24
Technique Follows Technology Genuine In-Ovation ® R

Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Technique Follows Technology

Genuine

In-Ovation®R

Page 2: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Over One Million Patients Treated… And Counting

32,772,652…Enough brackets:• To go from your practice to outer space.

• To go up the Empire State building...438 times.

• To go up the Eiffel Tower...600 times.

Part Art. Part Science. All Orthodontics.™

In-Ovation R has been recognized as an industry leader for over a decade. Thousands of clinicians worldwide have trusted In-Ovation to treat their patients. The precision and quality built into these brackets offers repeatable success, practice efficiencies and beautiful results every time. See how far In-Ovation R can take you, your patients and your practice.

Success Bound

Genuine

In-Ovation® R

Page 3: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

$350 average hourly profit

3 hours per case

+

=

$1,050 extra profit!

180 minutes

saved per case

150 patients

+

=225 hours of chair

time each year!

Finding the Extra 225 Hours Hidden In Your Schedule*

In-Ovation R self-ligating brackets offer you the luxury of faster, more infrequent visits from your patients. Whether you use this benefit to streamline your schedule for a less hectic day, bump up the bottom line by treating additional patients or even reassessing how you practice to enjoy more free time to pursue your passions, it’s nice to be able to choose. Because once you start realizing all the time-saving benefits of the In-Ovation R brackets, you can really begin to manage your practice… and not the other way around.

Improve Your Bottom Line

In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more hours in your day, the benefits can really start to add up.

With an average savings of three hours chair time per case, In-Ovation R braces can add $950 – $1050 profit, per patient, to your bottom line.

*Based on an average case load of 150 patients and an average 2 year treatment time.

Clinical Benefits

Improved patient satisfaction

Direct patient referrals

Additional GP referrals

Extra billable hours

Decrease number of total

appointments per case

Increase time between

appointments

Reduction in-office stress

Better time management

More face time with your patient

Benefits Beyond Clinical

Spend more time with your family

Play more golf

Pursue your passions

One extra day off a week

Travel

Go sailing

Volunteer

Go fishing

Just relax and do nothing

Page 4: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

ControlInteractive spring clip for control throughout treatment

Practice Advantages Not all self-ligating brackets are created equal. In-Ovation R brackets were created to optimize the treatment process with precision engineering and true straight wire design.

The In-Ovation orthodontic systems are the result of a keen understanding of human physiology and orthodontic engineering. The compound contoured base of the In-Ovation R bracket is designed to provide a precise anatomical fit across the enamel surface of the tooth. The smooth swept tie-wings are engineered to minimize occlusal interference in order to increase patient comfort. In addition, the chamfered archwire slot is designed to reduce chair time by facilitating wire engagement and reducing the chance of archwire binding or crimping. This dedication to quality and attention to detail is infused into every product that carries the In-Ovation name.

PrecisionTrue straight wire design for optimal, precise treatment options

QualityHighly advanced manufacturing processes with over a decade of real-world repeatable success

*With In-Ovation, doctors realize an approximate chairside time-savings of 3 hours per patient.

Chair Time* In MinutesAges 18-59

500

400

300

200

100

Traditional Bracket

476.76

302.55

In-Ovation**

**Jerry R. Clark, DDS, MS, Jack Gebbie, BS, Datatex Market Research Report Summary: Increasing Practice Efficiency and Profitability Using In-Ovation Self-Ligating Brackets, March, 2007. Datatex is a member of CASRO® - Council of

American Survey Research Organizations

Part Art. Part Science. All Orthodontics.™

Page 5: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Patient AdvantagesToday more than ever, patients are doing their part to better understand the options available to them. Savvy practices have come to recognize this as an opportunity, enabling you to offer the benefits of self-ligation as an adjunct to your talent, technique and reputation.

In providing a self-ligating option, you’ll be able to offer your patients less chair time, fewer appointments and a cleaner, more esthetic appearance. In doing so, you’ll be able to create a perceived (and potentially significant) point of differentiation between your practice and the other competing practices in the area.

FreedomElastomeric free treatment for longer appointment intervals and enhanced hygiene

ComfortLow-profile and smooth surfaces offer enhanced patient comfort

ConvenienceFewer and shorter appointments mean better control over your daily schedule

Number of Appointments*Ages 18-59

*In-Ovation averages 40% fewer appointments than traditional brackets with ties.

