NTS - 960R SERIES TOTAL STATION SERVICE MANUAL SOUTH SURVEYING & MAPPING INSTRUMENT CO., LTD.
2010
SOUTH201021
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 1
1 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Tools
Oscillograph Multimeter Collimator
Screwdriver Pliers AllenKey
Tweezers Polishing Sticks Cotton
Lubricant Alcohol withether GreenGrease
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 2
2 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Disassemblyandassembly
Preparation:
Pleasepreparetoolsasfollows:screwdriver,tweezer,pliers,allenKeyandalcoholready.Thenwashyourhands.
Useatraytocollectthescrews.
Useanotebooktowritedownthepositionoftheconnectionpointsandthecolorofwireswhennecessary.
Contents:
ThischaptermainlyintroducedthestandarddisassemblyprocedureofNTS960R.(Absoluteencoding),Pleasefollowthesestepswhentakingaparttheinstrument,andalsotheassemblyprocedure.Refertotherelatedchaptersforrepairingorreplacement.Applyafinaltopcoatofvarnishonthescrewsafterassembly,exceptverticaldiskcover,EDMcover,slipringcoveretc.Thefactorymightupgradesomeofthespareparts,ifyoufindsomedifferencesbetweenthismanualandyourinstrument,pleasecontactus.
Step
1. Removethecoverofverticaldiscsystem
Loosenoffthesixscrewsontheleftcoverwithascrewdriver,andthenopenthecovercarefully.
2. LCDPanel
Loosenoffthefourscrewswithascrewdriver.AndthenremovetheLCDcovercarefully.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 3
3 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
BeforeremovingtheLCDcover,pleasebecarefultheflatcableontheback.Firstopentheflatcableclampaccordingtothedirectionofarrow,andthenpullouttheflatcable,bothoftheLCDandtheflatcablearefragile,pleasebecareful.
Loosenoffthefourscrewswithascrewdriver.AndthenremovetheLCDcarefully.
Opentheflatcableclampaccordingtothedirectionofarrow,andthenpullouttheflatcable.
Loosenoffthefourscrewswithascrewdriver.AndthenremovetheLCDbackcovercarefully.
Opentheflatcableclampaccordingtothedirectionofarrow,andthenpullouttheflatcable.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 4
4 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
3.Anglemeasuringboard
Refertostep1,removethecover.Loosenoffthefourscrewsontheanglemeasuringboardwithascrewdriver.
Pullouttheplugscarefully,andrecordthepositionofeachplugforassembly.Pleasekeeptheanglemeasuringboardappropriatelyandsafely.
4.Right Cover Refertostep2,removetheLCD,Cutthenyloncabletiewithpliers.Donotcutthewires.
Loosenoffthesixscrewsontherightcoverandthenopenit.
Whenopeningthecover,pleasebecarefulthewire.Pullouttheplug,thenyoucanremovethecoverfreely.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 5
5 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
5.EDMCover
LoosenoffthefourscrewsontheEDMcoverandthenremovetheEDMcovercarefully.Makesurethatthetelescopetangentscrewislockedupincaseofscuffingtheinstrumentwhenyouloosenthosescrews.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 6
6 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
6.Distancemeasuringboard
Settheinstrumenttelescopeinreversedposition,thenremovethecoverontopoftheEDM.
Loosenoffthefourscrewsonthedistancemeasuringboardwithascrewdriver.
Pullouttheplugscarefully,recordthepositionofeachplugforreference.Pulloutthesignalplugcarefullyaccordingtothedirectionofredarrow.
Finshedthosestepsabove,reversetheboard,youwillseetherecevingfiberisstillconnectedwiththedistancemeasuringboard.Becarefulwiththefragilefiber.
Loosenalittlethesmallscrewonthetopofthereceivingfiberbasewithallenkey,thenpulloutthefibercarefully,andremovethemainboard.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 7
7 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
7.Fibers
WeuseforficatefiberontheNTS350series.Asshowninthefollowingfigure,thereisanmixedreceivingendandwhichdividesintotwofibers;oneisforinsidepathreceiving,theotherforoutsidepathreceiving.
