80
PART NUMBER: 02250231-030 R05 The information in this manual is current as of its publication date and applies to compressor models indicated on this cover with serial number: 201705110000 and all subsequent serial numbers until next revision of this manual or release of a replacement manual.. Publication date: 03/27/2020 Copyright © 2020 Sullair, LLC. All rights reserved. WARRANTY NOTICE Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its warranty. Subject to EAR, ECCN EAR99 and related export control restrictions. SAFETY WARNING Users are required to read the entire User Manual before han- dling or using the product. Keep the User Manual in a safe place for future reference. USER MANUAL Industrial Air Compressor LS90, LS90S, LS90V, LS110, LS110S, LS110V 125 & 150 hp (90 & 110 kW)

Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

PART NUMBER:02250231-030 R05

The information in this manual is current as of its publication date and applies to compressor models indicated on this cover with serial number:

201705110000and all subsequent serial numbers until next revision ofthis manual or release of a replacement manual..

Publication date: 03/27/2020Copyright © 2020 Sullair, LLC. All rights reserved.

WARRANTY NOTICE

Failure to follow the instructions and procedures in this manual, or misuse of this equipment, will void its warranty.

Subject to EAR, ECCN EAR99 and related export control restrictions.

SAFETY WARNING

Users are required to read the entire User Manual before han-dling or using the product. Keep the User Manual in a safe place for future reference.

USER MANUAL

Industrial Air CompressorLS90, LS90S, LS90V,

LS110, LS110S, LS110V125 & 150 hp (90 & 110 kW)

Page 2: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Service Training Courses

Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, andservicing of Sullair products. Individual courses on Stationary compressors, variable speed drives, compressorelectrical systems, and dryers are offered at regular intervals throughout the year at Sullair’s training facility locatedin Michigan City, Indiana.

Instruction includes training on the function and installation of Sullair service parts, troubleshooting commonfaults and malfunctions, and actual equipment operation. These courses are recommended for distributorservice personnel. There is also a basic Stationary compressor course available for end-users.

For details on course offerings, outlines, schedules, and cost information contact:

Sullair Training Department

1-888-SULLAIR or219-879-5451 (ext. 5623)

[email protected]

- Or Write -

Sullair1 Sullair Way

Michigan City, IN 46360Attn: Training Department

Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 3: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Table of Contents

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual Table of Contents

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 2

Section 1: Safety.......................................................................................................61.1 General............................................................................................................................................ 61.2 Personal protective equipment ........................................................................................................ 61.3 Pressure release ............................................................................................................................. 61.4 Fire and explosion ........................................................................................................................... 71.5 Moving parts .................................................................................................................................... 71.6 Hot surfaces, sharp edges and sharp corners................................................................................. 81.7 Toxic and irritating substances........................................................................................................ 81.8 Electrical shock................................................................................................................................ 81.9 Lifting............................................................................................................................................... 91.10 Entrapment ...................................................................................................................................... 91.11 Implementation of lockout/tagout................................................................................................... 101.12 Safety warnings............................................................................................................................. 111.13 Safety decals ................................................................................................................................. 12

Section 2: Description............................................................................................142.1 Introduction.................................................................................................................................... 142.2 Description of components ............................................................................................................ 142.3 Sullair air end, functional description............................................................................................. 142.4 Compressor cooling and lubrication system, functional description .............................................. 162.5 Compressor discharge system, functional description .................................................................. 172.6 Control system, functional description........................................................................................... 172.7 Air inlet system, functional description .......................................................................................... 192.8 Variable speed drive (VSD) components ...................................................................................... 202.9 VSD control system, functional description ................................................................................... 20

Section 3: Specifications .......................................................................................223.1 Tables of specifications—LS90 & LS110 ...................................................................................... 223.2 Lubrication guide ........................................................................................................................... 233.3 Application guide ........................................................................................................................... 243.4 Lubrication change recommendations and maintenance, fluid ..................................................... 243.5 ID, air-cooled (enclosed) ............................................................................................................... 253.6 ID, air-cooled (enclosed with optional weather hood).................................................................... 273.7 ID, air-cooled (open)...................................................................................................................... 293.8 ID, water-cooled (enclosed)........................................................................................................... 313.9 ID, water-cooled (enclosed with optional weather hood)............................................................... 333.10 ID, water-cooled (open) ................................................................................................................. 353.11 Piping & instrumentation, air-cooled (Wye-delta) .......................................................................... 37

Page 4: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Table of Contents LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R053 Subject to EAR, ECCN EAR99 and related export control restrictions.

3.12 Piping & instrumentation, air-cooled (VSD, Spiral Valve).............................................................. 393.13 Piping & instrumentation, water-cooled (Wye-delta) ..................................................................... 413.14 Piping & instrumentation, water-cooled (VSD, Spiral Valve)......................................................... 433.15 Wiring diagram (Wye-delta, Spiral Valve) ..................................................................................... 453.16 Wiring diagram (VSD) ................................................................................................................... 49

Section 4: Installation ............................................................................................ 524.1 Mounting of compressor................................................................................................................ 524.2 Ventilation & cooling...................................................................................................................... 52

4.2.1 Air-cooled compressors ...................................................................................................... 524.2.2 Water-cooled compressors................................................................................................. 524.2.3 Water system venting ......................................................................................................... 534.2.4 Draining the water system .................................................................................................. 534.2.5 Water quality recommendations ......................................................................................... 53

4.2.5.1 Scale ......................................................................................................................... 544.2.5.2 Corrosion................................................................................................................... 544.2.5.3 Biological and organic fouling (slime)........................................................................ 54

4.2.6 Seawater-cooled units ........................................................................................................ 544.3 Outdoor installation (sheltered) ..................................................................................................... 554.4 Service air piping........................................................................................................................... 55

4.4.1 Pipe sizing .......................................................................................................................... 564.4.2 Use of auxiliary receiver tank.............................................................................................. 56

4.5 Coupling alignment check ............................................................................................................. 574.6 Fluid level check............................................................................................................................ 574.7 Electrical preparation..................................................................................................................... 574.8 Motor rotation direction check ....................................................................................................... 57

Section 5: Operation .............................................................................................. 605.1 Introduction.................................................................................................................................... 605.2 Purpose of controls ....................................................................................................................... 605.3 Initial start-up procedure................................................................................................................ 615.4 Subsequent start-up procedure..................................................................................................... 615.5 Shutdown procedure ..................................................................................................................... 61

Section 6: Controller.............................................................................................. 626.1 Controller layout ............................................................................................................................ 626.2 Home page.................................................................................................................................... 646.3 Main Menu page............................................................................................................................ 656.4 User Preferences page .................................................................................................................. 666.5 Menu hierarchy.............................................................................................................................. 676.6 AirLinx™ remote monitoring.......................................................................................................... 68

6.6.1 Troubleshooting AirLinx communications ........................................................................... 68

Section 7: Maintenance ......................................................................................... 707.1 General.......................................................................................................................................... 70

Page 5: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual Table of Contents

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 4

7.2 Daily operation............................................................................................................................... 707.3 Maintenance after initial 50 hours of operation.............................................................................. 707.4 Maintenance every 2000 hours ..................................................................................................... 707.5 Fluid maintenance ......................................................................................................................... 707.6 Filter maintenance......................................................................................................................... 71

7.6.1 Fluid filter element replacement.......................................................................................... 717.7 Air filter maintenance..................................................................................................................... 71

7.7.1 Air filter element replacement ............................................................................................. 717.8 Separator maintenance ................................................................................................................. 71

7.8.1 Separator element replacement.......................................................................................... 727.9 Oil return / sight glass maintenance .............................................................................................. 737.10 Pressure regulator adjustment ...................................................................................................... 737.11 Water condensate drain maintenance........................................................................................... 747.12 Control line strainer ....................................................................................................................... 747.13 Shaft coupling maintenance .......................................................................................................... 747.14 Troubleshooting............................................................................................................................. 74

7.14.1 Introduction ......................................................................................................................... 747.14.2 Troubleshooting guide ........................................................................................................ 75

Page 6: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Table of Contents LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R055 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 7: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 1

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 1: Safety

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 6

Safety

1.1 GeneralSullair and its subsidiaries design and manufacture all oftheir products so they can be operated safely. However,the responsibility for safe operation rests with those whouse and maintain these products. The following safetyprecautions are offered as a guide which, if conscien-tiously followed, will minimize the possibility of accidentsthroughout the useful life of this equipment.

The compressor should be operated only by those whohave been trained and delegated to do so, and who haveread and understood this Operator’s Manual. Failure tofollow the instructions, procedures and safetyprecautions in this manual may result in accidents andinjuries. NEVER start the compressor unless it is safe todo so. DO NOT attempt to operate the compressor with aknown unsafe condition. Tag the compressor and renderit inoperative by disconnecting and locking out all powerat source or otherwise disabling its prime mover soothers who may not know of the unsafe condition cannotattempt to operate it until the condition is corrected.

Install, use and operate the compressor only in fullcompliance with all pertinent OSHA regulations and/orany applicable Federal, State, and Local codes,standards and regulations. DO NOT modify thecompressor and/or controls in any way except withwritten factory approval.

While not specifically applicable to all types of compres-sors with all types of prime movers, most of the precau-tionary statements contained herein are applicable to

most compressors and the concepts behind these state-ments are generally applicable to all compressors.

1.2 Personal protective equipmentA. Prior to installing or operating the compressor, own-

ers, employers and users should become familiarwith, and comply with, all applicable OSHA regula-tions and/or any applicable Federal, State and Localcodes, standards, and regulations relative to per-sonal protective equipment, such as eye and faceprotective equipment, respiratory protective equip-ment, equipment intended to protect the extremities,protective clothing, protective shields and barriersand electrical protective equipment, as well as noiseexposure administrative and/or engineering controlsand/or personal hearing protective equipment.

1.3 Pressure releaseA. Install an appropriate flow-limiting valve between the

service air outlet and the shut-off (throttle) valve,either at the compressor or at any other point alongthe air line, when an air hose exceeding ½″ (13 mm)inside diameter is to be connected to the shut-off(throttle) valve, to reduce pressure in case of hosefailure, per OSHA Standard 29 CFR 1926.302(b)(7)and/or any applicable Federal, State and Localcodes, standards and regulations.

B. When the hose is to be used to supply a manifold,install an additional appropriate flow-limiting valvebetween the manifold and each air hose exceeding½″ (13 mm) inside diameter that is to be connectedto the manifold to reduce pressure in case of hosefailure.

C. Provide an appropriate flow-limiting valve at thebeginning of each additional 75 feet (23 m) of hose inruns of air hose exceeding ½″ (13 mm) inside diame-ter to reduce pressure in case of hose failure.

D. Flow-limiting valves are listed by pipe size and flow-rated. Select appropriate valves accordingly, in

NOTE

Operator is required to readentire instruction manual.

Page 8: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

1: Safety LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R057 Subject to EAR, ECCN EAR99 and related export control restrictions.

accordance with their manufacturer's recommenda-tions.

E. DO NOT use air tools that are rated below the maxi-mum rating of the compressor. Select air tools, airhoses, pipes, valves, filters and other fittings accord-ingly. DO NOT exceed manufacturer’s rated safeoperating pressures for these items.

F. Secure all hose connections by wire, chain or othersuitable retaining device to prevent tools or hoseends from being accidentally disconnected andexpelled.

G. Open fluid filler cap only when compressor is not run-ning and is not pressurized. Shut down the compres-sor and bleed the receiver tank to zero internalpressure before removing the cap.

H. Vent all internal pressure prior to opening any line,fitting, hose, valve, drain plug, connection or othercomponent, such as filters and line oilers, and beforeattempting to refill optional air line anti-icer systemswith antifreeze compound.

I. Keep personnel out of line with and away from thedischarge opening of hoses or tools or other points ofcompressed air discharge.

J. DO NOT use air at pressures higher than 2.1 bar forcleaning purposes, and then only with effective chipguarding and personal protective equipment perOSHA Standard 29 CFR 1910.242(b) and/or anyapplicable Federal, State, and Local codes, stan-dards and regulations.

K. DO NOT engage in horseplay with air hoses asdeath or serious injury may result.

1.4 Fire and explosionA. Clean up spills of lubricant or other combustible sub-

stances immediately, if such spills occur.

B. Shut off the compressor and allow it to cool. Thenkeep sparks, flames and other sources of ignitionaway and DO NOT permit smoking in the vicinitywhen checking or adding lubricant or when refillingair line anti-icer systems with antifreeze compound.

C. DO NOT permit fluids, including air line anti-icer sys-tem antifreeze compound or fluid film, to accumulateon, under or around acoustical material, or on anyexternal surfaces of the air compressor. Wipe downusing an aqueous industrial cleaner or steam cleanas required. If necessary, remove acoustical mate-rial, clean all surfaces and then replace acoustical

material. Any acoustical material with a protectivecovering that has been torn or punctured should bereplaced immediately to prevent accumulation of liq-uids or fluid film within the material. DO NOT useflammable solvents for cleaning purposes.

D. Disconnect and lock out all power at source prior toattempting any repairs or cleaning of the compressoror of the inside of the enclosure, if any.

E. Keep electrical wiring, including all terminals andpressure connectors in good condition. Replace anywiring that has cracked, cut, abraded or otherwisedegraded insulation, or terminals that are worn, dis-colored or corroded. Keep all terminals and pressureconnectors clean and tight.

F. Keep grounded and/or conductive objects such astools away from exposed live electrical parts such asterminals to avoid arcing which might serve as asource of ignition.

G. Remove any acoustical material or other materialthat may be damaged by heat or that may supportcombustion and is in close proximity, prior to attempt-ing weld repairs.

H. Keep suitable fully charged Class BC or ABC fireextinguisher or extinguishers nearby when servicingand operating the compressor.

I. Keep oily rags, trash, leaves, litter or other combusti-bles out of and away from the compressor.

J. DO NOT operate the compressor without proper flowof cooling air or water or with inadequate flow of lubri-cant or with degraded lubricant.