2

4

6

8

10

12

14

16

18

Traditional Bracket

16.26

9.60

In-Ovation**

*In-Ovation finishes equivalent cases approximately 4 months sooner than traditional brackets with ties.

Months in Treatment*Ages 18-59

5

10

15

20

25

Traditional Bracket

23.97

19.83

In-Ovation**

Page 6: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Easy Open Clip

In-Ovation R Dedication to DetailTrue Twin Design – Occlusal and gingival twin tie-wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increase your inter-bracket distance.

Spring Clip – The self-ligating clip extends fully through the vertical channel in the bracket body, enhancing the structural integrity of the clip.

Full Slot Slip Coverage – The In-Ovation R clip provides full coverage across the entire slot for superior rotational control. This allows the clip to interact with the wire both on the mesial and distal, as needed, without the need for auxiliaries.

Triple Chamfered Slot Walls

Spring Clip

Slot Blocker

Full Slot Slip Coverage

Easy Open Clip – The clip opens easily when pressure is applied occlusally to the v-notched clip at the gingival side of the bracket, using the engage

R or similar instrument. The clip can be closed with an instrument or simple finger pressure on the incisal curve.

Slot Blocker – A patented slot blocker prevents the archwire from escaping from the slot and sliding up into the clip engagement channel.

Triple Chamfered Slot Walls – Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping.

True Twin

Part Art. Part Science. All Orthodontics.™

Page 7: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Straight Wire Technology – A true straight wire appliance is one in which all the brackets have been designed to guide the teeth into their ideal position with a preformed wire. In-Ovation R is a true straight wire appliance that features a compound contour base, torque in the base, programmed in/out control and level slot alignment.

Disto-Gingival Dimple – A color code on the disto-gingival tie-wing provides immediate identification of the tooth for which the bracket was designed.

Smooth Swept Tie-Wings

Straight Wire Technology

Base Design

Disto-Gingival Dimple

Vertical Scribe Line

Vertical Scribe Line – A scribe line on the bracket face aids positioning by providing a convenient reference for orienting the center line of the bracket with the facial axis of the clinical crown (FACC).

Smooth Swept Tie-Wings – Smooth, swept tie-wings help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.

Base Design – An 80 gauge single mesh, compound contoured base provides a precise anatomical fit. The Standard Palmer Notation laser etched into the mesh facilitates bracket management with a ready reference of the quadrant, tooth and prescription.

Page 8: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Passive Phase – Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment.

Expressive Phase – Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed.

Active Phase – Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque.

In-Ovation Means Interactive In-Ovation R provides you with the ability to start and effectively finish your treatment with one, simple system. Using the technique of your choice, In-Ovation R enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation R’s unique Interactive technology means you can choose the degree of engagement between the bracket and wire. It can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing.

Passive Expressive Active

Interactive Control

Part Art. Part Science. All Orthodontics.™

Page 9: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Active

FullControl

ModerateControl

Expressive™Passive

LowForce

Control Across the Spectrum Different shapes and sizes interact with the clip in unique ways. Whether sliding freely, sitting in, or extending beyond the slot, In-Ovation’s interaction with archwires offer control in all phases.

Archwire Sizes .018" Slot

Passive .014" .014"/.016" .016" .018"/.020"

Expressive™ .016" x .016" .018" x .018" .018" x .018" .020" x .020" .022" x .018"

Active .016" x .022" .018" x .025" .017" x .025" .019" x .025" .018" x .025" .021" x .028"

.022" Slot

Interactivity Guide

Page 10: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

True Straight Wire Design for Truly Predictable Outcomes In-Ovation is a completely adjusted true straight wire appliance system that positions teeth at all four dimensions: in/out, angulations, torque, and overcorrection. With this completely adjusted four dimensional appliance system you will need no offset bends in the archwires to obtain an optimal finish in most cases (if the brackets are optimally positioned on teeth).

In order to be considered a completely four dimensional appliance, the bracket must contain: • Compound contour base • Torque in base • Proper in/out and anti-rotation • Level slot alignment at the conclusion of appliance therapy

If any of these features is missing from a bracket design, even a case with perfect placement can be compromised.

