MODEL F50 Downflow Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference.

MODEL F50 Downflow

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MODEL F50 Downflow

MODEL F50 DownflowService Manual

IMPORTANT: Fill in pertinent information on page 2 for future reference.

Page 2: MODEL F50 Downflow

MODEL F50

Page 2

* JOB NO.

Job Specification Sheet

* MODEL NO.

* WATER TEST

* CAPACITY PER UNIT MAX. PER REGENERATION

* MINERAL TANK SIZE DIA. HEIGHT

* BRINE TANK SIZE & SALT SETTING PER REGENERATION:

* F50 CONTROL VALVE SPECIFICATIONS

1 Type of Timer (see pages 16-19)

2 Timer Program Settings (see page 15)

A) Backwash min.

B) Brine & Slow Rinse min.

C) Rapid Rinse min.

D) Brine Tank Refill min.

3 Drain Line Flow Controller gpm

4 Brine Line Flow Controller gpm

5 lnjector Size #

6 A) Hard Water By-Pass

B) No Hard Water By-Pass

A) 7 day or 12 day

B) * 1,250 to 21,250 gallon meter or

* 6,250 to 106,250 gallon meter

* Other

C) Meter Wiring Package

1) System #4 - 1 tank; 1 meter; immediate or delayed regeneration

2) System #5 - 2 tanks; 2 meters; interlock

3) System #6 - 2 tanks; 1 meter; series regeneration

4) System #7 - 2 tanks; 1 meter; alternator

Page 3: MODEL F50 Downflow

MODEL F50

Page 2

* JOB NO.

1. Place the softener tank where you want to install the unit making sure the unit is level and on a firm base.

(Maximum 4 feet apart for twin units.)

2. All plumbing should be done in accordance with Iocal plumbing codes. The pipe size for the drain Iine

should be the same size as the drain Iine flow control female connection. Water meters are to be installed

on soft water outlets. Twin units with (1) one meter shall be installed on common soft water outlet of units.

3. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting. Leave at

Ieast 6“ between the DLFC and solder joints when soldering when the pipes are connected on the DLFC.

Failure to do this could cause interior damage to the DLFC.

4. Teflon tape is the only sealant to be used on the drain fitting. The drain from twin units may be run

through a common Iine.

5. Make sure that the floor is clean beneath the salt storage tank and that it is Ievel.

6. Place approximately 1”of water above the grid plate (if used) in your salt tank. Salt may be pIaced in the

unit at this time.

7. On units with a by-pass, place in by-pass position. Turn on the main water supply. Open a cold soft water

tap nearby and Iet run a few minutes or until the system is free from foreign material (usually solder) that

may have resulted from the installation.

8. Place the by-pass in service position.

9. Manually index the softener control into “service” position and Iet water flow into the mineral tank. When

water flow stops, open a cold water tap nearby and Iet run until air pressure is reIieved.

10.Electrical: AII electrical connections must be connected according to codes. Use electrical conduit if

applicable.

11. Plug into power supply.

Job Specification Sheet

* MODEL NO.

* WATER TEST

* CAPACITY PER UNIT MAX. PER REGENERATION

* MINERAL TANK SIZE DIA. HEIGHT

* BRINE TANK SIZE & SALT SETTING PER REGENERATION:

* F50 CONTROL VALVE SPECIFICATIONS

1 Type of Timer (see pages 18-21)

2 Timer Program Settings (see page 17)

A) Backwash min.

B) Brine & Slow Rinse min.

C) Rapid Rinse min.

D) Brine Tank Refill min.