Refertostep5,6.RemovethetwocoversofEDMandthedistancemeasuringboard.Ononesidewithmotorsandreceivingfiber,youcanfindasmallscrew;loosenitalittletillyoucanpullouttheinsidepathfiber.Asshowninfigure.
TurntheEDMover;loosenoffthefourscrewsonthemetalcover,andpullthefiberoutcarefullyfromtheholeinthemiddleofthemetalboard.
mixedreceivingend outsidepathreceivingfiberinsidepathreceivingfiber
Outsidepathfiberbase
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 8
8 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Asshowninfigure,loosenalittlethesmallscrewandthenpullouttheoutsidepathfiber,tillnowweremovethewholefiber.Sincethefiberisveryeasilybroken,pleasekeepitappropriatelyandsafely.
8.Verticalabsoluteencodingdiscsystems
Refertostep1and3,removetheverticaldisccoverandtheanglemeasuringboard.Loosenoffthe4screwsinAareaandtheother4inBarea.Nowyoucantakeofftheverticaldiscdustcover.
Loosenoffthe4screwsinCareaandtheother3inDarea.
Intheredcirclearea,thereare4blackflatheadCCDholdingscrews.Donotloosenthemwhenremovetheverticaldisk.
A B
c
D
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 9
9 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
FllowthestepstoassembletheVerticalabsoluteencodingdiscsystem:
AssemblethetwoverticalangleCCDsensorfirst.
Attentiontothislittletrianglemarkontheedgeoftheverticaldisc,thisisthe0anglemark.
Asshowninfigure,setthetelescopeinnormal,assembletheverticaldisksystemintotheappropriatepositioncarefully.AligntheholesforscrewsbetweentheEDMandtheverticaldisk,andatthesametimemakesurethesmalltrianglemarkisnearbythelowerCCD.Thisisveryimportant,ifthetrianglemarkisnotintherightpositionafterassemblethedisksystem,theverticalanglevaluereadingwillbewrong.
Tightenallthescrewswhenfinishedthosestepsabove.Anddonotforgetthewasherduringassembling.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 10
10 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
9.VerticalCCDunit
Refertostep1,3,8,removetheverticaldisk
coverDistancemeasuringboardandverticaldisksystem.Loosenoffthe4screwstodisassembletheCCDunit.Inthesamewaytoremoveanotheroneintheoppositeposition.
10.CCDBracket
Refertostep1,3,8,and9,removeverticaldiskcover,anglemeasuringboard,verticaldisksystem,andverticalCCDunit.Thenturnovertheverticaldisk,thereisacoppernut,loosenitoffwithpliers.
Takeoutverticaldiscfrombracket.Pleasekeepthemappropriatelyandsafely.
11.Verticaltangentscrew
Refertostep4,removetheslipringcover.Loosenalittlethetwosmallscrewswithallenkey.Presstheendofverticalbrakeringsystemaccordingtothedirectionofredarrow,atthesametimepullouttheverticaltangentscrewcarefully.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 11
11 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
12.Slipring
Refertostep1,removetheverticaldiskcoveranddisconnecttheslipringplugformtheanglemeasuringboard.Refertostep2,removetheLeftsideLCDandthebackcover.Refertostep4,cutthecabletieandpullouttheslipringwire.Thenloosenoffthetwoscrewsasshowninfigure.
Refertostep6.Pulloutthe4pinslipringplugfromthedistancemeasuringboard.Recordthecolorandthepositionofeachwirethenpullthemoutcarefullywithtweezers,pleasekeeptheplugappropriatelyandsafely.
Loosenoffthe3screwsasshowninfigurethenpullouttheslipringunit.
3.
4.
5.
6.
13.Verticalbrakering
Refertostep4,11,and12,removetheslipringcover,telescopetangentscrew,andtheslipring.Loosenoffthe3screwsasshowninfigure,andremovetheverticalbrakering.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 12
12 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
14.Axlesleeve
Refertostep4,10,11and12,removetheslipringcover,verticaltelescopetangentscrew,slipring,andtheverticalarrestinggearring.Loosenoffthe4screwsasshowninfigure,holdtheEDM,andpullouttheaxlesleevewithyourhands.Ifitblocks,donotforceremovetheaxlesleeve,pleasesendtheinstrumentbacktothefactory.
