21
Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Embed Size (px)

Citation preview

Page 1: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Harnessing the Heat:from reservoir to the wellhead

Steam from Wairakei borefield, N.Z. in 1970s

Page 2: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Stylized cross-section of “typical” high-temperature geothermal system (Henley and Ellis, 1983)

• upflowing plume of hot water at 250º – 350ºC from 3 – 5 km depth; deep heat source usually cooling intrusion

• isotopes of water show upper plume is predominantly meteoric water• more extensive “outflow” zone in upper 1 – 2 km of plume where there is mixing with surrounding cooler waters, boiling in the hotter parts of the plume, and merging with the surface ground water as springs and underflow • for system beneath a volcano, steam outflow (fumaroles, maybe be closer to deep upflow zone than the hot springs, which may be down-slope

Heat output ~ 100 MWth

Geothermal “reservoir”

(1 – 3 km depth)

Page 3: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

• If the geothermal fluid stays liquid, then the reservoir heat extraction is relatively simple

• cooling of production water yields the heat (mass flow * specific heat* temperature drop) (specific heat water = 4 kJ/kg/ºC)

• issues are efficiency of heat exchanger, and possible scaling potential of the cooled water, and size of the hot reservoir (subjects of later lectures)

The simplest form of harnessing the heat

Page 4: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

A good water well (artesian) can have water flowing at ? 1 m/s at the wellhead (2 mph)

A good geothermal well flows at??

343 m/s or 768 mph

This is the speed of sound in air

Page 5: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Video clip of opening a geothermal well with vertical discharge; watch for:

1. Initial high frequency noise (first few seconds) is from bleed line to prevent too much well-head pressure while closed

2. The first few turns of the master valve take two guys because of that pressure; these valves are usually opened as quickly as possible to avoid damage from something coming up the wellbore (e.g. rock fragments)

3. There is a change from high frequency noise in discharge to lower frequency when discharge changes from dry steam, to steam and water (2-phase). Can also then see wet condensate drifting from plume

4. Surging discharge from the well as it unloads the initial static column of liquid; this process can take 15 – 30 minutes; (this video clip is edited – its about a minute long)

5. This is a 100 MWth well = ~ 10 MWe (this well has a feedzone at about 250ºC; TH2 in Tauhara field, N.Z. Video courtesy of Contact Energy Ltd.)

Page 6: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s
Page 7: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Modern wellhead in N.Z.

Page 8: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Geothermal vs. oil, gas, water wells

Energy Source "Good" Well Flow Rate Energy Flow Rate Value ($/day per well)

Geothermal 100 kg/s 100 MWth, 10 MWe $24k @ 10c/kWh

Ground Water 2000 gpm (130 kg/s) pump needed $3k @ $1/1000 gal

Oil 10,000 bbl/d (16 kg/s) 640 MWth $80k @ $80/bbl

Natural Gas 10,000 mcf/d 125 MWth $40k @ $4/mcf

Page 9: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Water: liquid/vapor relationships

Elevation Atmospheric Pressure (abs.) Saturation Temperaturem asl ft asl bar kPa psi ºC ºF

0 0 1 100 14.5 100 2121 3300 0.9 90 13.1 97 2072 6600 0.8 80 11.6 95 2033 9800 0.7 70 10.2 92 198

• We all know as atmospheric pressure decreases with elevation the boiling point of water also decreases….

• what is the boiling point in Salt Lake City (elevation ~ 4500 ft asl)?

Note: 1 bar absolute = 0 bar gauge pressure

Page 10: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Ascending water at 250 ºC

Pressure (depth) of first boiling

Liquid and steam

• previous slide looked at curve for < 100 ºC

• coexisting water and steam lie on the saturation (boiling point) curve

• Boiling process shown here as pressure drops with ascending water (could be hot water rising up a well, or in a fracture zone)

• Reverse process would be condensation (starting with vapor and increasing pressure or decreasing temperature)

Critical point

Page 11: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Steam and water have very different properties!

Steam tables are very useful for quick calculations of steam-water properties

Enthalpy is “usable heat” (spec. heat * temp.); density = 1/specific volume

Note at 200 ºC (~15 bar), water has 30% the heat content, but 100 times the density of steam

Page 12: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Pressure-depth relationships(let’s convert pressure axis to depth axis)

• Pressure = density * grav. accel.* thickness

In metric units, pressure is in Pa, but its very small!

In cold water,

1 bar (100 kPa) = 1000 kg/m3 * 10 m/s2 * 10 m

In rock with density of 2500 kg/m3

100 bar = 2500 kg/m3 * 10 m/s2 * 400 m (= 10MPa)

Q1: what would be the pressure of cold water at 400 m depth?Q2: what would be the pressure of hot water (800 kg/m3) at 400 m depth?

Page 13: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

• In geothermal systems we are interested in the density of the continuous pore fluid phase

• Usually this is hot hydrostatic, but steam zones may be important (analogous to vadose zones in ground water systems)

Page 14: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Boiling Point for Depth Relationship (BPD)

(In fluids, total vapor pressure is the sum of the partial pressures of each vapor component; e.g. Ptot = PCO2 + PH2O)

Page 15: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

What happens when we draw down a cold water well?

Draw down = 5 bar (50 m)

What about a geothermal well?

Page 16: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

What would the discharging profile look like for a geothermal well?

Page 17: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Example of a discharging geothermal well

Page 18: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

The temperature profile confirms the depth of initial boiling

Page 19: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Calculating steam/water mixtures

Initial water

Ti, Pi, Hli

pressure drop (and temperature drop)

Steam with enthalpy Hse

Liquid with enthalpy Hli

end state: Te, Pe

We do simple conservation of heat calculation (initial vs. end):

• heat = enthalpy (kJ/kg) * mass flow (kg/s) = kJ/s = kW

• assume initial mass flow = 1; end steam fraction = m

• Hli * 1 = m * Hse + (1-m) * Hle

• m = (Hli – Hle) / (Hse – Hle) note: (Hse – Hle) = latent heat of steam (end)

• and 1-m (water fraction) = (Hse – Hli) / (Hse – Hle)

Page 20: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

Example of calculating steam fraction:assume upflowing water at 240 ºC; end is atmosphere @100 ºC

• Enthalpy initial water = 1038 kJ/kg (from steam tables)• Enthalpy of end water = 419 kJ/kg ( “ )• Difference = 619 kJ/kg

• Latent heat steam at end = 2257 kJ/kg

• Steam fraction = 619/2257 = 27%• Water fraction = 73%

• Steam fraction would be smaller if end state is the separator pressure set for inlet of turbine

• At 100 ºC, specific volume of steam is over 1000 times that of 240 C water. Volume flux up wellbore amount to about 300 times increase!

Page 21: Harnessing the Heat: from reservoir to the wellhead Steam from Wairakei borefield, N.Z. in 1970s

We now understand how steam and water get to the wellhead – let’s generate electricity!