23

GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 2: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

GEC Permit Application 2 Effective 01/12/2021

AREA OF DISTURBANCE: Land disturbing activities include excavation and piles for structures, roadways, septic systems, water lines, utility trenches, cut and fill slopes, stockpiles, building material storage area, etc. A plan level GEC is required for any land disturbance proposed in conjunction with impervious coverage on 41% or more of a site.

Identify the percent of site covered by impervious surfaces.

Below, identify the area of disturbance in each slope interval:

Existing Slope of Area Area to be Disturbed

(sf) Thresholds

Exempt Statement Plan

TOTAL DISTURBANCE See below If disturbing at least 12,000 sf but less than 1 acre.

If disturbing 1 acre or more.

5% or less If disturbing less than 12,000 sf.

If disturbing at least 12,000 sf but less than 1 acre.

If disturbing 1 acre or more.

More than 5% up to 15%

If disturbing less than 1,000 sf.

If disturbing at least 1,000 sf but less than 1 acre.

If disturbing 1 acre or more.

More than 15% No exemption. If disturbing 3,000 sf or less. If disturbing more than 3,000 square feet.

NOTICE: For permits that require a plan-level GEC permit, a pre-application conference is mandatory prior to submitting the GEC application. When requested, a financial surety is required; the applicant shall be responsible for providing a cost estimate for the work requiring the surety. I certify that I have read and examined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this work will be complied with whether specified herein or not. The granting of this permit does not give authority to violate or cancel the provisions of any state or local law regulating grading or the performance thereof.

Signature of Applicant Date

Print Name Title

For Office Use Only

Planning Sufficiency declared by: Date:

Planning Review conducted by : Date:

Questions about GEC Permit Applications, design plans and any supporting documents should be directed to the Planning

Department (307-733-3959) or Engineering Department (307-733-3317).

DocuSign Envelope ID: 3149CE03-D840-452C-AFD7-393BDEB47FDB

Christopher Swann

390,744

35%

02/19/2021

Managing Member

Page 3: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

GEC Permit Application 3 Effective 01/12/2021

1. One set of complete GEC drawings scaled on 11” x 17” paper.

2. One PDF set of scaled drawings and GEC application with all other attachments emailed to [email protected](no larger than 25MB)

3. Letter of Authorization if the applicant is other than the property owner.

4. A copy of the Warranty Deed or Contract of Sale.

5. A fee due at the time of submittal – Public Works Fee Schedule

6. Site Development schedule - month and year of project initiation to completion of re-vegetation.

7. Proposed grading plan to include:

- existing contours- proposed contours- extent of disturbance- stockpile location(s)

8. Re-vegetation details for all disturbed areas to include:- types and approximate location of vegetation to be used- seeding or planting and stabilization techniques to be followed

- source and method of irrigation, if necessary

9. Erosion control plan to include:- drawing and specifications illustrating the type and location of required erosion control measures

(silt fences, straw bales, detention basins, duff berms, etc.)

- direction of runoff throughout the construction area and the re-contoured area

10. Weed & Pest language to include:- references to Wyoming Seed Law and Wyoming Nursery Stock Law- invasive Species Management Plan

11. Ponds/Water features. Ponds and water features with a pump system are required to pay a fee of$150 per horsepower per the Energy Mitigation Program.

12. Retaining wall (LDRs 5.72.-B.4)- must be certified by a Licensed Wyoming Professional Engineer

13. Work in Live Waterbodies ($50/day during work in water or discharge)

Applicant Check All GEC applications shall include the following: Planning Check

In addition to all the above items, plan-level applications shall include the following: 14. Drawings prepared and stamped by a Wyoming-registered professional engineer or landscape

architect.15. Existing conditions site plan to include:

- Site boundaries and contiguous lands- Watercourses – lakes, streams, wetlands, ditches, etc.- Floodplains- Landslide or bedrock slum (talus and/or avalanche slopes- Predominant soil types – location and identification- Vegetation cover – location and species- Stormwater drainage and/or natural drainage patterns (locations and dimensions)- Utilities and other structures – buildings and paved areas

- Site topographic map

16. Plan of final site conditions showing the site changes at the same scale as the existing conditions site

plan.

17. Site Construction Plans- Land disturbing activities-locations and dimensions- Temporary topsoil/dirt stockpile-location and dimensions- Plans and sections of grading features- Engineering technique to minimize adverse effect of geologic or flood conditions- Site storm water management and erosion control measures- Starting and completion date of land disturbances/land development activity- Maintenance of site erosion control measures

- Geotechnical report on slopes in excess of 30%

SUBMITTAL REQUIREMENTS: Please fill out the left side of this checklist. Staff will review this for Sufficiency. Reference LDR 5.7 & 8.3.4 for questions regarding this application.

DocuSign Envelope ID: 3149CE03-D840-452C-AFD7-393BDEB47FDB

X

X

X

X

N/A

X

X

N/A

X

X

X

X

N/A

X

X

X

X

Page 4: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

 

February 23, 2021  Hamilton Smith Principal Planner Teton County Planning Department 210 South Willow Street Jackson, WY 83001  RE:  Submittal for Revision #1 to Grading and Erosion Control Permit (GEC2019‐0102) for Phase 3 & 4 at Lots 1‐

20, The Lodge Cabin Townhomes at Snake River Canyon Ranch Resort(SRCRR), Plat No. 1409  Dear Hamilton,  Between approval of GEC 2019‐0102 and now, there have been several changes that have come to light during the building permit submittal process for Phase 3 & 4 of SRCRR. One was that the fire turnarounds were removed. The Fire Marshall approved  this  removal  thus  reducing  the  complexity of  the  site  since all  the units are now specified with sprinklers. Ted Van Holland approved just this change as a “minor deviation” from his department during our surety reduction process. However, his direction was that all other changes that were revealed during the building permit process needed to be approved in a formal revision the permit.   These changes detailed in this revision and all subsequent revisions here forward were not possible to completely understand during the DEV process or original submittal of the grading. They were revealed via technical review each unit in fine detail (< 1 ft grading, etc.) to ensure all the uses and aesthetics are addressed appropriately on each unit.   This submittal represents Revision #1 which contains the south  leg of units, specifically Lodge Cabins 208, 209, 210, 211, 212, 213, 214, 215, 216 (aka lots 8‐16).  Revision #2 will contain all changes around the Lodge (Phase 4) and Revision #3 will contain the remaining Lodge Cabins on the north leg, specifically Lodge Cabins 201, 202, 203, 204, 205, 206, 207, 217, 218. Both will be submitted subsequent Revision #1.   With this letter you will find:  

GEC Application 

Quitclaim Deed, General Warranty Deed, and Assignment of Rents 

Jorgensen Associates, Inc. Revision #1 GEC Drawings for Snake River Canyon Ranch Resort Phases 3 & 4  

Jorgensen Associates, Inc. Check for $350  Please contact me with any questions, concerns, or if you require additional information to process the request.  Sincerely,    Brendan Schulte Senior Project Manager   JORGENSEN ASSOCIATES, INC.  

Page 5: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 6: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 7: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 8: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 9: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 10: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 11: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 12: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 13: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 14: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 15: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC
Page 16: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

8

±5855.5

9

±5858

10

±5861

11

±5864.5

12

±5872

13

M

AIN

±5885.5

LO

W

ER

±5875.5

14

M

AIN

±5888.5

LO

W

ER

±5878.5

1

5

M

A

I

N

±

5

8

7

1

.

5

L

O

W

E

R

±

5

8

6

1

.

5

1

6

M

A

I

N

±

5

8

7

9

.

5

L

O

W

E

R

±

5

8

6

9

.

