Eolo | Olympia

FIRE System

Addresed digital panelsCertification EN 54

Management over TCP / IP

Page 2: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

2 | FIRE System

Page 3: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 3

Addressed digital panels .........................................................................4

Peripherals for addressed digital units .............................................6

Addressed detectors .................................................................................7

Addressed modules ....................................................................................9

Addressed call points and sounder .................................................. 10

Conventional detectors modules ...................................................... 11

Accessories for addressed detectors .............................................. 11

Wireless fire detection modules ........................................................ 12 Integrated monitoring software ........................................................ 13

Conventional detectors ......................................................................... 14

Alarm call point ......................................................................................... 15

Acoustic optical display units ............................................................. 16

Reflective optical beam linear smoke detectors ........................ 17

Linear smoke detector barriers .......................................................... 18

Anti flodding .............................................................................................. 18

Gas detector ............................................................................................... 19

Flame detectors ........................................................................................ 20

Spark detector ........................................................................................... 20

Sirens and bells ......................................................................................... 21

Electromagnetic block............................................................................ 21

Adaptors and power supply units ..................................................... 22

Open frame adaptors.............................................................................. 23

Cables ............................................................................................................ 23

Batteries ...................................................................................................... 23

INDEX

Page 4: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

4 | FIRE System

Ad

dre

sse

d d

igit

al

pa

ne

ls

> EOLO2 loop addressed digital panel

Hardware Features

• 16bitmicroprocessoranalogunit• 2digitalprotocoladdressedanalogloopswithopen orclosedconfiguration• 240detectors/modulesperloop.• 40x2characterLCDdisplaywithback-lightfunction• Touchkeypadwith25functionkeys• 2openorclosedloops• Loopshortcircuitprotection.• 17frontpanelLEDS• 1supervisedsounderoutput(24Vdc1A)• 1supervisedoutputtotriggerthefirealarmsignaldevices ortheactivationoftheextinguisherdevices• 1faultrelayoutputwithfloatingcontacts-1A30Vdc120Vac• 1excludedsensors/modules/areasrelayoutputwithfloating contacts-1A30Vdc120Vac• 1technologicalrelayoutputwithfloatingcontacts-1A 30Vdc120Vac• 1RS485seriallineforconnectiontoremotepanelsandprinter• 1RS232Cseriallineforcentralization,remotemanagement andremoteprogrammingwithCEI79/5,79/6protocol)• 1alarmrelayoutputwithfloatingcontractoutput• ProgrammingdatastoredonnonvolatileEEPROMmemories n.217aHcapacityaccumulatorswithtemperaturecontrolled batterycharger•Warningsignalsfor: -230Vacpowersupplyabsence -Batteryabsence -Lowbattery -Faultybatterycharger• Auxiliarypoweroutput24Vdc2.5monitoredandprotected againstshortcircuitsforexternalloads•Managementofadditionalconventionalline viaFDVMCZ100module• Powerconsumptionwhenidle300mAat12Vdc(430mA onprimary230Vac)• Dimensions:450x410x130mm• Powersupply:230Vac/27Vdc5.6A

Functional characteristics

• Divisioninupto32detectionareas• 32logicfunctions• Historicallyarchiveofthelast385events• Automaticloopdevicesdiscovery•Managementofvarioustypesofdetectorsandanalogmodules: -Optical,Thermalandmixeddetectors -Inputmodules -Outputmodules -Addressedbuttons -Addressedanalogsounders• Customisedprogrammingofphrasesforeachinput• 1programmingpassword• 1Maintenancepassword• Technologicalfunctionality• LocalorremoteprogrammingusinglocalWinSW viaseriallineorLAN/WANnetwork•Managementofgasdetection

reference StandardsProductcertifiedtoEN54-2andEN54-4CertifiedN°1293-CPD-0154standardsCEMarking(EMClowvoltagedirective)