3 Drain Line Flow Controller gpm

4 Brine Line Flow Controller gpm

5 lnjector Size #

6 A) Hard Water By-Pass

B) No Hard Water By-Pass

A) 7 day or 12 day

B) * 1,250 to 21,250 gallon meter or

* 6,250 to 106,250 gallon meter

* Other

C) Meter Wiring Package

1) System #4 - 1 tank; 1 meter; immediate or delayed regeneration

2) System #5 - 2 tanks; 2 meters; interlock

3) System #6 - 2 tanks; 1 meter; series regeneration

4) System #7 - 2 tanks; 1 meter; alternator

MODEL F50General Commercial Pre-Installation Check List

Installation Instructions

Page 3

Page 4: MODEL F50 Downflow

MODEL F50Upper Control Drive Assembly (For 50 Mechanical)

Page 4

1 8

56

7

4-2

20

9

10

11

1213

1415

16171819

32

4-1

12

20

FOR SM

Page 5: MODEL F50 Downflow
Page 6: MODEL F50 Downflow

MODEL F50Lower Control Drive Assembly (For 50 Mechanical)

Page 6

12

3 45

6

78

9 10

11

12

13

14

15

1617

18

19

2021

2223

2425

Page 7: MODEL F50 Downflow

MODEL F50Lower Control Drive Assembly (For 50 Mechanical)

Page 7

Item No. Quantity Part No. Description

1 1 051-00292-00 Conduit, Inter drive

2 2 051-00293-00 Conduit Connector

3 1 052-00117-00 Back Plate, Lower

4 1 052-00118-00 Bracket, Motor

5 4 066-00015-00 Screw

6 1 052-00124-00 Spacer, Indicator

7 1 099-01815-00 Drive Cam Assembly

8 1 052-00129-00 Pin, Spring

9 1 066-00015-00 Screw, Indicator

10 1 052-00120-00 Indicator, Off Line / Service / On Line

11 2 066-00047-00 Screw

12 1 043-00009-00 Micro Switch

13 1 052-00049-00 Insulator Switch

14 1 068-00018-00 Pin, Cam

15 2 066-00030-00 Screw, Motor Bracket

16 1 066-00015-00 Screw, Spacer

17 1 053-00025-00 Motor1 Assembly 220V

18 1 047-00016-00 Wire Assembly

19 2 066-00041-00 Screw, Window

20 1 051-00321-00 Window

21 1 060-00055-00 Seal, Window

22 1 060-00054-00 Seal, Cover

23 1 051-00321-00 Cover, Lower, Black

24 2 060-00037-00 O-Ring - Screw , Cover

25 2 052-00087-00 Screw, Cover

Bold faced items are recommended spare parts.

Page 8: MODEL F50 Downflow

MODEL F50Assembly Drawings and Part NumbersMedium Brining System Assembly

Page 8

16

a.Brine Tube(NR WB)b.Brine Tube(R WB)

Fittings for medium (1" to 1/2")brining system

27

1

34

56

78 9

1314

1512

10 11

2

18

19

17

20

21

24

25

22

23

26

Fittings for 1/2" BV

BLOC K-C

BLOC K-A

BLOC K-B

Page 9: MODEL F50 Downflow

MODEL F50Assembly Drawings and Part NumbersMedium Brining System Assembly Parts List

Page 9

Item No. Quantity Part No. Description

1 1 052-00000-00 End Plug-Brine System Assembly

2 1 060-00046-00 O-Ring- AS020

3 1 060-00050-00 RFC Washer-5.0 gpm

4 1 051-00121-01 Flow Control Retainer

5 1 052-00131-00 Piston- Brine System Assembly

6 1 052-00130-00 Piston Rod- Brine System Assembly

7 2 060-00069-00 O-Ring- AS210

8 1 051-00322-00 Spacer- Brine System Assembly

9 1 052-00054-00 Brine Valve Body

10 1 052-00045-00 Insert sleeve

11 1 051-00082-00 Retainer

12 1 052-00012-00 Nut

13 1 060-00013-00 Quad Ring- ASQ009

14 1 058-00008-00 Spring- Brine Valve

15 1 068-00019-00 Retaining Ring d3

16 1 052-00002-01 Stem Guide

17 1 066-00021-00 Screw,ch,M5x70mm,A2-70

18 1 052-00044-00 Injector Cover

19 1 060-00039-00 Injector Cover Gasket

201 051-00289-00 5# Injector Nozzle

1 051-00102-00 6# Injector Nozzle

21 1 075-00003-00 Injector Screen

22 1 051-00101-00 Injector Body

231 051-00290-00 5# Injector Throat

1 051-00107-00 6# Injector Throat

24 1 051-00093-00 Water Disperser

25 1 060-00040-00 Injector Body Gasket

26 1 052-00058-00 Elbow Fitting

27 1 051-00119-00 Air Check

Bold faced items are recommended spare parts.