5

5

8

8

5

5

8

9

0

5

8

9

5

5

9

0

0

5

9

0

5

5

9

1

0

5915

5

8

9

0

5

8

9

5

5

9

0

0

5

9

0

5

5860

5865

5

8

7

0

5

8

7

5

5

8

8

0

5

8

8

5

5

8

9

0

5895

Plotted by P

Yantzi on F

eb 23, 2021 - 12:23pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.0 O

VE

RV

IE

W_R

EV

IS

IO

NS

.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.0

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

TIT

LE

, S

HE

ET

IN

DE

X &

R

EV

IS

IO

N

OV

ER

VIE

W

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

LODGE - PHASE 4

EDGE OF PHASE

3 AND 4 LOTS

W

A

G

O

N

R

O

A

D

LE

A

D

ER

LA

N

E

C

A

D

D

I

S

C

O

U

R

T

PROPERTY

BOUNDARY

CABIN (TYPICAL)

NATIONAL FOREST

SHREIAR FAMILY TRUST

SNAKE RIVER BEND

RANCH, LLC

PHASE TWO

5 FT SETBACK

LIMITS OF DISTURBANCE

AVALANCHE RED ZONE

AVALANCHE RED ZONE

AVALANCHE BLUE ZONE

AVALANCHE BLUE ZONE

BOULDER

RETAINING WALL

(TYPICAL)

P

H

3

S

.

A

C

C

E

S

S

R

D

PH

3 L

OT

S 13-14

AC

CE

SS

R

D

NOTES:

LODGE - PHASE 4 GRADING NOT A

PART OF THIS REVISION.

NET FILL OF +3875 CY ON PERMIT

GEC 2019-0102 INCREASED +3120 CY

TO NET FILL +6995 CY THIS REVISION.

1

1

1

ENGINEER, SURVEYOR, AND

LAND PLANNER

Jorgensen Associates, Inc.

1315 S. Highway 89, #201

P.O. Box 9550

Jackson, WY 83002-9550

(307) 733-5150

OWNER

SRSC Lots, LLC

3060 Peachtree RD NW

STE 1080

Atlanta, GA 30305-2251

(307) 201-2560

INDEX OF SHEETS

Sheet

No.

Sheet Title

C3.0

TITLE, SHEET INDEX & REVISION OVERVIEW

C3.3 PHASE 3 SOUTH GRADING

C3.5 SOUTH ACCESS ROAD

C3.7 SOUTH STORM SEWER

C3.8 GRADING DETAILS

C3.9 GRADING DETAILS

C3.10 GRADING DETAILS

C3.11 GRADING DETAILS

SNAKE RIVER CANYON RANCH RESORT

PHASES 3 & 4

GRADING AND EROSION CONTROL

PERMIT NO. GEC 2019-0102

REVISION 1

LOTS 1-6 SNAKE RIVER SPORTING CLUB, PLAT NO. 1165

LOCATED WITHIN

NE

1

4

SECTION 8,

T38N, R116W, 6TH P.M.

TETON COUNTY, WYOMING

AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
SCALE: 1 INCH = FEET
AutoCAD SHX Text
0
AutoCAD SHX Text
THIS SCALE VALID ONLY FOR PRINTS
AutoCAD SHX Text
50
AutoCAD SHX Text
22x34
AutoCAD SHX Text
50
AutoCAD SHX Text
100
AutoCAD SHX Text
150
Page 17: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

FFE 5849.36

FFE 5855.34*

FFE 5855.00

1.5

%

1.5%

2

.0

%

5

.0

%

2

.

0

%

3

.0

%

2

.0

3

%

1

.0

%

+ 5849.61

1.5

%

1.5%

2

.0

%

5

.0

%

2

.

0

%

3

.0

%

2

.0

3

%

1

.0

%

+ 5

854.2

5

+ 5855.25

+ 5849.25

+ 5853.00

8

±5855.5

9

±5858

10

±5861

11

±5864.5

12

±5872

13

M

AIN

±5885.5

LO

W

ER

±5875.5

14

M

AIN

±5888.5

LO

W

ER

±5878.5

1

5

M

A

I

N

±

5

8

7

1

.

5

L

O

W

E

R

±

5

8

6

1

.

5

1

6

M

A

I

N

±

5

8

7

9

.

5

L

O

W

E

R

±

5

8

6

9

.

5

5

8

8

5

5

8

9

0

5

8

9

5

5

9

0

0

5

9

0

5

5

9

1

0

5915

5

8

9

0

5

8

9

5

5

9

0

0

5

9

0

5

5860

5865

5

8

7

0

5

8

7

5

5

8

8

0

5

8

8

5

5

8

9

0

5895

5860

5865

5

8

7

0

5

8

7

5

5

8

8

0

5855

5860

5865

5

8

7

0

5

8

6

0

5

8

6

5

5

8

7

0

5

8

7

5

5

8

8

0

5

8

8

5

5

8

8

5

5

8

8

0

5

8

5

5

5

8

8

0

5

8

5

0

5

8

5

0

5

8

5

0

5

8

6

0

5

8

6

5

±5856.0

5

8

8

0

5

8

7

0

5870

5

8

6

0

5

8

5

5

R

I

M

5

8

5

1

.

9

3

5849.33

5

8

5

0

.

6

7

5

8

5

0

.

4

6

5

8

5

2

.

5

2

5

8

5

2

.

3

0

5

8

5

4

.

2

2

TW

5879.49

TW

5876.06

5

8

7

8

.

4

8

5

8

7

8

.

4

2

TW

5885.50

TW

5879.02

5

8

7

3

.9

9

TW

5883.50

5

8

7

8

.

3

6

5

8

7

6

.

4

4

5

8

7

5

.

4

9

5

8

7

7

.

7

6

5

8

8

2

.

7

5

5861.66

5

8

7

0

.

4

6

5

8

7

1

.

5

0

5

8

7

0

.

4

9

5

8

6

3

.

1

3

5

8

6

4

.

4

0

5

8

7

1

.

8

7

5

8

5

9

.

7

1

5

8

6

0

.

9

4

5

8

5

9

.

6

4

5

8

6

0

.

0

0

5

8

6

4

.

5

0

5

8

6

4

.

1

3

5

8

7

0

.

6

2

5

8

6

9

.

7

7

5

8

6

4

.

7

1

5

8

6

2

.

8

5

5

8

6

3

.

4

2

5

8

6

0

.

7

7

5

8

6

0

.

4

0

5

8

5

9

.

2

9

5

8

5

7

.

9

0

5

8

5

4

.

0

0

5

8

5

6

.

5

0

5

8

5

4

.

3

9

5

8

5

7

.

8

0

5

8

5

5

.

5

0

5

8

5

7

.

0

0

5

8

5

7

.

3

4

5

8

5

5

.

0

8

5

8

5

4

.

7

7

5

8

5

4

.

1

5

5

8

6

1

.

4

9

TW

5870.00

5

8

5

8

.

5

0

5

8

5

6

.

0

5

5

8

5

8

.

5

6

5862.43

5864.99

5864.52

5

8

6

9

.

4

8

5

8

7

6

.

9

2

5

8

5

5

.

7

5

5

8

6

9

.6

3

TW

5870.25

TW

5863.00

5

8

6

1

.

4

1

5867.30

5868.47

5860.81

TW

5871.25

TW

5877.75

5

8

6

9

.

3

8

TW

5878.00

5

8

7

4

.

6

9

TW

5886.50

5

8

4

9

.

0

1

TW

5874.81

5

8

7

1

.

5

5

3:1

3:1

5:1

-

1

3

.0

%

2

:

1

6

:1

18

:1

-

8

.

2

%

3

:

1

S

W

A

L

E

S

W

A

L

E

S

W

A

L

E

S

W

A

L

E

SW

ALE

3

:

1

4:1

2:1

2

:

1

3:1

-

1

5

.

