37
Product Manual

MT069.31.237 REV 03 - digicon.com.br · 06 2. Orientations Ÿ Read the information and instructions of this manual carefully, before using the product. This ensures the correct use

  • Upload
    vothuy

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

Product Manual

Copyright– Digicon S.A.

Controle Eletrônico para Mecânica – 2014

All rights reserved. No part of this publication may be reproduced, transmitted,transcribed, stored in a retrieval system, translated into any language or computerlanguage in any electronic, magnetic, optical, chemical, manual way, or otherwise,without the express written permission from Digicon S.A.

Manual code: 069.31.237English - Revision: 03

This manual was elaborated by: Digicon S.A. Controle Eletrônico para Mecânica

Documentation Sector - EDS

Contents050606070910101111121414141516171718181919202324242425252626262829303131323335

1. Important instructions ..........................................................................2. Orientations ........................................................................................3. Introduction ........................................................................................4. Features of Catrax Automatic Plus ..........................................................4.1. Catrax Automatic Plus operation ..........................................................5. Installing/Assembling Catrax Automatic Plus ............................................5.1. Unboxing .........................................................................................5.2. floor drilling ......................................................................................5.3. Column fixation .................................................................................5.4. Assembling the arms .........................................................................5.5. Access to Catrax Automatic Plus after assembly ......................................5.5.1. Rear cover .....................................................................................5.5.2. Front cover ....................................................................................5.5.3. Column cover .................................................................................5.6. Connection to power network ..............................................................6. Installing/assembling optional items .......................................................6.1. Collecting box kit ...............................................................................6.1.1. Connection of collecting box kit to control board ...................................6.2. Pictogram Kit ....................................................................................6.3. Power supply ....................................................................................6.4. Electromechanical counter kit ..............................................................6.5. Control board ....................................................................................6.5.1. Inputs ...........................................................................................6.5.2. Outputs .........................................................................................6.5.2.1 Return signal ................................................................................6.5.2.2 Electromagnets .............................................................................6.5.2.3. Sound alarm ................................................................................6.5.2.4. Connection scheme......................................................................6.5.2.5. Pictogram ...................................................................................6.5.2.6. Pictogram's connections ................................................................6.5.3. Configuration of control board ..........................................................6.6. Anti-panic system ..............................................................................6.6.1. Assembling the arms .......................................................................6.6.2. Maintenance test ............................................................................7. Maintenance ........................................................................................7.1. Preventive and corrective routine maintenance ......................................7.2. Defects and possible causes ................................................................8. Technical characteristics ........................................................................9. Warranty and technical assistance ..........................................................

05

1. mportant nstructionsI i

You can see, below, the symbols that will appear in this manual,signaling important moments. It is essential to pay attention to them.

TIP: Indicates something Digicon considers important.

CAUTION: Indicates a moment of extreme caution whenhandling the equipment/product

ATTENTION: Indicates a moment when your observationskills should be extremely productive.

INFORMATION: Presents interesting facts about thepurchased product.

QR CODE: Presents additional information or linkswith more details about the presented text.

06

2. Orientations

� Read the information and instructions of this manual carefully, before using theproduct. This ensures the correct use of the equipment and maximum use of itstechnical features as well as a prolonged service life.

� This product does not present sealing against the rain, that is, it is designed to beused indoors.

� Keep this manual for future consultations.� Digicon reserves its right to alter its products at any moment to adapt them to more

recent technical advancements.� Digicon maintains its right to alter the information contained in this manual without

previous notice.� Digicon does not provide any contractual warranty concerning the information in

this manual, and cannot be held responsible for errors it may contain and problemsdue to its use.

� The information contained in this manual is exclusive property of Digicon and isprotected by copyright laws.

� This manual cannot be reproduced, photocopied or translated, in its entirety or inpart, into any kind of medium, without Digicon's written consent.

3. IntroductionFollowing a new technological concept focused on solidity and reliability and countingwith innovative design elements, with variety of colors, lines, and curves, Digicon haslaunched the line CATRAX Automatic Plus.CATRAX Automatic Plus serves most technologies of access control currently available,becoming the best option in the market for access control.This manual presents a detailed description of the components and working of CATRAXAutomatic Plus.To see our complete catalogue, visit www.digicon.com.br.

