® Link Heat www.heatlink.com Toll Free: 1-800-661-5332 Canada Fax: 1-866-450-1155 USA Fax: 1-800-869-6098 Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : HeatLink Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : ©2012-2017 HeatLink Group Inc. SUBSMP000SSHEX 2017-10-26 SMP - SS Snow Melt Panels with Heat Exchangers Submittal - Page 1 of 4 Qty Stk. # Nominal Panel Output see conditions below Primary Circulator Secondary Circulator Heat Exchangers Weight SMP175SS-HEX 175,000 Btu/hr Ferrous, Grundfos UPS26-99FC Ferrous, Grundfos UPS26-99FC 2× Single-wall brazed plate; FP3×8-20 93.5 lb (42.5 kg) SMP300SS-HEX 300,000 Btu/hr Ferrous, Grundfos UPS26-99FC Ferrous, Grundfos UPS26-99FC 2× Single-wall brazed plate; FP3×8-30 SMP300SS-HEX-H 365,000 Btu/hr Ferrous, Grundfos UPS26-99FC Ferrous, Grundfos UPS26-150FC 3× Single-wall brazed plate; FP3×8-30 Technical Data Max Ambient Temperature:................................ 120°F (49°C) Max Water Temperature: ................................... 200°F (93°C) Temperature Control Method: ............................ 3-way Mixing Valve with DDC Motor Mixing Valve Size: ............................................. 1- 1 4" Mixing Valve Cv: ................................................ 11.6 Temperature Control Range: ............................. 50-180°F (10-82°C) Power supply: .................................................... 110V(ac); max. current 6A Auxiliary Terminal: ............................................. 1 Piping:................................................................ 1" 304SS Tubing Piping Connections:........................................... 3 4" and 1" FNPT Material - Backplate: .......................................... Galvanized Steel Material - Enclosure:.......................................... Powder Coated Steel Standards / Listings CAN/CSA-C22 No.14, UL508 cETLus Description The SMP175SS-HEX, SMP300SS-HEX, and SMP300SS-HEX-H Snow Melt Panels are operation centers for fully automatic snow melt systems. They are intended for snow melt systems with non-dedicated heat sources, therefore heat exchangers are included to separate the primary loop water from the secondary loop glycol mixture. Standard snow melt control uses Snow/Ice Detector #DRVWSNS-SS (sold separately). Snow melt control can be changed to HeatLink ® #31680 Snow/Ice Detector and Melt Control (OPT-SMP-680) which uses Snow/Ice Detector #30090 and Snow/Ice Sensor Socket #30091 (both sold separately). Options OPT-SMP-680 - replace standard snow melt control with HeatLink ® #31680 Snow/Ice Detector and Melt Control (see SUB31680) Panel Output Conditions SMP175SS-HEX SMP300SS-HEX SMP300SS-HEX-H Primary Secondary Primary Secondary Primary Secondary Fluid type Water 50% glycol Water 50% glycol Water 50% glycol Entering fluid temp (°F) 185.0 110.0 185.0 110.0 182.0 110.0 Exiting fluid temp (°F) 155.0 141.2 155.0 143.7 152.0 142.8 Flow rate (US gpm) 12.0 12.6 20.6 20.0 24.9 24.9 Headloss 4.1 7.0 4.1 Allowable pressure drop outside of panel (ft head) 18 10 20

Link SMP - SS Snow Melt Panels with Heat Exchangers ... · PDF fileSerial #: XXX-XXXX Phase/Freq: ... ype UPS 26-99 FC 1 15 V 1 PH ... SS Snow Melt Panels with Heat Exchangers Submittal

Embed Size (px)

Citation preview

Page 1: Link SMP - SS Snow Melt Panels with Heat Exchangers ... · PDF fileSerial #: XXX-XXXX Phase/Freq: ... ype UPS 26-99 FC 1 15 V 1 PH ... SS Snow Melt Panels with Heat Exchangers Submittal

®

LinkHeatwww.heatlink.com

Toll Free: 1-800-661-5332Canada Fax: 1-866-450-1155USA Fax: 1-800-869-6098

Job or Customer :

Location :

Engineer :❏ ❏❏

Complies with Spec❏ Alternate Notes :

Contractor :

HeatLink Rep :

Submitted By : Date :

Approved By : Date :

P.O. Number : Date :

©2012-2017 HeatLink Group Inc.SUBSMP000SSHEX

2017-10-26

SMP - SS Snow Melt Panels with Heat ExchangersSubmittal - Page 1 of 4

Qty Stk. #Nominal Panel Output

see conditions below Primary Circulator Secondary Circulator Heat Exchangers Weight

SMP175SS-HEX 175,000 Btu/hrFerrous, Grundfos

UPS26-99FCFerrous, Grundfos

UPS26-99FC2× Single-wall brazed

plate; FP3×8-2093.5 lb

(42.5 kg)

