3
MASTER HPI-T Plus MASTER HPI-T Plus 400W/645 E40 1SL/12 Quartz metal halide lamps with clear outer bulb Warnings and Safety • Use only in totally enclosed luminaire, even during testing (IEC61167, IEC 62035, IEC60598) • The luminaire must be able to contain hot lamp parts if the lamp ruptures • For use with control gear designed for high-pressure mercury or sodium lamps • A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a vacuum cleaner. Product data General Information Cap-Base E40 [ E40] Operating Position P20 [ Parallel +/-20D or Horizontal(HOR)] Life to 5% Failures (Nom) 5000 h Life To 10% Failures (Nom) 7500 h Life to 20% Failures (Nom) 11000 h Life to 50% Failures (Nom) 20000 h System Description Horizontal Operating Position Light Technical Color Code 645 [ CCT of 4500K] Luminous Flux (Rated) (Min) 30000 lm Luminous Flux (Rated) (Nom) 32000 lm Color Designation Cool White (CW) Lumen Maintenance 10000 h (Nom) 70 % Lumen Maintenance 2000 h (Min) 75 % Lumen Maintenance 2000 h (Nom) 90 % Lumen Maintenance 20000 h 60 % Lumen Maintenance 5000 h (Min) 65 % Lumen Maintenance 5000 h (Nom) 80 % Chromaticity Coordinate X (Nom) 361 Chromaticity Coordinate Y (Nom) 372 Correlated Color Temperature (Nom) 4500 K Luminous Efficacy (rated) (Nom) 83 lm/W Color Rendering Index (Nom) 65 Operating and Electrical Power (Nom) 385 W Lamp Current Run-Up (Max) 6 A Lamp Current (EM) (Nom) 3.4 A Ignition Supply Voltage (Max) 198 V Ignition Supply Voltage (Min) 198 V Ignition Time (Max) 10 s Voltage (Max) 135 V Voltage (Min) 115 V Datasheet, 2020, May 29 data subject to change Lighting Lighting

MASTER HPI-T Plus 400W/645 E40 1SL/12 - MASTER HPI-T Plus | P… · MASTER HPI-T Plus MASTER HPI-T Plus 400W/645 E40 1SL/12 Quartz metal halide lamps with clear outer bulb Warnings

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MASTER HPI-T Plus 400W/645 E40 1SL/12 - MASTER HPI-T Plus | P… · MASTER HPI-T Plus MASTER HPI-T Plus 400W/645 E40 1SL/12 Quartz metal halide lamps with clear outer bulb Warnings

MASTER HPI-T PlusMASTER HPI-T Plus 400W/645 E40 1SL/12

Quartz metal halide lamps with clear outer bulb

Warnings and Safety• Use only in totally enclosed luminaire, even during testing (IEC61167, IEC 62035, IEC60598)

• The luminaire must be able to contain hot lamp parts if the lamp ruptures

• For use with control gear designed for high-pressure mercury or sodium lamps

• A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and

remove the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do

not use a vacuum cleaner.

Product data

General Information

Cap-Base E40 [ E40]

Operating Position P20 [ Parallel +/-20D or Horizontal(HOR)]

Life to 5% Failures (Nom) 5000 h

Life To 10% Failures (Nom) 7500 h

Life to 20% Failures (Nom) 11000 h

Life to 50% Failures (Nom) 20000 h

System Description Horizontal Operating Position

Light Technical

Color Code 645 [ CCT of 4500K]

Luminous Flux (Rated) (Min) 30000 lm

Luminous Flux (Rated) (Nom) 32000 lm

Color Designation Cool White (CW)

Lumen Maintenance 10000 h (Nom) 70 %

Lumen Maintenance 2000 h (Min) 75 %

Lumen Maintenance 2000 h (Nom) 90 %

Lumen Maintenance 20000 h 60 %

Lumen Maintenance 5000 h (Min) 65 %

Lumen Maintenance 5000 h (Nom) 80 %

Chromaticity Coordinate X (Nom) 361

Chromaticity Coordinate Y (Nom) 372

Correlated Color Temperature (Nom) 4500 K

Luminous Efficacy (rated) (Nom) 83 lm/W

Color Rendering Index (Nom) 65

Operating and Electrical

Power (Nom) 385 W

Lamp Current Run-Up (Max) 6 A

Lamp Current (EM) (Nom) 3.4 A

Ignition Supply Voltage (Max) 198 V

Ignition Supply Voltage (Min) 198 V

Ignition Time (Max) 10 s

Voltage (Max) 135 V

Voltage (Min) 115 V

Datasheet, 2020, May 29 data subject to change

LightingLighting

Page 2: MASTER HPI-T Plus 400W/645 E40 1SL/12 - MASTER HPI-T Plus | P… · MASTER HPI-T Plus MASTER HPI-T Plus 400W/645 E40 1SL/12 Quartz metal halide lamps with clear outer bulb Warnings

Voltage (Nom) 125 V

Controls and Dimming

Dimmable No

Mechanical and Housing

Bulb Finish Clear

Approval and Application

Energy Efficiency Label (EEL) A

Mercury (Hg) Content (Nom) 29.5 mg

Energy Consumption kWh/1000 h 424 kWh

Luminaire Design Requirements

Bulb Temperature (Max) 600 °C

Cap-Base Temperature (Max) 250 °C

Product Data

Full product code 871150017990615

Order product name MASTER HPI-T Plus 400W/645 E40 1SL/12

EAN/UPC - Product 8711500179906

Order code 928481600096

Numerator - Quantity Per Pack 1

Numerator - Packs per outer box 12

Material Nr. (12NC) 928481600096

Net Weight (Piece) 0.153 kg

Dimensional drawing

D

L

C

O

HPI-T Plus 400W/645 E40

Product D (max) O L C (max)

MASTER HPI-T Plus 400W/645 E40

1SL/12

47 mm 30.5 mm 168 mm 286 mm

Photometric data

LDLD_HPI-T-Light distribution diagram

300 400 500 600

100

300

500

200

400

700

600

W / (

m2 . 5

nm

. 1

00

0 lu

x)]

λ[nm]

LDPO_HPI-T_Plus_250W_400W-Spectral power distribution Colour

MASTER HPI-T Plus

2Datasheet, 2020, May 29 data subject to change

Page 3: MASTER HPI-T Plus 400W/645 E40 1SL/12 - MASTER HPI-T Plus | P… · MASTER HPI-T Plus MASTER HPI-T Plus 400W/645 E40 1SL/12 Quartz metal halide lamps with clear outer bulb Warnings

Lifetime

50

60

70

80

90

100

Su

rviv

al in

%

Burning hours0 100005000 15000 20000

LDLE_HPI-T_0001-Life expectancy diagram LDLM_HPI-T_0001-Lumen maintenance diagram

MASTER HPI-T Plus

© 2020 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or

completeness of the information included herein and shall not be liable for any action in reliance thereon. The

information presented in this document is not intended as any commercial offer and does not form part of any

quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered

trademarks of Koninklijke Philips N.V.

www.lighting.philips.com

2020, May 29 - data subject to change