    Getting Help

    FASTFIND LINKS

    Hitachi Virtual Storage Platform Hitachi Universal Replicator for Mainframe User Guide

    MK-90RD7031-14

  • Hitachi Virtual Storage Platform Hitachi Universal Replicator for Mainframe User Guide

    ii

    2010 - 2014 Hitachi, Ltd. All rights reserved.

    No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd. (hereinafter referred to as "Hitachi") and Hitachi Data Systems Corporation (hereinafter referred to as "Hitachi Data Systems").

    Hitachi and Hitachi Data Systems reserve the right to make changes to this document at any time without notice and assume no responsibility for its use. This document contains the most current information available at the time of publication. When new and/or revised information becomes available, this entire document will be updated and distributed to all registered users.

    Some of the features described in this document may not be currently available. Refer to the most recent product announcement or contact your local Hitachi Data Systems sales office for information about feature and product availability.

    Notice: Hitachi Data Systems products and services can be ordered only under the terms and conditions of the applicable Hitachi Data Systems agreements. The use of Hitachi Data Systems products is governed by the terms of your agreements with Hitachi Data Systems.

    Hitachi is a registered trademark of Hitachi, Ltd. in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd. in the United States and other countries.

    ShadowImage and TrueCopy are registered trademarks of Hitachi Data Systems.

    AIX, ESCON, FICON, FlashCopy, Hyperswap, IBM, MVS/ESA, MVS/XA, OS/390, S/390, VM/ESA, z/OS, zSeries, z/VM, and z/VSE are registered trademarks or trademarks of International Business Machines Corporation.

    All other trademarks, service marks, and company names are properties of their respective owners.

    Microsoft product screen shots reprinted with permission from Microsoft Corporation.

  • iiiHitachi Virtual Storage Platform Hitachi Universal Replicator for Mainframe User Guide

    Contents

    Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiIntended audience. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiiProduct version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiiDocument revision level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiiChanges in this revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiiReferenced documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiiiDocument organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiiiDocument conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xivConvention for storage capacity values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvAccessing product documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvGetting help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvComments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvi

    1 Universal Replicator for Mainframe overview . . . . . . . . . . . . . . . . 1-1Universal Replicator for Mainframe software . . . . . . . . . . . . . . . . . . . . . . . . . 1-2How Universal Replicator for Mainframe works . . . . . . . . . . . . . . . . . . . . . . . . 1-2Hardware and software components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

    VSP storage systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Main and remote control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

    Pair volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6Journal volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6Journals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6Data path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7Extended consistency groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8Storage Navigator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8Business Continuity Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

    Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8Overview of copy operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

    Initial copy operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8Update copy operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

    Read and write I/O during remote copy . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9Differential data management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10

  • Hitachi Virtual Storage Platform Hitachi Universal Replicator for Mainframe User Guide

    iv

    S-VOL write option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10S-VOL read option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10Pair status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10

    2 Requirements and specifications . . . . . . . . . . . . . . . . . . . . . . . . . 2-1System requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2Business Continuity Manager specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5Command device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

    3 Planning volumes, VSP systems . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1Plan and design workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2Assessing business requirements for data recovery . . . . . . . . . . . . . . . . . . . . 3-3

    Determining your RPO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3Write-workload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

    Measuring write-workload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4Sizing journal volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4Planning journals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5Data transfer speed considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6

    RAID group configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6Fibre-channel port configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7

    Planning journal volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7Host I/O time stamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8

    Planning pair volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8Data and journal volume specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9Duplicating VOLSERs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9Maximum number of pairs allowed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10

    Calculating maximum number of pairs . . . . . . . . . . . . . . . . . . . . . . . . 3-10Maximum initial copy operations and priorities . . . . . . . . . . . . . . . . . . . . 3-12

    Disaster recovery considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13Error reporting communications (ERC) . . . . . . . . . . . . . . . . . . . . . . . . . 3-14

    Sharing volumes with other VSP software volumes . . . . . . . . . . . . . . . . . . . . 3-14Planning URz in multiple VSPs using a consistency group . . . . . . . . . . . . . . . 3-14

    Multiple journals per CCI consistency group . . . . . . . . . . . . . . . . . . . . . 3-17Establishing connections between multiple secondary systems . . . . . . . . 3-19Planning extended consistency groups (EXCTG) . . . . . . . . . . . . . . . . . . 3-20

    Planning for previous models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20Guidelines for preparing systems for URz . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21

    System option modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22

    4 Planning the data path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1Data path design workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2Sizing bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    Five sizing strategies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2Calculating bandwidth . . . . . . . . . . . . . . . . .

Recommended

View more >