0

%

-10.3%

4

:1

5:1

Plotted by P

Yantzi on F

eb 23, 2021 - 12:24pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.0-3.5 G

RA

DIN

G.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.3

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

PH

AS

E 3 S

OU

TH

G

RA

DIN

G

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

EDGE OF PHASE

3 AND 4 LOTS

W

A

G

O

N

R

O

A

D

C

A

D

D

IS

C

O

U

R

T

EDGE OF PHASE

3 AND 4 LOTS

AVALANCHE RED ZONE

CABIN (TYPICAL)

NATIONAL FOREST

SHREIAR FAMILY TRUST

SRS CLUB, LLC

PHASE TWO

STORM WATER

DETENTION AREA

(8000 CF PROVIDED)

5 FT SETBACK

LIMITS OF DISTURBANCE

AVALANCHE RED ZONE

AVALANCHE BLUE ZONE

5 FT SETBACK

APPROXIMATELY 650 LF

SILT FENCE ALONG

WESTERN LIMITS OF

DISTURBANCE

P

H

3

S

.

A

C

C

E

S

S

R

D

R20.0'

R20.0'

R20.0'

PUTTING GREEN

(TEMPORARY TOPSOIL STORAGE AREA)

STRAW WATTLE TO BE PLACED

ON EITHER SIDE OF ACCESS IN

DRAINAGE DITCHES ALONG

WAGON ROAD

LIMITS OF DISTURBANCE

CMP CULVERT (TYPICAL)

SEE STORM SEWER

DESIGN FOR SIZE

AND TYPE

BOULDER

RETAINING WALL

MAX HEIGHT 10'

(TYPICAL)

BOULDER

RETAINING WALL

MAX HEIGHT 4'

(TYPICAL)

CONCRETE

AVALANCHE

WALL

CONCRETE

RETAINING

WALL

(TYPICAL)

AVALANCHE BLUE ZONE

LODGE- PHASE 4

NOT A PART OF THIS

REVISION

AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
SCALE: 1 INCH = FEET
AutoCAD SHX Text
0
AutoCAD SHX Text
THIS SCALE VALID ONLY FOR PRINTS
AutoCAD SHX Text
30
AutoCAD SHX Text
22x34
AutoCAD SHX Text
30
AutoCAD SHX Text
60
AutoCAD SHX Text
90
Page 18: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

LINE TABLE

LINE #

L6

L7

L8

L9

BEGIN STA.

0+00

1+05

1+79

0+00

END STA.

0+44

1+65

2+57

0+24

LENGTH

44.00

60.18

78.58

23.68

DIRECTION

S83° 01' 52"E

S51° 29' 43"E

S88° 02' 40"E

N42° 08' 30"E

ALIGNMENT NAME

PH3 SOUTH ACCESS RD REV

PH3 SOUTH ACCESS RD REV

PH3 SOUTH ACCESS RD REV

PH 3 LOTS 13-14 ACCESS RD

CURVE TABLE

CURVE #

C5

C6

C7

C8

C9

C10

C11

C12

PC

0+44

0+66

1+65

2+57

3+11

0+24

0+64

0+79

PT

0+66

1+05

1+79

3+11

3+19

0+64

0+79

1+38

RADIUS

111

110

26

112

12

101

101

100

LENGTH

22.15

38.72

13.83

53.45

8.01

40.16

15.51

58.20

DELTA ANGLE

011° 32' 18"

020° 10' 06"

030° 52' 05"

027° 28' 38"

040° 26' 49"

023° 00' 27"

008° 53' 04"

033° 20' 39"

ALIGNMENT NAME

PH3 SOUTH ACCESS RD REV

PH3 SOUTH ACCESS RD REV

PH3 SOUTH ACCESS RD REV

PH3 SOUTH ACCESS RD REV

PH3 SOUTH ACCESS RD REV

PH 3 LOTS 13-14 ACCESS RD

PH 3 LOTS 13-14 ACCESS RD

PH 3 LOTS 13-14 ACCESS RD

8

±5855.5

9

±5858

10

±5861

11

±5864.5

12

±5872

13

M

AIN

±5885.5

LO

W

ER

±5875.5

14

M

AIN

±5888.5

LO

W

ER

±5878.5

1

5

M

A

I

N

±

5

8

7

1

.

5

L

O

W

E

R

±

5

8

6

1

.

5

1

6

M

A

I

5

8

7

9

.

5

L

O

W

E

R

±

5

8

6

9

.

5

5

8

8

5

5

8

9

0

5

8

9

5

5

9

0

0

5860

5865

5

8

7

0

5

8

7

5

5

8

8

0

5

8

8

5

5

8

9

0

5895

5860

5865

5

8

7

0

5

8

7

5

5

8

8

0

5855

5

8

6

0

5865

5

8

7

0

5

8

6

0

5

8

6

5

5

8

7

0

5

8

7

5

5

8

8

5

5

8

8

0

5

8

5

5

5

8

8

0

0

+

0

0

0

+

5

0

1+

00

1+

50

2

+

0

0

2

+

5

0

3

+

0

0

3

+

1

9

0+00

0

+

5

0

1

+

0

0

1+38

L

6

L7

L

8

C

5

C

6

C

7

L9

C

1

0

C

1

1

C

1

2

±5856.0

5

8

8

0

5

8

7

0

C

8

C9

5870

5

8

6

0

5

8

5

5

=PROFILE=

PH3 SOUTH ACCESS RD REV

SCALE: HORIZONTAL. 1"=20'

VERTICAL 1"=4'

5846

5850

5860

5870

5880

5846

5850

5860

5870

5880

0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+19

2.2

7%

9

.

7

9

%

8

.

8

4

%

3

.3

4

%

PVI STA:1+58.32

PVI ELEV:5856.22

K:23.43

LVC:176.27

BV

CS

: 0

+7

0.1

9

BV

CE

: 5

85

4.2

1

EV

CS

: 2

+4

6.4

5

EV

CE

: 5

86

4.8

5

=PROFILE=

PH 3 LOTS 13-14 ACCESS RD

SCALE: HORIZONTAL. 1"=20'

VERTICAL 1"=4'

5850

5860

5870

5880

5850

5860

5870

5880

0+00 0+50 1+00 1+38

1

0

.

3

3

%

1

3

.

2

0

%

1

5

.

0

0

%

PVI STA:0+57.51

PVI ELEV:5865.86

K:3.17

LVC:20.10

BV

CS

: 0

+4

7.4

6

BV

CE

: 5

86

4.5

3

EV

CS

: 0

+6

7.5

5

EV

CE

: 5

86

6.5

5

PVI STA:0+18.93

PVI ELEV:5860.76

K:7.83

LVC:22.49

BV

CS

: 0

+0

7.6

9

BV

CE

: 5

85

9.6

0

EV

CS

: 0

+3

0.1

8

EV

CE

: 5

86

2.2

5

PVI STA:0+74.77

PVI ELEV:5867.04

K:2.05

LVC:14.43

BV

CS

: 0

+6

7.5

5

BV

CE

: 5

86

6.5

5

EV

CS

: 0

+8

1.9

8

EV

CE

: 5

86

8.0

4

LO

T #

13

C

L

ST

A 0

+6

4 L

T 1

0'

LO

T #

8 C

L

ST

A 0

+6

6 R

T 3

6'

LO

T #

9 C

L

ST

A 1

+3

1 R

T 4

4'

LO

T #

15

C

L

ST

A 1

+7

2 L

T 2

4'

LO

T #

10

C

L

ST

A 1

+9

6 R

T 4

1'

LO

T #

11

C

L

ST

A 2

+4

1 R

T 4

5'

LO

T #

16

C

L

ST

A 2

+4

1 L

T 1

0'

LO

T #

12

C

L

ST

A 3

+1

9 R

T 3

0'

EXISTING GROUND

FINISHED GRADE

EXISTING GROUND

FINISHED GRADE

Plotted by P

Yantzi on F

eb 23, 2021 - 12:24pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.0-3.5 G

RA

DIN

G.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.5

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

SO

UT

H A

CC

ES

S R

OA

D

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

P

H

3

S

.