K. DO NOT attempt to operate the compressor in anyclassification of hazardous environment unless thecompressor has been specially designed and manu-factured for that duty.

1.5 Moving partsA. Keep hands, arms and other parts of the body and

clothing away from couplings, belts, pulleys, fans andother moving parts.

B. DO NOT attempt to operate the compressor with thefan, coupling or other guards removed.

C. Wear snug-fitting clothing and confine long hair whenworking around this compressor, especially whenexposed to hot or moving parts.

D. Keep access doors, if any, closed except when mak-ing repairs or adjustments.

Page 9: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 1: Safety

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 8

E. Make sure all personnel are out of and/or clear of thecompressor prior to attempting to start or operate it.

F. Disconnect and lock out all power at source and ver-ify at the compressor that all circuits are de-ener-gized to minimize the possibility of accidental start-up, or operation, prior to attempting repairs or adjust-ments. This is especially important when compres-sors are remotely controlled.

G. Keep hands, feet, floors, controls and walking sur-faces clean and free of fluid, water or other liquids tominimize the possibility of slips and falls.

1.6 Hot surfaces, sharp edges and sharp corners

A. Avoid bodily contact with hot fluid, hot coolant, hotsurfaces and sharp edges and corners.

B. Keep all parts of the body away from all points of airdischarge.

C. Wear personal protective equipment including glovesand head covering when working in, on or around thecompressor.

D. Keep a first aid kit handy. Seek medical assistancepromptly in case of injury. DO NOT ignore small cutsand burns as they may lead to infection

1.7 Toxic and irritating substancesA. DO NOT use air from this compressor for respiration

(breathing) except in full compliance with OSHAStandards 29 CFR 1910 and/or any applicable Fed-eral, State or Local codes or regulations.

B. DO NOT use air line anti-icer systems in air linessupplying respirators or other breathing air utilizationequipment and DO NOT discharge air from thesesystems into unventilated or other confined areas.

C. Operate the compressor only in open or adequatelyventilated areas.

D. Locate the compressor or provide a remote inlet sothat it is not likely to ingest exhaust fumes or othertoxic, noxious or corrosive fumes or substances.

E. Coolants and lubricants used in this compressor aretypical of the industry. Care should be taken to avoidaccidental ingestion and/or skin contact. In the eventof ingestion, seek medical treatment promptly. Washwith soap and water in the event of skin contact.Consult Material Safety Data Sheet for informationpertaining to fluid of fill.

F. Wear goggles or a full face shield when adding anti-freeze compound to air line anti-icer systems.

G. If air line anti-icer system antifreeze compoundenters the eyes or if fumes irritate the eyes, theyshould be washed with large quantities of cleanwater for fifteen minutes. A physician, preferably aneye specialist, should be contacted immediately.

H. DO NOT store air line anti-icer system antifreezecompound in confined areas.

I. The antifreeze compound used in air line antifreezesystems contains methanol and is toxic, harmful orfatal if swallowed. Avoid contact with the skin or eyesand avoid breathing the fumes. If swallowed, inducevomiting by administering a tablespoon of salt, in eachglass of clean, warm water until vomit is clear, thenadminister two teaspoons of baking soda in a glass ofclean water. Have patient lay down and cover eyes toexclude light. Call a physician immediately.

1.8 Electrical shockA. This compressor should be installed and maintained

in full compliance with all applicable Federal, Stateand Local codes, standards and regulations, includ-ing those of the National Electrical Code, and alsoincluding those relative to equipment grounding con-ductors, and only by personnel that are trained, qual-ified and delegated to do so.

B. Keep all parts of the body and any hand-held tools orother conductive objects away from exposed liveparts of electrical system. Maintain dry footing, standon insulating surfaces and DO NOT contact anyother portion of the compressor when making adjust-

DANGER

Death or serious injury can result from inhaling compressed air without using proper safety equipment. See OSHA standards and/or any applicable Federal, State, and Local codes, stan-dards and regulations on safety equipment.

Page 10: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

1: Safety LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R059 Subject to EAR, ECCN EAR99 and related export control restrictions.

ments or repairs to exposed live parts of the electri-cal system. Make all such adjustments or repairs withone hand only, so as to minimize the possibility ofcreating a current path through the heart.

C. Attempt repairs in clean, dry and well lighted andventilated areas only.

D. DO NOT leave the compressor unattended with openelectrical enclosures. If necessary to do so, then discon-nect, lock out and tag all power at source so others willnot inadvertently restore power.

E. Disconnect, lock out, and tag all power at sourceprior to attempting repairs or adjustments to rotatingmachinery and prior to handling any ungroundedconductors.

1.9 LiftingA. If the compressor is provided with a lifting bail, then

lift by the bail provided. If no bail is provided, then liftby sling. Compressors to be air-lifted by helicoptermust not be supported by the lifting bail but by slingsinstead. In any event, lift and/or handle only in fullcompliance with OSHA standards 29 CFR 1910 sub-part N and/or any applicable Federal, State, andLocal codes, standards and regulations.

B. Inspect points of attachment for cracked welds andfor cracked, bent, corroded or otherwise degradedmembers and for loose bolts or nuts prior to lifting.

C. Make sure entire lifting, rigging and supporting struc-ture has been inspected, is in good condition and hasa rated capacity of at least the weight of the com-pressor. If you are unsure of the weight, then weighcompressor before lifting.

D. Make sure lifting hook has a functional safety latch orequivalent, and is fully engaged and latched on thebail or slings.

E. Use guide ropes or equivalent to prevent twisting orswinging of the compressor once it has been liftedclear of the ground.

F. DO NOT attempt to lift in high winds.

G. Keep all personnel out from under and away from thecompressor whenever it is suspended.

H. Lift compressor no higher than necessary.

I. Keep lift operator in constant attendance whenevercompressor is suspended.

J. Set compressor down only on a level surface capa-ble of safely supporting at least its weight and itsloading unit.

K. When moving the compressor by forklift truck, utilizefork pockets if provided. Otherwise, utilize pallet ifprovided. If neither fork pockets or pallet are pro-vided, then make sure compressor is secure and wellbalanced on forks before attempting to raise or trans-port it any significant distance.

L. Make sure forklift truck forks are fully engaged andtipped back prior to lifting or transporting the com-pressor.

M. Forklift no higher than necessary to clear obstaclesat floor level and transport and corner at minimumpractical speeds.

N. Make sure pallet-mounted compressors are firmlybolted or otherwise secured to the pallet prior toattempting to forklift or transport them. NEVERattempt to forklift a compressor that is not secured toits pallet, as uneven floors or sudden stops maycause the compressor to tumble off, possibly causingserious injury or property damage in the process.

1.10 EntrapmentA. If the compressor enclosure, if any, is large enough

to hold a man and if it is necessary to enter it to per-form service adjustments, inform other personnelbefore doing so, or else secure and tag the accessdoor in the open position to avoid the possibility ofothers closing and possibly latching the door withpersonnel inside.

B. Make sure all personnel are out of compressorbefore closing and latching enclosure doors.

DANGER

All field equipment must be tested for electro-static fields prior to servicing or making contact with the machine using the following or equiva-lent test equipment:

• 90 – 600 VAC: Volt detector such as Fluke Model 1AC-A

• 600 – 7000 VAC: Voltage detector such as Fluke Networks Model C9970

It is the responsibility of each organization to provide/arrange training for all their associates expected to test for electrostatic fields.

Page 11: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 1: Safety

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 10

1.11 Implementation of lockout/tagout

The energy control procedure defines actions necessaryto lockout a power source of any machine to be repaired,serviced or set-up, where unexpected motion, or anelectrical or other energy source, would cause personalinjury or equipment damage. The power source on anymachine shall be locked out by each employee doing thework except when motion is necessary during setup,adjustment or trouble-shooting.

A. The established procedures for the application ofenergy control shall cover the following elements andactions and shall be initiated only by Authorized Per-sons and done in the following sequence:

1. Review the equipment or machine to be lockedand tagged out.

2. Alert operator and supervisor of which machineis to be worked on, and that power and utilitieswill be turned off.

3. Check to make certain no one is operating themachine before turning off the power.

4. Turn off the equipment using normal shutdownprocedure.

5. Disconnect the energy sources:

a. Air and hydraulic lines should be bled,drained and cleaned out. There should beno pressure in these lines or in the reser-voir tanks. Lockout or tag lines or valves.

b. Any mechanism under tension or pressure,such as springs, should be released andlocked out or tagged.

c. Block any load or machine part prior toworking under it.

d. Electrical circuits should be checked withcalibrated electrical testing equipment andstored energy and electrical capacitorsshould be safely discharged.

6. Lockout and/or Tagout each energy source usingthe proper energy isolating devices and tags.Place lockout hasp and padlock or tag at thepoint of power disconnect where lockout isrequired by each person performing work. Each

person shall be provided with their own padlockand have possession of the only key. If morethan one person is working on a machine eachperson shall affix personal lock and tag using amulti-lock device.

7. Tagout devices shall be used only when powersources are not capable of being locked out byuse of padlocks and lockout hasp devices. Thename of the person affixing tag to power sourcemust be on tag along with date tag was placedon power source.

8. Release stored energy and bring the equipmentto a “zero mechanical state”.

9. Verify Isolation: Before work is started, testequipment to ensure power is disconnected.

B. General Security

1. The lock shall be removed by the “Authorized”person who put the lock on the energy-isolatingdevice. No one other than the person/personsplacing padlocks and lockout hasps on powershall remove padlock and lockout hasps andrestore power. However, when the authorizedperson who applied the lock is unavailable toremove it his/her Supervisor may remove pad-lock/padlocks and lockout hasps and restorepower only if it is first:

a. verified that no person will be exposed todanger.

b. verified that the “Authorized” person whoapplied the device is not in the facility.

c. noted that all reasonable efforts to contactthe “Authorized” person have been madeto inform him or her that the lockout ortagout device has been removed.

d. ensured that the “Authorized” person isnotified of lock removal before returning towork.

2. Tagout System—Tags are warning devicesaffixed at points of power disconnect and are notto be removed by anyone other that the personplacing tag on power lockout. Tags shall neverbe by-passed, ignored, or otherwise defeated.

Page 12: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

1: Safety LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0511 Subject to EAR, ECCN EAR99 and related export control restrictions.

1.12 Safety warningsThe following special instructions apply to VSD packagesprovided with electronic adjustable speed motor drives.These cautions that apply to VSD operation.

WARNING

Ground the unit following the instructions in this manual. Ungrounded units may cause electric shock and/or fire. The variable speed drive has a large capacitive leakage current during opera-tion, which can cause enclosure parts to be above ground potential. Proper grounding, as described in this manual, is required. Failure to observe this precaution could result in death or severe injury.

WARNING

Before applying power to the variable speed drive, make sure that the front and cable covers are closed and fastened to prevent exposure to potential electrical fault conditions. Failure to observe this precaution could result in death or severe injury.

WARNING

Refer all drive service to trained technicians. This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of this type of equipment and the haz-ards involved and in accordance with published service manuals. Failure to observe this precau-tion could result in death or severe injury.

WARNING

Line terminals (L1, L2, L3), motor terminals (U, V, W) and the DC link/brake resistor terminals (-/+) are live when the drive is connected to power, even if the motor is not running. Contact with this voltage is extremely dangerous and may cause death or severe injury.

WARNING

Before opening the variable speed drive covers:

• Disconnect all power to the variable speed drive.

• Wait a minimum of 5 (five) minutes after all the lights on the keypad are off.Wait a min-imum of 15 minutes after all the lights on the keypad are off. This allows time for the DC bus capacitors to discharge.

• A hazard voltage may still remain in the DC bus capacitors even if the power has been turned off. Confirm that the capacitors have fully discharged by measuring their voltage using a multimeter set to measure DC voltage. Failure to follow the above precautions may cause death or severe injury.

CAUTION

Do not perform any megger or voltage withstand tests on any part of the variable speed drive or its components. Improper testing may result in damage. Prior to any tests or measurements of the motor or the motor cable, disconnect the motor cable at the variable speed drive output terminals (U, V, W) to avoid damaging the vari-able speed drive during motor or cable testing.

CAUTION

Do not touch any components on the circuit boards. Static voltage discharge may damage the components.

Page 13: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 1: Safety

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 12

1.13 Safety decals

CAUTION

Install the variable speed drive in a well venti-lated room that is not subject to temperature extremes, high humidity, or condensation, and avoid locations that are directly exposed to sun-light, or have high concentrations of dust, corro-sive gas, explosive gas, inflammable gas, grinding fluid mist, etc. Improper installation may result in a fire hazard.

CAUTION

Make sure that no power correction capacitors are connected to the variable speed drive output or the motor terminals to prevent variable speed drive malfunction and potential damage.

CAUTION

Make sure that the variable speed drive output terminals (U, V, W) are not connected to the util-ity line power as severe damage to the VSD may occur.

NOTE

Interior electrical wiring is performed at the fac-tory. Required customer wiring is minimal, but should be done by a qualified electrician in com-pliance with OSHA, National Electrical Code, and/or any other applicable State, Federal, and local electrical codes concerning isolation switches, fused disconnects, etc. Sullair pro-vides a wiring diagram for use by the installer.

NOTE

Customer must provide electrical supply power disconnect within sight of machine.

WARNING

Auto start hazard

This machine is equipped with an auto start sequence that will start the unit when power is restored after a power failure or as part of automatic operation, which can result in serious injury or death.

Do not attempt to make any adjustments or per-form any maintenance on this machine without disconnecting both main line and control circuit electrical power and follow all of your company’s prescribed safety practices for electrical equip-ment.

Page 14: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

1: Safety LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

Notes:

02250231-030 R0513 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 15: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 2

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 2: Description

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 14

Description2.1 IntroductionYour new Sullair flood-lubricated rotary screw air com-pressor will provide you with a unique experience inimproved reliability and simplified maintenance. Com-pared to other types of compressors, the Sullair rotaryscrew is unique in mechanical reliability, with “No Wear”and “No Inspection” required of the working parts withinthe compressor air end. Read Section 7: Maintenance onpage 70 to see how surprisingly easy it is to keep your aircompressor in top operating condition.

