412
ST Soot 9 13 13 7
OXI Oxidation 15 14 13 12
SUL Sulfur Products 20 19 19 18
NIT Nitration 7 6 6 6
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
FUEL
F Fuel N N N N
FUEL CONTENT (%) ASTM D3524
PFc Percent Fuel 0.57
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
ENGINE
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-48015-0058
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
ENGINE EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 01-Apr-19
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT
THE NORMAL INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-49091-0043
LABEL#: 0043
SAMPLE SHIP TIME (days) : 13
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 01-Apr-19
SAMPLE INFORMATION
19-Mar-19
E330-49091-0043
01-Apr-19
3750
250
CENEX
15W-40
Y
Y
U
26-Oct-18
E330-48319-0047
15-Nov-18
3500
3500
250
CENEX
15W-40
Y
Y
U
07-Aug-18
E330-48221-0053
09-Aug-18
250
250
250
CONOCO
15W-40
Y
Y
U
20-Apr-18
E330-48113-0063
23-Apr-18
3000
3000
200
CONOCO
15W-40
Y
Y
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
Comp Meter [Hr]
WEAR LEVELS / ADDITIVES
19-Mar-19 26-Oct-18 07-Aug-18 20-Apr-18
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 1 1 1 1
Fe Iron 6 6 9 4
Cr Chromium 0 0 0 0
Al Aluminum 1 1 2 1
Pb Lead 0 0 1 0
Sn Tin 0 0 0 0
Si Silicon 1 2 2 1
Na Sodium 1 2 2 2
K Potassium 0 1 1 1
Mo Molybdenum 46 33 34 48
Ag Silver 0 0 0 0
Ca Calcium 1041 1717 1374 1033
P Phosphorus 923 1027 920 949
Zn Zinc 1114 1173 1062 1113
Mg Magnesium 722 495 514 746
PREVIOUS SAMPLE
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION
BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
19-Mar-19 26-Oct-18 07-Aug-18 20-Apr-18
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 13.1 13.6 13.5 14.4
INFRARED (UFM) ASTM E2412
ST Soot 11 8 13 0
OXI Oxidation 16 14 14 14
SUL Sulfur Products 21 20 20 19
NIT Nitration 8 7 7 6
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
FUEL
F Fuel N N N N
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
ENGINE
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-49091-0043
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
ENGINE EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 22-Feb-21
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT THE
NORMAL INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-51053-0043
LABEL#: 0043
SAMPLE SHIP TIME (days) : 4
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 22-Feb-21
SAMPLE INFORMATION
18-Feb-21
E330-51053-0043
22-Feb-21
4750
250
CENEX
15W-40
Y
Y
U
07-Oct-20
E330-50290-0033
16-Oct-20
4500
CENEX
15W-40
Y
Y
U
20-Mar-20
E330-50098-0048
07-Apr-20
4250
246
CENEX
15W-40
Y
Y
U
20-May-19
E330-49154-0058
03-Jun-19
4000
250
CENEX
15W-40
Y
Y
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
WEAR LEVELS / ADDITIVES
18-Feb-21 07-Oct-20 20-Mar-20 20-May-19
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 2 1 1 0
Fe Iron 5 7 11 5
Cr Chromium 0 0 0 0
Al Aluminum 1 2 2 1
Pb Lead 0 0 1 0
Sn Tin 0 0 0 0
Si Silicon 1 1 0 1
Na Sodium 0 2 2 0
K Potassium 1 0 1 0
Mo Molybdenum 55 54 58 54
Ni Nickel 0 0 0
Ag Silver 0 0 0 0
Ti Titanium 2 0 0
V Vanadium 0 0 0
Cd Cadmium 0 0 0
Ca Calcium 953 968 1096 1102
P Phosphorus 982 1015 1042 1055
Zn Zinc 1149 1163 1216 1246
Mg Magnesium 829 840 861 875
Ba Barium 0 0 0
B Boron 2 6 2
PREVIOUS SAMPLE
UNKNOWN HOURS ON OIL. NORMAL READINGS. NO PROBLEMS PRESENTLY
ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT THE NORMAL
INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
18-Feb-21 07-Oct-20 20-Mar-20 20-May-19
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 14.3 13.6 13.7 13.8
INFRARED (UFM) ASTM E2412
ST Soot 9 18 13 10
OXI Oxidation 16 16 16 16
SUL Sulfur Products 21 22 21 21
NIT Nitration 8 8 8 8
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
FUEL
F Fuel N N N N
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
ENGINE
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-51053-0043
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
HYDRAULIC SYSTEM EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillMonitor Compartment
Interpreted On: 03-Nov-17
PARTICLE COUNT IS ELEVATED. MICROSCOPE PICTURE INCLUDED. OTHER READINGS APPEAR NORMAL. INSPECT