A

C

C

E

S

S

R

D

R

E

V

EDGE OF ASPHALT

PAVEMENT

(TYPICAL)

LIMITS OF

DISTURBANCE

DRIVEWAY (TYP.)

SLOPED MIN. 2%

BACK TO ROADWAY

10.0'

12.0'

10.0'

12.0'

15.0'

10.0'

16.0'

10.0'

15.0'

12.0'

12.0'

10.0'

16.0'

21.5'

21.5'

12.0'

10.0'

12.0'

10.0'

12.0'

12.0'

20.0'

30.0'

10.0'

17.0'

19.0'

4.0'

4.0'

12.0'

12.0'

20.0'

R10.0'

R20.0'

R20.0'

PH. 3 LOTS 13-14

ACCESS RD.

20' WIDE CROWNED

ROAD (TYPICAL)

LODGE - PHASE 4

NOT A PART OF

THIS REVISION

AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
SCALE: 1 INCH = FEET
AutoCAD SHX Text
0
AutoCAD SHX Text
THIS SCALE VALID ONLY FOR PRINTS
AutoCAD SHX Text
30
AutoCAD SHX Text
22x34
AutoCAD SHX Text
30
AutoCAD SHX Text
60
AutoCAD SHX Text
90
Page 19: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

5

8

8

5

5

8

9

0

5

8

9

5

5860

5865

5

8

7

0

5

8

7

5

5

8

8

0

5

8

8

5

5

8

9

0

5895

2

.0

%

3

.0

%

2.03%

1

.0

%

2

.0

%

3

.0

%

2.03%

1

.0

%

0

+

0

0

0

+

5

0

1

+

0

0

1

+

5

0

2+

00

2+

50

3

+

0

0

3

+

5

0

4

+

0

0

4

+

3

7

1

+

5

3

0+00

0+

50

1

+

0

0

1

+

5

0

STA 0+00

SOUTH STORM MAIN 1

INVERT = 5849.01'

STA 0+80

30" INLET

30"Ø CATCH BASIN

STA 1+23

30" INLET

30"Ø CATCH BASIN

STA 1+63

30" INLET

30"Ø CATCH BASIN

STA 2+00 SOUTH STORM 1

STA 0+00 SOUTH STORM 2

30" INLET

48"Ø CATCH BASIN

STA 2+64

30" INLET

30"Ø CATCH BASIN

STA 4+37

30" INLET

30"Ø CATCH BASIN

STA 3+65

30" INLET

30"Ø CATCH BASIN

STA 3+16

30" INLET

30"Ø CATCH BASIN

STA 0+40 STORM 2

30" INLET

30"Ø CATCH BASIN

STA 0+87 STORM 2

30" INLET

30"Ø CATCH BASIN

STA 1+53 STORM 2

30" INLET

30"Ø CATCH BASIN

=PIPE PROFILE=

SOUTH STORM MAIN 1

SCALE: HORIZONTAL. 1"=30'

VERTICAL 1"=6'

5840

5842

5844

5846

5848

5850

5852

5854

5856

5858

5860

5862

5864

5866

5868

5870

5872

5874

5876

5878

5880

5840

5842

5844

5846

5848

5850

5852

5854

5856

5858

5860

5862

5864

5866

5868

5870

5872

5874

5876

5878

5880

0+00 0+25 0+50 0+75 1+00 1+25 1+50 1+75 2+00 2+25 2+50 2+75 3+00 3+25 3+50 3+75 4+00 4+25 4+50

=PIPE PROFILE=

SOUTH STORM MAIN 2

SCALE: HORIZONTAL. 1"=30'

VERTICAL 1"=6'

5840

5842

5844

5846

5848

5850

5852

5854

5856

5858

5860

5862

5864

5866

5868

5870

5872

5874

5876

5878

5880

5840

5842

5844

5846

5848

5850

5852

5854

5856

5858

5860

5862

5864

5866

5868

5870

5872

5874

5876

5878

5880

0+00 0+25 0+50 0+75 1+00 1+25 1+50 1+75

EXISTING

GROUND

EXISTING

GROUND

FINISHED GRADE

FINISHED

GRADE

IN

V IN

: 5

85

0.7

0' 1

2"

IN

V IN

: 5

85

0.7

0' 1

2" M

AIN

1

IN

V O

UT

: 5

85

0.6

0' 1

8" M

AIN

1

ST

A 0

+0

0 S

OU

TH

M

AIN

1

C

ON

NE

CT

IO

N

RIM

: 5

85

3.8

9'

IN

V O

UT

(N

W): 5

85

1.5

1' 1

2"

IN

V IN

(S

): 5

85

1.6

1' 1

2"

IN

V IN

(N

E): 5

85

2.6

1' 1

2"

ST

A 0

+4

0

RIM

: 5

85

4.2

8'

IN

V O

UT

: 5

85

5.2

6' 1

2"

IN

V IN

: 5

85

5.3

6' 1

2"

ST

A 0

+8

7

RIM

: 5

85

8.7

6'

IN

V O

UT

: 5

86

1.3

8' 1

2"

ST

A 1

+5

3

RIM

: 5

86

4.8

8'

38LF, 12" HDPE PIPE

S=2.1%

46LF, 12" HDPE PIPE

S=8.2%

66LF, 12" HDPE PIPE

S=9.4%

IN

V O

UT

: 5

84

8.9

4' 1

8"

IN

V IN

: 5

84

8.9

4' 1

8"

ST

A 1

+2

3

RIM

: 5

85

2.5

3'

IN

V O

UT

: 5

84

9.5

9' 1

8"

IN

V IN

: 5

84

9.5

9' 1

8"

ST

A 1

+6

3

RIM

: 5

85

2.3

1'

IN

V O

UT

: 5

85

0.6

0' 1

8"

IN

V IN

: 5

85

0.7

0' 1

2"

IN

V IN

: 5

85

0.7

0' 1

2" M

AIN

2

ST

A 2

+0

0 S

OU

TH

M

AIN

2

C

ON

NE

CT

IO

N

RIM

: 5

85

3.8

9'

IN

V O

UT

: 5

85

3.4

8' 1

2"

IN

V IN

: 5

85

3.5

8' 1

2"

ST

A 2

+6

4

RIM

: 5

85

6.9

8'

IN

V O

UT

: 5

85

7.1

9' 1

2"

IN

V IN

: 5

85

7.2

8' 1

2"

ST

A 3

+1

6

RIM

: 5

86

0.6

9'

IN

V O

UT

: 5

86

1.2

5' 1

2"

IN

V IN

: 5

86

1.3

5' 1

2"

ST

A 3

+6

5

RIM

: 5

86

4.7

5'

IN

V O

UT

: 5

86

7.8

4' 1

2"

ST

A 4

+3

7

RIM

: 5

87

0.9

7'

37LF, 18" HDPE PIPE

S=1.8%

35LF, 18" HDPE PIPE

S=2.9%

62LF, 12" HDPE PIPE

S=4.5%

52LF, 12" HDPE PIPE

S=7.3%

46LF, 12" HDPE PIPE

S=8.7%

IN

V O

UT

: 5

84

8.7

8' 1

8"

IN

V IN

: 5

84

8.7

8' 1

8"