2.2 Description of componentsRefer to Figure 2-1. The components and assemblies ofthe air compressor are clearly shown. The completepackage includes compressor, electric motor, starter,compressor inlet system, compressor discharge system,compressor lubrication and cooling system, capacity con-trol system, controller, aftercooler, a water separator anddrain, all mounted on a heavy gauge steel frame.

On air-cooled models, a fan draws air into the enclosureover the fan and main motors through the combinedaftercooler and fluid cooler thereby removing the com-pression heat from the compressed air and the coolingfluid, and forces it out the top of the machine.

On water-cooled models, a shell and tube heatexchanger is mounted on the compressor frame. Fluid ispiped into the heat exchanger where compression heat isremoved from the fluid. Another similar heat exchangercools the compressed air.

Both air-cooled and water-cooled versions have easilyaccessible items such as the fluid filter, air/oil separatorand control valves. The inlet air filter is also easily acces-sible for servicing.

2.3 Sullair air end, functional description

Sullair air compressors feature the Sullair compressor airend, a single-stage, positive displacement, flood lubri-

cated-type compressor. This air end provides continuouscompression to meet your needs.

Sullair compressors are factory-filled with Sullube® lubri-cant. For more information on fluid fill, consult Section3.4: Lubrication change recommendations and mainte-nance, fluid on page 25.

Fluid is injected into the compressor air end hoses andmixes directly with the air as the rotors turn, compressingthe air. The fluid flow has three basic functions:

• As coolant, it controls the rise of air temperaturenormally associated with the heat of compression.

• Seals the clearance paths between the rotorsand the stator and also between the rotorsthemselves.

• Acts as a lubricating film between the rotorsallowing one rotor to directly drive the other,which is an idler.

After the air/fluid mixture is discharged from the compres-sor air end, the fluid is separated from the air. At thistime, the air flows through an aftercooler and separatorthen to your service line while the fluid is being cooled inpreparation for reinjection.

NOTE

With a Sullair compressor, there is no mainte-nance or inspection of the internal parts of the compressor air end permitted in accordance with the terms of the warranty.

WARRANTY NOTICE

Mixing of other lubricants within the compressor unit will void all warranties.

Page 16: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

2: Description LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0515 Subject to EAR, ECCN EAR99 and related export control restrictions.

Figure 2-1: LS90 and LS110 overall component layout

1. Compressor air end 8. Moisture separator

2. Motor 9. Fluid filter

3. Oil cooler 10. Fluid fill

4. Electrical enclosure 11. Sight glass

5. E-Stop button 12. Separator tank

6. Controller 13. Air inlet filter

7. Aftercooler 14. Canopy vent fan

Air-cooled models

Water-cooled models

Page 17: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 2: Description

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 16

2.4 Compressor cooling and lubrication system, functional description

Refer to Figure 2-2. The cooling and lubrication system(air-cooled version) consists of a fan, fan motor, radiator-type aftercooler/fluid cooler, full flow fluid filter, thermalvalve, and interconnecting hoses. For water-cooled mod-els, two shell and tube heat exchangers are substitutedfor the radiator-type cooler listed above. The pressure inthe separator/sump tank causes fluid flow by forcing thefluid from the high pressure area of the separator/sumptank to an area of lower pressure in the compressor unit.

Fluid flows from the bottom of the separator/sump tank tothe thermal valve. The thermal valve is fully open when thefluid temperature is below 185°F (85°C) [210°F (99°C) forpressures rated above 150 psig]. The fluid passes throughthe thermal valve, the main filter and directly to the com-

pressor unit where it lubricates, cools and seals the rotorsand the compression chamber.

As the discharge temperature rises above 185°F (85 °C),due to the heat of compression, the thermal valve beginsto adjust and a portion of the fluid then flows through thecooler. From the cooler the fluid flows to the fluid filterand then on to the compressor unit.

A portion of the fluid flowing to the compressor is routedto the anti-friction bearings which support the rotorsinside the compressor unit.

The fluid filter has a replacement element and an integral pres-sure bypass valve. Refer to Section 3.4: Lubrication changerecommendations and maintenance, fluid on page 25.

Water-cooled models have a water pressure switch toprevent operation with inadequate water pressure.

Figure 2-2: LS90 and LS110 cooling / lubrication and discharge system

1. Compressor air end 4. Oil cooler

2. Separator tank 5. Fluid filter

3. Aftercooler 6. Moisture separator

Page 18: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

2: Description LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0517 Subject to EAR, ECCN EAR99 and related export control restrictions.

2.5 Compressor discharge system, functional description

Refer to Figure 2-2. The compressor unit discharges thecompressed air/fluid mixture into the combination sep-arator/sump tank.

The separator/sump has three basic functions:

• It acts as a primary fluid separator.

• Serves as the compressor fluid sump.

• Houses the final fluid separator.

The compressed air/fluid mixture enters the separator/sump tank and flows through an internal baffle system.The direction of movement is changed and its velocitysignificantly reduced, thus causing large droplets of fluidto form and fall to the bottom of the separator/sump tank.The fractional percentage of fluid remaining in the com-pressed air collects on the surface of the separator ele-ment as the compressed air flows through the separator.A return line (or scavenge tube) leads from the dry side ofthe separator/sump tank to a medium pressure region ofthe compressor unit. Fluid collecting on the bottom of theseparator is returned to the compressor by a pressuredifferential between the separator/sump and the com-pressor. A visual sight glass is located on the return lineto observe this fluid flow. There is also an orifice in thisreturn line (protected by a strainer) to assure proper flow.A message on the controller indicates if abnormal pres-sure drop through the separator develops. Refer to Sec-tion 3.4: Lubrication change recommendations andmaintenance, fluid on page 25.

A minimum pressure/check valve, located downstreamfrom the separator, assures a minimum separator/sumppressure of 50 psig (3.4 bar) during loaded conditions.This pressure is necessary for proper air/fluid separationand proper fluid circulation.

A terminal check valve is incorporated into the minimumpressure/check valve to prevent compressed air in theservice line from bleeding back into the separator/sumpon shutdown and during operation of the compressor inan unloaded condition.

A pressure relief valve (located on the wet side of theseparator) is set to open if the separator/sump tank pres-sure exceeds the separator/sump tank rating. The con-troller will shut down the compressor if the dischargetemperature reaches 235°F (113°C).

Fluid is added to the separator/sump tank via a cappedfluid filler opening, placed low on the tank to preventoverfilling of the separator/sump tank. A sight glassenables the operator to visually monitor the separator/sump tank fluid level.

2.6 Control system, functional descriptionRefer to Figure 2-3. The purpose of the compressor con-trol system is to regulate the amount of air being com-pressed to match the amount of compressed air beingused. The capacity control system consists of a solenoidvalve, regulator valve and an inlet valve. The functionaldescription of the control system is described below infour distinct phases of operation. For explanatory pur-poses, this description will apply to a compressor with anoperating range of 110 to 120 psig (7.6 to 8.3 bar). Acompressor with any other pressure range would operatein the same manner except stated pressures.

Start mode—0 to 50 psig (0 to 3.4 bar)When the controller Start button is depressed, the sepa-rator/sump tank pressure will quickly rise from 0 to50 psig (0 to 3.4 bar). The compressor initially startsunloaded with the solenoid valve open and the inlet valveclosed. It then switches to full load when full rpm hasbeen achieved. During this period, the solenoid valve isclosed, the inlet valve is fully open and the compressorpumps at full rated capacity. The rising compressor airpressure is isolated from the service line in this phase bythe minimum pressure valve set at approximately 50 psig(3.4 bar).

Full load mode—50 to 110 psig (3.4 to 7.6 bar)When the compressed air pressure rises above 50 psig(3.4 bar), the minimum pressure valve opens allowingcompressed air to flow into the service line. From thispoint on, the line air pressure is continually monitored bythe controller. The solenoid valve remains closed duringthis phase. The inlet valve is in the fully open position aslong as the compressor is running at 110 psig (7.6 bar) orbelow.

WARNING

Do not remove caps, plugs, and/or other com-ponents when compressor is running or pressur-ized. Stop compressor and relieve all internal pressure before doing so.

Page 19: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 2: Description

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 18

Modulating mode—110 to 120 psig (7.6 to 8.3 bar) [LS90, LS110]If less than the rated capacity of compressed air is beingused, the service line pressure will rise above 110 psig(7.6 bar). The pressure regulator valve gradually opens,directing air pressure to the inlet control valve, reducing airentering the compressor until it matches the amount of airbeing used. The control system functions continually in thismanner between the limits of 110 to 120 psig (7.6 to 8.3 bar)in response to varying demands from the service line. Theintegrated inlet valve has an orifice which vents a smallamount of air to the compressor inlet when the pressureregulator controls the inlet control valve. The orifice alsobleeds any accumulated moisture from the control lines.

Modulating mode with spiral valve—110 to 116 psig (7.6 to 8.0 bar) [LS90S, LS110S]As air demand drops below rated capacity of the compres-sor, the line pressure will rise above 110 psig (7.6 bar). As aresult the electric spiral valve motor will gradually rotateopening the bypass ports. Excess air is then being returned

back internally to the suction end of the compressor unit. Atthis point the compressor is fully compressor only theamount of air which is being used. As air demand keepsdropping further, the spiral valve continues to open moreuntil all of the bypass ports are fully open. At this point, thespiral valve is in the fully open (minimum capacity) position.

The spiral valve provides modulation range from 100 to40%. This accomplished within a ±1 psig band of the setpressure. As pressure rises continues to rise after thespiral valve is in the min position, the unload setpoint of116 psig (8.0 bar) is reached. At this point the machinetransitions to the unload mode.

Unload mode—in excess of 120 psig (8.3 bar)When a relatively small amount or no air is being used,the service line pressure continues to rise. When itexceeds 120 psig (8.3 bar), the controller control systemde- energizes the solenoid valve allowing separator/sump tank air pressure to be supplied directly to closethe inlet valve. Simultaneously, the solenoid valve sends

Figure 2-3: LS90 and LS110 standard pneumatic control system

1. Air inlet 4. Pressure regulator valve

2. Blowdown valve 5. Strainer

3. Solenoid valve 6. Full load solenoid valve

Page 20: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

2: Description LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0519 Subject to EAR, ECCN EAR99 and related export control restrictions.

a pneumatic signal to the blowdown valve. The blow-down valve opens to the atmosphere, located in the com-pressor separator/sump tank, reducing the separator/sump tank pressure to approximately 25 psig (1.72 bar).The check valve in the air service line prevents line pres-sure from returning to the separator/sump tank.

When the line pressure drops to the low setting (cut-in pres-sure; usually 110 psig (7.6 bar) on low pressure (7.6 bar)compressors and 125 psig (8.6 bar) on high pressure(9 bar) compressors, 150 psig (10.3 bar) on (10 bar) com-pressors, 175 psig (12.1 bar) on (12 bar) compressors), thecontroller energizes the solenoid valve and allows the blow-down valve to close. The re- energized solenoid valve againprevents line pressure from reaching the inlet control valve.Should the pressure begin to rise, modulating control willresume as previously described.

Load / no load controlIf desired by the customer, the compressor can be set to oper-ate load/no load without modulating control. This control modeis often selected when a large amount of compressed air stor-age (air tank) is available. Using the controller keypad, selectModulate from the menu and set it to NO. On a machinerated for 110 psig (7.6 bar) the compressor will run in the fullload mode up to 110 psig (7.6 bar). If less than the ratedcapacity is required, pressure will rise above 110 psig (7.6 bar)and the controller will de- energize the solenoid valve, causingthe compressor to run in the unload mode. When the systempressure falls to 100 psig (6.9 bar), the controller energizes thesolenoid valve, causing the compressor to return to the full loadmode. The compressor will thus operate to keep the systempressure in the range of 100 – 110 psig (6.9 – 7.6 bar).

Automatic operationFor applications with varied periods of time when there are no airrequirements, the controller’s AUTOMATIC mode allows thecompressor to shutdown (time delayed) when no compressed airrequirement is present and restart as compressed air is needed.

2.7 Air inlet system, functional description

Refer to Figure 2-4. The compressor inlet system con-sists of a dry-type air filter, a restriction switch and an airinlet valve.

The restriction switch (located on the air filter) indicatesthe condition of the air filter by sending a message to thecontroller when maintenance is required.

The poppet-type modulating air inlet valve directly con-trols the amount of air intake to the compressor inresponse to the operation of the pressure regulator.Refer to Full load mode—50 to 110 psig (3.4 to 7.6 bar)

on page 17. The inlet valve also acts as a check valve,thus preventing reverse rotation when the compressor isshut down.

WARNING

“The Plastic Pipe Institute recommends againstthe use of thermoplastic pipe to transport com-pressed air or other compressed gases inexposed above ground locations, e.g. in exposedplant piping.”1

Sullube® should not be used with PVC piping sys-tems. It may affect the bond at cemented joints.Certain other plastic materials may also beaffected. 1Plastic Pipe Institute, Recommendation B. AdoptedJanuary 19, 1972.

Figure 2-4: Air inlet system

1. Air inlet filter

2. Air inlet

3. Compressor air end

Page 21: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 2: Description

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 20

2.8 Variable speed drive (VSD) components

The VSD, located in the machine’s electrical enclosure,works in concert with the controller to allow the compres-sor to match its output to the current demand of the sys-tem. The drive’s heat sink extends through the back ofthe enclosure, and its cooled by air flowing through thecompressor enclosure.

2.9 VSD control system, functional description

Refer to Figure 2-3. The controls consist of:

• a VSD

• a solenoid valve

• an inlet valve

Depending on the model, a compressor can be operatedat a setpoint pressure from 60 to 175 psig (4.1 to12.1 bar). The controller automatically sets the speedrange based on the selected pressure. (The compres-sor's operating range is on its nameplate.)