Page 10: MODEL F50 Downflow

MODEL F50Assembly Drawings and Part NumbersF50 Control Valve Assembly

Page 10

31

32

33

21

20

19

30

2

29

3

32

25

1012 10

11

171615

1314

2835

26

27

34

23

22

18

INLETOUTLET

2

3

1

24

11

FILTER PARTS

UPPER PI S TON ASS E MBLY

LOWER PI S TON ASS E MBLY

23

4 5 4 5 4 6

7 8 9

Block-A Block-B

Page 11: MODEL F50 Downflow

MODEL F50Assembly Drawings and Part NumbersF50 Control Valve Assembly

Page 11

Item No. Quantity Part No. Description1 2 066-00054-00 Screw – Filter Valve2 1 052-00044-00 Injector Cover3 1 060-00040-00 Injector Body Gasket4 6 060-00065-00 Piston Seal5 5 051-00288-00 Spacer6 1 051-00285-00 End Spacer 7 1 051-00406-00 End Plug Assembly8 1 052-00112-00 Piston Rod9 1 052-00111-00 Upper Piston10 2 051-00165-00 Spacer11 4 060-00084-00 Piston Seal12 1 051-00320-00 Spacer13 1 051-00319-00 Black End Plug Assembly(NRWB)14 1 060-00021-00 O-Ring – End Plug15 1 052-00122-00 Lower Piston Rod16 1 051-00171-00 Snap Ring – Piston Rod17 1 052-00125-00 Lower Piston18 1 075-00003-00 Injector Screen19 1 051-00102-00 6# Injector Nozzle20 1 051-00101-00 Injector Body21 1 051-00107-00 6# Injector Throat22 1 052-00128-00 1” NPT Pipe Cap 23 2 066-00030-00 Screw – Valve Mounting24 1 060-00047-00 BWFC Washer, 25gpm

251 052-00001-00 1" Flow Control Housing (NPT)1 052-00151-00 1" Flow Control Housing (BSP)

26 1 060-00061-00 Inner O-Ring - Regeneration Port To Upper Valve27 1 060-00006-00 Outer O-Ring - Regeneration Port To Upper Valve28 1 060-00041-00 Riser O-Ring29 2 066-00021-00 Screw – Injector Body30 1 060-00039-00 Injector Cover Gasket

311 052-00108-00 Upper Valve Body (NPT)1 052-00274-00 Upper Valve Body (BSP)

32 2 060-00068-00 Coupling O-Ring33 2 052-00127-00 Upper To Lower Valve Coupling

341 052-00319-00 Lower 2” Lower Valve (NPT)1 052-00126-00 Lower 2” Lower Valve (BSP)

35 1 060-00033-00 Valve-Tank O-Ring

Bold faced items are recommended spare parts.

Page 12: MODEL F50 Downflow

MODEL F50Assembly Drawings and Part Numbers 2" Flow Meter Assembly & Parts List

Page 12

1

2

3

4

5

6

78

910

11

14

13

12

ME C HANICAL ME TE R COVE R ASS 'Y E LE CTR ONIC ME TE R COVE R ASS 'Y

Item No. Quantity Part No. Description

1 1 052-00086-00 Impeller Shaft Retainer 2 1 051-00195-00 Impeller 3 1 052-00085-00 Impeller Shaft 4 1 060-00026-00 O-Ring 5 1 099-00734-00 Meter Cover Assembly (Mechanical) 6 4 066-00020-00 Screw-Hex Hd,M5*12

71 052-00320-00 2” Meter Body (NPT)1 052-00070-00 2” Meter Body (BSP)

8 1 060-00030-00 O-Ring-227

91 052-00321-00 Nipple Quick Connect (NPT)1 052-00071-00 Nipple Quick Connect (BSP)

10 1 051-00181-00 Flow Straightener 11 1 052-00072-00 Nut Quick Connect12 1 061-00003-00 Meter Cable Assembly (17.5”)

131 047-00013-00 Meter Cable Assembly (99.5”)1 047-00038-00 Meter Cable Assembly (300”)

14 1 099-01754-00 Meter Cover Assembly (Electronic)

Bold faced items are recommended spare parts.