Compound Contour Base The design of the appliances base must mirror the mesio-distal and occluso or inciso gingival curvature of the crown of each tooth type. The base curvature must be the same or slightly more curved than the tooth surface so that the bracket stem and slot are precisely positioned. This allows the appliance to properly transmit the programmed activation.

Torque In The Base A fundamental necessity for a programmed appliance is torque in the base, but this must be accompanied by the correct base contouring or it will not work properly. This allows the slot point, the base point (middle of the base) and the reference point on the tooth to be on the same plane, a necessity for proper tooth positioning and level slot alignment.

CompoundContour

NoContour

BentSlot

Non-Adjusted Completely Adjusted

Part Art. Part Science. All Orthodontics.™

Page 11: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Programmed In/OutAs a result of the proper thickness relative to the adjacent brackets, in and out (first order) bends are virtually eliminated with proper bracket placement.

Level Slot AlignmentWhen all the teeth reach their programmed positions, all four dimensions are correct, allowing alignment, leveling, and parallelism of all the slots on all the brackets around the arch.

notstraight wire

straight wire

Non-Adjusted Partially Adjusted Completely Adjusted

Page 12: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Andrews® Plane is a registered trademark of Lawrence F. Andrews, 2001.

A Proper Finish Begins With a Proper Start Perhaps the single-most-important phase of orthodontic treatment is proper bracket placement. Taking time to achieve proper placement at the outset can help mitigate—or even eliminate—final archwire bends and correction. What’s more, the importance of bracket placement is further emphasized given the popularity of pre-programmed brackets and true straight wire appliances. Not only will correct placement help cases to progress more-predictably, but it will also ensure treatment concludes on schedule.

Although intuitively simple, many orthodontic professionals underestimate the inherent challenges in bracketing procedures. In many ways, this is understandable. For one, there’s very little published materials made specifically to teach ideal bracketing techniques. In fact much of the difficulty in bracket placement can be exacerbated by the lack of a single, cohesive school of thought. Many individuals have been exposed to numerous techniques over the course of their career. An effort to achieve the benefits of all, may unfortunately lead to a scenario where the clinician winds up inadvertently negating the inherent benefits of a particular technique.

Facial Axis Point (FA point) – The point on the facial axis that separates the gingival half of the clinical crown from the occlusal half.

Facial Axis of the Clinical Crown (FACC) – The most prominent portion of the central lobe on each crown’s facial surface. For molars, the buccal groove that separates the two facial cusps.

Andrews® Plane – The surface or plane on which the mid-transverse plane of every crown in an arch will fall when the teeth are optimally positioned. This plane virtually connects the appliance through the FA point.

Optimal Bracket Position

FAAC FA Point

Andrews® Plane

FACCFA Point

Part Art. Part Science. All Orthodontics.™

Page 13: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Special thanks to Dr. Antonino Secchi for his assistance in creating these images.

Upper Arch FA Point & FACC

Upper Arch Brackets On Andrews® Plane Line

Bracket Placement

Lower Arch FA Point & FACC

Lower Arch Brackets On Andrews® Plane Line

Page 14: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Brackets and tubes placed in the ideal position along the references previously shown. The yellow line represents the Andrews® Plane, virtually connecting the appliance through the FA point.

Intraoral photo showing a case with the final wire just before the appliance is removed. The combination of a well designed appliance and proper bracket placement allows for ideal finishing with the appliance still in place!

Intraoral photo showing the final result right after the appliance is removed.

Full Arch Representation

The FA point and FACC for each maxillary and mandibular tooth in an ideal alignment are shown.