ST

A 0

+8

0

RIM

: 5

85

2.0

0'

6" S

EW

ER

M

AIN

IN

V: 5

85

5.1

4'

ST

A 3

+5

5

8" W

AT

ER

M

AIN

IN

V: 5

84

6.2

4'

ST

A 0

+2

2

SE

WE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 1

+0

3

WA

TE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 1

+0

8

SE

WE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 1

+4

6

WA

TE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 1

+9

3

SE

WE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 2

+0

9

WA

TE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 2

+6

1

SE

WE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 2

+7

6

WA

TE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 3

+2

1

SE

WE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 3

+3

1

WA

TE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 3

+7

0

SE

WE

R S

ER

VIC

E

VE

RIF

Y D

EP

TH

ST

A 3

+8

1

79LF, 18" HDPE PIPE

S=0.4%

41LF, 18" HDPE PIPE

S=0.4%

70LF, 12" HDPE PIPE

S=10.8%

6" S

EW

ER

M

AIN

IN

V: 5

84

5.5

5'

ST

A 1

+1

5

6" S

EW

ER

M

AIN

IN

V: 5

84

7.5

4'

ST

A 0

+0

6

Plotted by P

Yantzi on F

eb 23, 2021 - 12:25pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.6-3.7 S

TO

RM

S

EW

ER

.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.7

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

SO

UT

H S

TO

RM

S

EW

ER

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

EDGE OF PHASE 3 AND 4

LOTS

W

A

G

O

N

R

O

A

D

EDGE OF PHASE 3 AND 4 LOTS

CABIN (TYPICAL)

NATIONAL FOREST

SRS CLUB, LLC

LODGE - PHASE 4

NOT A PART OF

THIS REVISION

34 LF 21"X15"

ARCHED CMP

INV. IN: 5850.45'

INV. OUT: 5849.33'

STORM WATER

DETENTION AREA

(8000 CF PROVIDED)

PUTTING

GREEN

LIMITS OF DISTURBANCE

5 FT SETBACK

STA 3+81

SEWER SERVICE CROSSING

VERIFY DEPTH

STA 3+70

WATER SERVICE CROSSING

VERIFY DEPTH

STA 3+58

6" SEWER MAIN CROSSING

VERIFY DEPTH

STA 3+31

SEWER SERVICE CROSSING

VERIFY DEPTH

STA 3+21

WATER SERVICE CROSSING

VERIFY DEPTH

STA 2+76

SEWER SERVICE CROSSING

VERIFY DEPTH

STA 1+15

6" SEWER MAIN CROSSING

VERIFY DEPTH

STA 2+61

WATER SERVICE CROSSING

VERIFY DEPTH

STA 2+09

SEWER SERVICE CROSSING

VERIFY DEPTH

STA 1+93

WATER SERVICE CROSSING

VERIFY DEPTH

STA 1+46

SEWER SERVICE CROSSING

VERIFY DEPTH

STA 1+08 STORM 2

WATER SERVICE CROSSING

VERIFY DEPTH

STA 1+03 STORM 2

SEWER SERVICE CROSSING

VERIFY DEPTH

STA 0+22 STORM 2

8" WATER MAIN CROSSING

VERIFY DEPTH

STA 0+06 STORM 2

6" SEWER MAIN CROSSING

VERIFY DEPTH

VEGETATED GRASS OR

ROCK LINING IN DRAINAGE

INTERCEPTOR DITCHES

(TYPICAL)

STA 0+20

2" FORCE MAIN CROSSING

(PHASE 4) VERIFY DEPTH

FLOW ARROW

(TYPICAL)

60 LF 21"X15"

ARCHED CMP

INV. IN: 5857.66'

INV. OUT: 5857.30'

NOTES:

1. STORM SEWER PIPING TO BE N-12 SMOOTH

CORE HDPE. SIZE ACCORDING TO PLANS.

2. USE PIPE DEFLECTION TO ACCOUNT FOR

MINOR DEVIATIONS FROM ALIGNMENT.

LOT 13

LOT 15

LOT 16

LOT 8

LOT 9

LOT 10

LOT 11

LOT 12

LOT 14

17 LF 12" CMP

INV IN: 5868.32'

INV OUT: 5868.00'

MIN. 2% SLOPE

32LF 18" CMP

IE IN: 5864.25'

IE OUT: 5863.61'

30"Ø INLET WITH 30" Ø

CATCH BASIN

RIM: 5855.70'

INV OUT: 5853.70' 12"

110 LF 12" N-12 HDPE

AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
U
AutoCAD SHX Text
CO
AutoCAD SHX Text
U
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
U
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
SCALE: 1 INCH = FEET
AutoCAD SHX Text
0
AutoCAD SHX Text
THIS SCALE VALID ONLY FOR PRINTS
AutoCAD SHX Text
30
AutoCAD SHX Text
22x34
AutoCAD SHX Text
30
AutoCAD SHX Text
60
AutoCAD SHX Text
90
Page 20: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

36"

48"

72"

FRONT VIEW

1 1/4" x 1 1/4" x 48"

HARDWOOD STAKES

ATTACHED TO SILT FENCE

AT 6' O.C.

MANUFACTURED SILT

FENCE, 100 LF ROLL WITH

STAKES ATTACHED

2"

10' MIN. TO TOE OF SLOPE

26"

22"

4"

EXISTING GRADE

1 1/4" x 1 1/4" x 48"

HARDWOOD STAKES

ATTACHED TO SILT FENCE

AT 6' O.C.

MANUFACTURED SILT

FENCE, 100 LF ROLL

WITH STAKES ATTACHED

24"

8"

BACKFILL EXCAVATED

MATERIAL OVER FABRIC

SIDE VIEW

NOT TO SCALE

MANUFACTURED SILT FENCE DETAIL

18", TYP

PLACE STAKES AT ENDS,

BREAK IN GRADE AND EVERY 18"

STAKE AND ENTRENCH

(3" MIN.) STRAW WADDLE

COMPACT SOIL TO

PREVENT PIPING

2"x2"x3" WOOD

STAKE

6" MIN

DIRECTION OF FLOW

FRONT VIEW

SECTION VIEW

NOTE

1. WATTLES LOCATED IN AREAS WHERE RUNOFF IS COLLECTED BEFORE LEAVING THE

SITE. AREAS SHOWN ON THE PLANS MAY BE ADJUSTED BY ENGINEER TO LOCATE

EROSION PROTECTION IN AREAS OF MAXIMUM BENEFIT. WHERE SPACE ALLOWS,

PLACE WATTLES IN TWO ROWS SPACED 5' APART.

NOT TO SCALE

STRAW WATTLE BARRIER

USE TYPE 'A' BACKFILL

AT ALL TRAVELED AREAS

TOP SOIL

BACKSLOPE TO

CONFORM TO O.S.H.A.

REGULATIONS

TYPE 1 EXCAVATION

TYPE I PIPE BEDDING

MATERIAL

2" RIGID INSULATION ABOVE PIPE

PER SITE PLAN

(TYPE A INSULATION)

TYPE 2 PIPE BEDDING

REQUIRED FOR SOFT OR

UNSTABLE FOUNDATION

SUBGRADE

VERTICAL TRENCH WALLS

WITH SHORING TO CONFORM

TO O.S.H.A. REGULATIONS

TYPE 2 EXCAVATION

MINIMUM OF 6"

TYPE "A" OR "B"

TRENCH

BACKFILL. TYPE

"A' BACKFILL

SHALL BE

COMPACTED TO

95% OF

STANDARD

PROCTOR

(AASHTO T-99)

TRENCH WIDTH

PIPE DIA.