SMP300SS-HEX 300,000 Btu/hrFerrous, Grundfos

UPS26-99FCFerrous, Grundfos

UPS26-99FC2× Single-wall brazed

plate; FP3×8-30

SMP300SS-HEX-H 365,000 Btu/hrFerrous, Grundfos

UPS26-99FCFerrous, Grundfos

UPS26-150FC3× Single-wall brazed

plate; FP3×8-30

Technical Data Max Ambient Temperature: ................................ 120°F (49°C)Max Water Temperature: ................................... 200°F (93°C)Temperature Control Method: ............................ 3-way Mixing Valve with DDC MotorMixing Valve Size: ............................................. 1-1⁄4"Mixing Valve Cv: ................................................ 11.6Temperature Control Range: ............................. 50-180°F (10-82°C)Power supply: .................................................... 110V(ac); max. current 6AAuxiliary Terminal: ............................................. 1Piping: ................................................................ 1" 304SS TubingPiping Connections: ........................................... 3⁄4" and 1" FNPTMaterial - Backplate: .......................................... Galvanized SteelMaterial - Enclosure: .......................................... Powder Coated Steel

Standards / ListingsCAN/CSA-C22 No.14, UL508cETLus

DescriptionThe SMP175SS-HEX, SMP300SS-HEX, and SMP300SS-HEX-H Snow Melt Panels are operation centers for fully automatic snow melt systems. They are intended for snow melt systems with non-dedicated heat sources, therefore heat exchangers are included to separate the primary loop water from the secondary loop glycol mixture. Standard snow melt control uses Snow/Ice Detector #DRVWSNS-SS (sold separately). Snow melt control can be changed to HeatLink® #31680 Snow/Ice Detector and Melt Control (OPT-SMP-680) which uses Snow/Ice Detector #30090 and Snow/Ice Sensor Socket #30091 (both sold separately).

Options❏ OPT-SMP-680 - replace standard snow melt control with HeatLink® #31680 Snow/Ice Detector and Melt Control (see SUB31680)

Panel Output Conditions SMP175SS-HEX SMP300SS-HEX SMP300SS-HEX-HPrimary Secondary Primary Secondary Primary Secondary

Fluid type Water 50% glycol Water 50% glycol Water 50% glycolEntering fluid temp (°F) 185.0 110.0 185.0 110.0 182.0 110.0Exiting fluid temp (°F) 155.0 141.2 155.0 143.7 152.0 142.8Flow rate (US gpm) 12.0 12.6 20.6 20.0 24.9 24.9Headloss 4.1 – 7.0 – 4.1 –Allowable pressure drop outside of panel (ft head)

– 18 – 10 – 20

Page 2: Link SMP - SS Snow Melt Panels with Heat Exchangers ... · PDF fileSerial #: XXX-XXXX Phase/Freq: ... ype UPS 26-99 FC 1 15 V 1 PH ... SS Snow Melt Panels with Heat Exchangers Submittal

®

LinkHeatwww.heatlink.com

Toll Free: 1-800-661-5332Canada Fax: 1-866-450-1155USA Fax: 1-800-869-6098

©2012-2017 HeatLink Group Inc.SUBSMP000SSHEX

2017-10-26

WARNING!!!Consult Manual Before Use

AVERTISSEMENT!!!Consulter le

manual avant l’usage

HeatLink Group Inc.4603E - 13th Street NECalgary, Alberta, CanadaT2E 6M3Phone: (403) 250-3432Fax: (403) 250-1155www.heatlinkgroup.com

Conforms to Std CAN/CSA C22.2 No. 14Conforms to Standard UL 508

MADE IN CANADA

MODEL #: SMP300SS-HEX

D.O.M: Feb 2, 2012

Max Pres: 125psi/862kPa

Volts: 120/24 VAC

Serial #: XXX-XXXX

Phase/Freq: 1/60 Cycles

Max Temp: 100C/212F

Amps: Maximum 15

3189472

SOME UNION NUTS MAYBECOME LOOSE

AND CONSEQUENTLYLEAK THROUGH

TRANSPORTATIONVIBRATION AND

HANDLING. DO NOTOVERTIGHTEN UNION NUTSWHEN CORRECTING THIS.

Any alterations to electrical wiring andcontrols renders warrantynull & void.

Installation must conformto local codes. Check valve(s) if required are theinstallers responsibility.

Before servicing,disconnect powersupply

M A D E I N C A N A D A

CAUTION

HEAT SOURCE

Supply

Return

1 inch Ball Valves

Type UPS 26-99 FC115 V 1 PH60 Hz20 uF

P/N: 52722512 P1 PC: 0939US

IMPEDANCE

PROTECTED

FOR INDOOR USE ONLY

Class F|1/1(A)

P1 (w)

1.301.501.80

150179197

CUS

99K4

ULLISTED

MA

X. FlU

IDTE

MP. 230˚F

99K4LISTED UL

Type UPS 26-99 FC115 V 1 PH60 Hz20 uF

P/N: 52722512 P1 PC: 0939US

IMPEDANCE

PROTECTED

FOR INDOOR USE ONLY

Class F|1/1(A)

P1 (w)

1.301.501.80

150179197

CUS

99K4

ULLISTED

MA

X. FlU

IDTE

MP. 230˚F

99K4LISTED UL

WARNING HOTThis product

may have hot fluidcirculating through it.