Part Art. Part Science. All Orthodontics.™

Page 15: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

EUROMaxillary .018 .022Tooth T A Of Right Left Right Left

U1 17 4 0 189-111-80 189-211-80 189-112-80 189-212-80

U2 10 8 0 189-121-80 189-221-80 189-122-80 189-222-80

U3 -7 8 0 189-131-80 189-231-80 189-132-80 189-232-80

U3/hook -7 8 0 189-131-81 189-231-81 189-132-81 189-232-81

U4 -7 0 0 189-541-80 189-541-80 189-542-80 189-542-80

U4/hook -7 0 0 189-141-81 189-241-81 189-142-81 189-242-81

U5 -7 0 0 189-551-80 189-551-80 189-552-80 189-552-80

U5/hook -7 0 0 189-151-81 189-251-81 189-152-81 189-252-81

MandibularTooth

L1, L2 -6 0 0 189-611-80 189-611-80 189-612-80 189-612-80

L3 -6 3 0 189-331-80 189-431-80 189-332-80 189-432-80

L3/hook -6 3 0 189-331-81 189-431-81 189-332-81 189-432-81

L4 -12 2 0 189-341-80 189-441-80 189-342-80 189-442-80

L4/hook -12 2 0 189-341-81 189-441-81 189-342-81 189-442-81

L5 -17 2 0 189-351-80 189-451-80 189-352-80 189-452-80

L5/hook -17 2 0 189-351-81 189-451-81 189-352-81 189-452-81

RONCONEMaxillary .018 .022Tooth T A Of Right Left Right Left

U1 18 5 0 189-111-60 189-211-60 189-112-60 189-212-60

U2 10 8 0 189-121-60 189-221-60 189-122-60 189-222-60

U2/hook 10 8 0 189-121-61 189-221-61 189-122-61 189-222-61

U3 0 8 2m 189-131-60 189-231-60 189-132-60 189-232-60

U3/hook 0 8 2m 189-131-61 189-231-61 189-132-61 189-232-61

U4, U5 -10 4 2d 189-141-60 189-241-60 189-142-60 189-242-60

U4, U5/hook -10 4 2d 189-141-61 189-241-61 189-142-61 189-242-61

MandibularTooth

L1, L2 1 0 0 189-611-60 189-611-60 189-612-60 189-612-60

L3 -3 7 2m 189-331-60 189-431-60 189-332-60 189-432-60

L3/hook -3 7 2m 189-331-61 189-431-61 189-332-61 189-432-61

L4, L5 -7 1 2d 189-341-60 189-441-60 189-342-60 189-442-60

L4, L5/hook -7 1 2d 189-341-61 189-441-61 189-342-61 189-442-61

ANDREWSMaxillary .018 .022Tooth T A Of Right Left Right Left

U1 7 5 0 189-111-02 189-211-02 189-112-02 189-212-02

U2 3 9 0 189-121-02 189-221-02 189-122-02 189-222-02

U3/hook -7 11 0 189-131-12 189-231-12 189-132-12 189-232-12

U4, U5 -7 0 0 189-541-02 189-541-02 189-542-02 189-542-02

MandibularTooth

L1, L2 -1 0 0 189-611-02 189-611-02 189-612-02 189-612-02

L1, L2/opt. -6 2 0 189-311-22 189-411-22 189-312-22 189-412-22

L3/hook -11 5 0 189-331-12 189-431-12 189-332-12 189-432-12

L4 -17 0 0 189-641-02 189-641-02 189-642-02 189-642-02

L5 -22 0 0 189-651-02 189-651-02 189-652-02 189-652-02

Comprehensive Prescription GuideROTH*

Maxillary .018 .022Tooth T A Of Right Left Right Left

U1 12 5 0 189-111-00 189-211-00 189-112-00 189-212-00

U2 8 9 0 189-121-00 189-221-00 189-122-00 189-222-00

U2/hook 8 9 0 189-121-10 189-221-10 189-122-10 189-222-10

U3 -2 13 4m 189-131-00 189-231-00 189-132-00 189-232-00

U3/hook -2 13 4m 189-131-10 189-231-10 189-132-10 189-232-10

U3/surgical Rx -2 10 4m 189-131-06 189-231-06 189-132-06 189-232-06