The following paragraphs apply to a compressor with a110 psig (7.6 bar) operating pressure and a 6 psi(0.4 bar) load delta setting.

Compressors with different pressure operating rangesperform in the same manner.

Start mode—0 to 50 psig (0 to 3.4 bar)Pressing the controller start button signals the VSD toaccelerate the motor to minimum speed. At the sametime, the solenoid valve is open and the inlet valveclosed. After a short delay, the solenoid valve is closed,

inlet valve opened and the motor accelerates to maxi-mum speed. The rising air pressure is isolated from theservice line by the minimum pressure valve set atapproximately 50 psig (3.4 bar).

Full load mode—50 to 110 psig (3.4 to 7.6 bar)When the compressed air pressure rises above 50 psig(3.4 bar) the minimum pressure valve opens allowingcompressed air to flow into to the service line. From thispoint on the controller monitors the line pressure whichcontrols the VSD. The solenoid valve remains closedwith the inlet valve fully open, running at 110 psig(7.6 bar) or lower.

VSD part load controlThe service line pressure increases to a value above110 psig (7.6 bar) if the demand is less than the com-pressor's rated capacity. In this condition, the VSD slowsthe motor's rpm which reduces the output to match thedemand. The drive continuously adjusts the motor's rpmto maintain a 110 psig (7.6 bar) line pressure.

Unload mode—in excess of 116 psig (8.0 bar)When there is no demand or it is at a minimal level, theservice line pressure continues to rise. When it exceeds116 psig (8.0 bar), or reaches a preset unload pressurevalue, the control system de-energizes the solenoid valveallowing separator/sump tank air pressure to be supplieddirectly which closes the inlet valve. The solenoid valvesimultaneously sends a pneumatic signal to the blowdown valve which opens to the atmosphere, and reducesthe separator/sump tank pressure. The check valve in theair service line prevents line pressure from back-flowingto the separator/sump tank. The compressor will shutdown after the programmed unload time setting expires.When the line pressure drops to the low pressure settingof 110 psig (7.6 bar) the controller starts the motor andenergizes the solenoid valve which closes the blowdownvalve. The re-energized solenoid valve prevents linepressure from reaching the inlet control valve, therebyallowing it to fully open, and the compressor suppliescompressed air to the system.

NOTE

The load delta default setting is 10 psi (0.7 bar). Sullair recommends a setting of 6 psi (0.4 bar) for the most efficient operation.

Page 22: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

2: Description LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

Notes:

02250231-030 R0521 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 23: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 3

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 3: Specifications

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 22

Specifications3.1 Tables of specifications—LS90 & LS110

Table 3-1: Models, powers, and weights—LS90 & LS110

Model

Nominal main motor power

Weight1

Air-cooled Water-cooled

EnclosedEnclosed w/

weather hood Open EnclosedEnclosed w/

weather hood Open

hp kw lb kg lb kg lb kg lb kg lb kg lb kg

LS90 125 90 5830 2650 5976 2717 5262 2387 5780 2627 5926 2694 5125 2325

LS90S 125 90 5954 2706 6100 2773 5386 2443 5904 2683 6050 2750 5249 2381

LS90V 125 90 5908 2685 6054 2752 5340 2422 5858 2663 6004 2729 5203 2360

LS110 150 110 6007 2730 6153 2797 5439 2467 5957 2708 6103 2774 5302 2405

LS110S 150 110 6161 2800 6307 2867 5593 2537 6111 2778 6257 2844 5456 2475

LS110V 150 110 6084 2765 6230 2832 5516 2502 6034 2743 6180 2809 5379 24401Weights based on typical model.

Table 3-2: Enclosures and dimensions—LS90 & LS110

Enclosure

Length Width Height

in mm in mm in mm

Enclosed (air- and water-cooled) 99 2509 69 1760 70 1773

Enclosed with optional weather hood(air- and water-cooled) 99 2509 69 1760 89 2258

Open (air- and water-cooled) 97 2470 68 1715 68 1722

Table 3-3: Compressor specifications—LS90 & LS110

Compressor Standard models

Type Rotary screw

Standard operating pressure 110 psig (7.6 bar) / 125 psig (9 bar) / 150 psig (10 bar) / 175 psig (12 bar)

Maximum ambient temperature1 115°F (46°C)

Minimum ambient temperature 40°F (4.4°C)

Cooling Pressurized fluid

Compressor fluid Sullair Sullube®, PristineFG™

Separator/sump capacity 9 gallons (34 liters)

Control 10" touchscreen1Special compressors are available for operation in higher ambient temperature.

Page 24: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: Specifications LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0523 Subject to EAR, ECCN EAR99 and related export control restrictions.

3.2 Lubrication guideRefer to Figure 3-1 for location of fluid fill port. For bestvalue and longest uninterrupted service, Sullair compres-sors are factory filled and tested with Sullube® lubricant.

If fluid change is required, follow Section 3.4: Lubricationchange recommendations and maintenance, fluid onpage 24.

Table 3-4: Motor specifications—LS90 & LS110

Motor Standard models

Size 125, 150 hp / 90, 110 kW

Type C-flanged, totally enclosed fan cooled, premium efficiency, three phase, 230/460V 60 Hz

Maximum ambient temperature 104°F (40°C)

Minimum ambient temperature 40°F (4.4°C)

Available options 575V 60 Hz

Starter Wye-delta or VSD

Speed—125, 150 hp (90, 110 kW) 1780 rpm (60 Hz)

Multi-frequency and voltage motors are used. The compressors must be used only with the specified electrical frequency and voltage.

WARRANTY NOTICE

Mixing of other lubricants within the compressor unit will void all warranties.

WARNING

“The Plastic Pipe Institute recommends againstthe use of thermoplastic pipe to transport com-pressed air or other compressed gases inexposed above ground locations, e.g. in exposedplant piping.”1

Sullube® should not be used with PVC piping sys-tems. It may affect the bond at cemented joints.Certain other plastic materials may also beaffected. 1Plastic Pipe Institute, Recommendation B. AdoptedJanuary 19, 1972.

WARNING

Maintenance of all other components is still rec-ommended as indicated in the User’s Manual.

Figure 3-1: Fluid fill location

1. Tank

2. Fluid fill port

3. Sight glass

4. Fluid drain hose

Page 25: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 3: Specifications

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 24

Do not mix different types of fluids. Contamination ofcompressor fluid with mineral oil or other fluids may leadto operational problems such as foaming, filter plugging,orifice or line plugging.

When ambient conditions exceed those noted or if condi-tions warrant use of extended life lubricants contact Sul-lair for recommendation.

3.3 Application guideSullair encourages the user to participate in a fluid analy-sis program with the fluid suppliers. This could result in afluid change interval differing from that stated in the man-ual. Contact your Sullair dealer for details

3.4 Lubrication change recommendations and maintenance, fluid

NOTE

Flush system when switching lubricant brands.

Lubricant Fluid change Fluid filter change Separator change

Sullube® (14.5 gal / 54.9 L) E G, C I, D

PristineFG™ (14.5 gal / 54.9 L) H, E G, C I, D

C—When measured pressure loss exceeds 20 psig (1.3 bar).

D—When measured pressure loss exceeds 10 psig (0.7 bar).

E—When required by fluid analysis or known contamination.

G—Every 2,000 hours.

H—Every 6,000 hours or once a year.

I—Every 8,000 hours or once a year.

Page 26: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

25Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.5 ID, air-cooled (enclosed)

02250231-211 R02

Page 27: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

26

3.5 ID, air-cooled (enclosed)

Drawing notes

1 ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR.

2A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED. THE COMPRESSOR FRAME MUST BE LEVELLED AND SECUREDBETWEEN THE FRAME AND THE FOUNDATION. NO PIPING LOADS ARE PERMITTED AT EXTERNAL CONNECTIONS.

3 ALL DIMENSIONS ARE ± .50" [12.7MM].

4 RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING.

5 ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER DIMENSIONS IN PARENTHESES.

Page 28: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

27Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.6 ID, air-cooled (enclosed with optional weather hood)

02250231-323 R02

Page 29: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

28

3.6 ID, air-cooled (enclosed with optional weather hood)

Drawing notes

1 ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR.

2A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED. THE COMPRESSOR FRAME MUST BE LEVELLED AND SECURED BETWEEN THE FRAME AND THE FOUNDATION. NO PIPING LOADS ARE PERMITTED AT EXTERNAL CONNECTIONS.

3 ALL DIMENSIONS ARE ± .50" [12.7MM].

4 RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING.

5 ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER DIMENSIONS IN PARENTHESES.

Page 30: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

29Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.7 ID, air-cooled (open)

02250232-520 R02

Page 31: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

30

3.7 ID, air-cooled (open)

Drawing notes

1 ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR.

2A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED. THE COMPRESSOR FRAME MUST BE LEVELLED AND SECURED BETWEEN THE FRAME AND THE FOUNDATION. NO PIPING LOADS ARE PERMITTED AT EXTERNAL CONNECTIONS.

3 ALL DIMENSIONS ARE ± .50" [12.7MM].

4 RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING.

5 ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER DIMENSIONS IN PARENTHESES.

Page 32: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

31Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.8 ID, water-cooled (enclosed)

02250231-212 R01

Page 33: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

32

3.8 ID, water-cooled (enclosed)

Drawing notes

1 ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR.

2A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED. THE COMPRESSOR FRAME MUST BE LEVELLED AND SECURED BETWEEN THE FRAME AND THE FOUNDATION. NO PIPING LOADS ARE PERMITTED AT EXTERNAL CONNECTIONS.

3 ALL DIMENSIONS ARE ± .50" [12.7MM].

4 RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING.

5 ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER DIMENSIONS IN PARENTHESES.

Page 34: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

33Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.9 ID, water-cooled (enclosed with optional weather hood)

02250231-396 R01

Page 35: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

34

3.9 ID, water-cooled (enclosed with optional weather hood)

Drawing notes

1 ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR.

2A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED. THE COMPRESSOR FRAME MUST BE LEVELLED AND SECURED BETWEEN THE FRAME AND THE FOUNDATION. NO PIPING LOADS ARE PERMITTED AT EXTERNAL CONNECTIONS.

3 ALL DIMENSIONS ARE ± .50" [12.7MM].

4 RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING.

5 ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER DIMENSIONS IN PARENTHESES.

Page 36: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

35Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.10 ID, water-cooled (open)

02250232-521 R01

Page 37: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

36

3.10 ID, water-cooled (open)

Drawing notes

1 ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR.

2A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED. THE COMPRESSOR FRAME MUST BE LEVELLED AND SECURED BETWEEN THE FRAME AND THE FOUNDATION. NO PIPING LOADS ARE PERMITTED AT EXTERNAL CONNECTIONS.

3 ALL DIMENSIONS ARE ± .50" [12.7MM].

4 RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING.

5 ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER DIMENSIONS IN PARENTHESES.

Page 38: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

37Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.11 Piping & instrumentation, air-cooled (Wye-delta)

02250225-401 R02

Page 39: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

38

3.11 Piping & instrumentation, air-cooled (Wye-delta)

Components

Key Description Qty

01 FILTER,AIR INLET 1

02 VALVE, AIR INLET 1

03 MOTOR 1

04 COMPR 1

05 TANK, OIL SEP 1

06 ELEMENT, AIR/OIL SEP 1

07 VALVE, RELIEF 1

08 VALVE,MINIMUM PRESSURE 1

09 COOLER,OIL 1

10 COOLER, AIR 1

11 ELEMENT, THERMAL VLV 1

12 FILTER, COMPR OIL 1

13 SWITCH, VAC 1

14 PROBE, THERMISTER 2

15 TRANSDUCER, PRESS 4

16 VALVE, DRAIN 1

17 VALVE, SHUTTLE 2

18 VALVE, BACK PRESSURE 1

19 VALVE,SOLENOID 3WNO 2

20 VALVE, BLOWDOWN 1

21 ORIFICE 2

22 PLUG, SIGHT GLASS 1

23 DRAIN, SEP TANK 1

24 FILTER, SCAVENGE 1

25 SIGHTGLASS, SCAVENGE 1

26 DRAIN, ZERO LOSS 1

27 VALVE, BALL/STNR COMBO 1

28 HEATER, ZL 1

29 HEATER, SUMP 1

30 STRAINER 1

31 SEPARATOR, H2O 1

32 TEMPERATURE SWITCH (CE MACHINE ONLY) 1

Drawing notes

1SECTION BETWEEN LETTERED POINTS ARE TO BE REPLACED WITH CORRESPONDING OPTION PICTURED BELOW, AS REQUIRED BY FACE OF ORDER.

2OPTIONAL HEAT TRACE IS APPLIED ONLY TO CONTROL AND MOISTURE DRAIN LINES AND USED ONLY WITH STAINLESS STEEL TUBING.