OIL FILTER(S) FOR ANY EVIDENCE OF LARGER VISIBLE DEBRIS TRAPPED IN THE FILTER ELEMENT(S). RESAMPLE
IN 250 HOURS TO MONITOR. INTERPRETATION BY MARY C. - LAB MANAGER
E330-47306-0001
LABEL#: 0001
SAMPLE SHIP TIME (days) : 20
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 02-Nov-17
SAMPLE INFORMATION
13-Oct-17
E330-47306-0001
02-Nov-17
2500
2500
2500
CAT
0W-20
N
N
U
22-Mar-17
E330-47089-0001
30-Mar-17
2000
2000
2000
CAT
0W-20
N
Y
U
16-Aug-16
E330-46239-0002
26-Aug-16
1500
1500
CAT
0W-20
N
Y
U
01-Mar-16
E330-46063-0001
03-Mar-16
1000
1000
CAT
0W-20
N
Y
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
Comp Meter [Hr]
WEAR LEVELS / ADDITIVES
13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 4 3 3 3
Fe Iron 5 4 3 4
Cr Chromium 0 0 0 0
Al Aluminum 3 1 1 2
Pb Lead 0 0 1 1
Sn Tin 0 0 0 0
Si Silicon 5 4 2 4
Na Sodium 6 5 4 5
K Potassium 4 3 3 3
Mo Molybdenum 0 0 0 0
Ag Silver 1 0 0 1
Ca Calcium 2575 2678 2865 2703
P Phosphorus 941 956 998 937
Zn Zinc 1126 1139 1223 1141
Mg Magnesium 11 12 10 17
PREVIOUS SAMPLE
PARTICLE COUNT APPEARS ELEVATED. OTHER READINGS APPEAR NORMAL.
RESAMPLE AT THE NEXT SERVICE INTERVAL. INTERPRETATION BY RACHEL S
. - FLUIDS TECH
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 8.0 7.3 7.4 7.7
INFRARED (UFM) ASTM E2412
ST Soot 0 0 0 0
OXI Oxidation 43 39 41 38
SUL Sulfur Products 50 48 48 47
NIT Nitration 5 5 6 5
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
CLEANLINESS13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 22/21/18 20/19/16 18/16/13 19/15/13
4µ 4µ 37439 7228 1364 2813
6µ 6µ 13707 2822 398 315
10µ 10µ 3311 1081 129 104
14µ 14µ 1479 575 62 52
18µ 18µ 793 297 30 25
21µ 21µ 551 189 20 15
38µ 38µ 101 36 4 4
50µ 50µ 34 14 2 2
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
HYDRAULIC SYSTEM
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-47306-0001
Monitor Compartment
E330-47306-0001
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
HYDRAULIC SYSTEM EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 16-Oct-20
UNKNOWN HOURS ON OIL. NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS SAMPLE.
CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-50290-0002
LABEL#: 0002
SAMPLE SHIP TIME (days) : 9
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 16-Oct-20
SAMPLE INFORMATION
07-Oct-20
E330-50290-0002
16-Oct-20
4500
CAT
0W-20
N
Y
U
22-May-19
E330-49154-0001
03-Jun-19
4000
2000
CAT
0W-20
U
U
U
26-Oct-18
E330-48319-0001
15-Nov-18
3500
3500
500
CAT
0W-20
N
Y
U
20-Apr-18
E330-48113-0008
23-Apr-18
3000
3000
3000
CAT
0W-20
N
Y
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
Comp Meter [Hr]
WEAR LEVELS / ADDITIVES
07-Oct-20 22-May-19 26-Oct-18 20-Apr-18
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 4 3 4 6
Fe Iron 6 5 5 6
Cr Chromium 0 0 0 0
Al Aluminum 2 1 2 2
Pb Lead 1 1 1 1
Sn Tin 0 0 0 0
Si Silicon 4 4 4 5
Na Sodium 6 6 6 6
K Potassium 3 2 3 2
Mo Molybdenum 2 0 0 0
Ni Nickel 0
Ag Silver 0 0 0 0
Ti Titanium 0
V Vanadium 0
Cd Cadmium 0
Ca Calcium 2327 2332 2388 2882
P Phosphorus 936 914 922 1045
Zn Zinc 1138 1131 1108 1242
Mg Magnesium 27 15 10 10
Ba Barium 0
B Boron 1
PREVIOUS SAMPLE
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION
BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
07-Oct-20 22-May-19 26-Oct-18 20-Apr-18
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 7.6 7.5 7.4 7.6
INFRARED (UFM) ASTM E2412
ST Soot 0 0 0 0
OXI Oxidation 46 42 42 43
SUL Sulfur Products 53 50 50 50
NIT Nitration 6 5 5 5
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
CLEANLINESS07-Oct-20 22-May-19 26-Oct-18 20-Apr-18
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 19/17/14 19/17/14 19/16/12 22/18/14
4µ 4µ 4350 2698 3367 27292
6µ 6µ 1044 772 401 2003
10µ 10µ 260 196 62 289
14µ 14µ 114 122 25 142
18µ 18µ 52 66 13 85
21µ 21µ 38 52 7 64
38µ 38µ 12 4 2 13
50µ 50µ 4 2 1 7
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
HYDRAULIC SYSTEM
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-50290-0002
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
RADIATOR EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Rachel SmithMonitor Compartment
Interpreted On: 07-Mar-16
SAMPLE HAS AN AMMONIA ODOR. OTHER READINGS APPEAR NORMAL. CONTINUE TO USE THIS COOLANT.