U3/hook surgical Rx -2 10 4m 189-131-16 189-231-16 189-132-16 189-232-16

U4, U5 -7 0 2d 189-141-00 189-241-00 189-142-00 189-242-00

U4, U5/dnk -7 0 2d 189-141-10 189-241-10 189-142-10 189-242-10

U4, U5/mhk -7 0 2d 189-141-90 189-241-90 189-142-90 189-242-90

MandibularTooth

L1, L2 -1 2 0 189-311-00 189-411-00 189-312-00 189-412-00

L3 -11 7 2m 189-331-00 189-431-00 189-332-00 189-432-00

L3/hook -11 7 2m 189-331-10 189-431-10 189-332-10 189-432-10

L4 -17 -1 4d 189-341-00 189-441-00 189-342-00 189-442-00

L4/hook -17 -1 4d 189-341-10 189-441-10 189-342-10 189-442-10

L4/offset base -17 -1 4d 189-341-08 189-441-08 189-342-08 189-442-08

L5 -22 -1 4d 189-351-00 189-451-00 189-352-00 189-452-00

L5/hook -22 -1 4d 189-351-10 189-451-10 189-352-10 189-452-10

L5/offset base -22 -1 4d 189-351-08 189-451-08 189-352-08 189-452-08

*The DENTSPLY GAC version of the Roth Prescription is not claimed to be a duplication of any other, nor does DENTSPLY GAC imply that it is endorsed in any way by Dr. Roth.

Page 16: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

SELF-LIGATING BUCCAL TUBES .018 .022Maxillary T A Of Right Left Right Left

U6 Single -10 0 14 88-161-05 88-261-05 88-162-05 88-262-05

U6 Single -14 0 10 88-261-81 88-611-02 88-162-81 88-262-81

U6 Double -20 0 20 88-161-62 88-261-62 88-162-62 88-262-62

Mandibular

L6 Single -25 0 4 88-361-09 88-461-09 88-362-09 88-462-09

L6 Single -20 0 0 88-361-81 88-461-81 88-362-81 88-462-81

L6 Single -14 0 4 88-361-62 88-461-62 88-362-62 88-462-62

L6 Double -10 0 4 88-361-08 88-461-08 88-362-08 88-462-08

Molar Management Traditional Molar tubes are essentially passive attachments. They have four rigid walls that create a tunnel for the archwire to go through. Since molar tubes are generally wide in design (4 mm or more), they can control rotations and tip very well. Also, there is typically no engaging force such as stainless or elastomeric ligatures pressing the wire onto the base of the tube. Therefore an inherent problem with traditional tubes is the lack of torque they are able to express due to their passivity.

This passivity works very well in some stages of treatment mechanics, but torque expression can be very difficult to achieve toward the end of the treatment. Orthodontists are aware of the clinical problems and have developed different ways to manage the molars to obtain proper torque. (i.e TPA, Torquing wires, TADS etc) While these methods are viable, they can be uncomfortable, time consuming, not reliable and or expensive. That is why DENTSPLY GAC offers Self–Ligating buccal tubes as part of the In-Ovation system. Self-Ligating buccal tubes address the need for torque control by utilizing the interactive technology of the In-Ovation system. Also, the SL clip makes wire changes involving hard to reach second molars a simple procedure that takes only seconds.