15.EDM
Refertostep114,turntheEDMtoreverseposition,holdtheEDMwithbothofyourhands,andtakeitoutaccordingtothedirectionofredarrow.Becareful,DonotdroptheEDM.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 13
13 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
16.Compensator
Refertostep1and4,removetheverticaldiskcover,compensatorplugontheanglemeasuringboard,leftsideLCDandbackcover,thencutthecabletie,pulloutthecompensatorwire,opentheslipringcover.
Loosenoffthe2screwsasshowninfigure,thenyoucantakeoutthecompensatorfreely.
17.Horizontaltangentscrew
Refertostep2,removetherightsideLCDandbackcover.
Loosenthetwolittlescrewswithallenkey;presstheendofhorizontalbrakeringsystemaccordingtothedirectionofredarrow,atthesametimepulloutthetangentscrewcarefully.
18.Horizontaldiscandverticalaxleunit
Refertostep1,2,3,4,5,and17,removetheverticaldiskcover,slipringcover,bothoftheLCDsandbackcovers,cutoffthecabletie,andpullouttheCCDplugs,removeoneEDMcoverandthehorizontaltangentscrew.
Takeoffthe4rubbercover.
Loosenoffthe3screwswithallenkey.
disassemblethetribrach.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 14
14 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Turnovertheinstrumentloosenoffthescrewsonthebackcover.
Useallenkeyloosenoffthe3baseholdingscrews,thentakeoffthebase,thenloosenoffthe6dustcoverholdingscrewsandtakeoffthedustcover.
Holdtheinstrumentbodywithbothofyourhands,andthenmoveitupcarefully.Payattentionaboutthehorizontalbrakeringsystem,andtheCCDwire.
19.HorizontalCCDunit
Refertostep18,disassemblethehorizontaldiscandverticalaxleunit,loosenoffthescrewsontheCCDunit,thenyoucanremovetheCCDunit.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 15
15 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
20.Verticalaxleunit
Refertostep18and19,,disassemblethehorizontaldiscandverticalaxleunit,thendisassembletheCCDunit,disassemblethetribrach.
Turnoverthehorizontaldiscandverticalaxleunit,loosenoffthescrewsonthebackcover.Becarefulwiththehorizontalangledisc.
loosenoffthecoppernutwithallenkey.
Movethebaseupaccordingtothedirectionofredarrow.Youwillfindtheverticalaxleandthebaseareseparated.
Tips:keepthebottomofthebaseonthetopmakesurethesteelballswillnotdrop,iflostanysteelball,thewholesteelballsmustbechangedbecausetheyareuniquesetforeveryinstrument.Afteryouremovethebasefromtheaxle,youshouldpickupallthesteelballsintoasafetycontainerimmediately.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 16
16 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
21.Platevial
Loosenofftheplatevialadjusting.
Refertostep3,removetheleftLCDalongwithitsbackcover,loosenoffthescrewsasshowninfigure,thenremovetheplatevial.
22.Opticalplummet
Refertostep1,removetheLeftcover.Usescrewdriverloosenoffthe2screwsontheOpticalplummet.
Pullouttheopticalplummet.
Pullouttheopticalplummetcarefully,andkeepitappropriatelyandsafely.
23.Eyepieceandcrosshair
Screwofftheeyepiececover,screwofftheeyepiece,loosenoffthefourscrewsinside,youcanremovethecrosshairfreely.