3 PARTS VARY BY MODEL.

Component Description

P1 WET SUMP PRESSURE

P2 LINE PRESSURE

P3 INJECTION FLUID PRESSURE

P4 HIGH PRESSURE SIDE OF FLUID FILTER

PSW1 INLET FILTER VACUUM SWITCH

SOL1 LOAD/UNLOAD SOLENOID VALVE

SOL4 MEC/SEQUENCING/FULL LOAD SOLENOID VALVE (FULL VOLTAGE)

SOL5 COMBO DRAIN/JZL DRAIN SOLENOID VALVE

SOL7 EES SOLENOID VALVE (OPTIONAL)

T1 WET DISCHARGE TEMPERATURE

T2 DRY DISCHARGE TEMPERATURE

HTR1 SUMP HEATER

HTR3 TRAP HEATER

Key Description Qty

Page 40: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

39Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.12 Piping & instrumentation, air-cooled (VSD, Spiral Valve)

02250225-400 R04

Page 41: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

40

3.12 Piping & instrumentation, air-cooled (VSD, Spiral Valve)

Components

Key Description Qty

01 FILTER,AIR INLET 1

02 VALVE, AIR INLET 1

03 MOTOR 1

04 COMPR 1

05 TANK, OIL SEP 1

06 ELEMENT, AIR/OIL SEP 1

07 VALVE, RELIEF 1

08 VALVE,MINIMUM PRESSURE 1

09 COOLER,OIL 1

10 COOLER, AIR 1

11 ELEMENT, THERMAL VLV 1

12 FILTER, COMPR OIL 1

13 SWITCH, VAC 1

14 PROBE, THERMISTER 2

15 TRANSDUCER, PRESS 4

16 VALVE, DRAIN 1

17 VALVE,SOLENOID 3WNO 1

18 VALVE, BLOWDOWN 1

19 ORIFICE 2

20 PLUG, SIGHT GLASS 1

21 DRAIN, SEP TANK 1

22 FILTER, SCAVENGE 1

23 SIGHTGLASS, SCAVENGE 1

24 DRAIN, ZERO LOSS 1

25 VALVE, BALL/STNR COMBO 1

26 HEATER, ZL 1

27 VALVE, SPRIAL 1

28 HEATER, SUMP 1

29 STRAINER 1

30 SEPARATOR, H2O 1

31 TEMPERATURE SWITCH (CE MACHINE ONLY) 1

Drawing notes

1SECTION BETWEEN LETTERED POINTS ARE TO BE REPLACED WITH CORRESPONDING OPTION PICTURED BELOW, AS REQUIRED BY FACE OF ORDER.

2OPTIONAL HEAT TRACE IS APPLIED ONLY TO CONTROL AND MOISTURE DRAIN LINES AND USED ONLY WITH STAINLESS STEEL TUBING.

3 PARTS VARY BY MODEL.

4 VCC MODELS ONLY.

Component Description

P1 WET SUMP PRESSURE

P2 LINE PRESSURE

P3 INJECTION FLUID PRESSURE

P4 HIGH PRESSURE SIDE OF FLUID FILTER

PSW1 INLET FILTER VACUUM SWITCH

SOL1 LOAD/UNLOAD SOLENOID VALVE

SOL5 COMBO DRAIN/JZL DRAIN SOLENOID VALVE

SOL7 EES SOLENOID VALVE (OPTIONAL)

T1 WET DISCHARGE TEMPERATURE

T2 DRY DISCHARGE TEMPERATURE

HTR1 SUMP HEATER

HTR3 TRAP HEATER

Key Description Qty

Page 42: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

41Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.13 Piping & instrumentation, water-cooled (Wye-delta)

02250228-723 R02

Page 43: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

42

3.13 Piping & instrumentation, water-cooled (Wye-delta)

Components

Key Description Qty

01 FILTER, AIR INLET 1

02 VALVE, AIR INLET 1

03 MOTOR 1

04 COMPRESSOR 1

05 TANK, OIL SEP 1

06 ELEMENT, AIR/OIL SEP 1

07 VALVE, RELIEF 1

08 VALVE,MINIMUM PRESSURE 1

09 COOLER, AIR 1

10 COOLER,OIL 1

11 SEPARATOR, H2O 1

12 ELEMENT, THERMAL VLV 1

13 FILTER, COMPR OIL 1

14 SWITCH, VAC 1

15 PROBE, THERMISTER 2

16 TRANSDUCER, PRESSURE 4

17 VALVE, DRAIN 1

18 VALVE, SHUTTLE 1

19 VALVE, BACK PRESSURE 1

20 VALVE,SOLENOID 3WNO 2

21 VALVE, BLOWDOWN 1

22 DRAIN, SEP TANK 1

23 PLUG, SIGHTGLASS 1

24 FILTER, SCAVENGE 1

25 SIGHTGLASS, SCAVENGE 1

26 ORIFICE 2

27 SWITCH, PRESSURE 1

28 VALVE, BALL/STNR COMBO 1

29 DRAIN, ZERO LOSS 1

30 VALVE, WATER REG 1

31 HEATER, SEP TNK 1

32 HEATER, ZL 1

33 STRAINER 1

34 VALVE,SOLENOID WATER 1

35 TEMPERATURE SWITCH (CE MACHINES ONLY) 1

Drawing notes

1SECTION BETWEEN LETTERED POINTS ARE TO BE REPLACED WITH CORRESPONDING OPTION PICTURED BELOW, AS REQUIRED BY FACE OF ORDER.

2OPTIONAL HEAT TRACE IS APPLIED ONLY TO CONTROL AND MOISTURE DRAIN LINES AND USED ONLY WITH STAINLESS STEEL TUBING.

3 PART VARIES BY MODEL.

Component Description

P1 WET SUMP PRESSURE

P2 LINE PRESSURE

P3 INJECTION FLUID PRESSURE

P4 HIGH PRESSURE SIDE OF FLUID FILTER

PSW1 INLET FILTER VACUUM SWITCH

PSW2 WATER PRESSURE SWITCH

SOL1 LOAD/UNLOAD SOLENOID VALVE

SOL4 MEC/SEQUENCING/FULL LOAD SOLENOID VALVE (OPTIONAL)

SOL5 COMBO DRAIN/JZL DRAIN SOLENOID VALVE

SOL6 WATER SHUTOFF SOLENOID VALVE (OPTIONAL)

T1 WET DISCHARGE TEMPERATURE

T2 DRY DISCHARGE TEMPERATURE

HTR1 SUMP HEATER

HTR3 TRAP HEATER (JZL ONLY)

Key Description Qty

Page 44: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

43Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.14 Piping & instrumentation, water-cooled (VSD, Spiral Valve)

02250228-777 R03

Page 45: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

44

3.14 Piping & instrumentation, water-cooled (VSD, Spiral Valve)

Components

Key Description Qty

01 FILTER, AIR INLET 1

02 VALVE, AIR INLET 1

03 MOTOR 1

04 COMPRESSOR 1

05 TANK, OIL SEP 1

06 ELEMENT, AIR/OIL SEP 1

07 VALVE, RELIEF 1

08 VALVE,MINIMUM PRESSURE 1

09 COOLER, AIR 1

10 COOLER,OIL 1

11 SEPARATOR, H2O 1

12 ELEMENT, THERMAL VLV 1

13 FILTER, COMPR OIL 1

14 SWITCH, VAC 1

15 PROBE, THERMISTER 2

16 TRANSDUCER, PRESSURE 4

17 VALVE, DRAIN 1

18 VALVE, SPRIAL 1

19 VALVE,SOLENOID 3WNO 1

20 VALVE, BLOWDOWN 1

21 DRAIN, SEP TANK 1

22 PLUG, SIGHTGLASS 1

23 FILTER, SCAVENGE 1

24 SIGHTGLASS, SCAVENGE 1

25 ORIFICE 2

26 SWITCH, PRESSURE 1

27 VALVE, BALL/STNR COMBO 1

28 DRAIN, ZERO LOSS 1

29 VALVE, WATER REG 1

30 HEATER, SEP TNK 1

31 HEATER, ZL 1

32 STRAINER 1

33 VALVE,SOLENOID WATER 1

34 TEMPERATURE SWITCH (CE MACHINES ONLY) 1

Drawing notes

1SECTION BETWEEN LETTERED POINTS ARE TO BE REPLACED WITH CORRESPONDING OPTION PICTURED BELOW, AS REQUIRED BY FACE OF ORDER.

2OPTIONAL HEAT TRACE IS APPLIED ONLY TO CONTROL AND MOISTURE DRAIN LINES AND USED ONLY WITH STAINLESS STEEL TUBING.

3 PART VARIES BY MODEL.

4 VCC MODELS ONLY.

Component Description

P1 WET SUMP PRESSURE

P2 LINE PRESSURE

P3 INJECTION FLUID PRESSURE

P4 HIGH PRESSURE SIDE OF FLUID FILTER

PSW1 INLET FILTER VACUUM SWITCH

PSW2 WATER PRESSURE SWITCH

SOL1 LOAD/UNLOAD SOLENOID VALVE

SOL5 COMBO DRAIN/JZL DRAIN SOLENOID VALVE

SOL6 WATER SHUTOFF SOLENOID VALVE (OPTIONAL)

T1 WET DISCHARGE TEMPERATURE

T2 DRY DISCHARGE TEMPERATURE

HTR1 SUMP HEATER

HTR3 TRAP HEATER (JZL ONLY)

Key Description Qty

Page 46: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

45Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.15 Wiring diagram (Wye-delta, Spiral Valve)

02250227-884 R09 (sh1)

Page 47: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

46

3.15 Wiring diagram (Wye-delta, Spiral Valve)

02250227-884 R09 (sh2)

Page 48: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

3.15 Wiring diagram (Wye-delta, Spiral Valve)

02250231-030 R05

47Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

Transformer Connections Transformer Fuse Chart

Wiring

Wire Color Code

Drawing notes

1 CUSTOMER TO FURNISH FUSED OR CIRCUIT BREAKER DISCONNECT PER LOCAL CODES

2 REMOVE JUMPER FOR AUXILIARY E-STOP STRING DEVICES

3 BELDEN TYPE 9842 4 COND. 2 TWISTED PAIR W/ SHIELD OR EQUIVALENT. TO MATCHING TERMINALS ON NEXT COMPRESSOR FOR SEQUENCING

4 SEE TRANSFORMER CONNECTION TABLE FOR PROPER VOLTAGE CONNECTION. TRANSFORMER FUSING ON CLIPS LOCATED ON TRANSFORMER X1/XF INTERNALLY JUMPERED. SEE TRANSFORMER FUSE CHART FOR SIZING.

5 REFER TO SEQUENCING AND PROTOCOL MANUAL

6 SEE WIRING CHART FOR POWER AND MOTOR WIRING SIZE

12 FAN OPTIONAL: NOT FURNISHED ON WATER COOLED WITHOUT CANOPY

13 SET SWITCHES ON SVDR: SW1 = 0; SW2 = 4; SW3 = ALL TO ‘ON’ POSITION

14 2M FAN MOTOR CAN BE WIRED WITH OPTION 1 OR OPTION 2.

Primary Secondary volts

Volts Taps XF-X2 XF-X3 XF-X4

208 H1-H2 85 100 110

220 H1-H2 91 110 120

230 H1-H2 95 115 125

240 H1-H2 99 120 130

380 H1-H3 91 110 120

400 H1-H3 95 115 125

416 H1-H3 99 120 130

440 H1-H4 91 110 120

460 H1-H4 95 115 125

480 H1-H4 99 120 130

500 H1-H5 85 100 110

550 H1-H5 91 110 120

575 H1-H5 95 115 125

600 H1-H5 99 120 130

Voltage Primary Fuses Secondary Fuse

460 3A 7A

575 3A 7A

HP

Power wiring size75 deg rated wire

Motor wiring sizeGGC cable

460V 575V 460V 575V

125 1/0 1/0 4 AWG 4 AWG

150 1/0 1/0 2 AWG 4 AWG

200 2/0 2/0 1/0 1/0

3-PHASE LINE POWER BLACK (BLK)

110 / 120 VAC LINE RED

AC NEUTRAL WHITE (WHT)

DC CONTROL BLUE (BLU)

GROUND CONDUCTOR GREEN / YELLOW (GRN / YLW)

SEPARATELY SUPPLIED ORANGE (ORG)

Page 49: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

Notes:

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

48

Page 50: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

02250231-030 R05

49Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

3.16 Wiring diagram (VSD)

02250227-885 R09 (sh1)

Page 51: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User M

anual3: Specifications

02250231-030 R05

Subject to EAR, EC

CN

EAR99 and related export control restrictions.

50

3.16 Wiring diagram (VSD)

02250227-885 R09 (sh2)

Page 52: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

3: SpecificationsLS90, LS90S, LS90V, LS110, LS110S, LS110V U

ser Manual

3.16 Wiring diagram (VSD)

02250231-030 R05

51Subject to EAR

, ECC

N EAR

99 and related export control restrictions.

Connections

Transformer Fuse Chart

Wire Color Code

Drawing notes

1 CUSTOMER TO FURNISH FUSED OR CIRCUIT BREAKER DISCONNECT PER LOCAL CODES

2 REMOVE JUMPER FOR AUXILIARY E-STOP STRING DEVICES

3 BELDEN TYPE 9842 4 COND. 2 TWISTED PAIR W/ SHIELD OR EQUIVALENT. TO MATCHING TERMINALS ON NEXT COMPRESSOR FOR SEQUENCING

4 SEE TRANSFORMER CONNECTION TABLE FOR PROPER VOLTAGE CONNECTION. TRANSFORMER FUSING ON CLIPS LOCATED ON TRANSFORMER X1/XF INTERNALLY JUMPERED. SEE TRANSFORMER FUSE CHART FOR SIZING.

5 REFER TO SEQUENCING AND PROTOCOL MANUAL

6 SEE WIRING CHART FOR POWER AND MOTOR WIRING SIZE ON STARTER DOOR DECAL

12 FAN OPTIONAL: NOT FURNISHED ON WATER COOLED WITHOUT CANOPY

13 2M FAN MOTOR CAN BE WIRED WITH OPTION 1 OR OPTION 2.

Primary Secondary volts

Volts Taps XF-X2 XF-X3 XF-X4

208 H1-H2 85 100 110

220 H1-H2 91 110 120

230 H1-H2 95 115 125

240 H1-H2 99 120 130

380 H1-H3 91 110 120

400 H1-H3 95 115 125

416 H1-H3 99 120 130

440 H1-H4 91 110 120

460 H1-H4 95 115 125

480 H1-H4 99 120 130

500 H1-H5 85 100 110

550 H1-H5 91 110 120

575 H1-H5 95 115 125

600 H1-H5 99 120 130

Voltage Primary Fuses Secondary Fuse

460 2A 5A

575 2A 5A

3-PHASE LINE POWER BLACK (BLK)

110 / 120 VAC LINE RED

AC NEUTRAL WHITE (WHT)

DC CONTROL BLUE (BLU)

GROUND CONDUCTOR GREEN / YELLOW (GRN / YLW)

SEPARATELY SUPPLIED ORANGE (ORG)

Page 53: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 4

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 4: Installation

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 52

Installation4.1 Mounting of compressor A suitable foundation or fabricated support must beestablished to support the compressor. It should be rigidenough to keep the compressor frame level and maintainalignment of the compressor and motor. Tie-down boltsof sufficient size must be used to provide uniform contactbetween the foundation and the compressor frame.Materials such as rubber can be used to provide uniformcontact between the foundation and compressor frame.

