10
1 LX100 FIELD WIRING DIAGRAM FIGURE 10 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF NAPOLEON/LYNX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF NAPOLEON/LYNX IS PROHIBITED. PROPRIETARY AND CONFIDENTIAL PHOTO EYES RX TX 3-BUTTON STATION OPEN STOP CLOSE 3-BUTTON STATION OPEN STOP CLOSE 3-BUTTON STATION OPEN STOP CLOSE 3-BUTTON STATION OPEN STOP CLOSE OPEN CLOSE STOP COM WIRING FOR MULTIPLE 3 BUTTON STATIONS 24 VAC 24 VAC COM STOP CLOSE OPEN EDGE 1 EDGE 2 BEAM 1 BEAM 2 SINGLE COM MOMENTARY SWITCH NORMALLY OPEN SAFETY DEVICE (OPTIONAL) COAXIAL ANTENNA CONNECTION ** Rev. 09/11/15 LX-100 Wiring Connections NOT POLARITY SENSITIVE **Stop and Com must be jumpered when a 3-Button Wall Station is not Present

LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

1

LX100 FIELD WIRING DIAGRAM

FIGURE 10

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETARY AND C

ONFIDENTIAL

PHOTO

EYES

RXTX

3-BUTTON

STATIO

N

OPEN

STOP

CLO

SE

3-BUTTON

STATIO

N

OPEN

STOP

CLO

SE

3-BUTTON

STATIO

N

OPEN

STOP

CLO

SE

3-BUTTON

STATIO

N

OPEN

STOP

CLO

SE

OPEN

CLO

SE

STOP

CO

M

WIRIN

G FO

R MULTIPLE 3 BUTTO

N STA

TION

S

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

MO

MEN

TARY

SWITC

H

NO

RMA

LLY OPEN

SAFETY D

EVICE

(OPTIO

NA

L)

CO

AXIA

L AN

TENN

AC

ON

NEC

TION

**

Rev.09/11/15

LX-100W

iring Connections

NO

T POLA

RITY SENSITIVE

**Stop and Com

m

ust be jumpered

when a 3-Button

Wall Station is not

Present

Page 2: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

WIRING DIAGRAM

123

L3L2

L1

AdvancedClose Limit

Open Limit

L3 * * L2/N L1/L MA MB MC MD BRAKE SOLENOID

*If Present

Close Limit

Transformer

Line Voltage

24 Volt A

C

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

Rev.03/09/15

115 or 230 Volt A

CSingle PhaseLine In(G

round to case w

ithground

screw provid

ed)

Motor412

Themostat

LX100, BrakeSingle Phase w

/Instant ReversingM

otor

Blue

Red

Black

White

Orange

Red

Black

Gray

7 WIRE C

ON

NEC

TOR

3-Wire

3-Wire

BlueOrange

Red

Orange

Red

Blue

Gray

BRAKE

SOLEN

OID

Brown

Brown

HoistSw

itchw

henpresent

2

Page 3: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

WIRING DIAGRAM

3

123

L3L2

L1

AdvancedClose Limit

Open Limit

Close Limit

Transformer

Line Voltage

24 Volt A

C

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

Rev.08/15/14

115 or 230 Volt A

CSingle PhaseLine In(G

round to case with

ground screw provided)

Blue

Orange

Orange

Blue

Blue

Black

RedM

otor412

LX100, BrakeSingle Phase w

/1+ HP M

otorInstant Reverse

Red

Black

White

Orange

Gray

3-Wire

3-Wire

BlueOrange

Red

Orange

Red

Blue

Gray

BRAKE

SOLEN

OID

Brown

Brown

HoistSw

itchw

henpresent

Themostat(if present)

Black

White

T1L1

T3 T2 T1NOA2

NO L3 L2 L1A1

T2T3

NO

A1

A2

L2

NO L3

Page 4: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

123

L3L2

L1

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

Open Limit

AdvancedClose Limit

Close LimitRev.11/05/15

Transformer

9 8

45

2

63 71

*E

Overload Protector

(*when present)

Motor

LX100, BrakeThree Phase208-230 V

olt

Blue

Red

Black

White

Orange

Red

Black

Black

Black

Blue

Orange

Red

BlueOrange

Red

3-Wire

Brown

Orange

Orange

Blue

Blue

BRAKE

SOLEN

OID

when present

Gray

Gray

208-230 Volt

24 Volt A

C

3-Wire

208-230 Volt A

CThree PhaseLine In(G

round to case with

ground screw provided)

L3

NO L2

A2

A1

NO T3 T2

A1 L1L2L3

NO

A2

NO T1T2T3

L1T1

HoistSw

itchw

henpresent

Black

BlackBlue

Yellow

Brown

Thermal

Protector

AB

C

*A

*B *C

DE

F

*D*F

G*G

Yellow

Red

Brown

H*H

Blue

RedBlack

Norm

allyC

losed

4

WIRING DIAGRAM

Page 5: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

5

WIRING DIAGRAM

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

123

L3L2

L1

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

Open Limit

AdvancedClose Limit

Close LimitRev.11/05/15

Transformer

94

5

2

6

3 1*E

87

Overload

Protector(*w

hen present)M

otor

LX100, BrakeThree Phase460 V

olt

Blue

Red

Black

White

Orange

Red

Black

Black

Black

Blue

Orange

Red

BlueOrange

Red

3-Wire

Brown

Orange

Orange

Blue

Blue

BRAKE

SOLEN

OID

when present

Gray

Gray

460 Volt

24 Volt A

C

3-Wire

460 Volt A

CThree PhaseLine In(G

round to case w

ithground

screw provid

ed)