Summary:ThisisthedisassembleprocessofNTS350series,someofthesparepartsdisassembleprocessarenotmentioned.forexample:luminotron,motor,theinsidepathprism,telescopictubeetc.mostofthesepartsneedspecialtoolforadjustingwhenassemble.Sowedonotrecommendyoutodissemblethembyyourself.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 17
17 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Commonproblemforanglemeasuring
Errorcode17Adjustingthegapbetweencoppernutandaxlesleeve
mechanicalfailure
TightenCenterscrew
Error1
HorizontalCCD(adjustingorreplace)
Electronicfailure
Replaceanglemeasuringboard
Error2telescoperotatedtoofast(protectingerror)
Error3Mainbodyrotatedtoofast.
Error4,Error7VerticalCCDunit
A:badsignal(adjustingthesignal)
B:dustondisc(cleanthedisc)
C:CCDunitbroken,ordustonthesurfaceofCCD(replaceorclean)
D:Sunradiationonthedisc.
E:Mainboardbroken.
ERROR5,Error6HorizontalCCDunit
A:badsignal(adjustingthesignal)
B:dustondisc(cleanthedisc)
CCCDunitbroken,ordustonthesurfaceofCCD(replaceorclean)
D:Sunradiationonthedisc.
E:Mainboardbroken.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 18
18 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Batteryvoltage
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 19
19 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
3Daub polishing powder (Green grease) on the vertical axle.
4Set the polishing tool on the vertical axle then rotate it 2-3 rounds clockwise.
5Takeouttheaxle,andcleanthepolishingpowder.
Polishingaxlesleeve.
6Daub polishing powder on the polishing stick then put it into the axle sleeve and rotate it 2-3 rounds clockwise.
.
7Take out the polishing stick and clean the axle sleeve.
8Assemble the axle and axle sleeve (base unit). If the axle can rotate smoothly, that means the polishing process succeed.
9Iftheverticalaxlestillblocked,pleaserepeatthesteps28.
Axleandaxlesleevepositionchanged(fixposition)
Horizontalaxisblocked
Axle(Rusty,Moldy,Tilt)(polishing)
Polishingprocess:
Whenthehorizontalaxleblocked,pleasedonottrytorotatethetelescope,itwilldamagethehorizontalaxleandaxlesleeve.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 20
20 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
1Refertostep10indissemblechapter.Disassemblethehorizontalaxleandaxlesleeve.
2Cleanthelubricantonthehorizontalaxle.
3Daub polishing powder (Green grease) on the horizontal axle.
4Set the polishing tool on the horizontal axle then rotate it 2-3 rounds clockwise.
5Takeouttheaxle,andcleanthepolishingpowder.
Polishingaxlesleeve.
6Daub polishing powder on the polishing stick then put it into the axle sleeve and rotate it 2-3 rounds clockwise.
7Take out the polishing stick and clean the axle sleeve.
8Assemble the axle and axle sleeve. If the axle can rotate smoothly, that means the polishing process succeed.
9Ifthehorizontalaxlestillblocked,pleaserepeatthesteps28.
DisplayunitOnedisplayunitfailurewillcausebothofthemcantdisplay.Pleasechangeitonebyonetofindoutwhichoneisbroken.
CommunicationportfaultmaintenanceMakesurethecommunicationcableisgoodandconnectionbetweencomputerandTSissteady.The
communicationportiswellconnectedwiththemainboard.
Andcheckthebaud rate. If the fault still can not be ruled out, please change the main board.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 21
21 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
The name for angle-measuring board
Upper CCD unit socket
Bottom CCD unit socket
Slip-ring socket
Compensator socket
Horizontal CCD unit socket for short wire
Horizontal CCD unit socket for short wire
LCD socket
COM socket
Power supply socket
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 22
22 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
EDMfaultmaintenance
EDMtestprocess1Checkoutthemotorsareworkingornotafterpowerontheinstrument.(itsoundslikeclick).Ifnot:
1CheckthepowersupplytoEDMboard.Itshouldbe6V.ifthereisnopowersupply
1checktheslipringisshortcircuitornot,orbroken,replacetheslipring.
2checkthepowersupplyfromanglemainboardtoslipring.Ifthereisnopowersupply,replacetheanglemainboard.
3checkthebatterysupplythepowervoltagetoanglemainboardornot.