Piping loads must be eliminated through the use of flexconnectors or other systems which prevent piping loadsfrom being transmitted to the compressor.

Special consideration should be made to meet nationaland local electrical codes for the required space aroundand in front of the electrical panel. Lighting should be pro-vided for future service requirements.

Accessibility for fork lift trucks, overhead cranes andmaintenance vehicles should be given careful consider-ation in order to provide any maintenance that may berequired. Adequate space around the unit should be pro-vided for access to all components of the compressor.

Softer surfaces in walls or ceilings will absorb sound andminimize ambient noise levels. Harder, reflective sur-faces will increase ambient noise levels.

Water-cooled compressors must have provisions forcooling water supply and drainage available.

4.2 Ventilation & cooling

4.2.1 Air-cooled compressorsAn area with adequate space must be provided for thecompressor and its components. Air-cooled compressors

require a minimum of 4 feet (1.25 meters) around theperimeter of the compressor.

The location should be free from standing water andallow access to clean air that is free from exhaust andpaint fumes, dust, metal filings or caustic chemicals.

Cooling air should be removed from the area in order toprevent the re-introduction of heated exhaust air backinto the compressor’s cooling system.

Reduced headroom above the compressor will requirethat cooling air be either ducted or in some way deflectedaway from the compressor. Inadequate ventilation willresult in higher ambient operating temperatures.

4.2.2 Water-cooled compressors Adequate cooling water flow must be supplied to water-cooled compressors. Water delivery must be verified toassure constant delivery of the volumes outlined inTable 4-1: Water flow requirements. The cleaning of pip-ing and water coolers is the customer’s responsibility.Inspect all piping for deposits and clean as necessary.Refer to Section 4.2.5: Water quality recommendationson page 53. The figures shown are for full-load operationutilizing an aftercooler. Cooler water will reduce water-flow requirements and warmer water will increase water-flow requirements.

Water piping to and from the compressor unit must besized to match compressor connection size. Isolationvalves with side drains should be installed on both inputand return lines. Input water should have a 2 mm strainerinstalled in-line.

Water quality is critical to proper cooling of the compres-sor. Excessive build-up of lime, scale or other deposits

NOTE

Ambient temperatures above 104°F (40°C) require that the high ambient option is specified for the compressor.

NOTE

Systems that employ both a conventional recip-rocating compressor and a screw-type axial compressor must be isolated from each other by use of a common receiver tank. Individual air-lines from each compressor should be piped to the common receiver tank.

Page 54: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

4: Installation LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0553 Subject to EAR, ECCN EAR99 and related export control restrictions.

can restrict the flow of water to the compressor. Thesedeposits act as a thermal insulator and reduce the effi-ciency of the water cooler.

The cleaning of piping and water coolers is the cus-tomer’s responsibility. Inspect all piping for deposits andclean as necessary. Refer to Section 4.2.5: Water qualityrecommendations on page 53.

Table 4-2: Ventilation requirements indicates the mini-mum ventilation requirements necessary to keep thecompressor running at its normal operating temperature.The fan air requirement is the amount of air, which mustflow through the compressor for proper ventilation. Theheat rejection requirement is the amount of heat that isradiated by the compressor. This heat must be removedto assure a normal operating temperature. With air-cooled compressors it is possible to use this heat forspace heating, providing additional pressure drop acrossthe fan does not exceed 0.2 in H2O. Consult a Sullairoffice for assistance in utilizing this heat. If ductwork isadded, the high static fan option is required.

Do not install a water-cooled or an air-cooled/after-cooled compressor where it will be exposed to tempera-tures less than 32°F (0°C). Consult factory for machineoperation in ambient temperature less than 32°F (0°C).

If machine is equipped with water regulating valve, usethe water regulating valve to adjust compressor tempera-

ture to maintain a minimum of 185°F (85°C) [210°F (99°C)for pressures rated above 150 psig].

Temperature and pressure gauges should be installed inthe water piping for use in troubleshooting of the watersystem. Water pressure should ideally be between 25and 75 psig (1.7 and 5.2 bar) but must not be above145 psi (10 bar).

4.2.3 Water system ventingVent the system upon installation or after draining thesystem on start-up:

1. Open the water valve(s) allowing water toflow to the system.

2. Open the vent cocks (located on top of theaftercooler and the lubricant cooler) andallow all air to escape from the system.When water is observed at the vent cocks,close them.

The system is now vented.

4.2.4 Draining the water systemIf the system needs to drained completely, follow thesteps outlined below:

1. At the rear of the unit. Disconnect both theinlets and discharge water lines.

2. Remove the drain plugs located at the bot-tom of the aftercooler and lubricant cooler.

3. Allow the system to drain completely.

4.2.5 Water quality recommendationsWater quality considerations are crucial to the effectiveoperation of a water-cooled compressor and yet are themost often ignored. Premature failure of components canoften be traced to a reduction in heat-transfer rate thathas resulted from a reduced flow rate due to scale build-up in water-cooling lines or the coolers themselves.

Table 4-1: Water flow requirements

Nominal main motor power

Water temperature andrequired water flow1

70°F (21°C) 80°F (27°C)

gal/min L/min gal/min L/min

125 hp (90 kW) 16 68 25 95

150 hp (110 kW) 22 83 30 1141 Water pressure should be maintained between 25 and 75 psig (1.7 and 5.2 bar), but not to exceed 145 psig (10 bar).

Table 4-2: Ventilation requirements

Cooling typeNominal main motor power

Fan airVentilating air—heat rejection

Cooling water—heat rejection

cfm m3/h BTU/h kcal/h BTU/h kcal/h

Air-cooled with aftercooler125 hp (90 kW) 11,800 20,048 375,300 94,574 — —

150 hp (110 kW) 11,800 20,048 450,360 113,489 — —

Water-cooled125 hp (90 kW) 2,845 4,834 80,400 20,260 375,300 94,574

150 hp (110 kW) 2,845 4,834 80,400 20,260 450,360 113,489

Page 55: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 4: Installation

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 54

To ensure maximum life expectancy and best perfor-mance of the compressor cooling system, refer toTable 4-3: Water tests.

4.2.5.1 ScaleScale is formed from calcium carbonate, which precipi-tates out of water. Calcium content tends to be higher inwater taken from wells than water taken from the surfaceof lakes. A higher pH value will also assist in the forma-tion of lime scale. In all cases calcium will form scalewhen water that has dissolved calcium is heated. It thenforms lime-scale on surfaces such as the inside of pipesand the tubing that comprises water coolers. Scale for-mation on the inside of pipes and inside of heat exchang-ers acts as a thermal insulator. This causes coolers to beless effective, and piping to have reduced water flow,making them less effective. Over time lime scale build-upcan reduce water flow by 80% or greater. This rendersthe cooling system ineffective and will damage the sys-tem. Scale can be controlled with water treatment.

4.2.5.2 CorrosionAs contrasted to lime scale build-up, corrosion eventuallycauses a reduction in the wall thickness of pipes. Highlevels of dissolved oxygen and low pH levels assist in thecreation of corrosive scale. A thin coating of lime scale isoften beneficial in helping to prevent corrosion from form-ing.

4.2.5.3 Biological and organic fouling (slime)The heightened temperatures of compressor coolingoperations help to reduce the likelihood that organic foul-

ing will become a major concern. In the event of an infes-tation, commercial chemical shock treatments areavailable to control any outbreaks.

4.2.6 Seawater-cooled units

Water cleanliness is critical for operation of the compres-sor. A strainer must be installed in the inlet piping of thewater system. It is also recommended that a solenoidvalve (normally closed) be installed into the water outletside of the compressor system. In addition, be aware thatcleaning of coolers as a result of fouling is a customerresponsibility.

Isolation valves with side drains should be installed onboth the inlet and outlet lines.

The recommended flow rate cannot be exceeded. An ori-fice plate must be installed in the pipe-work at least 3.3 ft(1 m) before the cooler. The orifice size must be calcu-lated to ensure that the maximum seawater flow rate can-not be exceeded. Without these precautions, theseawater flow rate through the cooler may be severaltimes the recommended maximum, which will lead torapid system failure.

Table 4-3: Water tests

Substances Test interval Acceptable concentration

Corrosivity hardness, pH, total dissolved solids, temperature at inlet, alkalinity

Monthly. If stable for 3 to 4 months, analyze quarterly. Langerlier index 0 to 1

Iron Monthly < 2 ppm

Sulphate Monthly < 50 ppm

Chloride Monthly < 50 ppm

Nitrate Monthly < 2 ppm

Silica Monthly < 100 ppm

Desolated oxygen Daily. If stable, analyze weekly. 0 ppm (as low as possible)

Oil & grease Monthly < 5 ppm

Ammonia Monthly < 1 ppm

NOTE

If seawater is to be used for cooling, optional copper-nickel coolers must be selected.

Page 56: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

4: Installation LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0555 Subject to EAR, ECCN EAR99 and related export control restrictions.

No oil cooler manufacturer can guarantee that its prod-ucts will have an indefinite life and for this reason, wesuggest that the cooling system be designed to minimizeany damage caused by oil cooler leaking. This can beachieved as follows:

• The oil pressure should be maintained at apressure higher than the seawater pressure. Inthe event of a leak occurring, the oil will be pre-vented from becoming contaminated.

• When the hydraulic system is not in use, thecoolers should be isolated from incoming sea-water under pressure.

• The seawater outlet pipe from the coolershould have an open run to waste piping.

4.3 Outdoor installation (sheltered)Compressor packages installed in locations where theywill be exposed to outside elements must be equippedwith a TEFC motor. Standard compressors have watertight controls that are NEMA 4 rated and are suitable forthis type of installation.

The compressor should be on a concrete pad, which isdesigned to drain water away from it. If the concrete padis sloped, then the compressor must be mounted so thatit is level. The base or skid must be fully supported whereit contacts the concrete pad.

A weatherhood option should be selected to preventdirect rain and snow from falling on the unit. If localweather conditions can be extreme such that direct rain

or snow may fall on the unit, it should be in a fullyenclosed room or building.

If installed under a shelter, air-cooled machines must bepositioned in a way that prevents air recirculation (i.e.,hot exhaust being allowed back to the system air inlet).

In installations that include more than one compressor,hot air exhaust should not be directed toward the freshair intake of the second unit or an air dryer.

A standard machine installed outside must not be startedor run if the ambient temperature in and around the com-pressor drops or may drop below 40°F (4.4°C).

For installation in a below freezing climate, a low ambientoption with heat tracing and a separator/sump tankheater must be installed.

4.4 Service air pipingReview carefully the total air system before installing anew compressor. Items to consider for the total air sys-tem include liquid carryover, pipe sizing, and the use ofan auxiliary receiver tank. The installation of a drip leg ormultiple drip legs, installation of a line filter(s) and theinstallation of isolation valve or valves. These consider-ations are important to ensure a safe and effective sys-tem. See Figure 4-1.

Seawater pressure

Orifice diameter for maximum seawater flow (or 58 US gal/min [220 L/min])

in mm

25 psi (1.7 bar) 1.15 29

35 psi (2.4 bar) 1.06 27

45 psi (3.1 bar) 1.00 25

55 psi (3.8 bar) .94 24

65 psi (4.5 bar) .90 23

75 psi (5.2 bar) .87 22

NOTE

Variable speed drive compressors are NEMA 12 rated and must not be installed outside or exposed to the elements.

NOTE

Discharged air contains a very small amount of compressor lubricating oil, and care should be taken to ensure that this oil would not interfere with downstream equipment. Downstream fil-ters and an air dryer can remove any carryover.

Page 57: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 4: Installation

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 56

4.4.1 Pipe sizing Pipe should be sized at least as large as the dischargeconnection of the compressor. Piping and fittings shouldall be suitably rated for the discharge pressure.

4.4.2 Use of auxiliary receiver tankAn auxiliary receiver tank should be used in cases wherelarge demand swings are expected. Isolation Valve(s) Ifisolation of the compressor from the service lines isrequired, isolation valves should be installed close to thedischarge of the compressor. They should be installedwith drip legs that drain sloping downward from the basein order to drain properly. Install a vent to the pipingdownstream of the compressor outlet connection.

When two compressors are operated in parallel, providean isolation valve and a drain trap for each compressorbefore the common receiver.

A built-in aftercooler reduces the discharge air tempera-ture below the dew point. For most ambient conditions,considerable water vapor is condensed. To remove thecondensation, each compressor with built-in aftercooleris supplied with a combination condensate separator/

WARNING

The use of plastic bowls on line filters and other plastic airline components without metal guards can be hazardous. Synthetic coolants or the additives used in mineral oils can alter their structural integrity and create hazardous condi-tions. Metal bowls should be used on any pres-surized system for safety concerns.

“The Plastic Pipe Institute recommends againstthe use of thermoplastic pipe to transport com-pressed air or other compressed gases inexposed above ground locations, e.g. inexposed plant piping.”1

Sullube® should not be used with PVC pipingsystems. It may affect the bond at cementedjoints. Certain other plastic materials may alsobe affected. 1Plastic Pipe Institute, Recommendation B. AdoptedJanuary 19, 1972.

Figure 4-1: Service air piping—typical installation

1. Sullair compressor 4. Sullair filter 7. Standard gate valve

2. Sullair dryer 5. Water leg drain valve A1. Customer connections

3. Shut-off gate valve 6. By-pass gate valve A2. Customer connections

Page 58: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

4: Installation LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0557 Subject to EAR, ECCN EAR99 and related export control restrictions.

trap. A drain line should be installed on the condensatedrain.