Page 13: MODEL F50 Downflow

Page 13

Commercial Demand Regeneration Control Timer Settings MODEL F50 ECONOMINDERTM

Typical Programming ProcedureCalculate the gallon capacity of the system, subtractthe necessary reserve requirement and set the gallonsrequired by Iifting the gallon dial and rotating it so thatthe number of gallons required is aligned with thewhite dot on program wheel gear. Release and checkfor firm engagement with gear.Note, drawing shows 8,750 gallon setting. The capac-ity (gallons) arrow denotes remaining gallons exclusiveof fixed reserve.

To set Meter capacity at initial start-up either 1. Rotate manual regeneration knob one full revolution. —or— 2. Rotate program wheel manually clockwise or counter clockwise and align white dot with capacity arrow. This procedure must be followed any time the program wheel setting is changed.

Note:

These timers do not have a 24 hour gear. Setting thegallons on the program wheel and manual regenera-tion procedure are the same as previous instructions.

lmmediate Regeneration Timers:

5. In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain Iine.

How To Set The Time Of Day: 1. Press and hold the red button in to is engage the 24 hour gear. 2. Turn the 24 hour gear until the actual time of day is at the time of day pointer 3. Release the red button to again engage the 24 hour gear.

How To Manually Regenerate Your Water Condi-tioner At Any Time: 1. Turn the manual regeneration knob cIockwise one “click.” 2. This slight movement of the manual regeneration knob engages the program wheel and starts the generation program. 3. The black center knob will make one revolution in the folIowing approximately three hours and stop in the position shown in the drawing. 4. Even though it takes three hours for this center knob to complete one revoIution, the regenera tion cycle of your unit might be set for only one half of this time.

TO MANUALLY

TO SET TIME OF DAY-PRESS RED BUTTON ANDTURN LARGE AIAL UNTILTIME IS AT ARROW.

START CYCLE-TURN KNOBCLOCKWISE.

CAPACITECAPACITYKAPAZITATCAPACITACAPACIDAD

M3

CAUTIONALWAYS REMOVE CABLE

FROM METER BEFORE

SWINGING TIMER OPEN.

Program Wheel

Manual Regeneration Knob

Red TimeSet Button

White Dot(M3 Capacity)

M3 Label

ServicePositionIndicator

Capacity(M3 Remaining)

24 HR. Gear

Page 14: MODEL F50 Downflow

Page 14

Timer Setting ProcedureMODEL 3200 TIMER

How To Set Days On Which Water Conditioner Is ToRegenerate:

How To Set The Time Of Day:

How To Manually Regenerate Your WaterConditioner At Any Time:

How to Adjust Regeneration Time:1. Disconnect the power source.2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration knob.3. Loosen each screw slightly to release the pressure on the time plate from the 24 hour gear.4. Locate the regeneration time pointer on the inside of the 24 hour dial in the cut out.5. Turn the time plate so the desired regeneration time aligns next to the raised arrow.6. Push the red button in and rotate the 24 hour dial. Tighten each of the three screws.7. Push the red button and Iocate the pointer one more time to ensure the desired regeneration time is correct.8. Reset the time of day and restore power to the unit.

Rotate the skipper wheel until the number “1” is at the redpointer. Set the days that regeneration is to occur by slidingtabs on the skipper wheel outward to expose trip fingers.Each tab is one day. Finger at red pointer is tonight. Movingclockwise from the red pointer, extend or retract fingers toobtain the desired regeneration schedule.