2Checkthemotorsworkingvoltage,itshouldbe2.5V,ifnot,replacetheEDMmainboard,checkthemotorsvoltageintheteststate(factorymode).
1Modemotorandinside/outsidepathmotorvoltagewillbealways2.5V.
2TestlightReducemotorwhenitisworking.
3Checkwhetherthemotorisbrokenornot.Ifbroken,replaceanewone.
2Checkthelasercomesoutornot,ifnotTheemittingtubeworkingvoltageshouldbe3v.Ifthereisnopowersupplyfrommeasuringboardtoemittingtube,replacethemeasuringboard.Ifthepowersupplyisgood,thenreplacetheemittingtube.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 23
23 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
3Checkthesignallevel:Poweron,press[systemsetup],andthen,select[systeminformation],thenpress[F1]5times[F4]5times.Enterthetestmode.
Whentestmodeactived,thescreenwillshows3newoptions:
1. 1.ADJCOEFFICIENT2. EDMADJUSTING3. INSTRUMENTACCURACY
Select[EDMadjusting]option,itshowstheEDMversionandcurrentworkingvoltage.
ThecorrectworkingvoltageiswrittenontheEDMboard.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 24
24 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Ifthecurrentworkingvoltageismuchdifferentthancorrectworkingvoltage,thenpress[next]pressF1keyswitchtostate3select[Hiv]tochangetheworkingvoltage,afterthatpresssettosave.
2 InNonPrismmode,shotonthewhitewall,outsidepathsignalshouldbe80150mv(Thesignalisrelativitybythereflectoranddistance.)ifthesignalisveryweak,thefibermaybebroken,replacethefiber.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 25
25 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
3Insidepathsignalshouldbe10001500mv.(PrismorNonPrismmode)ifnot,loosentheinsidefilterholdingscrewnearthefiber.Turntheinsidepathfiltertochangethesignal;tightenthescrewwhenthesignalintheworkingrange.
Press[tape]toswitchthetapefrom05,theirsignalshouldbe10001500mv,ifoneofthemnotundertherage,replacethemeasuringboard.
Ifallthetapescannotadjusttotherightrange,replacethefiberormeasuringboard.
4InSTATE1,switchthemeasuremodetoPRISM.Themeasuremodemotorwilldropdownthefilter.Thefilterwillblockthelaserandonlyallowsasmallquantitylasercomethroughthefilterfromthegapinthecenter.
Whenthelasercomesout,thegapshouldbeinthecenterofthelaserblockedonthefilter.
Ifnot,loosenthefixscrewstoadjustthepositionuntilthegapinthecenterofthelaser,andtightenthefixscrews,putsomevarnishonfixscrews.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 26
26 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
4CheckandAdjust3axis.(beforeadjust3axis,makesure2Ciscorrect.RefertototalstationCalibrationthe4thsection)
3axes:sightaxis,emittingaxis,receivingaxis.(The3axisshouldbematchtogether,ifnot,itwillcausetheinstrumentcannotmeasurelongdistance.
1.checkandadjustEmittingaxis
1Setthetotalstationonthetripodandlevelit.Putacrosshairboard50Meterawayfromtotalstation.Turnontheinstrument,enterthetestmode.SelectNonPrisminState1toletthelasercomesoutfromtheLenscenter.
2Setupatheodolitebesidethetotalstation.Useforobservethelaserdotonthecrosshairboard.
3MatchthetwocrosshairstogetherbetweenTOTALSTATIONandcrosshairboard.
4Adjustscrew1,2whichonthebaseboardtomovethelaserpointtotheleftorright.loosenscrew3,4thenturntheredirectionmirrortomovethelaserpointupordown,untilthelaserdotinthecenterofthecrosshair.
5loosentheholdingscrewthenTurnthefocusprismclockwisetomakelaserpointfocus.Tighttheholdingscrew.
12 34
FocusPrism
Redirectionmirror
HoldingSCREW
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 27
27 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
2CheckandadjustReceivingaxis
Checkthereceivingaxistoseeifitismatchedtogetherwiththesightaxis.ifnot,adjustthereceivingfiberbase.