SAMPLE AGAIN AT THE REGULAR INTERVAL TO MONITOR THE COOLING SYSTEM. INTERPRETATION BY RACHEL
S. - FLUIDS TECH
E330-46064-4010
LABEL#: 4010
SAMPLE SHIP TIME (days) : 3
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 04-Mar-16
SAMPLE INFORMATION
01-Mar-16
E330-46064-4010
04-Mar-16
1000
CAT
N
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Fluid Weight
Fluid Type
Fluid Change
Filter Change
CORROSION LEVELS/ CHEMISTRY
01-Mar-16
NITRITE (ppm)
NO2 Nitrite 275
PREVIOUS SAMPLE
my.cat.comFor additional sample history, go to:
ADDITIONAL CHARACTERISTICS
01-Mar-16
REFRACTIVE INDEX
GL Glycol (%) 52
FP Freeze Point (°C) -41
BP Boil Point (°C) 108
pH ASTM D1287
pH pH 9.5
CONDUCTIVITY (μS/cm)
CON Conductivity 4485
PHYSICAL CHARACTERISTICS01-Mar-16
PHYSICAL
Color Color red/light
App Appearance clear
Odor Odor ammonia
Oil Oil none
Foam Foam norm
PAmt Precip Amount none
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Coolant Analysis Report
RADIATOR
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-46064-4010
Monitor Compartment
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Coolant Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
RADIATOR EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Rachel SmithNo Action Required
Interpreted On: 08-Nov-17
ALL LEVEL 1 TESTS APPEAR NORMAL FOR ELC. CONTINUE TO USE THIS COOLANT. SAMPLE AGAIN AT THE
REGULAR INTERVAL TO MONITOR THE COOLING SYSTEM. INTERPRETATION BY RACHEL S. - FLUIDS TECH
E330-47310-4007
LABEL#: 4007
SAMPLE SHIP TIME (days) : 24
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 06-Nov-17
SAMPLE INFORMATION
13-Oct-17
E330-47310-4007
06-Nov-17
2500
2500
CATELC
N
22-Mar-17
E330-47089-4004
30-Mar-17
2000
2000
CATELC
N
20-Oct-16
E330-46300-4009
26-Oct-16
1650
1650
150
CATELC
N
16-Aug-16
E330-46238-4002
25-Aug-16
1500
1500
CATELC
N
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Fluid Weight
Fluid Type
Fluid Change
Filter Change
Comp Meter [Hr]
CORROSION LEVELS/ CHEMISTRY
13-Oct-17 22-Mar-17 20-Oct-16 16-Aug-16
NITRITE (ppm)
NO2 Nitrite 680 626 221
ANION ANALYSIS (PPM) ASTM D4327
NO2 Nitrite 512
PREVIOUS SAMPLE
ALL LEVEL 1 TESTS APPEAR NORMAL FOR ELC. CONTINUE TO USE THIS
COOLANT. SAMPLE AGAIN AT THE REGULAR INTERVAL TO MONITOR THE
COOLING SYSTEM. INTERPRETATION BY RACHEL S. - FLUIDS TECH
my.cat.comFor additional sample history, go to:
ADDITIONAL CHARACTERISTICS
13-Oct-17 22-Mar-17 20-Oct-16 16-Aug-16
REFRACTIVE INDEX
GL Glycol (%) 50 51 50 52
FP Freeze Point (°C) -37 -38 -37 -41
BP Boil Point (°C) 107 107 107 108
pH ASTM D1287
pH pH 8.2 8.5 8.4 9.8
CONDUCTIVITY (μS/cm)
CON Conductivity 3465 4414 3476 4316
PHYSICAL CHARACTERISTICS13-Oct-17 22-Mar-17 20-Oct-16 16-Aug-16
PHYSICAL
Color Color red red red red/light
App Appearance clear clear clear clear
Odor Odor norm norm norm ammonia
Oil Oil none none none none
Foam Foam norm norm norm norm