L3

NO L2

A2

A1

NO T3 T2

A1 L1L2L3

NO

A2

NO T1T2T3

L1T1

HoistSw

itchw

henpresent

Black

BlackBlue

Yellow

Brown

Thermal

Protector

AB

C

*A

*B *C

DE

F

*D*F

G*G

Yellow

Red

Brown

H*H

Blue

RedBlack

Norm

allyC

losed

Page 6: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

6

WIRING DIAGRAM

123

Emerson

Motor

LeadsT1-BlueT2-W

hiteT3-O

rangeT4-YellowT5-BlackT8-Red

L3L2

L1

T1L1

T3 T2 T1NOA2

NO L3 L2 L1A1

T2T3

NO

A1

A2

L2

NO L3

White

BlackBlack

ResetButton

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETARY AND C

ONFIDENTIAL

115 Volt

24 Volt A

C

Rev.05/28/14

Transformer

T1

Blue

Motor

LX100, BrakeSingle Phase w

/C

ap Start, 115V M

otor

Black

Red

Black

White

Orange

White

White

Black

Blue

Orange

Red

BlueOrange

Red

3-Wire

3-Wire

Red

Orange

Orange

BlueBlue

BRAKE

SOLEN

OID

T5G

ray

Gray

Open Limit

AdvancedClose Limit

Close Limit

T2T3 T8 T4

115 Volt A

CSingle PhaseLine In(G

round to case with

ground screw provided)

HoistSw

itchw

henpresent

Page 7: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

WIRING DIAGRAM

7

123

Emerson

Motor

LeadsT1-BlueT2-W

hiteT3-O

rangeT4-YellowT5-BlackT8-Red

L3L2

L1

T1L1

T3 T2 T1NOA2

NO L3 L2 L1A1

T2T3

NO

A1

A2

L2

NO L3

White

BlackBlack

ResetButton

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

230 Volt

24 Volt A

C

Rev.05/28/14

Transformer

T1

Blue

Motor

LX100, BrakeSingle Phase w

/C

ap Start, 230V M

otor

Black

Red

Black

White

Orange

White

Black

Blue

Orange

Red

BlueOrange

Red

3-Wire

3-Wire

Red

Orange

Orange

BlueBlue

BRAKE

SOLEN

OID

T5

Gray

Gray

Open Limit

AdvancedClose Limit

Close Limit

T2T3

T8 T4

230 Volt A

CSingle PhaseLine In(G

round to case with

ground screw provided)

HoistSw

itchw

henpresent

Page 8: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

WIRING DIAGRAM

8

123

L3L2

L1

ResetButton

AdvancedClose Limit

Open Limit

L3 * * L2/N L1/L MA MB MC MD BRAKE SOLENOID

T1 T4T8T3 T2T5

Motor

Close Limit

Transformer

Line Voltage

24 Volt A

C

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

Rev.11/03/15

115 Volt A

CSingle PhaseLine In(G

round to case with

ground screw provided)

LX100, BrakeSingle Phase w

/C

ap Start - 115VM

otor - LX225

Blue

Red

Black

White

Orange

Red

Black

Gray

7 WIRE C

ON

NEC

TOR

3-Wire

3-Wire

BlueOrange

Red

Orange

Red

Blue

Gray

BRAKE

SOLEN

OID

Brown

Brown

HoistSw

itchw

henpresent

White

Page 9: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

WIRING DIAGRAM

9

123

T2 T3 T8

L3L2

L1

ResetButton

AdvancedClose Limit

Open Limit

L3 * * L2/N L1/L MA MB MC MD BRAKE SOLENOID

Close Limit

Transformer

Line Voltage

24 Volt A

C

24 VAC

24 VAC

COM

STOP

CLOSE

OPEN

EDGE 1

EDGE 2

BEAM 1

BEAM 2

SINGLE

COM

THE INFO

RMA

TION

CO

NTA

INED

IN THIS

DRA

WIN

G IS THE SO

LE PROPERTY O

FN

APO

LEON

/LYNX. A

NY

REPROD

UCTIO

N IN

PART O

R AS A

WHO

LEW

ITHOUT THE W

RITTEN PERM

ISSION

OF

NA

POLEO

N/LYN

X IS PRO

HIBITED.

PROPRIETA

RY AN

D CO

NFIDEN

TIAL

Rev.11/03/15

230 Volt A

CSingle PhaseLine In(G

round to case with

ground screw provided)

Motor

LX100, BrakeSingle Phase w

/C

ap Start - 230VM

otor - LX225

Blue

Red

Black

White

Orange

Red

Gray

7 WIRE C

ON

NEC

TOR

3-Wire

3-Wire

BlueOrange

Red

Orange

Red

Blue

Gray

BRAKE

SOLEN

OID

Brown

Brown

HoistSw

itchw

henpresent

Black

T1T4T5

Page 10: LX100 FIELD WIRING DIAGRAMWIRING DIAGRAM 1 2 3 L3 L2 L1 Advanced Close Limit Open Limit L3 * * L2/NL1/L MA MB MC MD BRAKE SOLENOID *If Present Close Limit Transformer Line Voltage

20" 14

1316"

16 38 "

10 38 "

1.50 typ.

0.50

5"

6"

5"

SHOP DRAWING

10