07

Lock

Open (key)

Raise the coverPull

4. Features of Automatic MasterCATRAX Automatic Plus, an access controller in the model mini turnstile (columntype), presents three bidirectional, equidistant arms at 120 degrees with brushedstainless steel (AISI 304) finishing.

The column can present external finishing in brushed stainless steel (AISI 304) or1020 carbon steel with electrostatic painting in black epoxy powder. It has reinforcedstructure, fully rounded corners, and non-exposed screws, offering space and comfortfor any access control solution.Aiming at facilitating assembly and maintenance, the column CATRAX Automatic Pluspresents a U-shaped internal support (mounting rack) with standard holes for thefixation of additional electronic boards. Moreover, the clients, according to their needs,can add additional holes. Access to the mounting rack is done through a key withsecret, whose removal and insertion are extremely easy.

08

A plastic cover and a stainless steel sheet compose the upper panel. The cover, madeof injected plastic, can be purchased in the colors black, green, or burgundy; or in anyother color desired, on demand.The upper cover in stainless steel allows easy configuration and low-costcustomization of the product. The sheet can also present slots for optional items, suchas pictogram, collecting box input, display kit (separate manual), or a combination ofthese items. The following images show some of the options.

Besides compatibility with most available technologies, Digicon can provide thefollowing optional items: collecting kit with box, counter kit, power supply, MCAboard, and display kit

Contactless card reader Flat Card reader with slotfor barcode

TIP: To see details about the components' dimensions, see 8. Technicalcharacteristics.

09

4.1 Catrax Automatic Plus operation:

CATRAX Automatic Plus has bidirectional motorized turning with two 24 Vccelectromagnets for activating the locks.It also includes a microprocessor control board, where a signal enabling passage issent through one of the inputs, depending on the passage direction. If this signal isrecognized, the equipment will allow the turning of the arm of CATRAX Automatic Plus.After half of the turning is complete (60 degrees), a 400 milliseconds returning signalwill be sent, informing the passage direction. After the signal, the arm cannot bereturned to the previous position.Depending on the CATRAX Automatic Plus model and configuration, if the passage isforced without the enabling signal, an electromagnet will be activated to prevent turn.In addition, the equipment can emit a signal for a sound alarm and/or the exhibition ofa red X on the upper panel display (models with pictogram). In this case, a returnsignal will be sent, indicating that the turnstile was forced, informing the direction ofturn.The image below shows the operation mechanism of CATRAX Automatic Plus.

Mini arm

Arn-dropsolenoid(BQC)

Locks

Engine

Bidirectional arms:- From left right- From right to left

10

As the items inside the package can vary (depending on the client's requests), it isimportant to perform a cautious visual inspection before installing and assembling theturnstile. A checklist that works as a guide during inspection accompanies all Digiconpackages.

See below the parts that can compose CATRAX Automatic Plus:

ATTENTION: To avoid losses, the screws and the wrenches used forassembling the CATRAX Automatic Plus are attached to the box containingthe arms. Before discarding the packing materials (cardboard and plastics),make sure all the items in the checklist are accounted for.

Plastic cover kit

Arm

Lock to access the columnColumn door

Upper pictogramkit (optional)

Collecting boxkit (optional)Stainless steel

sheet (rear cover)

Stainless steelsheet (front cover)

Lock to accessthe column’s rack

Lock to access thecover for the pasage

of cables

5.Installing/Assembling Catrax AutomaticPlus

5.1. Unboxing

11

5.2 Floor drilling:

Before installing CATRAX Automatic Plus, check:

1. The place chosen for the installation.2. If there is a power source or electric socket nearby (ducts for connection).3. If the place chosen is adequate for the installation of the access controller (indoors).4. If there will be enough space (minimum 5 cm) between the rear of the CATRAXAutomatic Plus column and the wall. This space is important in order to provide accessto the upper panel and plug's locks for the cables passage.5. If there will be enough space for the arms after CATRAX Automatic Plus isassembled.6. If the floor is in conditions to receive anchor bolts (minimum of 4 cm of FCK15 M.P.A.concrete or equivalent).

5.3 Column fixation:

To fix the column to the floor, observe the following steps and the indicated images:

1. rill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make four externalDholes, according to the measures indicated in the image below:

INFORMATION: Besides the items mentioned above, CATRAX Automatic

Plus can be provided with counter kit and display kit.