PAmt Precip Amount none none none none
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Coolant Analysis Report
RADIATOR
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-47310-4007
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Coolant Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
RADIATOR EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Rachel SmithNo Action Required
Interpreted On: 04-Nov-20
ALL LEVEL 1 TESTS APPEAR NORMAL FOR ELC. CONTINUE TO USE THIS COOLANT. SAMPLE AGAIN AT THE
REGULAR INTERVAL TO MONITOR THE COOLING SYSTEM. INTERPRETATION BY RACHEL S. - FLUIDS TECH
E330-50295-4007
LABEL#: 4007
SAMPLE SHIP TIME (days) : 14
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 21-Oct-20
SAMPLE INFORMATION
07-Oct-20
E330-50295-4007
21-Oct-20
4500
CATELC
N
N
20-May-19
E330-49151-4005
31-May-19
4000
1500
CATELC
N
26-Oct-18
E330-48318-4003
14-Nov-18
3500
3500
CATELC
N
20-Apr-18
E330-48115-4003
25-Apr-18
3000
3000
1469
CATELC
N
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Fluid Weight
Fluid Type
Fluid Change
Filter Change
Comp Meter [Hr]
CORROSION LEVELS/ CHEMISTRY
07-Oct-20 20-May-19 26-Oct-18 20-Apr-18
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Na Sodium 5053 4200 3640
K Potassium 29 62 5
Mo Molybdenum 815 680 608
Cu Copper 0 0 0
Fe Iron 0 0 0
Pb Lead 0 0 0
Sn Tin 0 1 1
Al Aluminum 0 0 0
Zn Zinc 0 0 0
NITRITE (ppm)
NO2 Nitrite 545 518 491 572
ADDITIONAL ANALYTES (PPM)
MoO4 Molybdate 1358 1134 1014
BO3 Borate 6 5 0
SiO3 Silicate 19 51 41
PREVIOUS SAMPLE
ALL LEVEL 1 TESTS APPEAR NORMAL FOR ELC. CONTINUE TO USE THIS
COOLANT. SAMPLE AGAIN AT THE REGULAR INTERVAL TO MONITOR THE
COOLING SYSTEM. INTERPRETATION BY RACHEL S. - FLUIDS TECH
my.cat.comFor additional sample history, go to:
ADDITIONAL CHARACTERISTICS
07-Oct-20 20-May-19 26-Oct-18 20-Apr-18
ADDITIONAL ANALYTES (PPM)
PO4 Phosphate 1 52 6
TH Total Hardness 12 9 9
REFRACTIVE INDEX
GL Glycol (%) 50 50 50 50
FP Freeze Point (°C) -37 -37 -37 -37
BP Boil Point (°C) 107 107 107 107
pH ASTM D1287
pH pH 7.9 8.0 8.0 8.3
CONDUCTIVITY (μS/cm)
CON Conductivity 3553 3663 3740 3586
PHYSICAL CHARACTERISTICS07-Oct-20 20-May-19 26-Oct-18 20-Apr-18
PHYSICAL
Color Color orange red red red
App Appearance clear clear clear clear
Odor Odor norm norm norm norm
Oil Oil none none none none
Foam Foam norm norm norm norm
PAmt Precip Amount none none trace none
PApp Precip Appearance granular
PCol Precip Color blk sol
PProp Precip Property mag
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Coolant Analysis Report
RADIATOR
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-50295-4007
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Coolant Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TANDEM LEFT EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 03-Nov-17
PARTICLE COUNT IS ELEVATED. OTHER ANALYSIS READINGS APPEAR TO BE ACCEPTABLE. RESAMPLE AT THE