BI-DIMENSIONALMaxillary .018 .022Tooth T A Of Right Left Right Left

U1 12 5 0 189-111-00 189-211-00

U2 8 9 0 189-121-00 189-221-00

U3/hook 0 7 0 189-132-41 189-232-41

U4, U5 0 0 0 189-542-40 189-542-40

U4, U5/hook 0 0 0 189-142-41 189-242-41

MandibularTooth

L1, L2 -1 0 0 189-611-02 189-611-02

L3/hook 0 5 0 189-332-41 189-432-41

L4, L5 0 0 0 189-642-40 189-642-40

L4, L5/hook 0 0 0 189-342-41 189-442-41

CETLIN/GREENFIELDMaxillary .018 .022Tooth T A Of Right Left Right Left

U1 24 5 0 189-111-03 189-211-03 189-112-03 189-212-03

U2 16 8 0 189-121-03 189-221-03 189-122-03 189-222-03

U3 0 10 0 189-131-03 189-231-03 189-132-03 189-232-03

U3/hook 0 10 0 189-131-13 189-231-13 189-132-13 189-232-13

U4, U5 -7 0 0 189-541-03 189-541-03 189-542-03 189-542-03

U4, U5/hook -7 0 0 189-141-13 189-142-13 189-142-13 189-242-13

MandibularTooth

L1, L2 -6 0 0 189-611-03 189-611-03 189-612-03 189-612-03

L3 -7 5 0 189-331-03 189-431-03 189-332-03 189-432-03

L3/hook -7 5 0 189-331-13 189-431-13 189-332-13 189-432-13

L4 -11 0 0 189-641-03 189-641-03 189-642-03 189-642-03

L4/hook -11 0 0 189-341-13 189-441-13 189-342-13 189-442-13

L5 -15 0 0 189-651-03 189-651-03 189-652-03 189-652-03

L5/hook -15 0 0 189-351-13 189-451-13 189-352-13 189-452-13

Part Art. Part Science. All Orthodontics.™

Page 17: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

121-998-61

Certified In-Ovation System Provider

4.2010 121-999-01

Sentalloy Wire SystemSentalloy wires are the perfect complement to the interactive technology built into In-Ovation brackets. The wires are designed to deliver a gentle, light continuous force; moving teeth without dissipation of force and periodontal stress. The “secret” to Sentalloy is its use of body temperature to activate the characteristics inherent in the wire, to give you superelasticity and shape memory qualities during treatment.

Sentalloy Archwire Options:Sentalloy®Round Initial archwire, round, for leveling and aligning

Neo Sentalloy®Square or Rectangular Intermediate archwire, for early to mid treatment

BioForce®Square or RectangularAn advanced archwire, for early to mid treatment with ideal biological forces

InstrumentsDENTSPLY GAC offers a complete line of instruments to use with In-Ovation R brackets for every phase of treatment.

Engage R ODG88005Engage R Aspel ODG88006In-Ovation R Clip Opener 07-089-01Beaver Tail ODG88001Positioning Tool ODG88002R Tool ODG88004TN3 Bracket Positioner TN3Force Module Aspel ODG510

Practice & Patient SupportWhen you choose In-Ovation R, the benefits go well beyond those of the bracket itself. DENTSPLY GAC realizes that our responsibility doesn’t end when your order ships. We support you with the practice-building solutions of GACPowered.com and our Practice Management Solutions from our partnership with the industry leading Pride Institute. Together with the educational leadership of G-CARE and the tangible savings provided by the UOBG, we make the products and programs that help make you more successful.

• Consultation Models• 10x Model• Patient Brochures• Patient DVD’s• Posters for the Office• Clinical System DVD

• White Papers• Tutorial Site• Doctor Brochure• Rx Brochure• GACPowered Marketing Site

Technique Follows Technology

Genuine

In-Ovation®R

Treat Your Smile Like a Work of Art!Embracing a New You with In-Ovation R

1.75 in x 1.125 in

Dr. Name800.800.1234

Part Art. Part Science. All Orthodontics.

In-Ovation RTechnique Follows Technology

Genuine

Comprehensive Prescription Guide

Consultation Models

Patient DVDDoctor Brochure Patient Brochure In-Office Posters Rx Brochure

Sticker & Window Cling

Dr. Name888.888.8888

121-999-60

T-Shirts

P ti t DVD

YourChoicefor aRadiantSmile!

Page 18: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Case Study 1• 12-year-old female

• Deep bite

• Buccal crossbite of the right side

• Class II canines and crowding

• In-Ovation R appliance was used to level and align, parallel

maxillary and mandibular occlusal planes and provide

optimal buccal crown torque to the maxillary incisors

• Short Class II elastic were used at the working stage

• Treatment time: 25 months

Initial intraoral photos showing the severity of the deep bite, right side buccal crossbite and Class II canines. Notice the lack of inclination of maxillary incisors. In order to level the mandibular occlusal plane, proper inclination of maxillary incisors must be achieved.

In-Ovation R appliance. Upper and lower .019” x .025” SS, lower arch with reverse curve of Spee and short Class II elastics. Parallelism of upper and lower wire has been achieved. Notice proper inclination of maxillary incisors and level curve of Spee.

Finished case. Notice proper intercuspation, Class I molar and canine and proper overjet and overbite. Treatment time: 25 months

Case courtesy of Antonino G. Secchi, DMD, MS Assistant Professor of Orthodontics and Clinical Director of the Department of Orthodontics at the University of Pennsylvania. Private practice Philadelphia, PA.

