2

HS-100SF Series V ibr ation Sensor · TS140 Iss01 Please contact our Sales Office for information on sensor accessories (mounting studs, etc) and multichannel switch boxes. We reserve

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • Tel: +44(0) 845 680 1957Fax: +44(0) 845 680 1958Email: [email protected]: www.hansfordsensors.com

    Operating Temperature RangeSealingMaximum ShockEmissionsImmunity

    -40 to 100 ºCIP655000 gEN61000-6-4:2007EN61000-6-2:2005

    Case MaterialSensing Element/ConstructionMounting TorqueMounting Bolt provided

    WeightMaximum Cable lengthStandard Cable LengthMounting ThreadsOptions

    Stainless SteelPZT/Compression8 NmM6 x 33 mm long, ¼- 28 UNF x 33 mm longor M8 x 33 mm long170 gms (nom)1000 metres5 metresSee 'How to order' table Connector, cable length, various mounts,other sensitivities

    Mounted Base ResonanceSensitivityFrequency Response

    IsolationMeasurement RangeTransverse SensitivityElectrical

    22 kHz (nominal)See table1.5 Hz to 10 kHz ±5 %0.2 Hz to 15 kHz ±3 dBBase isolatedSee tableLess than 5%

    Typical Applications

    Proven use in vibration monitoringfor offline applications using commerciallyavailable data collectors and onlinemonitoring systems in the fields ofConstruction Engineering, Paper and Pulp,Metals Manufacture, Wind Farms andnumerous other applications where lowspeed vibration monitoring is required.

    Protecting...Gearboxes, Rolls, Wind Turbines,Rotors and other low speed machinery.

    HS-100SF Series Vibration SensorFire Retardant Cable, Low Profile, Low Speed Accelerometer

    Technical Performance

    Environmental

    Mechanical

    Electrical NoiseCurrent RangeBias VoltageSettling TimeOutput ImpedanceCase Isolation

    0.1 mg max0.5 mA to 8 mA10 - 12 Volts DC2 seconds200 Ohms max.>10 Ohms at 500 Volts8

  • HS-100SF Series Vibration Sensor

    Dimensions

    Frequency Response

    Tel: +44(0) 845 680 1957Fax: +44(0) 845 680 1958Email: [email protected]: www.hansfordsensors.com

    Ref: HS100SF-FR-0111

    Mounting of sensor to achieve good repeatable readings.Vibration sensor should be firmly fixed to a flat surface (spotface surface may be needed to be produced and cable anchoredto sensor body.)

    TS140 Iss01

    Please contact our Sales Office for information on sensor accessories (mounting studs, etc) and multichannel switch boxes.

    We reserve the right to alter the specification of this product without prior notice.

    2

    4

    How to order

    White

    Black