NEXT SERVICE INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-47306-0122
LABEL#: 0122
SAMPLE SHIP TIME (days) : 20
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 02-Nov-17
SAMPLE INFORMATION
13-Oct-17
E330-47306-0122
02-Nov-17
2500
2500
500
CAT
30
N
N
U
22-Mar-17
E330-47089-0088
30-Mar-17
2000
2000
2000
CAT
30
Y
0
U
16-Aug-16
E330-46239-0099
26-Aug-16
1500
1500
CAT
30
N
N
U
01-Mar-16
E330-46063-0135
03-Mar-16
1000
1000
CAT
N
N
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 0 4 3 3
Fe Iron 55 200 167 196
Cr Chromium 0 0 0 0
Al Aluminum 1 1 1 3
Pb Lead 0 0 1 0
Sn Tin 0 0 0 0
Si Silicon 3 4 2 5
Na Sodium 1 2 1 3
K Potassium 1 1 1 1
Mo Molybdenum 3 2 2 1
Ag Silver 0 0 0 0
Ca Calcium 3093 2480 2864 2765
P Phosphorus 893 895 1001 965
Zn Zinc 1049 1025 1155 1124
Mg Magnesium 32 9 8 8
PREVIOUS SAMPLE
NORMAL WEAR METAL READINGS. OTHER ANALYSIS READINGS APPEAR TO
BE ACCEPTABLE. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION
BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 11.5 10.4 10.4 10.9
WATER
W Water N N N N
CLEANLINESS13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 23/22/19 23/22/17 LOW OIL VOLUM 23/23/21
4µ 4µ 54514 48789 58382
6µ 6µ 39559 40000 48517
10µ 10µ 14277 17271 30764
14µ 14µ 4213 1267 16395
18µ 18µ 1266 86 5040
21µ 21µ 536 24 1208
38µ 38µ 35 6 8
50µ 50µ 18 4 2
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TANDEM LEFT
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-47306-0122
No Action Required
E330-47306-0122
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TANDEM LEFT EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 16-Oct-20
UNKNOWN HOURS ON OIL. PARTICLE COUNT IS SLIGHTLY ELEVATED. OTHER ANALYSIS READINGS APPEAR TO
BE ACCEPTABLE. RESAMPLE AT THE NEXT SERVICE INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-50290-0078
LABEL#: 0078
SAMPLE SHIP TIME (days) : 9
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 16-Oct-20
SAMPLE INFORMATION
07-Oct-20
E330-50290-0078
16-Oct-20
4500
500
CENEX
30
N
0
U
20-May-19
E330-49155-0043
04-Jun-19
4000
2000
CENEX
30
N
0
U
26-Oct-18
E330-48319-0093
15-Nov-18
3500
3500
500
CAT
30
N
N
U
20-Apr-18
E330-48113-0164
23-Apr-18
3000
3000
1000
CAT
30
N
0
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
07-Oct-20 20-May-19 26-Oct-18 20-Apr-18
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 0 0 1 0
Fe Iron 53 101 126 62
Cr Chromium 0 0 0 0
Al Aluminum 1 1 1 1
Pb Lead 0 0 0 0
Sn Tin 0 0 0 0
Si Silicon 3 4 4 4
Na Sodium 2 2 2 2
K Potassium 0 0 1 1
Mo Molybdenum 9 0 1 1
Ni Nickel 0
Ag Silver 0 0 0 0
Ti Titanium 0
V Vanadium 0
Cd Cadmium 0
Ca Calcium 2539 3037 3346 2187
P Phosphorus 987 917 996 676
Zn Zinc 1206 1056 1117 770
Mg Magnesium 147 10 18 7
Ba Barium 0
B Boron 5
PREVIOUS SAMPLE
PARTICLE COUNT IS ELEVATED. OTHER ANALYSIS READINGS APPEAR TO BE
ACCEPTABLE. RESAMPLE AT THE NEXT SERVICE INTERVAL.