4.5 Coupling alignment checkNo coupling alignment is required.

4.6 Fluid level checkThe air compressor is shipped with the proper amount offluid installed. However, it is necessary to check the fluidlevel at the time of installation and during continued oper-ation of the compressor. The fluid level is to be checkedwhen the compressor is in the SHUT DOWN mode (fluidlevel may not be visible when operating), and by lookingat the sight glass on the separator/sump tank. To be ableto see the fluid level it may be necessary to start themachine and build the separator/sump tank pressure upto 10/20 psi and then shut down. Wait a few minutes tocheck oil level. If no fluid level is seen in the sight glassadd fluid to the center of the glass. Do not overfill in anycase. When a complete fluid change is performed, fill theseparator/sump tank to the maximum allowable fluidlevel, which is center of the sight glass.

4.7 Electrical preparationInterior electrical wiring is performed at the factory.Required customer wiring should be done by a qualifiedelectrician in compliance with OSHA, National ElectricCode and/or any applicable local electrical code concern-ing isolation switches, fused disconnects, etc. Sullair pro-vides a wiring diagram for use by the installer. Anelectrical check should be made to help assure that thefirst start-up will be trouble-free. The compressor and

drive should be properly grounded/earthed in accordancewith Local and National Code requirements.

Installation of this compressor must be in accordancewith recognized electrical codes and any local Health andSafety Codes.

Feeder cables should be sized by the customer/electricalcontractor to ensure that the circuit is balanced and notoverloaded by other electrical equipment. The length ofwiring from a suitable electrical feed point is critical asvoltage drops may impair the performance of the com-pressor.

Feeder cable connections to incoming terminals L1-L2-L3 should be tight and clean.

The applied voltage must be compatible with the motorand compressor data plate ratings.

1. Check incoming voltage. Be sure that theincoming voltage is the same voltage that thecompressor was wired for.

2. Check motor starter and overload heatersizes.

3. Check all electrical connections for tight-ness.

4.8 Motor rotation direction checkThese model compressors come standard with phasesequence monitoring. Main motor rotation directionchecks are not required at installation.

Fan motor rotation should be checked. It should rotatecounter-clockwise when viewing the fan motor from thebackside of the motor

NOTE

For low-volume systems that do not require an auxiliary separator/sump, compressor response time may need to be adjusted. Consult the Sul-lair Service Department for assistance.

DANGER

Lethal shock hazard inside. Disconnect all power at source before opening or servicing.

Page 59: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 4: Installation

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 58

.

Figure 4-2: Direct drive rotation

Figure 4-3: Gear drive rotation

Figure 4-4: Fan rotation

Page 60: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

4: Installation LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

Notes:

02250231-030 R0559 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 61: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 5

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 5: Operation

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 60

Operation5.1 IntroductionWhile Sullair has built into the LS Series package a com-prehensive array of controls and indicators to assure itsproper operation, the user should recognize and interpretreadings which call for service or indicate the onset of amalfunction. Before starting the unit, the user shouldbecome familiar with the controls and indicators—theirpurpose, location, and use.

5.2 Purpose of controlsIndicators and functions included in the LS compressorpackage, except for the controller, are listed in the follow-ing guide. For more information on the controller, seeSection 5: Controller.

Table 5-1: Controls and purposes

Control Purpose

Emergency stop button(E-stop)

Pushing in this button, found adjacent to the controller, cuts all AC outputs from the controller and de-energizes the starter. A fault message is displayed by the controller until the E-stop button is pulled out and the Stop button is pressed.

Thermal O/L resetMomentarily pushing this button, found on the starter’s thermal overload element housing, re-closes the starter’s contacts after a current overload takes place. Please be aware that the elements must be allowed to cool sufficiently before resetting.

Inlet valveThe inlet valve throttles the air flow to the compressor inlet, in order to match air supply to the demand.

Spiral Valve (optional)Internally bypasses and controls the air flow capacity of the compressor, in order to match air supply to the demand.

Pressure regulator (inlet valve)

Opens a pressure line between the sump and inlet valve piston allowing the inlet valve to regulate air delivery according to the air demand.

Solenoid valve #1Electrically actuated, 3-way valve which controls the flow of pneumatic logic signals. Used throughout package to open the blowdown valve and close the inlet valve.

Solenoid valve #2Electrically actuated 3-way valve, normally open to the control regulators. Closes to force the machine to full load operation as lead machine for sequencing.

Minimum pressure valveMaintains 50 psig (3.4 bar) in the receiver tank when the compressor is running loaded. Also incorporates a check valve, which prevents compressed air back-flow from the system when unloaded or shutdown.

Pressure relief valveVents the sump vessel to atmosphere before the compressed air pressure exceeds rated tank pressure. Its operation indicates fault with the controller operation unload pressure set too high or failure of solenoid valve #1.

Blowdown valve assembly Vents the sump vessel to atmosphere during unloading and shutdown.

Thermal mixing valve

Bypasses fluid flow around the cooler until the fluid reaches a temperature of 185°F (85°C) [210°F (99°C) for ≥ 150 psi (10.3 bar)]. Useful for fast warm-up during start. Maintains a minimum temperature during periods of low load or low ambient temperatures.

Sump sight glassIndicates level of lubricant in the sump. Located on the sump side, fluid level should be maintained at center of the sight glass with machine shut down.

Page 62: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

5: Operation LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0561 Subject to EAR, ECCN EAR99 and related export control restrictions.

5.3 Initial start-up procedureThe following procedure should be used to make the ini-tial start-up of the compressor.

1. Read the preceding pages of this manualthoroughly.

2. Check for correct rotation of fan motor (referto Section 4.8 on page 57).

3. Be sure that all preparations and checksdescribed in Section 4: Installation havebeen made.

4. Press the Start button.

5. Open the shut-off valve to the service line.

6. Check for possible leaks in piping.

7. Slowly close the shut-off valve to assureproper nameplate pressure unload setting iscorrect. The compressor will unload atnameplate pressure. If adjustments are nec-essary, see Section 7.10: Pressure regulatoradjustment on page 73.

8. Observe the operating temperature. Refer toSection 2.4 on page 16 for proper operatingtemperature range. If temperature exceedsthis range, the cooling system and installa-tion environment should be checked.

9. Open shut-off valve to the service line.

10. Reinspect the compressor for temperatureand leaks the following day.

5.4 Subsequent start-up procedureThe following procedure should be used to make subse-quent start-ups of the compressor.

1. Check that the proper level is visible in thefluid sight glass.

2. Press the Start button.

3. While the compressor is running, observethe instrument panel and maintenance indi-cators.

5.5 Shutdown procedureThe following procedure should be used to shut down thecompressor.

1. Press the Stop button.

Separator return line sight glasses

Indicate fluid flow in the separator return lines. Flow should be visible during full load operation; little to no flow during unloaded operation. Sluggish flow during full load operation indicates the need to clean the strainers fitted to the return lines.

Water pressure switchDe-energizes the starter, via the controller, if the water pressure falls below 10 psig (0.7 bar). This switch is not adjustable. Used on water-cooled packages only.

Drain valves Lubricant sump drain valve.

Table 5-1: Controls and purposes

Control Purpose

NOTE

Before initial start up check that fluid is at proper level in the sight glass. Grease motor per manu-facturer’s recommendations.

WARNING

The E-Stop (emergency stop switch) should be used only in the event of an emergency. Refrain from using the E-Stop to shut the machine down during normal operations or equipment damage can occur. All usage of the E-Stop is logged in per-manent memory for use by service technicians when troubleshooting a machine. Non-emergency use of E-Stop is considered equipment abuse and could void the manufacturer’s warranty.

Page 63: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 5

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 5: Controller

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 62

Controller5.1 Controller layout

Figure 5-1: Controller layout and button functions

Key Description Function

1 Start buttonPush to start the compressor. Can also be used to reset maintenance and warning messages while the compressor is running.

2 Stop buttonPush to stop the compressor. Can also be used to clear fault messages when the compressor is stopped.

Page 64: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

5: Controller LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0563 Subject to EAR, ECCN EAR99 and related export control restrictions.

3 Indicator LEDs

There are four status indicators that identify the current operational status of the machine:

• Power-On Indicator (Blue) – Lights when power isapplied to the controller. It will blink slowly to indicatethat Automatic Restart After Power Failure is enabled.

• Automatic or Manual Run Mode Indicator (Green) –Lights whenever the compressor is set to start and runautomatically. The light is constant whenever themotor is running. The light will blink slowly if the com-pressor motor is stopped while in Automatic Mode asa warning that the machine may restart at any time.The light may blink rapidly if a machine start is immi-nent.

• Maintenance or Warning Indicator (Amber) - Lightswhen recommended maintenance or service warningis issued. In most cases, the machine will continue tooperate normally.

• Fault Indicator (Red) - Lights when a compressor faulthas occurred. The light remains steady and the com-pressor remains inoperative until the fault condition iscorrected.

4 QR CodeRead the QR code with the camera on your smartphone or tablet to access user manuals on your device.

5 Touch screen displayDisplays operating parameters and compressor information. Provides interface between the user and the compressor controller.

6 Menu button Returns to the main menu screen.

7 USB PortUse this port to upload information to the STS controller using a flash drive.

8 Emergency Stop (E-stop) buttonUsed to stop the compressor immediately. The E-stop but-ton is logged as a fault and should only be used when essential.

Page 65: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 5: Controller

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 64

5.2 Home page

For a complete overview of the controller, see the SullairTouch Screen (STS) Controller User Manual (P/N02250241-178 R00) for more information.

The Analog/Digital Panel screen is the default screenfor the home page. This screen is divided into two mainsections:

• The status area at the top shows the load andrun times, starts and cycles, and messagerelated to the current status (state and mode).

• The gauge area below shows discharge tem-perature, discharge pressure, and sump pres-sure as analog gauges.

You can change the units of measure for pressure andtemperature on the User Preferences page (see Section5.4 on page 66).

You can access the User Preferences page by pressingthe main menu button in the lower left corner of thescreen, then selecting System Information, and thenselecting User Preferences. (See Section 5.5: Menuhierarchy on page 67 for the complete menu structure.)

Figure 5-2: Home page—Analog/Digital Panel screen (default)

1. Main menu button (red square)

Page 66: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

5: Controller LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0565 Subject to EAR, ECCN EAR99 and related export control restrictions.

5.3 Main Menu page

From the main menu, you can navigate to other pagesthat allow you to:

• View and change configuration settings

• View reports, charts, and graphs

• View fault and warning history

• View maintenance information

• Login in as an administrator

• And perform other administrative functions

To view the complete menu hierarchy, see Section 5.5on page 67.

You can reach the main menu by pressing the mainmenu (home) button on the home page, or by pressingthe back arrow from other menus until you return to themain menu.

• The back arrow always takes you back onepage.

• If you’re on the main menu page, the backarrow will return you to the home page.

• The main menu (home) button always takesyou back to the home page.

Figure 5-3: Main menu page

Page 67: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 5: Controller

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 66

5.4 User Preferences page

The following user interface options are available underUser Preferences:

• Pressure Units. The user can choose betweenPSI, BAR, and k/Pa as the unit of measure forpressure.

• Temperature Units. The user can choosebetween Fahrenheit (F) and Celsius (C) as theunit of measure for temperature.

• Language. The user can choose betweenEnglish, Spanish, French, Portuguese, Russianand Chinese for the display language.

• Note: The display language changesimmediately upon selection.

• Home Screen. The user can choose betweenAnalog/Digital Panel, Mimic Panel, or MultiGauge for the home page screen. See the Sul-lair Touch Screen (STS) Controller UserManual (P/N 02250241-178 R00) for moreinformation.

You can access the User Preferences page by selectingSystem Information from the main menu and thenselecting User Preferences.

Figure 5-4: User preferences page

Page 68: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

5: Controller LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0567 Subject to EAR, ECCN EAR99 and related export control restrictions.

5.5 Menu hierarchy

Figure 5-5: Sullair touch screen controller menu hierarchy

Page 69: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 5: Controller

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 68

5.6 AirLinx™ remote monitoring (optional)

Sullair AirLinx allows remote monitoring of your compres-sor. AirLinx provides access to all monitored compressorreadings—power, pressure, flow and more—24 hours aday, seven days a week, on any device that can load abrowser.

To sign up for an AirLinx account, please visit sullair.comor e-mail [email protected] for a digital sign-up form. Ifyou need connection assistance, please call 888-320-8332 or send an e-mail to [email protected].

5.6.1 Troubleshooting AirLinx communications

AirLinx consists of an antenna installed on the outside ofthe compressor's enclosure and an M70 modem installedinside the compressor's control cabinet. The LED lightson the modem indicate the current status of the compres-sor. The definitions of these lights are shown in Table 5-1, Table 5-2 and Table 5-3.

.Table 5-1: PWR LED definitions (LED #1, red/green)

Power status LED state

LMU off Off

U-boot Red solid

Kernel start Green solid

LMU on Red solid

Table 5-2: GPS LED definitions (LED #4, red/green)

GPS status LED state

U-boot Red solid

Kernel start Green solid

GPS off Off

GPS on Green slow blinking

GPS time sync Green fast blinking

GPS fix Green solid

Table 5-3: COMM LED definitions (LED #5, red/green)

Comm status LED state

Modem off Off

Comm on—searching Slow blinking

Network available Fast blinking

Registered (no inbound acknowledgement)

Alternates between solid and fast blink every one second

Page 70: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

5: Controller LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

Notes:

02250231-030 R0569 Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 71: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Section 7

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 7: Maintenance

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 70

Maintenance7.1 General

As you proceed in reading this section, it will be easy tosee that the Maintenance Program for the air compressoris quite simple. The use of the service indicators providedfor the fluid filter, air filter and fluid separator will alert youwhen service maintenance is required. When the control-ler display indicates service, maintenance for that spe-cific item is required. See instructions for each item inSection 7.6: Filter maintenance on page 71.

