MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 1
MCC Software installation manual
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 2
Contents
1 Connection computer MCC .............................................................................. 3
1.1 Item numbers .......................................................................................................... 3
1.2 Jumper setting at the Dongle .................................................................................. 4 1.2.1 Version 1 ............................................................................................................................................. 4
1.2.1 Version 2 ............................................................................................................................................. 5
2 Installation of the software ...................................................................................... 6
3 Additional functions ............................................................................................... 14
3.1 Request of the in- and outputs .............................................................................. 14
4 Troubleshooting .................................................................................................... 15
4.1 The Toolbox doesn’t start ..................................................................................... 15
4.2 The „Code status“ doesn’t change from red to green after the code input ............ 15
4.3 The window „’XXXX-XX-XX‘ is not a valid date.“ pops up again and again .......... 16
4.4 No data connection to the MCC possible .............................................................. 16
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 3
1 Connection computer MCC
Connect the connection cable (USB A) from the dongle with a free USB port of your PC. The other connector (USB-B) is plugged in the dongle. The Y-adapter cable (9-pol.) SUB-D-plug) should be connect to the dongle. Unscrew the display cable at the display and connect the plug of the adapter cable with the M12 plug. This can be done also under power. If necessary the display can be connected to additional M12 connector of the adapter cable. Due to the used plug, an incorrect connection is excluded.
Caution when using display and PC together sometimes the display function is slow!
Depending on the operating system of the connected computer, the drivers for the dongle from the supplied CD must be installed manually. It is recommended to update to the latest version from the Internet.
1.1 Item numbers
Dongle with USB cable => 4920V0025
Y-Adapter cable => 4920R0037
Computer
Dongle
Display
Y-Adapter cable
Display cable from
MCC
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 4
1.2 Jumper setting at the Dongle
1.2.1 Version 1
Jumpereinstellungen:
1-2 connected
3-4 not connected
5-6 connected
7-8 connected
9-10 not connected
11-12 connected
13-14 not connected
15-16 connected
17-18 not connected
19-20 connected
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 5
1.2.1 Version 2
Jumper settings JP2 (from left to right):
JP1 (white) 1-2 connected
JP2 (red) 5-6 connected
JP3 (white) 8-9 connected
JP4 (green) 11-12 connected
JP5 (yellow) 14-15 connected
JP6 (red) 17-18 connected
JP7 (green) 20-21 connected
DIP-switch SW1:
1 Off
2 Off
3 Off
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 6
2 Installation of the software
System requirement: min. Windows XP
The Toolbox requires english Date format (JJJJ-MM-DD)! Troubleshooting see chapter 4.3
To install the software connect the computer to the MCC as described in the chapter 1. The dongle should be coded as described in section 1.2.
To install the software package start the file "MCC release X_XX.exe" (XX stands for the current software version, e.g. "MCC release 2_3_672_R.exe").
Click "Next" and select the desired directory path, e.g. "C:\MCC".
Click "Next" again to continue the installation.
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 7
During the installation, some shortcuts are created on the screen. Doubleclick the
shortcut to start the programm.
Click the button "Set access code" to enter the code.
Enter the provided "User code" and "Access code" in the appropriate fields.
Toolbox Expert
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 8
After the activation is done automatically the window changes as follows.
Save the code with the button "Save". The previous menu appears again. Enter the user code again and confirm with ENTER or OK.
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 9
After the activation, the following window appears automatically:
Now, the interface must be selected from the computer. In the menu bar under the item "Settings" select the "serial port" marked with MCC. In this example, e.g. "COM4".
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 10
The installation is now complete and you can select the desired configuration file (config).
For safety reasons the selected config file with the doortype will be shown again. If this is correct it can be confirmed with the "OK"button.
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 11
The upload is started by pressing the button "Update MCC".
Then appears a short warning message that the existing file on the MCC will be overwriet. This is confirmed with the "OK"button.
Now it follows a note which software parts will be upload or updated.
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 12
WARNING
During the update of the boot software the power of the MCC shoulds not turned off!
After activation of the "OK" button, the process will start automatically.
After successful completion the following text "MCC system start and ok" appears in the bottom window status display.
After the update the service counter should be reset "Restart service period".
The softwareupdate or the softwareupload of the new config is now finished.
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 13
A full description of the software can be viewed in the menu bar under "Help", or by pressing the F1 key.
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 14
3 Additional functions
3.1 Request of the in- and outputs
The state of the in- and outputs from the power and assembled MCC can be checked with the "Status" button. Green dot means 24 V power and red dot means 0 V. To display the right values of the config please download the config before checking.
At the same time the programmed function of inputs and outputs can be read. E.g. X 15 = > input = down, output = 24 V
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 15
4 Troubleshooting
4.1 The Toolbox doesn’t start
Each Toolbox version has got a fixed time stipulated periode of use.
After the expiration date, the software version is invalid and can no longer be used with the old code! Each registered Toolbox user gets together with the new code automatically in due time before the expiry of the old version via email a link to download the new software. If there no new version of the software, only a new access code will be sent. The old code can no longer used.
4.2 The „Code status“ doesn’t change from red to green after the code
input
Is the latest version of the software installed? The new code works not for old
versions but only for the current!
Download and install current software version
The „User code“has been entered incorrectly
Please compare the spelling with the E-mail. Enter the "User Code" in lowercase
(possibly operated caps-lock button note!)
During the initial installation of the Toolbox, it can happen that the first code is not
accepted.
After entering the first code and pressing the ENTER key delete the code and enter the second code from the E-mail.
Validity date, here till 2013-03-31
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 16
4.3 The window „’XXXX-XX-XX‘ is not a valid date.“ pops up again and
again
The set date format is incorrect!
Exit the Toolbox in the task manager of Windows and change the date format in Control Panel ("Regional and Language Options") to the date format "YYYY-MM-DD". Then start the Toolbox and enter the code again.
4.4 No data connection to the MCC possible
An existing data connection will be shown in the Toolbox window as a green dotted line. Due disconnect connection the line is missing.
An disconnected or interrupted connection can have the following reasons::
- The cables and plugs are not corrected in the right way.
- The MCC control unit is turned off
Existing data connection
MCC Software Installation Manual
MCC Software installation manual EN_05.docx 23.06.14 17
- The jumper in the dongle are not adjusted in the right way (see chapter 1.2)
- Install if necessary the driver of the dongle manually.
- A wrong interface connection is selected (Toolbox => Settings => Serial port => select COM-Interface with MCC in brackets behind).
- At Toolbox => Settings => At „Modbus/Bluetooth adapter“ no hook should be set!
- At Toolbox => Settings => At „Auto connect“ a hook should be set!