INTERPRETATION BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
07-Oct-20 20-May-19 26-Oct-18 20-Apr-18
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 11.4 11.4 10.9 11.4
WATER
W Water N N N N
CLEANLINESS07-Oct-20 20-May-19 26-Oct-18 20-Apr-18
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 25/24/18 25/24/19 23/23/20
4µ 4µ 206414 226192 64259
6µ 6µ 85682 117032 53076
10µ 10µ 8266 13932 27435
14µ 14µ 1900 2550 9677
18µ 18µ 450 530 2638
21µ 21µ 286 308 1059
38µ 38µ 4 8 84
50µ 50µ 0 6 44
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TANDEM LEFT
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-50290-0078
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TANDEM RIGHT EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 03-Mar-16
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT
THE NORMAL INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-46063-0136
LABEL#: 0136
SAMPLE SHIP TIME (days) : 2
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 03-Mar-16
SAMPLE INFORMATION
01-Mar-16
E330-46063-0136
03-Mar-16
1000
1000
FACTORYFIL
30
N
N
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
WEAR LEVELS / ADDITIVES
01-Mar-16
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 2
Fe Iron 178
Cr Chromium 0
Al Aluminum 1
Pb Lead 1
Sn Tin 0
Si Silicon 5
Na Sodium 3
K Potassium 2
Mo Molybdenum 2
Ag Silver 0
Ca Calcium 2760
P Phosphorus 956
Zn Zinc 1119
Mg Magnesium 8
PREVIOUS SAMPLE
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
01-Mar-16
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 10.7
WATER
W Water N
CLEANLINESS01-Mar-16
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 23/23/21
4µ 4µ 57718
6µ 6µ 47444
10µ 10µ 29261
14µ 14µ 14948
18µ 18µ 4250
21µ 21µ 898
38µ 38µ 5
50µ 50µ 2
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TANDEM RIGHT
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-46063-0136
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TANDEM RIGHT EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillMonitor Compartment
Interpreted On: 23-Apr-18
PARTICLE COUNT IS ELEVATED. MICROSCOPE PICTURE INCLUDED. OTHER ANALYSIS READINGS APPEAR TO BE
ACCEPTABLE. RESAMPLE IN 250 HOURS TO MONITOR. INTERPRETATION BY MARY C. - LAB MANAGER
E330-48113-0166
LABEL#: 0166
SAMPLE SHIP TIME (days) : 3
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 23-Apr-18
SAMPLE INFORMATION
20-Apr-18
E330-48113-0166
23-Apr-18
3000
3000
1000
CAT
30
U
0
U
13-Oct-17
E330-47306-0123
02-Nov-17
2500
2500
500
CAT
30
N
N
U
22-Mar-17
E330-47089-0108
30-Mar-17
2000
2000
2000
CAT
30
Y
0
U
16-Aug-16
E330-46239-0100
26-Aug-16
1500
1500
CAT
30
N
N
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
20-Apr-18 13-Oct-17 22-Mar-17 16-Aug-16
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 3 0 2 2
Fe Iron 76 58 212 166
Cr Chromium 0 0 1 0
Al Aluminum 2 1 1 1
Pb Lead 0 1 1 1
Sn Tin 0 0 0 0
Si Silicon 3 3 5 1
Na Sodium 2 0 3 0
K Potassium 1 0 1 1
Mo Molybdenum 1 1 1 0
Ag Silver 0 0 0 0
Ca Calcium 2216 3467 2677 2808
P Phosphorus 707 955 950 974
Zn Zinc 787 1143 1088 1147
Mg Magnesium 7 17 13 8
PREVIOUS SAMPLE
PARTICLE COUNT IS ELEVATED. OTHER ANALYSIS READINGS APPEAR TO BE
ACCEPTABLE. RESAMPLE AT THE NEXT SERVICE INTERVAL.
INTERPRETATION BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
20-Apr-18 13-Oct-17 22-Mar-17 16-Aug-16
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 11.3 11.4 10.5 10.4
WATER
W Water N N N N
CLEANLINESS20-Apr-18 13-Oct-17 22-Mar-17 16-Aug-16
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 23/23/21 23/23/20 23/23/19 LOW OIL VOLUM
4µ 4µ 64278 58516 47526
6µ 6µ 55768 44194 40833
10µ 10µ 35217 16825 23153
14µ 14µ 17354 5117 4448
18µ 18µ 6390 1584 608
21µ 21µ 2545 698 157
38µ 38µ 41 65 1
50µ 50µ 7 40 0
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TANDEM RIGHT
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-48113-0166
Monitor Compartment
E330-48113-0166
E330-47306-0123
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TANDEM RIGHT EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 03-Mar-21
PARTICLE COUNT IS ELEVATED. NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-51062-0084
LABEL#: 0084
SAMPLE SHIP TIME (days) : 2
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 03-Mar-21
SAMPLE INFORMATION
01-Mar-21
E330-51062-0084
03-Mar-21
4750
4750
750
CENEX
15W-40
N
N
U
07-Oct-20
E330-50290-0079
16-Oct-20
4500
CAT
30
N
0
U
20-May-19
E330-49155-0044
04-Jun-19
4000
2000
CAT
30
Y
U
26-Oct-18
E330-48319-0094
15-Nov-18
3500
3500
1500
CAT
30
N
N
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
01-Mar-21 07-Oct-20 20-May-19 26-Oct-18
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 0 0 1 1
Fe Iron 83 110 107 135
Cr Chromium 0 0 0 0
Al Aluminum 1 1 1 2
Pb Lead 0 0 0 0
Sn Tin 0 1 0 0
Si Silicon 2 3 5 5
Na Sodium 0 2 3 2
K Potassium 0 0 1 1
Mo Molybdenum 9 10 0 0
Ni Nickel 0 0
Ag Silver 0 0 0 0
Ti Titanium 0 0
V Vanadium 0 0
Cd Cadmium 0 0
Ca Calcium 2215 2573 3349 3466
P Phosphorus 818 981 1018 1014
Zn Zinc 1049 1212 1149 1139
Mg Magnesium 129 147 10 14
Ba Barium 0 0
B Boron 2 3
PREVIOUS SAMPLE
UNKNOWN HOURS ON OIL. PARTICLE COUNT IS ELEVATED. MICROSCOPE
PICTURE INCLUDED. IRON REMAINS SLIGHTLY ELEVATED FROM TREND.
