HEPA FILTERED PATIENT ISOLATION ROOMS • Neutropenic Patient Isolation Room • Infectious Patient Isolation Room www.filtrex.co.uk Unit 17, Burnt Mill Industrial Estate, Elizabeth Way, Harlow, Essex, CM20 2HS Telephone: 01279 457590 | Fax: 01279 457591 | Email: sales@filtrex.co.uk High level protection against airborne infections Zero leakage HEPA filter system Negative plenum UV inactivation Comfort living area Low noise level Optimized heating / cooling Comfort temperature distribution Maximum savings Fast and easy modular installation Low energy consumption Validation guarantee Easy Use and Maintenance Isolated air ventilation system Advanced microprocessor control

HEPA FILTERED PATIENT ISOLATION ROOMS...FILTREX SYSTEM 345 m³/h 58 kWh/day 64,8 kWh/day 3670,8 kW/day 6522,8 kW/day *Comparison of HEPA filtration energy consumption between conventional

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HEPA FILTERED PATIENT ISOLATION ROOMS...FILTREX SYSTEM 345 m³/h 58 kWh/day 64,8 kWh/day 3670,8 kW/day 6522,8 kW/day *Comparison of HEPA filtration energy consumption between conventional

HEPA FILTEREDPATIENT ISOLATION ROOMS

• Neutropenic Patient Isolation Room

• Infectious Patient Isolation Room

www.filtrex.co.ukUnit 17, Burnt Mill Industrial Estate, Elizabeth Way, Harlow, Essex, CM20 2HSTelephone: 01279 457590 | Fax: 01279 457591 | Email: [email protected]

High level protection againstairborne infections

Zero leakage HEPA filter system

Negative plenum

UV inactivation

Comfort living areaLow noise level

Optimized heating / cooling

Comfort temperature distribution

Maximum savingsFast and easy modular installation

Low energy consumption

Validation guarantee

Easy Use and MaintenanceIsolated air ventilation system

Advanced microprocessor control

Page 2: HEPA FILTERED PATIENT ISOLATION ROOMS...FILTREX SYSTEM 345 m³/h 58 kWh/day 64,8 kWh/day 3670,8 kW/day 6522,8 kW/day *Comparison of HEPA filtration energy consumption between conventional

Fresh air and pre-�ltration

HEPA �ltration (0.3μm, %99,97)

Recirculation air

Air conditioning and treatment

Negative plenum technology

Zero leakage from ducts and ceiling

SPECIFICATIONS

PATIENT ISOLATION ROOMS

ADVANCED SPECIFICATIONS

PATIENT ISOLATION ROOM

Stand alone air ventilation & treatment: Decreased loss and problems compared to central HVAC integrated systems

Excellent Particle Removal Capacity through the discharge of the air velocity from the ceiling top and air intake from the �oor base.

Prevention of contaminated air leakage from ceiling or surrounding

Continous UV inactivation of heating/cooling units coil surfaces

Minimum dead zones: Unique air�ow & air diffuser designs

Eco mode work: Saves energy, keeps room cleanliness class

High performance HEPA-Fan-Filter Unit Air Filtration

Independent adjustment of ACH

Real time monitorized Positive air pressure

Page 3: HEPA FILTERED PATIENT ISOLATION ROOMS...FILTREX SYSTEM 345 m³/h 58 kWh/day 64,8 kWh/day 3670,8 kW/day 6522,8 kW/day *Comparison of HEPA filtration energy consumption between conventional

TECHNOLOGIES

Hybrid airflow by unique HEPA Fan Filter units and sophisticated

CFD modelling

• Laminar air�ow over operation bed

• Turbulent air�ow at rest of the room

Non-disturbing airflow rate for patient

Owerflow air sweeping technic to surrounding rooms

PID controlled precise temperature adjustment

Very low noise level by active noise control system (optional)

Fast and safe decontamination-room recovery (optional)

Excellent air and temperature distribution by CFD modelling

Early amortization by Filtrex energy saving designs • Decreased pressure loss by unique HEPA Fan Filter Unit • Increased HEPA life through perfect pre-�ltration • Ef�cent Centrifuge Fan with back inclined vane structure • Only needed fresh air usage • Automaticc �lter compensation system • Decreased air transport volume