Page 5: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

alarm devicefault

pre-alarm test

excludedinputs

silence

faultsystemfault

groundfault

sounderfault

Area 1

Area 9

Area 17

Area 25

Area 2

Area 10

Area 18

Area 26

Area 3

Area 11

Area 19

Area 27

Area 4

Area 12

Area 20

Area 28

Area 5

Area 13

Area 21

Area 29

Area 6

Area 14

Area 22

Area 30

Area 7

Area 15

Area 23

Area 31

Area 8

Area 16

Area 24

Area 32

ENTER

FIRE System

FIRE System | 5

Ad

dre

sse

d d

igit

al

pa

ne

ls

> OLYMPIA4 loop addressed digital panel expandable up to 16 loops

Hardware Features

• 16bitmicroprocessoranalogunit• 4digitalprotocoladdressedanalogloops, expandableupto16usingOLY4expansioncards• 240detectors/modulesperloop.• 40x8characterLCDdisplaywithback-lightfunction• Touchkeypadwith25functionkeys• 4openorclosedloopsexpandableupto16loopsusingOLY4 expansioncards• Loopshortcircuitprotection.• 12frontpanelLEDsand32frontpanelareastatusLEDS• 1supervisedsounderoutput(24Vdc1A)• 1supervisedoutputtotriggerthefirealarmsignaldevices ortheactivationofthetheextinguisherdevices• 1faultrelayoutputwithfloatingcontacts-1A30Vdc120Vac• 1excludedsensors/modules/areasrelayoutputwithfloating contacts-1A30Vdc120Vac• 1technologicalrelayoutputwithfloatingcontacts -1A30Vdc120Vac• 1alarmrelayoutputwithfloatingcontractoutput• 1RS485seriallineforconnectiontoremotepanelsandprinter• 1RS232Cseriallineforcentralization,remotemanagement andremoteprogrammingwithCEI79/5,79/6protocol)• ProgrammingdatastoredonnonvolatileEEPROMmemories 226aHcapacityaccumulatorswithtemperaturecontrolled batterycharger•Warningsignalsfor: -230Vacpowersupplyabsence -batteryabsence -Lowbatteryandexhausted -Faultybatterycharger• Auxiliarypoweroutput24Vdc2.5Amonitoredandprotected againstshortcircuitsforexternalloads•Managementofadditionalconventionalline viaFDVMCZ100module• Powerconsumptionwhenidle600mAat12Vdc• Dimensions:525x460x145mm(AxLxP)• Powersupply:230Vac/27Vdc5.6A• 1supervisedoutputtofirealarmsystemofcomunication

Functional characteristics

• Divisioninupto96detectionareas• 96logicfunctions• Historicallyarchiveofthelast1024events• Automaticloopdevicesdiscovery•Managementofvarioustypesofdetectorsandanalogmodules: -Optical,Thermalandmixeddetectors -Inputmodules -Outputmodules -Addressedbuttons -Addressedanalogsounders• Customisedprogrammingofphrasesforeachinput• 1programmingpassword• 1Maintenancepassword• Technologicalfunctionality• LocalorremoteprogrammingusinglocalWinSW viaseriallineorLAN/WANnetwork•Managementofgasdetectioncertified

reference Standards:

ProductcertifiedtoEN54-2andEN54-4standardsCEMarking(EMClowvoltagedirective)

Page 6: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

6 | FIRE System

> TKE Remote control panel for EOLO and OLYMPIA fire control panel

• 40x2characterLCDdisplaywithback-lightfunction• 17statusLEDs• 19functionbuttons:Silence,Reset,Silence/rearmsounderalarm,Status,ArrowUp, Down,LeftandRightbuttons,ENTERkey,Numericalkeysfrom0to9• Forremotemanagement(max4keyboards)forEoloandOlympiaunits• Canbeconnectedtoalladdressableanalogunits•Mechanicalkeyforuseonthekeyboard•Metalcase•Wallordeskversionavailable• Dimensions:230x120x45• Powersupply:24Vdc

> OLY 4 4 addressed analog loop expansion card for Olympia unit

• Fittedinsidethecontrolpanel.• 1genericrelayalarmoutput1A30Vdc120Vac• 1faultrelayoutput1A30Vdc120Vac• 1excludedsensors/modules/areasrelayoutput1A30Vdc120Vac• Configurationof4loopsClosedorOpen• Themaximumcapacityforeachloopis240detectors/modules, foratotalof3,840devicesfora16loopconfiguration.Theseapplicationsaretoassembled toEN-54Standards,howeveritisnecessarytokeepinmindthemandatorylimitof512devices perOLY4(4loop)card,foratotalof2,084devices.