7.2 Daily operationPrior to starting the compressor, it is necessary to check thefluid level in the separator/sump tank. Should the level be low,simply add the necessary amount. If the addition of fluidbecomes too frequent, a simple problem has developedwhich is causing this excessive loss. See Section 7.14.2:

Troubleshooting guide on page 75 under “Excessive com-pressor fluid consumption” for a probable cause and remedy.

After a routine start has been made, observe the control-ler display and be sure it monitors the correct readingsfor their particular phase of operation. After the compres-sor has warmed up, it is recommended that a generalcheck on the overall compressor be made to assure thatthe compressor is running properly.

7.3 Maintenance after initial 50 hours of operation

After the initial 50 hours of operation, a few maintenancerequirements are needed to clean the system of any for-eign materials. Perform the following maintenance opera-tions to prevent unnecessary problems:

• Clean the return line strainer. Refer to the sumptank assembly section of the Parts Manual forlocation.

• Clean the return line orifice.

• Change fluid filter.

7.4 Maintenance every 2000 hoursAfter 2000 hours of normal operation, or at a minimumevery six months, it will be necessary to perform the fol-lowing:

• Clean the return line strainer. Refer to the sumptank assembly section of the Parts Manual forlocation.

• Replace the fluid filter element.

• Pull oil sample for analysis.

• Check air filter. Change if necessary.

7.5 Fluid maintenanceChange the separator element every 8000 hours or 1year, whichever comes first. Drain the separator/sumptank and change the compressor fluid using instructionsshown in Section 3.4: Lubrication change recommenda-tions and maintenance, fluid on page 24.

WARNING

Before any repairs are attempted, refer to Sec-tion 1: Safety before proceeding.

WARNING

High-pressure hazard!

• Do not remove caps, plugs, and/or other components when compressor is run-ning or pressurized. Stop compressor and relieve all internal pressure before doing so.

• Failure to comply could result in death or serious injury.

Page 72: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

7: Maintenance LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0571 Subject to EAR, ECCN EAR99 and related export control restrictions.

7.6 Filter maintenance

Refer to Figure 7-1. Replace your fluid filter elementunder any of the following conditions, whichever occursfirst:

• As indicated by the controller.

• Every fluid change.

7.6.1 Fluid filter element replacementRefer to Figure 7-1.

1. Using a strap wrench, remove the filter can-ister.

2. Remove and dispose of filter element.Observe all laws and regulations for filter dis-posal.

3. Clean gasket seating surface.

4. Apply a light film of fluid to the new gasketand hand tighten the new element until thegasket contact the seat.

5. Continue tightening the element and addi-tional ½ to ¾ turn.

6. Restart compressor and check for leaks.

7.7 Air filter maintenance

Refer to Figure 7-2. Air filter maintenance should be per-formed when indicated by the controller, or once a year,whichever comes first. If the filter needs to be replaced,order a replacement element. Below you will find proce-dures on how to replace the air filter element.

7.7.1 Air filter element replacement 1. Clean the air filter’s exterior housing.

2. Release the hold-down clips and remove the endcover.

3. Remove the air filter element by pulling it out ofthe housing.

4. Clean the housing interior with a damp cloth. Donot blow dirt out with compressed air.

5. Replace the element.

6. Reassemble in the reverse order.

7.8 Separator maintenanceReplace the separator element when indicated by thecontroller or after one (1) year, whichever comes first.

Figure 7-1: Fluid filter assembly

1. Filter head

2. Gasket

3. Element1

1Fluid filter replacement element: P/N: 250025-526Figure 7-2: Air filter assembly

1. Element1

2. Cover

3. Vacuator valve

4. Housing

5. Protection cap1Air filter element replacement P/N: 02250135-155

Page 73: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 7: Maintenance

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 72

The separator element must be replaced. Do not attemptto clean the separator element.

7.8.1 Separator element replacementRefer to Figure 7-3. The separator element must bechanged when indicated by the controller, or once a year,whichever occurs first. Follow the procedure explainedbelow for separator element replacement.

1. Disconnect all piping connected to the sepa-rator cover plate.

2. Loosen and remove the ten (10) hex headcapscrews (¾ in × 3¼ in) and lock washersfrom the cover plate.

• Always discard the lock washers.

3. Pivot the cover plate from the separator/sump tank using ½" jackscrew, then pivot thecover plate to the side.

4. Remove the separator element.

5. Scrape any old gasket material from theunderside of the cover plate and the separa-tor/sump tank flange

• Do not let any scraps fall into the separa-tor/sump tank.

6. Inspect the separator/sump tank for rust, dirt, etc.

7. Insert a new separator element into the sep-arator/sump tank taking care not to dent theelement against the tank opening.

• Do not remove the staples from the sepa-rator element.

• Do not use any type of gasket eliminator.

8. Replace the cover plate, lock washers andcapscrews. Torque to 250 ft·lbs (339 N·m).

• Always use new lock washers.

9. Verify continuity between the separator ele-ment and the separator/sump tank.

10. Reconnect all piping.

11. Clean the return line strainer before restart-ing the compressor.

WARNING

High-pressure hazard.

Relieve all pressure from the separator/sump tank and all compressor lines.

Figure 7-3: Separator element assembly

1. Separator/sump tank

2. Separator element1

3. Cover plate

4. Lock washer

5. Capscrew1Separator element replacement P/N: 02250229-242

Page 74: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

7: Maintenance LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0573 Subject to EAR, ECCN EAR99 and related export control restrictions.

7.9 Oil return / sight glass maintenance

Refer to Figure 7-4. The oil return/sight glass subassem-bly is attached to the side of the separator tank. Oilreturn/sight glass maintenance should be performed on aroutine basis parallel to that of the fluid filter, or as indi-cated in the troubleshooting section of this manual. Themaintenance on an oil return/sight glass is mainly con-cerned with the condition of the filter assembly. Order fil-ter assembly No. 02250117-782, and use the followinginstructions as a guide.

1. Disconnect the tube at bottom of sight glass.

2. Unscrew the sight glass assembly where theelbow fitting joins the strainer/filter.

3. Remove used filter assembly, and replacewith new assembly.

4. Inspect and clean the orifice inside the sightglass blocks. The orifice must be removedwith an allen wrench.

5. Coat/lubricate the O-rings with siliconegrease.

6. Reattach the connectors to the sight glass/orifice blocks.

7.10 Pressure regulator adjustment(for fixed speed non-spiral valve machines only)

Refer to Figure 7-5. Start the compressor and adjust theservice valve to maintain service air pressure approxi-mately at 1 psi over rated pressure. Turn the inlet valveregulator adjusting screw until air just begins to escapefrom the control air orifice, located at the bottom of theregulator. Lock the adjusting screw in place with the lock-nut. The regulator is now properly set.

2

3

4

5

6

1

Figure 7-4: Oil return / sight glass

1. To separator/sump tank

2. Filter assembly1

3. Sight glass / orifice block

4. Brass plug orifice

5. Female tube connector

6. To unit1Oil return filter replacement kit P/N: 02250117-782

12

Figure 7-5: Regulator adjustment

1. Locking nut

2. Adjustment screw

Page 75: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 7: Maintenance

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 74

7.11 Water condensate drain maintenance

It is necessary to periodically clean the strainer. Removethe hex cap from the strainer and remove the strainerscreen. Clean the screen and reinstall. If the screen isdamaged, the strainer assembly must be replaced.

7.12 Control line strainerThe regulator and solenoid valve(s), which control thecompressor, are protected by a strainer. Every 12 monthsit is necessary to clean the strainer. Remove the hex capfrom the strainer and remove the strainer screen. Cleanthe screen and reinstall. If the screen is damaged, thestrainer assembly must be replaced.

7.13 Shaft coupling maintenanceThe compressor unit and motor are rigidly connected viaa mounting adapter housing. This arrangement makescoupling alignment unnecessary. The coupling is a jawtype in shear. If the elastomeric element requiresreplacement due to wear or breakage, perform the fol-lowing steps.

1. Remove the protective grill from the housing.

2. Loosen the retaining screw located on theouter sleeve. Slide the sleeve to one side,exposing the coupling element.

3. Unwrap the coupling element from the cou-pling jaws.

4. Install the new element by wrapping itaround the jaws, engaging the cogs on theelement into the jaws.

5. Reinstall the outer sleeve and the protectivegrill. Secure the outer sleeve by tighteningthe two screws to 45 in·lbs (5 N·m).

7.14 Troubleshooting

7.14.1 Introduction The information contained in the Troubleshooting Guidehas been compiled from field report data and factoryexperience. It contains symptoms and usual causes forthe described problems. However, do not assume thatthese are the only problems that may occur. All availabledata concerning a problem should be systematically ana-lyzed before undertaking any repairs or componentreplacement procedures.

A detailed visual inspection is worth performing foralmost all problems and may avoid unnecessary addi-tional damage to the compressor. Always remember to:

• Check for loose wiring.

• Check for damaged piping.

• Check for parts damaged by heat or an electri-cal short circuit, usually apparent by discolor-ation or a burnt odor.

Should your problem persist after making the recom-mended check, consult your nearest Sullair representa-tive.

Page 76: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

7: Maintenance LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0575 Subject to EAR, ECCN EAR99 and related export control restrictions.

7.14.2 Troubleshooting guide

Symptom Probable cause Remedy

Compressor will not start

Main disconnect switch open Close switch.

Line fuse blown Replace fuse.

Motor starter overload trippedReset. Should trouble persist, check whether motor starter contacts are functioning properly.

Low incoming line voltageCheck voltage. Should voltage check low, con-sult power company.

Compressor shuts down with air demand present

Loss of control voltageCheck power supply for 24V DC output. Replace power supply if necessary.

Low incoming voltage Consult power company.

Excessive operating pressure

Reset. If trouble persists, check that line pres-sure does not exceed maximum operating pres-sure of the compressor (specified on nameplate).

Separator requires mainte-nance indicated by controller

Replace separator.

Machine programmed for wrong pressure setting

Reprogram.

Defective solenoid valveSolenoid valve should cause inlet valve to close when unload pressure is exceeded. Repair if defective.

Defective blowdown valve

Blowdown valve should exhaust separator/sump tank pressure to 25 psig (1.72 bar) when maximum operating pressure is reached. Repair if defective.

Cooling water temperature too high

Reduce water temperature to 85°F (29.4°C) or less. Water-cooled only.

Cooling water flow insufficientCheck water lines and valves (water-cooled only).

Cooler pluggedClean tubes. If plugging persists, install water conditioner (water-cooled only).

Cooling air flow restricted Clean cooler and check for proper ventilation.

Ambient temperature is too high

Provide sufficient ventilation.

Low fluid level Add fluid.

Clogged filter Change the fluid filter element.

Thermal valve not functioning properly

Replace element.

Water flow regulating valve not functioning properly

Change (water-cooled only).

Page 77: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual 7: Maintenance

02250231-030 R05Subject to EAR, ECCN EAR99 and related export control restrictions. 76

Compressor will not build full discharge pressure

Air demand is too great Check service lines for leaks or open valves.

Dirty air filterCheck the filter indicator and inspect and/or change element if required.

Inlet valve bleed orifice plugged

Ensure control line bleed orifice located inside inlet valve is not plugged.

Pressure regulator out of adjustment

Adjust regulator according to control adjust-ment instructions in the Maintenance section.

Defective pressure regulator Replace regulator.

Defective unload solenoid valve

Check that the valve closes when energized. Replace the coil or the complete valve if defec-tive.

Line pressure rises above unload pressure set-point

Leak in control system caus-ing loss of pressure signals

Check for leaks.

Inlet valve stuck openRemove the intake hose and check for inlet valve operation.

Defective unload solenoid valve

Check that the valve is open when de-ener-gized. Replace if necessary.

Plugged control line strainerClean strainer (screen and O-ring replacement kit available).

Defective blowdown valve

Check that separator/sump tank pressure is exhausted to the atmosphere when the sole-noid valve opens. Repair or replace if neces-sary (kit available).

Excessive compres-sor fluid consumption

Clogged return line or orifice

Clean strainer (screen and O-ring replacement kit available).

Clean orifice.

Separator element damaged or not functioning properly

Change separator.

Leak in the lubrication system Check all pipes, connections and components.

Excess fluid foaming Drain and change.

Fluid level too highDrain and change. Check that the compressor temperature has not dropped below 170°F (76.7°C).

Pressure relief valve opens repeatedly

Defective pressure relief valve Replace.

Plugged separator Check separator differential.

Symptom Probable cause Remedy

Page 78: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

7: Maintenance LS90, LS90S, LS90V, LS110, LS110S, LS110V User Manual

02250231-030 R0577 Subject to EAR, ECCN EAR99 and related export control restrictions.

Liquid water in com-pressed air lines

Plugged strainer in moisture drain line

Clean and service strainer located in the line off the bottom of the water separator.

Water vapor condensation from cooling and compression occurs naturally

Remove the water vapor from compressed air prior to distribution through the air system. Check operation of aftercooler and moisture separator. Install a compressed air dryer sized for the flow and dryness level required. (Note: Filters may also be required to remove particu-lates, liquid oil aerosols or for oil vapor removal. Change cartridges as recommended by the fil-ter manufacturer). Check all drain traps rou-tinely to insure their proper operation. Maintain them regularly.

Defective drain valveEnsure valve opens and closes using the test button.

Symptom Probable cause Remedy

Page 79: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Subject to EAR, ECCN EAR99 and related export control restrictions.

Page 80: Industrial Air Compressor LS90, LS90S, LS90V, LS110 ...r05).pdf · Sullair training courses provide hands-on and classroom instruction for the proper operation, maintenance, and servicing

Information and specifications are subject to change without prior notice.Subject to EAR, ECCN EAR99 and related export control restrictions.

Sullair, LLC1 Sullair Way

Michigan City, IN 46360 USAwww.sullair.com

1-800-SULLAIR (USA only)1-219-879-5451 (non-USA)