12,5 (4x) (0,492")

210 (8,267")

170 (6,692")

78

(3,0

70

")3

6(1

,41

7")

Cables’ output

92

,5(3

,64

1")

32

(1,2

59

")

20(0,787")

Fixing perforation

51(2,007)

79,5(3,129")

16

0(6

,29

9")

ATTENTION: Since the CATRAX Automatic Plus's installation requiresfloor drilling, it is important that the location be chosen carefully.

12

5.4 Montagem dos braços e tampas:

I :NFORMATION

2. Clean the holes, removing any debris from drilling.3. Place the external part of the bolts in the holes. Leave about 25mm of the bolt out ofthe hole.

4. Position the column and fasten it to the floor with the four screws that accompanythe bolts. Use a flex-head socket wrench with ¾'' or an articulated socket wrench.

After drilling the floor and assembling the column, it is possible to assemble the armsand plastic covers.The image below shows the specific parts of CATRAX Automatic Plus's arms and upperfrontal cover with assembling instructions.

Arm

Screw M3x8

Flat washer M3

Screwa access cover

Allen M6x20 Screw

Spring washer M6

INFORMATION: n the central slot, destined to the passage of cables, it isInecessary to measure the cables according to the opening's size.

TIP: As an optional item, Digicon can provide a steel template for fixingCATRAX Automatic Plus, containing the exact demarcations of thenecessary holes.

TIP: We recommend the bolts by the brand Tecnart, model AF38110,3/8x4''

Screw M3x16

Upper cover plastic

- The cover for accessing the screws is fitted into place, so pressure it to

open or close it.

- To assemble the arms of CATRAX Automatic Plus, use an Allen n. 8

wrench.

13

Front Cover:

Rear cover:

Then, assemble the upper panel's rear cover. The image below shows the partscorresponding to each phase.

Frontal plasticcover set

Front stainlesssteel sheet

Collecting box’ssocket kit

Rear stainless steel cover

Pictogram's acrylic

Flat washer M3,spring washer M3and hex nut M3

14

5.5 Access to Catrax Automatic Plus after assembly:

After CATRAX Automatic Plus is installed and assembled, access to the interior of theequipment can be done with the key that accompanies the equipment, in three ways:

5.5.1 Rear cover

1º Open the lock with the smaller key (clockwise)2º Carefully raise the cover3º Brag the cover backwards

As shown below:

5.5.2 front cover

1º Unscrew the screws inside the turnstile that hold the cover2º Unscrew the screws out of the cover3º Pull the cover upwards

As shown below:

15

5.5.3 Column door

1º Open the lock with the smaller key (clockwise)2º Pull the cover forward3º The cover will be loose

As shown below:

16

CAUTION: Electric connections must be performed by qualified

professionals.

Groundwire

Input for datacables

TIP: We recommend that you use a good quality AC cable and ground wire

and with compatible dimensions to the distance until the switchboard. The

data cable must be type CAT5E. Manufacturers: FURUKAWA and AMP.

5.6 Connecting to power and data networks:

The Turnstile is powered by a 24 Vcc supply (located inside the turnstile). The owerpsupply can be of 100 to 240 Vca. Digicon recommends the regulation NBR 5410 asreference to the equipment's electrical connections.In one of its columns, the turnstile has circuit breakers in its columns where the powercables (electrical supply) and the ground wire must be connected.

Powernetwork

17

6.Installing/assembling optional temsiCATRAX Automatic Plus is compatible with most access control technologies in themarket today; however, Digicon offers a range of optional items that allow enhancingand matching the equipment's performance to the client's needs. See the descriptionof each of these items:

6.1 Collecting box kit

The collecting box kit has a device for collecting, retaining, and gathering cards orbadges. It is ideal for places with eventual visitors or users. The kit is composed of asocket, a retention device activated by a solenoid, and a storage box. The imagebelow shows the items that accompany the collecting box kit:

6.1.1 Connection of collecting kit to control board

6.2 Pictograma Kit

18

12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1

BOX SENSOR

ELECTROMAGNETS

TURNSTILE SENSORS

DIGICON CONTROL BOARDINPUTS CN8 OUTPUTS CN9

- S

OLE

NO

IDE

+ S

OLE

NO

IDE

SOLENOIDE

Your card reader (notincluded in the kit)

The pictogram kit visually signals the direction of passage (green arrows) or theblocking (red X).

To see the items that accompany the pictogram kit and details about its assembly, seethe product guide.