6"

6"

NOT TO SCALE

TYPICAL TRENCH DETAIL

(4")

3

4

" CRUSHED BASE

GRADING H

3" ASPHALT

12' DRIVEWAY

2%

CROWN

2%

CROWN

2

:

1

12" SUB-BASE

PITRUN (6" MINUS)

TOP

SOIL

F

I

L

L

S

L

O

P

E

T

O

P

S

O

I

L

C

U

T

S

L

O

P

E

NOT TO SCALE

DRIVEWAY SECTION DETAIL

2

:

1

(4")

3

4

" CRUSHED BASE

GRADING H OR W

3" ASPHALT

20' ROAD

2%

CROWN

2%

CROWN

T

O

P

S

O

I

L

C

U

T

S

L

O

P

E

2

:

1

12" SUB-BASE

PITRUN (6" MINUS OR OTHER

APPROVED ROADWAY SECTION)

NOT TO SCALE

ROAD SECTION DETAIL

2'-6"

T

O

P

S

O

I

L

C

U

T

S

L

O

P

E

2

:

1

2'-6"

NOT TO SCALE

PARKING LOT SECTION DETAIL

3" ASPHALT

(4")

3

4

" CRUSHED BASE

GRADING H OR W

12" SUB-BASE

PITRUN (6" MINUS OR OTHER

APPROVED ROADWAY SECTION)

2.0'

MIN.

1.5'

S

L

O

P

E

2

:1

M

A

X

2.0% MINIMUM

CMP (SIZE PER PLANS)

CMP (SIZE PER PLANS)

2.0'

MIN.

2.0'

MIN.

CLASS 1 RIPRAP SPLASH PAD

EDGE OF ROAD

ROAD

4"

4"

MINIMUM 12"

IF LESS THAN 12"

CONSULT ENGINEER

COMPACTED 1" MINUS PIPE BEDDING

COMPACT TO 95% MODIFIED PROCTOR

MAXIMUM 12" LIFTS

SIDE VIEW

PLAN VIEW

TRENCH CROSS SECTION

NOT TO SCALE

CULVERT DETAIL

PLAN

ELEVATION

STRAW BALE BARRIER

1. STRAW BALE LAYOUT MUST BE PRE-APPROVED BY THE ENGINEER.

NOTE

NOT MORE THAN 6"

EXPOSURE

BALES TO BE APPROX. 18"

SQUARE x 36" LG, STRAW TO

BE LAID W/ WIRE OR TWINE

NOT IN CONTACT WITH SOIL.

BALES MUST BE TIGHTLY

ABUTTED W/ NO GAPS

2" x 2" x 36" WOOD OR 36" #4

REBAR STAKES, 2 PER BALE

BALES TO BE TRENCHED

INTO NATIVE SOIL A

MINIMUM OF 3"

GROUND LINE

3" EMBEDMENT

BALES PLACED

ACROSS JOINTS IN

BOTTOM OF DITCH

STUFF WITH STRAW

TIE DOWN STAKES 3' MIN

BALES TO BE TRENCHED

INTO NATIVE SOIL A

MINIMUM OF 3"

NOT TO SCALE

STRAW BALE SEDIMENT FILTER DETAIL

FLOW

FLOW

VARIES

V

A

R

IA

B

L

E

V

A

R

IA

B

L

E

ROCK LINED INTERCEPTOR DITCH DETAIL

4" MIN. DEPTH OF 3"Ø OR

GREATER ROCK EXTENDING

HALFWAY UP DITCH SLOPE

1' DEPTH

NOTE:

WHERE DRAINAGE DITCH FALLS ALONG SLOPES LESS THAN 10%,

VEGETATED GRASS MAY BE USED.

NOT TO SCALE SLOPES > 10%

VARIES

VARIES

NATIVE SOIL

Plotted by P

Yantzi on F

eb 23, 2021 - 12:25pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.8-3.10 G

RA

DIN

G D

ET

AILS

.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.8

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

GR

AD

IN

G D

ET

AILS

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

Page 21: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

NOT TO SCALE

TWO WAY ACCESSIBLE SIDEWALK RAMP DETAIL

NOTE

1. SIDEWALK SLOPE PER PLAN: DO NOT EXCEED 5.0% LONGITUDINAL SLOPE

2. SIDEWALK CROSS SLOPE PER PLAN: DO NOT EXCEED 2.0% CROSS SLOPE

3. RAMP CROSS SLOPE: DO NOT EXCEED 2.0% CROSS SLOPE

4. RAMP SLOPE: DO NOT EXCEED 8.3% LONGITUDINAL SLOPE

5. LANDING SLOPE: DO NOT EXCEED 2.0% SLOPE IN EITHER DIRECTION

6"

3

5

4

COLORED DETECTABLE

WARNING PANEL

CURB PER PLAN

RAMP

SIDEWALK

PER PLAN

6"

SIDEWALK

WIDTH

PER PLAN

CURB PER PLAN

CURB PER PLAN

COLORED DETECTABLE

WARNING PANEL

SIDEWALK

PER PLAN

RAMP

LANDING FLUSH WITH ROADWAY

BOTTOM OF RAMP

FLUSH WITH ROADWAY

LANDING

5

5

4

3

1

2 3

41

2

RAMP

SIDEWALK

PER PLAN

LANDING

RAMP

SIDEWALK

PER PLAN

CURB PER PLAN

CURB TAPER

CURB TAPER

5

1

2

3

4

2

1

ISOMETRIC VIEW

PLAN VIEW

RAMP PARALLEL TO ROAD

NOTE

1. CURBS SHALL CONFORM TO SPECIFICATION 32 16 13, EXCEPT THAT PORTLAND CEMENT CONCRETE SHALL BE

FIBERMESH-REINFORCED CLASS 4000 CONCRETE CONFORMING WITH SPECIFICATION 32 13 13.

2. AGGREGATE BASE COURSE SHALL BE SIX INCH MINIMUM THICKNESS, CONFORM TO SPECIFICATION 31 05 16, PART 2.03,

GRADING H, AND BE INSTALLED PER SPECIFICATION 32 11 23, PART 3.03.

3. REMOVAL AND REPLACEMENT OF CURB SHALL TAKE PLACE IN FULL PANELS.

4. VERTICAL CURB SHALL BE USED IN PREFERENCE TO ROLL CURB.

5"

6"

6"

1"

12"

2" RADIUS

3

4

"

SLOPE

1

4

" PER FOOT

CURB CUT

6" MINIMUM AGGREGATE

BASE COURSE

24"

3"

6"

4"

1"

10"

3" RADIUS

3

4

"

SLOPE

1

4

" PER FOOT

6" MINIMUM AGGREGATE

BASE COURSE

24"

4" RADIUS

6"

3

4

"

SLOPE

1

4

" PER FOOT

6" MINIMUM AGGREGATE

BASE COURSE

12"

7

1

2

"

3

4

"

24"

1"

6" MINIMUM AGGREGATE

BASE COURSE

ROLL CURB

RIBBON CURB

VERTICAL CURB

2' WIDE VALLEY GUTTER

NOT TO SCALE

CURB SECTION DETAIL

NOT TO SCALE

ACCESSIBLE SIDEWALK RAMP DETAIL

NOTE

1. SIDEWALK SLOPE PER PLAN: DO NOT EXCEED 5.0% LONGITUDINAL SLOPE

2. SIDEWALK CROSS SLOPE PER PLAN: DO NOT EXCEED 2.0% CROSS SLOPE

3. RAMP CROSS SLOPE: DO NOT EXCEED 2.0% CROSS SLOPE

4. RAMP SLOPE: DO NOT EXCEED 8.3% LONGITUDINAL SLOPE

5. LANDING SLOPE: DO NOT EXCEED 2.0% SLOPE IN EITHER DIRECTION

2

COLORED DETECTABLE

WARNING PANEL

FULL WIDTH OF LANDING

1

4

5

3

2

3

5

4

1

2

1

4

3

5

5

3

4

1

2

SIDEWALK WIDTH

PER PLAN

LEVEL LANDING

5.0' (MINIMUM)