Part Art. Part Science. All Orthodontics.™

Page 19: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Case Study 2• 14-year-old male

• Blocked canine

• End-on molar relationship

• Midline discrepancy

• In-Ovation R appliance was used with extractions of

maxillary first pre-molar and second mandibular pre-molar

• Minimum anchorage mechanics used

• Treatment time: 20 months

Initial intraoral photos showing maxillary right canine ectopically positioned, end-on molar and canine relationship and maxillary midline off to patient’s right side.

Intraoral photos at the time the In-Ovation R appliance was placed with an upper and lower .014” Sentalloy archwires. Initial alignment was done in 7 months through a sequence of three archwires: .014” Sentalloy, .018” Sentalloy and .020”x.020” Bioforce.

Finished case. Proper intecuspation, Class I molar and canine with proper overjet and overbite. Minimum anchorage mechanics allowed maintaining maxillary and mandibular incisors inclination while protracting mandibular molars to a Class I relationship. Treatment time: 20 months

Case courtesy of Antonino G. Secchi, DMD, MS Assistant Professor of Orthodontics and Clinical Director of the Department of Orthodontics at the University of Pennsylvania. Private practice Philadelphia, PA.

Page 20: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Case Study 1Class I Openbite/Unilateral Crossbite

• 17-year-old male

• Anterior open bite

• Posterior crossbite

• Slightly recessive mandible

• Reverse smile line

• No extractions

• No surgery

• No spurs

• No elastics

Initial malocclusion

7 Months: Stage 2-Maxilla & Mandible .020 x .020 BioForce

14 Months: Stage 3-Maxilla .019 x .025 Resolve “L” loop. Mandible .019 x .025 Resolve

5 Months: Stage 1-Maxilla. Continue with original .018 Sentalloy Stage 2-Mandible. Begin .020 x .020 BioForce

Day of removal, before gnathological positioner is placed - 16 months treatment time, 9 appointments

Case courtesy of Ronald Roncone, DDS, MS Vista, CA. Specializes in adult treatment (esthetics, surgical and TMD) as well as “early” treatment for children. He is a respected and frequent lecturer, and founder of the JSOP program used by practitioners around the world.

Part Art. Part Science. All Orthodontics.™

Page 21: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Case Study 2Class III Non-Extraction

• 14-year-old male

• Unilateral Class III

• TMD

• Recessive upper lip

• Anterior crossbite

Initial malocclusion

Upper: .017 x .025 Resolve • Lower .017 x .025 Resolve

Upper: .019 x .025 Resolve • Lower .019 x .025 Resolve

Upper: .018 Sentalloy • Lower: splint

Day of removal - 14 months treatment time, 6 appointments

Case courtesy of Ronald Roncone, DDS, MS Vista, CA. Specializes in adult treatment (esthetics, surgical and TMD) as well as “early” treatment for children. He is a respected and frequent lecturer, and founder of the JSOP program used by practitioners around the world.

Page 22: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Products“Diagnosis and treatment planning are critical aspects to any case. In-Ovation brackets help me execute my planned goals in the most efficient manner. After testing many brackets, I can tell you that no one can match the consistency I’ve experienced with In-Ovation R and C.”

- Dr. Luis Nelson Nunez, DMD, MS

Opportunity“Successful orthodontists don’t view CE as an obligation, but as an opportunity. The GAC Clinical Alliance for Research & Education, G-CARE, is dedicated to the pursuit of knowledge. G-CARE has a comprehensive approach, offering clinical and business programs at the undergraduate and doctorate level to some of the most thought provoking CE courses”

- Dr. Antonino G. Secchi, DMD, MS

Enhancing Clinical and Business Success When it comes to the products that carry the DENTSPLY GAC name, we are driven by our dedication to quality. We manufacture In-Ovation products to the highest possible standards. This means that you might find a similar bracket, but you’ll never find one that delivers a higher level of clinical confidence.

At DENTSPLY GAC, everything we do is focused on enhancing your clinical and business success through predictable outcomes and practice-development solutions. This extends not only to advanced technologies like the ever evolving In-Ovation line of products, but also in the creation of programs like practice-marketing supersite GACPowered.com, the community-oriented United Orthodontic Buying Group and Comprehensive Education programs through our G-CARE program. Because in shaping the future of orthodontics, we’re able to let you concentrate on that which matters most—reshaping the smiles of individuals the world over.