RefertoChapter:disassemblystep6,7,pulloutthemixreceivingendfromthemeasuringboard.
Focusthetotalstationtoinfinity.
Asshowninfigure,useatheodoliteaimatthetotalstationlens,turnthetheodolitezoomringutillyoucanseetotalstationcrosshairclearly.
Aimthemixreceivingendtoalight.
Asshowninfigure,wecanseealightdotthroughthetheodoliteeyepiece.
Ifyoucannotseethelightdot,youneedtoadjusttheoutsidepathreceivingfiberto
focusthelightdotuntilyoucanseeitclearly.
LoosentheoutsidepathreceivingfiberholdingScrew,
movethefiberupanddowntofocusthelightdot,whenfinished,
Tightentheholdingscrew.
Loosenthreescrewsonthefiberbaseasshowninfigure.Movethefiberbasetomakethelightdotinthecenterofthetotalstationcrosshair.
Finally,tightenthosescrewsandputvarnishonthem.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 28
28 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
5TestPointontheEDMBoard1thesocketandplugontheEDMboard
EmittingFibersignalandPowersupplyplug.
Slipringsocket
3MotorsPowerSupplysocket
Opticalcouplingunitsocket
forficatefibermixreceivingendsocket
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 29
29 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
2EDMboardtestpoint
Workingvoltagetestpoint,sameasthestickerontheEDMboard(thisboardis173.2V)
Emittingfiberworkingvoltage,3.3V
BatteryPowersupply6V.
Sameasslipring
CPUpowersupply3.6V
Powersupplyformeasuretape
Workingvoltageis4.9v
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 30
30 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
6Opticalcoupler Opticalcouplerisausedforestimatethedistancebetweentotalstationandtarget.TheemittingdiodeandreceivingdiodeontheopticalcouplerconnectedtogetherandlookslikeaU.MakesuretheblackedgeofthelightfilterinsidetheU.(theemittingdiodeandreceivingdiode.)
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 31
31 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Commonfaultsanderror.
(1)
Outsidepathsignaltooweak,fiberbrokenorEDMboardbroken,replacefiberorEDMboard
(2)
ItdoesntmeasureunderPrismMode,butcanmeasureunderNonprismmode.fiberbrokenorEDMboardbroken,replacefiberorEDMboard
(3)
UnderNonprismmode,itcanmeasureinsometimes,butsometimesnot.insidepathmotoragainstwithotherparts,fixthemotorposition.orEDMboardbroken,replaceit.
(4)
ItdoesntmeasureunderNonPrismmode.Checkthefiberandupgradetheprogram,checktheEDMboard.
(5)
Measurespeedisslow.UpgradetheEDMprogram,connectthePC,PressF3andpoweron,upgradetheprogram.
(6)
Itdoesntmeasuredistance.Checktheinstrumentstepbystepaccordingthischapter.
(7)
Aimattheprismcenter,theinstrumentdoesntshootdistance,offsetthecrosshairfromtheprismcenter,theinstrumentstartshootdistance.
Theinstrumentonlymeasureshortdistance,butdoesntmeasurelongdistance.
CheckandAdjust3axis
(8)
Themeasureresultisnotstable,insidepathsignalistoostrong,adjustthesignalaccordingthischapterCheckthesignallevel
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 32
32 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
BA
C
BA
C
Calibrations
Preparation:
Pleasepreparescrewdriver,adjustingpin,varnish,hexagonwrench,leveltheinstrumentonthecollimator,washyourhandsandgetready.
Content:
Thischaptermainlyintroducesyouthestandardadjustingprocess,thefollowingstepsshouldbefinishedonthecollimator.Excepttheadjustmentofopticalplummet,theotherstepsshouldfollowthegivenorder;otherwiseyoucantgetthewrongresult.
Process:
1. PlateVial
Leveltheinstrumentonthecollimator.Asshowninthefigure,rotateinstrument,makeplatelevelparallelinthecenteroflevelingscrewAandB,andthenadjustslevelingscrewtomakeplatebubblecentered.Turntheinstrumentfor90degrees,adjustthethirdlevelingscrew,andmaketheplatebubblecentered.Repeatthesteps1and2,maketheplatebubblecenteredinabovetwopositions.