INSPECT ANY MAGNETIC PLUG(S) FOR FERROUS METAL & CHECK OIL FOR
OTHER VISIBLE MATERIAL/ METAL. RESAMPLE IN 250 HOURS TO MONITOR.
INTERPRETATION BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
01-Mar-21 07-Oct-20 20-May-19 26-Oct-18
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 11.6 11.3 11.3 11.0
WATER
W Water N N N N
CLEANLINESS01-Mar-21 07-Oct-20 20-May-19 26-Oct-18
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 25/25/20 25/24/21 25/24/19
4µ 4µ 229816 230182 221052
6µ 6µ 162600 151406 110984
10µ 10µ 43328 42834 14614
14µ 14µ 6980 13500 3118
18µ 18µ 1200 3668 658
21µ 21µ 304 2286 416
38µ 38µ 4 20 6
50µ 50µ 2 4 4
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TANDEM RIGHT
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-51062-0084
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TRANSMISSION DIFF EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 02-Nov-17
PARTICLE COUNT IS ELEVATED. OTHER ANALYSIS READINGS APPEAR TO BE ACCEPTABLE. RESAMPLE AT THE
NEXT SERVICE INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-47306-0022
LABEL#: 0022
SAMPLE SHIP TIME (days) : 20
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 02-Nov-17
SAMPLE INFORMATION
13-Oct-17
E330-47306-0022
02-Nov-17
2500
2500
500
CAT
30
N
N
U
22-Mar-17
E330-47089-0016
30-Mar-17
2000
2000
1000
CAT
30
Y
Y
U
16-Aug-16
E330-46239-0018
26-Aug-16
1500
500
CAT
30
N
Y
U
01-Mar-16
E330-46063-0031
03-Mar-16
1000
1000
CAT
30
N
Y
U
Sampled Date
Sample Id
Lab Date
Meter [Hr]
Meter On Fluid
Fluid Brand
Kidney Loop
Fluid Weight
Fluid Type
Fluid Change
Filter Change
Comp Meter [Hr]
WEAR LEVELS / ADDITIVES
13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 11 54 39 145
Fe Iron 7 19 15 58
Cr Chromium 0 0 0 0
Al Aluminum 3 4 3 6
Pb Lead 4 0 0 2
Sn Tin 0 0 0 0
Si Silicon 3 3 0 3
Na Sodium 1 3 2 13
K Potassium 0 1 1 7
Mo Molybdenum 2 0 0 0
Ag Silver 0 0 0 0
Ca Calcium 2901 2370 2815 2675
P Phosphorus 943 922 1014 943
Zn Zinc 1187 1022 1172 1108
Mg Magnesium 29 8 10 8
PREVIOUS SAMPLE
COPPER APPEARS SLIGHTLY ELEVATED. PARTICLE COUNT APPEARS
ELEVATED. OTHER READINGS APPEAR NORMAL. RESAMPLE AT THE NEXT
SERVICE INTERVAL. INTERPRETATION BY RACHEL S. - FLUIDS TECH
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 11.0 10.6 10.6 9.8
INFRARED (UFM) ASTM E2412
ST Soot 0 0 0 0
OXI Oxidation 4 5 7 6
SUL Sulfur Products 19 19 19 19
NIT Nitration 5 5 6 5
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
CLEANLINESS13-Oct-17 22-Mar-17 16-Aug-16 01-Mar-16
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 22/18/15 23/21/18 18/16/14 20/18/15
4µ 4µ 22177 55262 1668 6622
6µ 6µ 1549 15530 517 1495
10µ 10µ 438 4176 222 482
14µ 14µ 278 1718 129 229
18µ 18µ 204 769 72 103
21µ 21µ 169 479 44 57
38µ 38µ 65 90 6 12
50µ 50µ 48 39 1 8
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TRANSMISSION DIFF
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-47306-0022