Sensor used forcollecting the card after1.5 seconds

For accesscontrol board

-The box for cards is part of the kit and is positioned under the collecting kit.

- The badge reader is not part of the kit

INFORMATION:

TIP:To obtain information on the configuration of the collecting kit, see item6.5 Control board.

19

PHASE:NEUTRALGROUND

GND24V / 3Acc

INPUT:100 TO240 VCA

SAÍDA

.

WIRE

6.3 Power Supply:

Among the main advantages of this optional item, is its adaptation capability tothe voltage variations often found in installation sites – the input voltage canvary between 100 and 240 Vca.The supply's specific technical features, protections and dimensions werecarefully tested and approved in hostile temperature and environmentalconditions, which ensures the adequate power supply to the equipment'sperformance. Besides the input and output voltages indicated in the imagebelow, the supply has a short-circuit and overheating protection.

6.4 Kit contador eletromecânico

Among the main advantages of this optional item, is its adaptation capability tothe voltage variations often found in installation sites – the input voltage canvary between 100 and 240 Vca.The supply's specific technical features, protections and dimensions werecarefully tested and approved in hostile temperature and environmentalconditions, which ensures the adequate power supply to the equipment'sperformance. Besides the input and output voltages indicated in the imagebelow, the supply has a short-circuit and overheating protection

Technical characteristics:Power supply: 24 VccNumber of digits: 06 (no return to zero)Digits size: 5 x 2 mm (height x width)

20

Con ector CN8n

Con ector CN9n

Ds01

Ds02

The table below describes the functions of the control board's connectors:

6.5 Control board:

CATRAX Automatic Plus's control board was designed to meet most technologies ofaccess control terminals in the market. The controller have mechanical features andlayout perfectly suited for the CATRAX Automatic Plus's needs and it is one of the bestoptions for the equipment's operation.The following images show the control board with its straps, connectors, anddipswitch, as well as the location of the power supply and the control board in CATRAXAutomatic Plus.

21

Si nalg N /Descriame ptionCN1

1

2

3

4

CN2 JTAG - Inner useCN3 SERIAL RS - 232

2 TX

3 RX

5 GND

CN4 ENGINE1 DAT +E

2 DAT -E

3 GND_485

4 (+) 24V_EXT

5 GND

CN5 POWER - POWER INPUT1 (+) 24Vcc

2 GND

3 (+) 24Vcc

CN6 TURNSTILE SENSORS1 Sensor 1 signal

2 LED 1 anode

3 sensor 2 signal

4 GND

5 LED 2 anode

CN7 AUDIO1 SI NALG

2 GND

CN8 INPUTS1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

BOX SENSORLED anode

Box signal

GND

GND

+Vext1 (enables turn through voltage)HAB1 (enables turn through dry contact - from right to left)GNDVext2 (enables turn through voltage)HAB2 (enables urn through dry contact - from left to right)GND+24Vcc (avalable to auxiliary - maximum 500mA)Vext3 (enables turn through voltage)BQC (activates anti-panic system)GNDOutput for yellow pictogramNCNO or NC contact (bob return)C Contact (bob return)NO or NC contact (BQC return)contact C (BQC return)

22

CN9 OUTPUTS1 NO or NC Contact (HAB1 return)

2 Contact C (HAB1 return)

3 NO or NC Contact (HAB2 return)

4 Contact C (HAB2 return)

5 Output for indicative X (open collector NPN – maximum 500 mA) orange wire

6 Output for arrow > (open collector NPN – maximum 500 mA) blue wire

7 Output for arrow < (open collector NPN – maximum 500 mA) green wire

8 +24Vcc (indicative arrows' power) red wire

9 GND (indicative arrows' power) black wire

10 + solenoid of badge collector box

11 - solenoid of badge collector box

12 Sound signal (open collector – NPN)

CN10 SOL BQC1 (+) 24Vca

2 SI NALG

CN14 BQC SENSOR1 (+) 24Vca

2 SI NALG

CN18 ELETROÍMÃS1 (+) ele 1ctromagnet

( ) ele 1- ctromagnet

( ) ele- ctromagnet 2

2

3 (+) ele 2ctromagnet

4

The following sections concern important aspects of CATRAX Automatic Plus's controlboard configuration and connections of CATRAX Automatic Plus.

INFORMATION:- The engine (CN4) and electromagnets (CN18) cables are providedalongside CATRAX Automatic Plus.