ROOM HEPA FILTERED AIR DISTRIBUTION

NEGATIVE PRESSURE PATIENT ROOMPOSITIVE PRESSURE PATIENT ROOM

MIN. TEMPERATURE: 17.0°CMAX. TEMPERATURE: 36.7°CAVG. TEMPERATURE: 18.8°C

ROOM TEMPERATURE DISTRIBUTION

AIR LEAKAGERATE

HEATING LOSSENERGY AMOUNT

COOLING LOSSENERGY AMOUNT

HEATING

COOLING

1449 m³/h

301 kWh/day

268,6 kWh/day

5980 kW/day

9080,4 kW/day

CLASSICCALSYSTEM

FILTREXSYSTEM

345 m³/h

58 kWh/day

64,8 kWh/day

3670,8 kW/day

6522,8 kW/day

*Comparison of HEPA filtration energy consumption between conventional and Filtrex system

(Calculations based on 40 patient isolation room)

Page 4: HEPA FILTERED PATIENT ISOLATION ROOMS...FILTREX SYSTEM 345 m³/h 58 kWh/day 64,8 kWh/day 3670,8 kW/day 6522,8 kW/day *Comparison of HEPA filtration energy consumption between conventional

m3/h

ACH (1/h)

m3/h

ACH (1/h)

m3/h

m3/h 200-400

200-500

≥ ACH 3

800-1400

≥ ACH 10

600-1000

Nominal rate is 400 m3/h. Adjustable.

Air change per hour (ACH) is kept at minimum 3.

Nominal rate is 2400 m3/h. Adjustable.

Nominal rate of ACH =12

SPECIFICATION UNIT RATE DESCRIPTION

VENTILATION

FILTRATION

Laminer air �ow over patient bed, turbulent air �ow type at rest of the room, hybrid air �ow type is applied. Filtered air directs from the ceiling and sucked through by 2 different positioned culvers at the bottom.

Ower�ow air are swept to ante room through culverts at the door top of Neutropenic patient room. (Min. 2m/s) Sweeping of ower�ow air at Infectious Patient room is not being applied.

m3/h 100-150Air exhausted through air ducts to the athmosphere. WC area iskept at min 15 Pa negative pressure.

m3/h 1500-2500Air exhausted through air ducts to the athmosphere. Exhaust airducts are kept at min 8 Pa negative pressure.

Air flow type and direction

Fresh air flow rate

Ach

Toplam hava debisi

Total air change per hour

Recirculation air flow rate

RS 485 connected hygenic wall type temperature and humidty sensor

Micro type pressure key performs between 7-25 Pa measurement.

Average air �ow rate measurement by rotor type air �ow velocity sensor.

Temperature Sensor

Pressure Sensor

Air Flow Measurement

G4 panel type pre-�lter, F7 V-type pre-�lter, H12 class HEPA �lter

F7 casette type pre-�lter, H13 HEPA �lter

Fresh air

Patient room

ALARMS

Activated at room pressure under 8 Pa

Alarm activation at ACH ≤ 5

Pressure

Air Flow Rate

HEATING-COOLING

Owerflof air flow rate

Exhaust air duct air flow rate

Wc exhaust air flow rate

Cold/Warm water, electrical heater, UV inactivation system, air-mix compartment, condensation prevented unpassaged heating featured �at isolation panel, easy cleaning surfaced heating/cooling units. Heating/Cooling power min. 5000 Watt.

Patient room

QUALITY AND CERTIFICATES

CE, ISO9001-2008, ISO 14644 Clean Room class compatibility, Electrical and Electronic safety compatibility of EN61010, Accredited test company Validation guarantee (When installation made by Metis or by its certi�ed technical service personnel)

Certificates

AUTOMATION SYSTEM/SERNSORS

5,7 Inch touch sensitive screen PLC control panel: Continuous measurement of temperature, pressure, air �ow rate controlled by sensors. Energy saving through Day and Night (Eco) mode run.Control Parameters

Telephone: 01279 457590 | Fax: 01279 457591 | Email: [email protected] | www.filtrex.co.ukUnit 17, Burnt Mill Industrial Estate, Elizabeth Way, Harlow, Essex, CM20 2HS

PATIENT ISOLATION CEILING TYPE HEPA FILTRATION SYSTEM TECHNICAL SPECIFICATIONS