Press and hold the red button in to disengage the drive gear.Turn the Iarge gear until the actual time of day is at the timeof day pointer.Release the red button to again engage the drive gear.

Turn the manual regeneration knob clockwise.This slight movement of the manual regeneration knobengages the program wheel and starts the regenerationprogram.The black center knob will make one revolutionin the following approximatelythree hours and stop in the position shown in the drawing.Even thought it takes three hours for this center knob tocomplete one revolution, the regeneration cycle of yourunit might be set only one half of this time.ln any event,conditioned water may be drawn after rinsewater stopsflowing from the water conditioner drain Iine.

TIME

OF DAY

ManualRegenerationKnob

24 HR. GearServicePositionIndicator

Red TimeSet Button

TO MANUALLY

TO SET TIME OF DAY-PRESS RED BUTTON AND

TURN LARGE DIAL UNTILTIME IS AT ARROW.

START CYCLETURN KNOBCLOCKWISE.

Skipper Wheel,12 Day(Shows Every OtherDay Regeneration)

Red Pointer

Page 15: MODEL F50 Downflow
Page 16: MODEL F50 Downflow

MODEL F50Timer Assembly (For Mechanical Clock)

Page 16

11

1615

13

12

1718

1920

21

6

22

23

2425

26

27

28

29

30

31

1

34

56

7

2

891032 6

14

24

27

27

Page 17: MODEL F50 Downflow

MODEL F50Timer Assembly (For Mechanical Clock)

Page 17

Item No. Quantity Part No. Description

1 1 051-00078-00 Timer Housing

2 1 069-00180-00 Decal- Instructions

3 1 051-00074-00 Cycle Actuator Arm

4 1 099-00177-00 24 Hour Gear Assembly

5 1 051-00089-00 Knob

6 4 066-00002-00 Screw,tchw,NO.6-20x1/2,b,black,Zn,1022

7 1 069-00179-00 Button Decal

8 1 099-00176-00 Skipper Wheel Assembly

9 2 078-00008-00 Ball

10 2 058-00003-00 Spring –Detent- Skipper Wheel

11 1 069-00181-00 Decal- Time of Day

12 1 052-00013-00 Spring Clip

13 1 058-00002-00 Spring- Denent- Main Gear

14 1 051-00081-00 Plastic Ball-0.25inch Dia.

15 1 057-00023-00 Main Drive Gear

16 1 099-00178-00 Program Wheel(ST) Assembly

17 1 057-00016-00 Idler Pinion

18 1 058-00001-00 Spring- Idler

19 1 057-00014-00 Idler Gear

20 1 057-00013-00 Driver Gear

21 1 052-00046-00 Motor Mounting Plate

22 1 053-00022-00 Motor2 Assembly (220V/50HZ)

23 3 066-00010-00 Screw,ccch,NO.6-32x1/8,Zn,1022

24 2 066-00011-00 Screw,ccch,NO.6-32UNCx1/4,Zn,1022

25 1 052-00041-00 Hinge Bracket

26 2 066-00012-00 Screw,tchw,NO.8-18x3/8,Zn,1022

27 3 052-00048-00 Insulator- Drive Assembly

28 1 043-00003-00 Switch3

29 1 043-00002-00 Switch2

30 2 066-00055-00 Screw, tcp, NO. M3-24x1.125,b,Zn,1022

31 1 051-00070-00 Skipper Wheel Ring

32 1 051-00071-00 Regeneration Pointer

Bold faced items are recommended spare parts.

