    CAUTIONS2

    CME-LX100 No.2137-00

    LX-100

    Make sure that the power supply is off while wiring.Take care that wrong wiring will damage the sensor.Verify that the supply voltage variation is within the rating.Take care that if a voltage exceeding the rated range is applied, or if an ACpower supply is directly connected, the sensor may get burnt or damaged.In case noise generating equipment (switching regulator, inverter mo-tor, etc.) is used in the vicinity of this product, connect the frame ground(F.G.) terminal of the equipment to an actual ground.If power is supplied from a commercial switching regulator, ensure that the frameground (F.G.) terminal of the power supply is connected to an actual ground.Do not use during the initial transient time (0.5 sec.) after the power

    supply is switched on.Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.Do not run the wires together with high-voltage lines or power lines or putthem in the same raceway. This can cause malfunction due to induction.Take care that the sensor is not directly exposed to fluorescent lightfrom a rapid-starter lamp or a high frequency light device.If the surface of the sensing object has a shine,mount the sensor inclining approx. 10 to 15 degreesagainst the sensing object.Do not touch the lens of the sensor by hand directly. Ifthe lens becomes dirty, wipe it off with a soft cloth gently.

    When the inside lens is steamed up, unscrew thelens to get rid of the condensation.For LX-101--Z, be sure to use the optional cable with connector.Extension up to total 100m is possible with 0.3mm2, or more, cable.However, in order to reduce noise, make the wiring as short as possible.

    This sensor is suitable for indoor use only.Do not use this sensor in places having excessive vapor, dust, etc., orwhere it may come in direct contact with water, or corrosive gas.Take care that the product does not come in direct contact with water,oil, grease, or organic solvents, such as, thinner, etc.Make sure that stress by forcible bend or pulling with 76N, or more, forceis not applied directly to the sensor cable joint.This sensor cannot be used in an environment containing inflammableor explosive gases.Never disassemble or modify the sensor.

    INSTRUCTION MANUAL

    Digital Mark SensorPhotoelectric Sensor

    Thank you very much for using SUNX products. Please read this Instruction

    Manual carefully and thoroughly for the correct and optimum use of this

    product. Kindly keep this manual in a convenient place for quick reference.

    Never use this product as a sensing device for personnelprotection.In case of using sensing devices for personnel protec-tion, use products which meet standards, such asOSHA, ANSI or IEC etc., for personnel protection ap-plicable in each region or country.

    WARNING

    1015SPECIFICATIONS1

    Notes: 1)

    2)The connector type LX-101-Z is 100mA.

    The connecting cable is not supplied as an accessory for the connector type

    LX-101-Z. Make sure to use the optional cables with connector below:

    CN-24B-C2 (Straight type, 4-core, Cable length: 2m) CN-24BL-C2 (Elbow type, 4-core, Cable length: 2m)

    CN-24B-C5 (Straight type, 4-core, Cable length: 5m) CN-24BL-C5 (Elbow type, 4-core, Cable length: 5m)

    Max. sink current: 50mAApplied voltage: 30V DC or less

    (between output 2 and 0V)Residual voltage: 1.5V or less

    (at 50mA sink current)

    NPNopen-collector transistor

    Max. source current: 50mAApplied voltage: 30V DC or less

    (between output 2 and +V)Residual voltage: 1.5V or less

    (at 50mA source current)

    PNPopen-collector transistor

    Incorporated

    Incorporated OFF-delay timer/ON-delay timer, switchable either effective or ineffective

    'RUN': Green LED, 'TEACH', 'ADJ', 'COLOR', 'TIMER', 'PRO': Yellow LEDMODE indicator

    Response timeOperation indicator

    Mark mode: 2-level teaching/Full-auto teaching, Color mode: 1-level teachingSensitivity setting

    Incorporated

    IP67 (IEC)

    4 digits red LED display

    Orange LED (lights up when output 1 is ON)Mark mode: 45s or less, Color mode: 150s or less

    Digital display

    Timer function

    Protection

    Fine sensitivity adjustment function

    Material

    Ambient temperature

    120g approx. 55g approx.Weight

    Enclosure: PBT, Display: Polycarbonate, Operation buttons: Silicon rubber, Lens: Glass

    0.2mm2 5-core cabtyre cable, 2m longCable

    35 to 85% RH, Storage: 35 to 85% RH

    -10 to +55 (No dew condensation or icing allowed), Storage: -20 to +70

    Ambient humidity

    Red/green/blue LEDEmitting element

    Current consumption

    Teaching input

    Supply voltage

    Setting distance

    Output 1

    (OUT)

    Item

    Normal mode: 750mW or less (Current consumption 30mA or less at 24V supply voltage)EOC mode: 600mW or less (Current consumption 25mA or less at 24V supply voltage)

    12 to 24V DC+/-10%Ripple P-P10% or less

    10mm 3mm

    Low (ON): 0 to 2V DCSource current 0.5mA or lessInput impedance 10k approx.

    High (OFF): 5V to +V DC, or open

    High (ON): 5V to +V DCSink current 0.5mA or lessInput impedance 10k approx.

    Low (OFF): 0 to 0.6V DC, or open

    Max. sink current: 50mA (Note 1)Applied voltage: 30V DC or less

    (between output 1 and 0V)Residual voltage: 1.5V or lessat 50mA (Note 1) sink current

    NPN open-collector transistor

    Max. sourcecurrent: 50mA (Note 1)Applied voltage: 30V DC or less

    (between output 1 and +V)Residual voltage: 1.5V or lessat 50mA (Note 1) source current

    PNP open-collector transistor

    LX-101-P-ZLX-101-P

    LX-101-ZLX-101

    Connector typeCable type

    NPN output

    PNP output

    Type

    ModelNo.

    Mark mode: Light-ON/Dark-ON Auto-setting method on teaching,

    Color mode: Coincidence-ON/Non-coincidence-ONOutput operation

    IncorporatedShort-circuit protection

    Inverted operation of the output 1Output operation

    Short-circuit protection

    Output 2 (Inversion output)

    (OUT)

    MOUNTING3

    PART DESCRIPTION4

    I/O CIRCUIT DIAGRAMS5

    Notes: 1)2)

    The output 2 is not incorporated to connector type LX-101-Z.The current of the connector type LX-101-Z is 100mA.

    NPN output type

    D210k

    D11

    4

    12 to 24V DC10%

    Terminal No. of Connector Color code of cable type/cable withconnector

    (Brown) +V

    (Black) Output 1

    50mA max. (Note 2)

    50mA max. (Note2)(White)Output2 (Note1)

    3

    ZD1ZD2

    (Blue) 0V

    Tr1

    Tr2

    (Pink) Teaching input

    *1

    5V

    2Sensorcircuit

    Users' circuitInternal circuit

    LoadLoad

    Do not make thesensor detect anobject in this di-rection because itmay cause unsta-ble operation.

    Good No goodCare must be taken regarding the

    sensor mounting directrion with

    respect to the object's direction of

    movement.

    The tightening torque should be0.8Nm or less. Sensor mounting

    bracketMS-LX-1(Optional)

    M4 screw with washers

    COLOR

    TIMER

    OPE.

    RUN

    ADJ.TEACH

    Operation indicator(Orange)

    MODE/CANCEL key

    OFF/ENTER key

    ON/SELECT key

    MODE indicator / RUN (Green)

    MODE indicator / ADJ (Yellow)

    MODE indicator / TEACH (Yellow) MODE indicator / TIMER (Yellow)

    MODE indicator / COLOR (Yellow)

    MODE indicator / PRO (Yellow)

    Digital display (Red)