Rotateinstrument180.Iftheplatebubblenotcentered,adjustthefixscrew,movetheplatebubbleahalfofthedifference;
A B
C
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 33
33 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
2. CircularVial
Afterexaminingtheplatebubble,circularbubbleshouldbecenteredtoo(ornotbeyondthereticlecircularity),whichindicatesthecircularbubbleisverticaltoverticalaxis.ifnottheadjustmentstepsareasfollows.
1. Loosenthescrew(oneortwo)oppositewithbubbledeflectivedirection;
2. Tweaktightlythescrewonthedirectionaccordantdeflectiveuntilcircularbubbleiscentered;
3. Adjustthreeadjustmentscrewsforseveraltimesuntilcircularbubbleiscentered;
4. Theforcepowerfixingthreeadjustmentscrewsmustbeconsistentwhencircularleveliscenteredatlast.
3. CrossHair
Makesurethecollimatorcrosshairisgood.Trytomatchthetotalstationcrosshaircenterandcollimatorcrosshaircentertogether.Ifthetwocrosshairmatchedperfectly,meansthetotalstationcrosshairisgood.
Asshowninfigure.Ifthetotalstationcrosshairistilt,thenyouhavetocalibrateit.
Takeofftheeyepiececover,Loosenthethreecrosshairholdingscrews;movethecrosshairbasetomatchthetwocrosshairtogetherthenTightenscrews,andthendaubalittlevarnishonthosescrews.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 34
34 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
4. 2C(PerpendicularitybetweenSightAxisandHorizontalAxis)
Leveltheinstrument;aimatthecollimator,matchthetotalstationcrosshairwithoneofthehorizontalscalesonthecollimatorcrosshair.
0setthehorizontalangle.
Reversethetelescopeandaimatthesamescale,andreadthehorizontalanglevalue,whichshouldbe1808.Asshowninthefigure,thevalueofHRis1800040.
itmeansthe2Cis+40,wehavetoadjustit.
NTS960Rseriestotalstationhastwowaytocalibrate2C
Solution1:mechanicalcalibration
Turnthehorizontaltangentscrewtomakethehorizontalanglevalueto18000'20"halfofthe2Cvalue.Seetheshownfigure.
lookatthecrosshair,thecrosshairmovedalittlefromthescale(grayarea),takeofftheeyepiececoverandadjusttheleftandrightadjustingscrewstomakethecrosshairbacktomatchthescaleagain.Theprincipleisloosenoneadjustingscrewbeforetightenanother.
Aftertheadjustment,checkthe2Cagain,ifitstillover8,pleasedoitagain.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 35
35 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
When2C>1,itwillaffectthe3axis.First,youhavetofixthe2C,thencheckandadjustthe3axis,otherwiseitwillaffectedthedistancemeasurement.
Solution2Electroniccalibration(onlycanusewhen2C
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 36
36 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Press[set]toendthecalibrationprocessandthesystemwillshowtheresult.
Presssettosave.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 37
37 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
5.HighlowDifference(PerpendicularitybetweenHorizontalAxisandVerticalAxis)InspectionStepsandCriterion:
Onthefirstposition(mainboardisonyourleftside),aimatthehorizontalcollimator,matchthetotalstationcrosshairwithoneofthehorizontalscalesonthecollimatorcrosshair.Asshowninfigure.
RotatetheEDM,Aimatthelowercollimator,notedowntheintersectionbetweentotalstationcrosshairandcollimatorcrosshair.
Onthesecondposition(mainboardisonyourrightside),dothesameprocedureasabove,notedowntheintersectionbetweentotalstationcrosshairandcollimatorcrosshair.
Thedifferencebetweenthetwointersectionsishighlowdifference,whichshouldbelessthan10(1divisiononthecollimatoris30)
RefertoDisassemblypart4takeofftherightcover,Loosenthefourscrewsalittle.(notice:DONOTloosentoomuch)Accordingtotheredarrow,movetheaxlesleeveupanddowntocalibratethehighlowdifference.