Page 18: MODEL F50 Downflow

MODEL F50Timer Assembly (For Mechanical Meter)

Page 18

13

45

6

2

15

16

1718

1920

2122

23

5

24

25

26

27

28

29

3031

32

33

34

35

36

30

33

33

1314

6

9

7

810 11 12

Page 19: MODEL F50 Downflow

MODEL F50Timer Assembly (For Mechanical Meter)

Page 19

Item No. Quantity Part No. Description

1 1 051-00078-00 Timer Housing

2 1 069-00188-00 Decal- Instructions2

3 1 057-00011-00 Cycle Actuator Gear- SM

4 1 051-00089-00 Knob

5 4 066-00002-00 Screw,tchw,NO.6-20x1/2,b,black,Zn,1022

6 2 069-00179-00 Button Decal

7 1 069-00186-00 Gallons Label

8 2 066-00008-00 Screw-PSWA

9 1 057-00012-00 Progran Skipper Wheel

10 1 051-00049-00 Dial

11

1 069-00043-00 Quantity Label-40ton

1 069-00184-00 Quantity Label-200ton

1 069-00185-00 Quantity Label-375ton

1 069-01125-00 Quantity Label-1200ton

12 1 051-00050-00 Retainer-PSWA

13 1 051-00068-00 Program Wheel Retainer

14 1 066-00026-00 Screw,tcc,NO.6-20x1/2,JIS SUS304

15 1 069-00181-00 Decal- Time of Day

16 1 052-00013-00 Spring Clip

17 1 057-00024-00 Main Drive Gear(SM)

18 1 099-00192-00 Program Wheel(SM) Assembly

19 1 057-00016-00 Idler Pinion

20 1 058-00007-00 Spring- Idler

21 1 057-00014-00 Idler Gear

22 1 057-00013-00 Driver Gear

23 1 052-00046-00 Motor Mounting Plate

24 1 053-00022-00 Motor2 Assembly(220V/50HZ(

25 3 066-00010-00 Screw,ccch,NO.6-32x1/8,Zn,1022

26 1 057-00021-00 Drive Pinion- Program Wheel

27 1 051-00085-00 Clutch Drive Pinion

28 1 058-00004-00 Spring

29 1 051-00069-00 Spring Retainer

30 2 066-00011-00 Screw,ccch,NO.6-32UNCx1/4,Zn,1022

31 1 052-00041-00 Hinge Bracket

32 2 066-00012-00 Screw,tchw,NO.8-18x3/8,Zn,1022

33 3 052-00048-00 Insulator- Drive Assembly

34 1 043-00004-00 Switch4

35 1 043-00002-00 Switch2

36 2 066-00055-00 Screw,tcp,NO.M3-24x1.125,b,Zn,1022

Bold faced items are recommended spare parts.