SIDEWALK RADIUS PER PLAN

CURB RADIUS PER PLAN

REQUIRED

LANDING

CURB HEIGHT

6" MAXIMUM

RAMP FLARE

LANDING FLUSH WITH ASPHALTCOLORED DETECTABLE

WARNING PANEL

FULL WIDTH OF LANDING

ISOMETRIC VIEW

PLAN VIEW

RAMP ON CORNER

PLAN

SECTION A

SECTION B

NOT TO SCALE

CURB INLET DETAIL

30" PRECAST CATCH BASIN

GUTTER FLOWLINE

CURB INLET

CURB CAST IN FIELD OVER INLET

TOP OF CURB

CATCH BASIN HEAD OLDCASTLE PRECAST

OR APPROVED EQUAL30" CATCH BASIN WITH FLOOR

GRADE RINGS AS NEEDED

4'

3' 3'1' 1'

6"

BACK OF CURB

TYPICAL CURB

AND GUTTER

WIDENED CONCRETE CURB

CURB INLET, FRAME AND GRATE

STREET

PAVEMENT

B

AA

B

WIDENED CONCRETE CURB

FINISHED GRADE ABOVE CURB

3-FLANGE GUTTER INLET FRAME

NEENAH FOUNDRY R-3589 OR APPROVED EQUAL

(2)

1

2

X8 HEADED STUD WELDED TO BOTTOM OF FRAME

WIDENED GUTTER SECTION

STREET PAVEMENT

L3x2

1

2

x

1

4

" ANGLE WITH

3)

1

2

x8 HEADED STUD ANCHOR

WELDED TO INSIDE OF ANGLE

TYPE L GUTTER INLET GRATE

NEENAH FOUNDRY R-3589 OR APPROVED EQUAL

CATCH BASIN HEAD OLDCASTLE PRECAST

OR APPROVED EQUAL30" CATCH BASIN WITH FLOOR

GRADE RINGS AS NEEDED

15" NO. 4 REBAR WITH 90° BEND

EPOXY 3" INTO CATCH BASIN HEAD

21" NO. 4 REBAR TIED TO HOOKED REBAR

ISOLATE FRAME WITH EXPANSION JOINT

NOT TO SCALE 30" PRECAST CATCH BASIN

AREA DRAIN DETAIL

GRADE RINGS AS REQUIRED

TO MATCH FINISHED GRADE

12" MAXIMUM

OLDCASTLE 30" CATCH BASIN

OR APPROVED EQUAL

STORM WATER INLET PIPE

2' MINIMUM

SUMP

4" MINIMUM COMPACTED GRAVEL

STORM WATER OUTLET PIPE 90° BEND FITTING ON OUTLET PIPE

CONCRETE GROUND SEAL

FOR ALL PIPE PENETRATIONS

6" MINIMUM

NOTE

1. GRAVEL SHALL BE 4" MINIMUM THICKNESS, CONFORM TO WPWSS SECTION 02190, PART2.03, GRADING H. AND BE INSTALLED

PER WPWSS SECTION 02231, PART 3.03

2. ALL DIMENSIONS TO BE APPROVED BY THE ENGINEER.

3. MANHOLE COVER SHALL BE DESIGNED FOR H20S LOADING.

4. SEE DETAIL FOR CURB INLET.

FINISHED GRADE PER PLAN

ROUNDED CONCRETE COLLAR

FRAME AND GRATE

D&L A-1055 FRAME WITH

C-1055 INLET GRATE

VARIES

V

A

R

IA

B

L

E

V

A

R

IA

B

L

E

DETENTION BASIN

COBBLE STONE

DRAINAGE

BASIN

2' SWALE

NOTE

STONEY ALLUVIUM FOR INFILTRATION EXISTS 3 FEET BELOW

EXISTING GRADE. EXCAVATE INTO STONEY MATERIAL PER SITE

PLAN.

NOT TO SCALE

VARIES

VARIES

NATIVE SOIL

Plotted by P

Yantzi on F

eb 23, 2021 - 12:25pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.8-3.10 G

RA

DIN

G D

ET

AILS

.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.9

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

GR

AD

IN

G D

ET

AILS

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

Page 22: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

RE

TA

IN

ED

H

EIG

HT

EM

BE

DM

EN

T D

EP

TH

6x6 PRESSURE TREATED TIMBER

LAGGING WITH PRESSURE

TREATED 2x6 BLOCKING BETWEEN

COURSES TO ALLOW FOR

DRAINAGE THROUGH WALL FACE.

INSTALL NON-WOVEN

GEOTEXTILE AT BACK OF

TIMBER LAGGING TO

RETAIN SOIL AT BLOCKING.

WELD STEEL TAB AT

BOTTOM OF TIMBER

LAGGING TO PREVENT

SETTLEMENT OF TIMBERS.

3

1

DRIVEN H-PILE, ASTM

A572 Gr. 50, REFER TO

TABLE FOR SECTION

CALL-OUT AND SPACING

CUT TIMBER LAGGING

TO FOLLOW UPHILL

FINISH GRADE

INSTALL CAP TIMBER OVER

CUT ENDS OF LAGGING

FIELD TREAT CUT ENDS

OF LAGGING WITH

COPPER NAPHTHENATE

INSTALL TWO LAG SCREWS

PER LAGGING TIMBER WHEN

CUT FACE IS LONGER THAN 15"

3

4

"Øx16" LAG SCREWS

INTO EACH TIMBER

LAGGING BOARD TO

SECURE CUT END

TIMBER LAGGING

TO BE INSTALLED

LEVEL

INSTALL 2x PRESSURE TREATED

BLOCKING 18" LONG AT EACH

LAGGING COURSE TO PROVIDE

DRAINAGE PATH FOR WATER

BEHIND WALL FACE. SECURE

BLOCKING TO LAGGING WITH 3

ROWS OF (3) 12d NAILS

DRIVEN PILE SPACING DRIVEN PILE SPACING

DRIVEN PILE/TIMBER LAGGING RETAINING WALL

RETAINED HEIGHT PILE SIZE PILE SPACING EMBEDMENT DEPTH NOTES

0'-0" TO 4'-0" HP10x42 8'-0" 20'-0" MINIMUM DO NOT SPLICE PILES

4'-0" TO 8'-0"HP12x63 6'-0" 32'-0" MINIMUM

DO NOT SPLICE PILES

8'-0" TO 11'-0"HP12x74 4'-0" 29'-0" MINIMUM

DO NOT SPLICE PILES

MAXIMUM SLOPE

BEHIND WALL

SCALE: 1/2" = 1'-0"

PILE AND TIMBER RETAINING WALL DETAILS

3" M

IN

.

CO

VE

R

2" M

IN

.

CO

VE

R

1'-0

"2

'-0

" M

IN

IM

UM

4'-0

" M

AX

IM

UM

RE

TA

IN

ED

H

EIG

HT

6" M

IN

.

8"

2" MIN.

COVER

3:1 MAXIMUM SLOPE

BEHIND WALL

1'-6"

6'-0"

#5 REBAR @ 16"o.c. FOR

TOP AND BOTTOM MATS

#5 REBAR @ 12"o.c.

#5 REBAR @ 12"o.c., BEND

BARS AND EXTEND INTO

WALL REINFORCING

#5 REBAR @ 16"o.c.

#5 REBAR @ 12"o.c.