• We craft high-quality products that improve your clinical performance• We provide outstanding service that supports your specialized work• We are passionate about providing the most relevant and effective Clinical Education• We share your commitment to the best care for the patient and your desire to build your practice through quality treatment

Part Art. Part Science. All Orthodontics.™

Page 23: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Practice“Everyone knows how good the DENTSPLY GAC brackets and auxiliaries are. But the Practice Management Solutions have helped us establish the strategy for our expansion and to maximize the marketing opportunity. They’ve thought of things that I’m not sure we ever would have and the timing couldn’t have been better!”

- Dr. Sam King, DMD, MS

Where Everything Falls Into PlaceWhen all is said and done, the bracket is the fulcrum of every orthodontic treatment; the literal intersection between your talent and your patient. DENTSPLY GAC maintains the utmost production standards—from Computer Numerated Control to Metal Injection Molding—the goal is that every bracket we manufacture meets or exceeds your every expectation. From tie-wings that are engineered for optimal patient comfort to slots made with extremely tight tolerances for consistent and predictable treatment times, there’s a reason that In-Ovation R is one of the most respected brackets available today. This quality is an essential part of our commitment to you, and the patients you treat. From everyone at DENTSPLY GAC, it is our pleasure to partner with you in every patient you treat.

Success“The DENTSPLY GAC University Transition Program enables students to make a smooth transition from the realm of academia to the world of private practice.”

- Dr. Sam A. Winkelmann, DDS

Page 24: Genuine In-Ovation R - Dentsply Sirona · 2020-04-03 · In-Ovation R can offer you benefits that extend well beyond the practice. When you consider everything you can do with more

Part Art. Part Science. All Orthodontics.™

800.645.5530 www.dentsplygac.com

© 2014 DENTSPLY GAC International. All Rights Reserved. 0280-MM-120-089-01 Rev. 01

Clinical Journal Articles“Gaining Control with Self-Ligation”Michael C. Alpern – Seminars in Orthodontics, Vol 14, No 1 (March 2008): pp 73-86

“Measurement of plastic and elastic deformation due to third-order torque in self-ligated orthodontic brackets” Thomas W. Major, Jason P. Carey, David S. Nobes, Giseon Heo, and Paul W. Major Edmonton, AB Canada – American Journal of Orthodontics and Dentofacial Orthopedics, Vol 140, Issue 3 (September 2011)

“Mechanical effects of third-order movement in self-ligated brackets by the measurement of torque expression” Thomas W. Major, Jason P. Carey, David S. Nobes, Giseon Heo, and Paul W. Major Edmonton, AB Canada – American Journal of Orthodontics and Dentofacial Orthopedics, Vol 139, Issue 1 (January 2011)

“Plaque retention by self-ligating vs elastomeric orthodontic brackets: Quantitative comparison of oral bacteria and detection with adenosine triphosphate-driven bioluminescence”Peter Pellegrini, Rebecca Sauerwein, Tyler Finlayson, Jennifer McLeod, David A. Covell, Jr, Tom Maierf and Curtis A. Machida – Portland, OR – American Journal of Orthodontics and Dentofacial Orthopedics, Volume 135, Number 4(April 2009)

White PapersIncreasing Practice Efficiency and Profitability Using In-Ovation® Self-Ligating Brackets by Dr. Jerry Clark Item #120-089-04

Self-Ligation: The Future of Orthodonticsby Dr. Jerry Clark Item #120-089-05

In-Ovation...Fewer Office Visits...Shorter Treatment Time by Dr. Straty Righellis Item #120-089-03

The Practice Pulse™ Program Featuring In-Ovation R Cost Saving Analysisby Dr. Glen Cowan

Text BookInteractive Self-ligation - Orthodontic TechniquesJohn C. Voudouris, DDS, DOrth,MSc (D)M.M. Kuftinec DMD (Harv.), Editor2006 Second ed. - Voudouris, JCISBN 0-9733167

RxOnly

EC REP0120

Emergo Europe Molenstraat 15 2513 BH The Hague, Netherlands