23

6.5.1 Inputs

The input signals or passage clearance (HAB1 and HAB2) or anti-panic (BQC) can beoriginated by a relay contact, pushbutton contact, tension from 5 to 24 Vca/cc, from110 to 220 Vca/cc. To enable passage through relay contact or pushbutton, make theconnection as shown below:

Enabling passage through tension pulse is shown in the image below. It is necessaryto observe the polarity of the CC voltages and to use an external resistor for highvoltages (110V and 220Vca).

Vcc

Vca ou VccVca ou Vcc

NO or NCcontact

24

6.5.2 Outputs

CATRAX Automatic Plus's board has outputs for return signals, electromagnets,pictogram, collecting box, and sound alarm.

6.5.2.1 Return signalsThe control board has 4 return signals, two to indicate the moment, one to bob theturnstile, and one to indicate the anti-panic system's status. All signals are originatedvia relay – normally open contact (NO) or normally closed contact (NC). Connect theoutputs according to the image below:

6.5.2.2 ElectromagnetsElectromagnets are activated for blocking the turnstile. Opposite to the traditionalsolenoids, electromagnets do not cause abrasion between the coil and the lockingdevice, avoiding malfunctions. Moreover, the activation is done through a transistor,and not a relay, avoiding the electromagnet to be blown due to the “contact wielding”(there is no mechanical wear).

ATTENTION: The relay contacts have maximum capacity of 1A 125 Vca

25

6.5.2.4 Connection scheme

Vcc

6.5.2.3 Sound alarm

The sound alarm output is activated by a NPN transistor (maximum 500 mA) everytime that CATRAX Automatic Plus:-receives a clearance signal (two short rings)-is not cleared and is forced during 1 second (1-second rings)-is stuck mid-turn for over 2 seconds (1-second rings)

Connect the outputs according to the following image:

Soundalarm

Maximum current 500mA

Inputs

Outputs

Relay

Access control boardInputs

Digicon Control board

Outputs

Retu

rn s

ignals

26

12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1

BOX SENSOR

ELECTROMAGNETS

TURNSTILE SENSORS

DIGICON CONTROL BOARD

INPUTS CN8 OUTPUTS CN9

GN

D+

24V

OU

TP

UT

NP

N 5

00m

A

OU

TP

UT

NP

N 5

00m

AO

UT

PU

TN

PN

500m

A

VD

LRAZ

VMPT

6.5.2.5 Pictogram

The pictogram's outputs are activated by NPN transistors (maximum 500 mA) atthe moment of activation, the GND is sent through a corresponding output..

6.5.2.6 Pictogram’s connections

6.5.3.Configuration of control board - Switch Ds1 and Ds2

The switch (or dipswitch) DS1 allows programming the following actions:-passage direction-Maximum time for turns-NO inputs (relay or pushbutton contact normally open and without input voltage),enabling passage in face of these signals; or NC inputs (relay or pushbutton contactusually closed and with input voltage), enabling passage in the absence of thesesignals.-enabling of a signal for a sound alarm if the access control remains at mid turn formore than 5 seconds.

To program DS1, put each pin in the desired position, according to the table below:

The switch (or dipswitch) DS2 allows programming the following actions:- invitation- turning speed- passage counting

To program DS2, put each pin in the desired position, according to the table below:

27

KEY 1 2 3 4 5 6 7 8

Habilita Sinal Sonoro ON

Desabilita Sinal Sonoro  OFF

Entradas NA ON

Entradas NF OFF

Habilitação por Borda OFF

Habilitação por Nivel ON

Trancada nos dois sentidos ON ON

Trancada no sentido direita para esquerda OFF ON

Trancada no sentido esquerda para direita ON OFF

Liberada em ambos sentidos OFF OFF

Habilita Sinal Sonoro na metada do giro ON

Desabilita Sinal Sonoro na metada do giro OFF

Espera até a primeira passagem (Sem Timeout de giro) ON ON

05 segundos catraca 120° OFF ON

10 segundos catraca 120° ON OFF

15 segundos catraca 120° OFF OFF

DIP SWITCH DS1

KEY 1 2 3 4 5 6 7 8

Enables invitation ON

Disables invitation OFF

Nominal speed ON

Half nominal speed OFF

Enables clockwise counting ON

Disables clockwise counting OFF

Enables anti-clockwise counting ON

Disables anti-clockwise counting OFF

Enables bob return and disables box ON

Enables box return and disables bob OFF

Retention time of the card in the box for reading 1s ON

Retention time of the card in the box for reading 2s OFF

Disk emulation for MCA ON

Disables disk emulation OFF

DIP SWITCH DS2

28

6.6 Anti-panic system

CATRAX Automatic Plus has an electromechanical device for anti-panic system (alsocalled drop-arm device). The mechanism is composed by a mechanical set activatedby high-performance solenoid, maintaining the arm raised during normal operation.In case of power outage (when the installation has no no-break), or through acommand sent via system, or the activation of an emergency button in the controlroom, the electromechanical device is deactivated, dropping the arm that preventsturn, clearing the entrance of any barrier. This device can be connected in series,allowing the clearance of all turnstiles at once from one single point.

29

6.6.1 Assembling the arms

After positioning and aligning the turnstile in its operation place, it is time to assemblethe arms. Make sure you have all the necessary items and that the turnstile is turnedoff, since you have to unscrew the bowl to attach the arms.The arms are provided disassembled. To assemble them, follow the instructionsprovided below:The wrench used for assembling must be an Allen n.8 and the screw must be tightenedto the maximum to ensure good fixation. All three arms must be attached to the samecentral upper point.

Repeat this operation in the three arms and make sure all of them are well fixed.

INFORMATION:

- The cover for accessing the screws is fitted into place for pening/closingoit.

- To assemble the arms of CATRAX Automatic Plus, use an Allen n.8 wrench.

.1st Let the mini

arm dop

2 Make sure the minind

arm’s plastic part is fittedin to the steel part

3 Fit the stainless steelrd

arm in the mini arm

4 Fix the screw inside theth

mini arm using an Allenn.8 wrench

5 Put the arm back in toth

its normal position

30

6.6.2 Maintenance test

The anti-panic system (drop-arm) was developed to facilitate the exit of people inemergencies. Thus, as a preventive measure, we recommend regular tests andinspections in this device (at least once a month). If the mechanism presents anydefect, request maintenance to a Digicon technician or a qualified company.Each inspection should carry out the following operational sequence for each ofthe three arms:� set the arm on the horizontal position;� turn the turnstile off;� check if the arm drops (if the arm does not drop, contact the dealer or

Digicon);� turn the turnstile on;� raise the arm until it reaches its normal position (the arm must stay in

horizontal position without external support; if it does not, contact the dealer orDigicon);

� repeat the procedure three times for each arm.

31

.

7.Maintenance7.1 Preventive and corrective routine maintenance:Electromagnets – Periodicity: ever 7000,000 cyclesThis routine maintenance requires the use of a multimeter. To check for the need ofcorrective actions, disconnect the CN3 from the access control board and check theelectromagnets' resistance. The value must be between 11 and 12.5 ohms betweenpins 1 and 2 and 3 and 4 of the electromagnet's connector. After measuring, connectCN3 to the board again.

Corrective actions:1. if you spot an incorrect resistance, a short-circuit or open electromagnet,replace it.2. if the electromagnet is not working, check the board or the voltage3. if the electromagnet is moving, fasten the base screws.

Electromagnets adjustments (if necessary)1. Force the lock against the sprocket and the equipment's arm until the lock iscompletely inside the first teeth (until the arm is locked)2. then, release the fixing screws and press the electromagnet against the lock'sframe, so that its area is completely against the electromagnet3. refasten the screws

Set of locks – Periodicity: every 700,000 cyclesTo check for the need of corrective actions, you must:-check the lock's correct position-check the wear of the lock's fitting in the sprocket

Corrective actions1. if the lock's position is incorrect, check the retaining ring and the spring thattightens the set2. if the lock's fitting to the sprocket is incorrect, replace the lock or the sprocket3. if lock's end is worn, replace the lock

Sprocket set – Periodicity: every 700,000 cyclesTo check for the need of corrective actions, you must:-check the wear of the sprocket's teeth-check the gap between the central axis, the sprocket, and the keyway

Corrective actions1. if you observe wear on the parts' teeth, replace the parts2. if you see a gap between the sprocket and the axis/keyway set, replace thesprocket or the keyway (to replace the sprocket, use a pulley puller)

ATTENTION: Preventive and corrective maintenance must be performed by a

professional trained/qualified by Digicon S.A

32

7.2 Defects and possible causes

Defect Possible causes Action

· Catrax Plus will notturn on

· The power supply’ input cable is not connectedproperly;

· The circuit breaker is off.