6'-0

" M

AX

IM

UM

W

AL

L H

EIG

HT

SCALE: 1/2" = 1'-0" FOR WALLS UP TO 4FT EXPOSED

RETAINING WALL DETAIL

2" PVC WEEP HOLE

AT 8' ON CENTER

TIED TO PERFOATED

DRAIN BEHIND WALL

FOR DRAINAGE

10"

3:1 MAXIMUM SLOPE

BEHIND WALL

3" M

IN

.

CO

VE

R

2" M

IN

.

CO

VE

R

1'-2"

2'-0" M

IN

.

8'-0" M

AX

IM

UM

RE

TA

IN

ED

H

EIG

HT

2'-0"

2'-0"

#6 REBAR @ 16"o.c. FOR

TOP AND BOTTOM MATS

#6 REBAR @ 12"o.c.

#6 REBAR @ 8"o.c.,

BEND BARS AND

EXTEND INTO WALL

REINFORCING

10'-0" M

AX

IM

UM

W

ALL H

EIG

HT

1'-0" 4'-0"

7'-0"

4'-0" T

O C

HA

NG

E

IN

B

AR

S

PA

CIN

G

#6 REBAR @ 8"o.c.

#5 REBAR @ 16"o.c. TIED TO #6

BARS WITH 2'-0" LAP DISTANCE

#5 REBAR @ 16"o.c.

1'-4"

#6 REBAR @ 12"o.c.

EACH DIRECTION

1'-0"

3:1 MAXIMUM SLOPE

BEHIND WALL

3" M

IN

.

CO

VE

R

2" M

IN

.

CO

VE

R

1'-2"

2'-0" M

IN

.

12'-0" M

AX

IM

UM

RE

TA

IN

ED

H

EIG

HT

3'-3"

3'-3"

#6 REBAR @ 16"o.c. FOR

TOP AND BOTTOM MATS

#7 REBAR @ 10"o.c.

#7 REBAR @ 4"o.c.,

BEND BARS AND

EXTEND INTO WALL

REINFORCING

14'-0" M

AX

IM

UM

W

ALL H

EIG

HT

1'-0" 6'-3"

10'-6"

4'-0" T

O C

HA

NG

E

IN

B

AR

S

PA

CIN

G

#7 REBAR @ 4"o.c.

#7 REBAR @ 12"o.c. TIED TO #7

BARS WITH 3'-6" LAP DISTANCE

#5 REBAR @ 12"o.c.

3'-0"

#6 REBAR @ 6"o.c.

#6 REBAR @ 12"o.c.

2" MIN.

COVER

2" MIN.

COVER

6" M

IN

.

6" M

IN

.

SCALE: 3/8" = 1'-0" FOR WALLS UP TO 8FT EXPOSED

RETAINING WALL DETAIL

SCALE: 3/8" = 1'-0" FOR WALLS UP TO 12FT EXPOSED

RETAINING WALL DETAIL

2" PVC WEEP HOLE

AT 8' ON CENTER

TIED TO PERFOATED

DRAIN BEHIND WALL

FOR DRAINAGE

2" PVC WEEP HOLE

AT 8' ON CENTER

TIED TO PERFOATED

DRAIN BEHIND WALL

FOR DRAINAGE

20°

EQ

.E

Q.

4

1

10

'-0

" M

AX

H

EIG

HT

4'-0"

20°

4'-0" AVERAGE DIAMETER

STACKED BOULDERS

SCALE:

1

2

"=1'-0"

BOULDER RETAINING WALL

MAX SLOPE

FOR 10'-0"

LEVEL GRADE BELOW

WALL FOR 4'-0" BEFORE

SLOPING DOWN

4" Ø PERFORATED

DRAIN TILE

- DRAIN TO

DAYLIGHT

12" MIN.

3

8

" - 1

1

2

" WASHED

GRAVEL DRAINAGE

LAYER

-ENCAPSULATE IN

MIRAFI 180N OR

APPROVED EQUAL

DISTURBED

EARTH

UNDISTURBED

EARTH

3

8

" - 1

1

2

" WASHED GRAVEL

DRAINAGE LAYER

-ENCAPSULATE IN MIRAFI

180N OR APPROVED EQUAL

24" MIN.

36" - 48" MIN.

4' MAXIMUM

COIR FABRIC INSTALLED PER

MANUFACTURER'S

INSTRUCTIONS. ANCHOR

BEHIND ROCKERY

12" MIN.

EMBEDMENT

NOT TO SCALE

BOULDER SITE WALL - MAX HEIGHT 4'

Plotted by P

Yantzi on F

eb 23, 2021 - 12:25pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.8-3.10 G

RA

DIN

G D

ET

AILS

.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.10

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

GR

AD

IN

G D

ET

AILS

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021

NOTE:

AVALANCHE WALL DESIGN PENDING

COORDINATION WITH WILBUR ENGINEERING, INC.

REGARDING SPECIFIC DESIGN LOADS.

1

1

Page 23: GEC Permit Application · GEC Permit Application 3 Effective 01/12/2021 1. O ne stof compl e GEC d ra w i g caled on 11”x17” paper. 2. One X PDF set of scaled drawings and GEC

E

X

I

S

T

I

N

G

R

O

A

D

O

R

S

I

D

E

W

A

L

K

D

R

I

V

E

W

A

Y

A

P

P

R

O

A

C

H

25' RADIUS MINIMUM

PROVIDE FULL WIDTH OF

INGRESS/EGRESS AREA

10' MINIMUM

AS REQUIRED

50' MINIMUM MAY BE REDUCED

FOR SITES WITH LESS THAN

ONE ACRE OF EXPOSED SOIL

6" MINIMUM

GEOTEXTILE

SEE NOTE 1

EXISTING ROADWAY

EXISTING SIDEWALK

DRIVEWAY APPROACH

(WHERE OCCURS)

5.0' MINIMUM

CRUSHED ROCK

3" NOMINAL SIZE

OR APPROVED EQUAL

GEOTEXTILE

SEE NOTE 1

NOTE

1. PLACE CONSTRUCTION GEOTEXTILE FOR SOIL STABILIZATION UNDER THE CRUSHED ROCK FROM THE EDGE OF THE

EXISTING ROADWAY OR SIDEWALK TO THE RADIUS RETURNS.

2. ENTRANCE SHALL BE REMOVED AND RECONSTRUCTED AS REQUIRED TO PREVENT EXCESS TRACKING OF

MATERIALS INTO RIGHT-OF-WAY.

CONSTRUCTION ENTRANCE SECTION

CONSTRUCTION ENTRANCE ISOMETRIC VIEW

NOT TO SCALE

STABILIZED CONSTRUCTION ENTRANCE DETAIL

Plotted by P

Yantzi on F

eb 23, 2021 - 12:25pm

PROJECT NUMBER

SHEET

H:\2015\15040 - S

RS

C\24 - R

esort Z

one P

hase 3 &

4\C

AD

\C

ON

ST

RU

CT

IO

N\15040.24_C

3.8-3.10 G

RA

DIN

G D

ET

AILS

.dw

g

SH

EE

T T

IT

LE

:P

RO

JE

CT

T

IT

LE

:

DATE

www.jorgeng.com

REVIEWED BY:

DRAFTED BY:

PLAN VERSION

Ve

r. 1

8.0

JACKSON, WYOMING

307.733.5150

15040.24

C3.11

SN

AK

E R

IV

ER

S

PO

RT

IN

G C

LU

B

PH

AS

ES

3 A

ND

4 O

F A

RE

A III

PH

AS

E 3 C

ON

ST

RU

CT

IO

N D

OC

UM

EN

TS

TE

TO

N C

OU

NT

Y, W

YO

MN

G

GR

AD

IN

G D

ET

AILS

PY

BB

GEC PERMIT 01/20/2020

GEC PERMIT REV1 02/18/2021