Page 20: MODEL F50 Downflow

1. Softener fails to regenerate. A. Electrical service to unit has been interrupted.

B. Timer is defective.

C. Power failure.

A. By-pass valve is open.

B. No salt in brine tank.

C. Injector screen plugged.

D. Insufficient water flowing into brine tank.

E. Hot water tank hardness.

F. Leak at distributor tube.

G. Intemal valve Ieak.

H. Service adapter did not return to service.

A. Improper salt setting.

B. Excessive water in brine tank.

A. Iron buildup in Iine to water conditioner.

B. lron buildup in water conditioner.

C. Inlet of control plugged due to foreign material broken Ioose from pipes by recent work done on plumbing system.

A. Air in water system.

B. Improperly sized drain line flow control.

A. Fouled mineral bed.

A. Plugged drain Iine flow control.

B. Plugged injector system.

C. Timer not cycling.

D. Foreign material in brine valve.

E. Foreign material in brine iine flow control.

A. Assure permanent electrical service (check fuse, plug, pull chain or switch).

B. Replace timer.

B. Add salt to brine tank and maintain salt Ievel above water Ievel.

C. Reset time of day.

C. Clean injector screen.

D. Check brine tank fill time and clean brine line flow control if plugged.

E. Repeated flushings of the hot water tank is required.

F. Make sure distributor tube is not cracked. Check O-ring and tube pilot.

G. Replace seals and spacers and/or piston.

A. Check salt usage and salt setting.

B. See problem no. 7

A. Clean Iine to water conditioner.

A. Clean flow control.

B. Clean injector and screen.

C. Replace timer.

D. Replace brine vaIve seat and cIean valve.

E. Clean brine Iine flow control.

C. Remove piston and clean control.

B. Check for proper drain rate.

A. Check backwash, brine draw and brine tank fill. Increase frequency of regeneration. lncrease backwash time.

B. Clean control and add mineral cIeaner to mineral bed. lncrease frequency of regeneration.

A. Assure that well system has proper air eliminator control. Check for dry well condition.

H. Check drive motor and switch.

A. Close by-pass valve.2. Hard water.

3. Unit used too much salt.

4. Loss of water pressure.

5. Loss of mineral through drain Iine.

6. Iron in conditioned water.

7. Excessive water in brine tank.

Page 20

Service InstructionsMODEL F50

PROBLEM CAUSE CORRECTION

Page 21: MODEL F50 Downflow

Problem: Softener Delivers Hard Water.

Cause couId be that . . . Reserve Capacity Has Been Exceeded.

Correction: Check salt dosage requirements and reset program wheel to provide additional reserve.

Cause could be that . . . Program Wheel Is Not Rotating With Meter Output.

Correction: Pull cable out of meter cover and rotate manually. Program wheel must move without binding and

clutch must give positive “clicks” when program wheel strikes regeneration stop. lf it does not, repIace timer.

Cause could be that . . . Meter Is Not Measuring Flow.

Correction: Check meter with meter checker.

General Service Hints For Meter Control

Page 21

Service Instructions (Cont’d.)MODEL F50

Clean drain Iine flow control.

Clean injector.

Clean screen.

lncrease Iine pressure to 20 P.S.I.

Change seals, spacers and piston assembly.

Check drive motor and switches.

Determine if switch or timer is faulty andreplace it, or replace complete power head.

Check timer program and positioning ofcontrol. Replace power head assembly if notpositioning properly.

Remove power head assembly and inspect bore.Remove foreign material and check control invarious regeneration positions.

Replace seals and piston assembly.

Drain Iine fIow controI is pIugged.

Injector is plugged.

Injector screen plugged.

Line pressure is too low.

InternaI control Ieak.

Service adapter did not cycle.

Missadjusted, broken or shorted switch.

Valve is not programing correctiy.

Foreign material in control.

InternaI control Ieak.

A.

B.

B.

C.

C.

D.

E.

F.

A.

A.

8. Softener fails to draw brine.

PROBL EM CAUSE CORRECTION

9. Control cycles continuously.

10. Drain flows continuously.

A.

B.

B.

C.

C.

D.

E.

F.

A.

A.

Page 22: MODEL F50 Downflow

MODEL F50Dimensional Drawing

1) F50 Valve

Page 22

84.3mm

(3.32")

171.4mm

(6.75")

329.3mm

(12.96")

52.9mm

(2.08")

TAN

K

100mm

(3.94")

316.1mm (12.45")

173.5mm (6.83")

55.8mm (2.20")

222.4mm

(8.76")

75.5mm

(2.97")

91.3mm

(3.60")

31.9mm

(1.26")

25.4mm (1" )

12.7mm (1/2")101.6m

m (4"-8 U

N)

172mm (6.78")

Page 23: MODEL F50 Downflow

MODEL F50Timer Assembly (For Mechanical Meter)

Page 23

Piston Kits100-00015-00 Piston Kits-NRWB

Adapters100-00003-00 Fittings for medium (1” to 1/2”)

brining system

100-00027-00 Fittings for 1/2” BV

Seals & Spacers100-00045-00 F50 Spacers & Seals

Injector100-00021-00 #5 Injector Assembly

100-00026-00 #6 Injector Assembly

Meter (2" Electronic Flow Meter)

100-00038-00 99.5" Cable

100-00069-00 300" Cable

Meter(2" Extended Mechanical Flow Meter)

100-00042-00

Medium ½” Brine Valve

100-00031-00 Brine Valve Assembly RFC060-00100-00 5.0G

BWFC060-00072-00 0G

060-00047-00 25G

BWFC Housing Assembly100-00013-00 1” NPT 25G

100-00142-00 1” BSP 25G

Page 24: MODEL F50 Downflow