· Check the cables and the fuse.

· Catrax Plus islocked

· Optical sensors obstructed or defective. · Perform the preventive routinemaintenance on the sensor or

formward the equipment to theTechnical Assistance.

· Catrax Plus doesnot activate theelectromagnet

(turnstile cannot belocked).

· The cable is broken or the distance between theelectromagnet and the locking device is

maladjusted.

· Adjust the electromagnet orfordward the equipament to the

Technical Asistance.

· The arm does notremain in the

correct position

· There is wear, dirt, a broken sprong or lack oflubrication in the sphere base

· Request a replace ment for thefaulty part of forward the

equipament to the TechnicalAssistance.

· A Catrax AutomaticPlus does not in the

first toot.

· The distance between the electromagnet and thelocking device is maladjusted.

· Adjust the electromagnet orforward the equipament to the

Technical Assistance.

33

8 Technical characteristicsDimensions:

243(9,566")

300

(11,811

")

510

(20,0

78")

1042 (41,023")

digicon

Catrax

www.catrax.com.br

(17,440")

Other informations:Gross weight: Approx. 40kg (package included)

120 degress

Electromagnet’s power 24 V / 2cc A

Input ca ca Z: 100 V a 240 V 60HOutput cc +/-: 24,0 V 5% 4,5 A

De 0º a 50ºC C

INFORMATION: The measures in the images are given in milimeters

34

Distance betweenarms

Power supply

Operationaltemperature

Power Consumption during rotation is 36W.

35

9 Warranty and technical assistanceDigicon is responsible for the project, skilled labor, and quality of the materials used inthe manufacturing of our products, ensuring that the equipment and all parts are freeof manufacturing defects or problems. Digicon commits itself to replace or repair, aswe choose, any part or equipment presenting manufacturing defects without anycosts to the buyer, in our factory in Gravataí or our branch office in São Paulo, in theconditions set below:

1. The buyer is responsible for the costs of shipping (return service) of the product tothe factory in Gravataí or the branch office in São Paulo.

2. The warranty period is counted from the date of emission of the bill of sale andencompasses:a) 12 (twelve) months for equipment, accessories, parts, and pieces, including thelegal warranty period of 90 (ninety) days.

Legal warrantyThe customer has the period of 90 (ninety) days, from the date of emission of the bill ofsale, to complain about apparent defects (easily observable in the product), such asthe items that constitute the product's exterior and any other area accessible to theuser, just like appearance parts and general accessories.

b) 90 (ninety) days for repairs or technical assistance

3. Warranty shall be granted to the buyer only in the face of the bill of sale (original orcopy)

4. Warranty does not apply in the following cases or conditions:a) defects and damages caused by accidents, negligence, or reasons of force majeureb) defects and damages caused by inappropriate storage or lack of prolonged usec) defects and damages caused by improper use of the equipmentd) defects and damages caused by improper operation or installation of the equipmente) vandalismf) natural impacts (lightning, flooding, etc.)g) defects and damages caused by abnormal temperature conditions,voltage/frequency, or humidity out of the levels specified in the installation andoperation manual, once provenh) reconditioning, chrome plating, nickel plating, and painting

5. Warranty shall be automatically canceled for equipment that:a) suffers modifications, adaptations, or any alterations performed by the client or bythird parties without Digicon's written consentb) goes through maintenance or repairs by people not authorized by Digiconc) suffers alteration of serial number or violation of the identification labeld) is not paid for in the conditions, amounts, and deadlines described in the bill of sale

6. Digicon is not responsible for eventual losses suffered by the down time of theequipment

7. The repair of a warranted product will be performed inside the Digicon facilities.

Matriz/RSFábrica, Assistência Técnica e Vendas

Rua Nissin Castiel, 640 - Distrito Industrial.Gravataí/RS CEP 94045-420

Vendas: (0xx51) 3489.8700 / 3489.8745Assistência técnica: (0xx51) 3489.8903

E-mail: [email protected]

Filial/ SPDesenvolvimento, e VendasAssistência Técnica

Rua São Paulo, 82 - Alphaville.Barueri/SP CEP 06465-130Fone: (0xx11) 3738.3500

E-mail: [email protected]

Home page: www.digicon.com.br