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report
Web: [email protected] Email: [email protected]
Phone: nmc-technologies.com / 844-NMC-TECH
NMC - Fluid Analysis Report 14648 Shepard St, Suite 500 Omaha, NE 68138 USA
TRANSMISSION DIFF EQUIP NUM: 8 SERIAL NUMBER: R9M00419
CAT 140M2
Interp By: Mary E ChurchillNo Action Required
Interpreted On: 16-Oct-20
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS SAMPLE. CONTINUE SAMPLING AT
THE NORMAL INTERVAL. INTERPRETATION BY MARY C. - LAB MANAGER
E330-50290-0020
LABEL#: 0020
SAMPLE SHIP TIME (days) : 9
BURT COUNTY ROAD
DEPARTMENT
RECEIVED DATE: 16-Oct-20
SAMPLE INFORMATION
07-Oct-20
E330-50290-0020
16-Oct-20
4500
500
CAT
30
N
Y
U
22-May-19
E330-49154-0025
03-Jun-19
4000
1000
CENEX
30
Y
Y
0
U
26-Oct-18
E330-48319-0022
15-Nov-18
3500
3500
500
CAT
30
N
Y
0
U
20-Apr-18
E330-48113-0041
23-Apr-18
3000
3000
1000
CAT
30
Y
Y
U
Sampled Date
Kidney Loop
Make Up Fluid []
Filter Change
Fluid Change
Fluid Type
Fluid Weight
Fluid Brand
Meter On Fluid
Comp Meter [Hr]
Meter [Hr]
Lab Date
Sample Id
WEAR LEVELS / ADDITIVES
07-Oct-20 22-May-19 26-Oct-18 20-Apr-18
ELEMENTAL ANALYSIS (PPM) ASTM D5185 [OIL] / ASTM D6130 [COOLANT]
Cu Copper 32 10 11 15
Fe Iron 8 6 5 8
Cr Chromium 0 0 0 0
Al Aluminum 4 3 3 4
Pb Lead 0 0 0 0
Sn Tin 0 0 0 0
Si Silicon 2 2 2 3
Na Sodium 3 3 3 4
K Potassium 0 1 1 1
Mo Molybdenum 8 1 2 0
Ni Nickel 0
Ag Silver 0 0 0 0
Ti Titanium 0
V Vanadium 0
Cd Cadmium 0
Ca Calcium 2520 2952 2824 2687
P Phosphorus 952 1011 985 929
Zn Zinc 1178 1275 1204 1141
Mg Magnesium 127 33 29 8
Ba Barium 0
B Boron 2
PREVIOUS SAMPLE
NORMAL READINGS. NO PROBLEMS PRESENTLY ASSOCIATED WITH THIS
SAMPLE. CONTINUE SAMPLING AT THE NORMAL INTERVAL. INTERPRETATION
BY MARY C. - LAB MANAGER
my.cat.comFor additional sample history, go to:
CONDITION / CONTAMINATION
07-Oct-20 22-May-19 26-Oct-18 20-Apr-18
VISCOSITY (CENTISTOKES) ASTM D445
V100 Viscosity at 100 C 11.0 11.0 10.9 10.8
INFRARED (UFM) ASTM E2412
ST Soot 0 0 0 0
OXI Oxidation 7 5 5 4
SUL Sulfur Products 20 19 18 19
NIT Nitration 5 5 5 5
WATER
W Water N N N N
ANTIFREEZE
A Antifreeze N N N N
CLEANLINESS07-Oct-20 22-May-19 26-Oct-18 20-Apr-18
PARTICLE COUNT - ISO 11171:1999 reported per ISO 4406
ISO ISO Code Rating 21/18/14 21/18/13 22/19/16 22/19/14
4µ 4µ 10978 10894 32647 38908
6µ 6µ 1992 1534 3919 4705
10µ 10µ 280 108 971 302
14µ 14µ 88 54 460 131
18µ 18µ 28 38 231 70
21µ 21µ 20 36 137 47
38µ 38µ 2 18 16 6
50µ 50µ 0 6 6 2
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 1 of 2Oil Analysis Report
TRANSMISSION DIFF
SERIAL NUMBER: R9M00419
EQUIP NUM: 8
CAT 140M2
E330-50290-0020
No Action Required
Our sample reports has been updated! For more information on the new report, go to - https://www.youtube.com/watch?v=4h8bREJVUrs
Report Comment
111 NORTH 13th ST
TEKAMAH, NE 68061-1082
CECIL BRUMMOND
BURT COUNTY ROAD DEPT.
USA
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component thereof.
Page 2 of 2Oil Analysis Report