Asshowninthefigure,adjusttheaxlesleevetillthecrosshairmovetothewhiteline.(Halfofthedifference)
Afterhighlowdifference,thefourscrewsshouldbetighttomakesurethehorizontalaxisissteady,daubsomevanishonthescrews,anddotheplatevialcalibrationafter.
LEFTHR
LEFTLOW
RIGHTHR
RIGHTLOW
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 38
38 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
6.Compensator
Makesuretheplatevialisgoodandleveltheinstrumentonthecollimator,poweronandpressesc,youcanseethemodel,numberandversionofsoftware.
SwitchontheTS,enter[systemsetup][systeminformation]pressF1fivetimesthenF45timestoactivethetestmode.
Select[ADJCoefficient],the[compensationvalues]showstheelectronicbubbleoffsetvalue.
XdirectioncalibrationloosentwoscrewsinAareaalittleknocktheleftandrightsideofthecompensatormaketheX=000'00",thentightenthescrews.
YdirectioncalibrationloosenscrewCturningscrewB,untilY=000'00",thentightenthescrews.
A A B C
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 39
39 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
7. IAngle(VerticalAngleIndexerror)
Leveltheinstrumentandaimatthecollimator(firstposition),asshowninfigure,matchthetotalstationcrosshairwithoneoftheverticalscalesonthecollimatorcrosshair.
AsshowninthefiguretheV1is900000.
Reversethetelescopeandaimatthesamescale,notedowntheverticalanglevalue.
AsshowninfiguretheV2is2700050.
Iangle=(v1+v2360)/2.Iangleshould
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 40
40 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
Reversethetelescope,aimatthecollimatorasshowninfigure,matchthetotalstationcrosshairwiththesameverticalscalesonthecollimator.
Presssettoendthecalibrationprocessandthesystemwillshowtheresultonthescreen.
Presssettosave.
SOUTHSURVEYING&MAPPINGINSTRUMENTCO.,LTD. 41
41 NTS960RSERIESTOTALSTATIONSERVICEMANUAL
8. OpticalPlummetInspectionStepsandCriterion
Settheinstrumentonatripod.Drawacrosshaironapieceofwhitepaperandputitontheground.Focustheopticalplummettoseethecrosshairclearlyandmovethepaper(orinstrument)tomatchtheopticalplummetcenterandcrosshaircentertogether.
Rotatetheinstrumentevery90toseeiftheopticalplummetcenterstillmatchedwithcrosshaircenterornot.
Ifnot,Asshowninfigure,rotateinstrument180,checktheopticalplummetcenteroffsetdistance.
Asshowninthefigure,takeoffopticalplummeteyepiececoveroff,adjustthefourscrews.
Movetheopticalplummetcenterahalftothecrosshaircenter.
Movethepaper(orinstrument)tomatchtheopticalplummetcenterandcrosshaircentertogetherandchecktheopticalplummetasabove.
Repeattheabovestepsuntiltheopticalplummetisgood.
COVERTOOLSDisassembly1.Left cover2.LCD panel3. Angle-measuring board4.Right cover5.EDM cover6.EDM board7.Fiber8.Vertical absolute encoding disc9.Vertical CCD unit10.CCD bracket11.Vertical tangent screw12.Slip ring13.Axle Sleeve14.Axle Sleeve15.EDM16.Compensator17.Horizontal tangent screw18.Horizontal disc and vertical axle unit19.Horizontal CCD unit20.Vertical axle unit21.Plate vial22.Optical plummet23.Eyepiece and crosshair
Common problem for angle measuringError code 1-7No display or can't power onAxle blockedAngle-measuring board socket name
EDM fault and test process1.Check motors2.Check laser3.Check signal4.Check 3 axis5.Check onboard test point6.Check Optical couplerCommon faults and error
Calibrations1.Plate vial2.Circular vial3.Crosshair4.2C5.High-low difference6.Compensator7.Index error8.Optical plummet