DO NOT TOUCH !

11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

1 - 1 - 2N - L 3 4 5 6 7 8

ON

ET02ALARM

SMP - SS Snow Melt Panels with Heat ExchangersSubmittal - Page 2 of 4

Panel Components Primary Pump

Secondary Pump

3-Way Mixing Valve and 24V DDC Motor

6' Power Cord

24V(ac) Transformer

Snow Melt Control

Supply Sensor

Return Sensor

Thermometer

Heat Exchanger

Drain and Fill Valve

Pressure Relief Valve

1

2

2

3

3

10 10

12

11

11

4

4

5

5

6

6

7

7

8

8

9

10

11

12

9

9

1

SecondaryReturn

Expansion Tank

Pressure ReliefSecondary

Supply

Primary Supply

Primary Return

SMP300SS-HEX

11

Page 3: Link SMP - SS Snow Melt Panels with Heat Exchangers ... · PDF fileSerial #: XXX-XXXX Phase/Freq: ... ype UPS 26-99 FC 1 15 V 1 PH ... SS Snow Melt Panels with Heat Exchangers Submittal

®

LinkHeatwww.heatlink.com

Toll Free: 1-800-661-5332Canada Fax: 1-866-450-1155USA Fax: 1-800-869-6098

©2012-2017 HeatLink Group Inc.SUBSMP000SSHEX

2017-10-26

SMP - SS Snow Melt Panels with Heat ExchangersSubmittal - Page 3 of 4

38.659" (982 mm)

30.504"(775 mm)

®Heat Link

3-7⁄16"

13-3⁄16"

1-3⁄8"

8.0"(203 mm)

12" 3"

1-1⁄2"

5-3⁄4"7-3⁄4"

FT H

D

SMP175SS-HEX

FT HD Outside of Panel

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

45.0

0.0 5.0 10.0 15.0 20.0 25.0 30.0US GPM

SMP300SS-HEX

SMP300SS-HEX-H

Page 4: Link SMP - SS Snow Melt Panels with Heat Exchangers ... · PDF fileSerial #: XXX-XXXX Phase/Freq: ... ype UPS 26-99 FC 1 15 V 1 PH ... SS Snow Melt Panels with Heat Exchangers Submittal

®

LinkHeatwww.heatlink.com

Toll Free: 1-800-661-5332Canada Fax: 1-866-450-1155USA Fax: 1-800-869-6098

©2012-2017 HeatLink Group Inc.SUBSMP000SSHEX

2017-10-26

Technical data

60

Note: Dimensions in inches unless otherwise noted.

TM04

546

3

UPS 26-150 F/SF

TM04

601

4

32

11

23

A

BC

D FD

E

Flow range: 0-53 gpm

Head range: 0-46 feet

Motors: 2-pole, single-phase

Max. liquid temperature: 230 °F (110 °C)

Min. liquid temperature: 36 °F (2 °C)

Max. system pressure: 145 psi (10 bar)

Model Spd Volts Amps Watts Hp Capacitor

UPS 26-150 F/SF

3

115

3.5 370 1/6

40μF/180V2 3.1 335 1/6

1 2.5 265 1/6

3

208

1.7 350 1/6

10μF/400V2 1.5 310 1/6

1 1.2 250 1/6

3

230

1.7 370 1/6

10μF/400V2 1.5 335 1/6

1 1.2 265 1/6

Approvals

Model typeProduct number Dimensions [inches] Connection type

and sizeShipping weight

[lbs]115 V 208 / 230 V A B C D E F

UPS 26-150 F 95906630 95906631 6 1/2 7 1/8 5 7/8 3 7/8 3 3/4 3 1/8 GF 15/26 flange(2) 1/2" dia. bolt holes 17.35

UPS 26-150 SF 95906632 95906633 6 1/2 7 1/8 5 7/8 3 7/8 3 3/4 3 1/8 GF 15/26 flange(2) 1/2" dia. bolt holes 17.35

UPS 26-150 F/SF

UPSeries.book Page 60 Monday, March 21, 2011 8:54 PM

UPS26-99BFC Pump Curve

0

5

10

15

20

25

30

35

0 5 10 15 20 25 30 35Flow (gpm)

Hea

d (fe

et)

1st Speed 2nd Speed 3rd Speed

SMP - SS Snow Melt Panels with Heat ExchangersSubmittal - Page 4 of 4

InstallationInstallation must follow all of HeatLink's instructions and guidelines.

MaintenanceMaintenance must follow all of HeatLink's instructions and guidelines.

Related Documents• SMP000SS Installation, Operation, and Maintenance Manual Instructions (L6SMP000SS)• HeatLink Limited Heating Warranty

UPS 26-150 Pump Curve