Pe

rip

he

rals

fo

r a

dd

ress

ed

dig

ita

l u

nit

s

> PR40 40 column thermal printer for fire detection units

• ConnectiononRS485serialline•Out-of-papermonitoring•Metalcaseforwall-mounting• Powersupply12Vdc

> PTLAN Ethernet interface for analog fire detection unit

• TTLserialinterfacepoweredbythepanelandhousedinternally• From300to230kbps• Controlsignals:RTS,CTS,DTR,DCD• Ethernetinterface10BaseT• RJ45Connector•Operatingtemperature:-10C°+50C°• Dimensions:45x90x28m

> WIN LOCAL Programming sw for EOLO and OLYMPIA fire detection panels

WindowsenvironmentSWtoprogramtheFireDetectionpanelsandallotherTELEDATAdevicesonRS232seriallinesorLANandWANgeographicalnetworks

Page 7: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 7

Ad

dre

sse

d d

ete

cto

rs

> SF2000 Optical + Thermal Rate of Rise detector addressed with digital communication protocol

• Combinedopticalsmoke+rateofrisedetectorat58°C• Itismadefrommulti-colouredplasticmaterial andhasamoderndesign.• Fittedwithintegratedinsulationcircuit• Automaticself-adaptationtothevariationsinenvironmental conditions• 3colorLED

• Power10-40V•Averagepowerconsumption90µA•MaximumpowerconsumptionofremoteLED6mA•Operatingtemperature:-30C°to+70C°•Maxhumidity:95%withnocondensation• Height:54mm•Diameter:110mm•Weightwiththebase:130g

> SF3500 Programmable Thermal fixed and Rate of Rise detector addressed with digital communication protocol

• Itoperatesinthermalfixedmodewithatemperature thresholdof78°C• Itismadefrommulti-colouredplasticmaterial andhasamoderndesign.• Fittedwithintegratedinsulationcircuit• 3colorLED•Programmableoperatigtemperature58°Cor78°C

• Power:10-40V•Averagepower:consumption90µA•Maximumpower:consumptionofremoteLED6mA•Operatingtemperature:-30C°to+70C°•Maxhumidity:95%withnocondensation• Height:54mm•Diameter:110mm•Weightwiththebase:130g

> SF1000 Optical smoke detector addressed with digital communication protocol

> SF1000 E Optical smoke detector addressed with digital communication protocol

> SF2000 E Optical + Thermal Rate of Rise detector addressed with digital communication protocol

> SF3500 E Programmable Thermal fixed and Rate of Rise detector addressed with digital communication protocol

• LowprofileopticalsmokedetectortobefittedontheBS100base• Itismadefrommulti-colouredplasticmaterial andhasamoderndesign.• Fittedwithintegratedinsulationcircuit.• Automaticself-adaptationtothevariationsinenvironmental conditions• 3colorLED

• Powersupply10-40V• Averagepowerconsumption90µA•MaximumpowerconsumptionofremoteLED6mA•Operatingtemperature-30C°to+70C°• Maxhumidity95%withnocondensation• Height:54mm• Diameter:110mm•Weightwiththebase:130g

SamefeaturesofSF1000butwithoutisolatoronboardandwithasinglecolorLED

SamefeaturesofSF2000butwithoutisolatoronboardandwithasinglecolorLED

SamefeaturesofSF3500butwithoutisolatoronboardandwithasinglecolorLED

Page 8: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

8 | FIRE System

> BS100 Standard base

> SF XXX0 COLOR XX Detectors customized with different colours

Colouredsmokedetectorsarealsoavailablecustomizedtoclientspecifications.Thesesolutionsarespecificallydesignedforinstallationprojectswherethefinaloveralllookisveryimportant

CARRARA11

MarBLe

BLACK15 CILIEGIO23

wOOd

ORO31

MeTaL

ALLUMINIO32

• Itismadefromplasticmaterialandhasamoderndesign.• FittedwithresistorforFD104unit• VersionwithrelaybaseonboardBSE100Rmodelalsoavailable• Diameter:110mm•Height:42mm•Weight(without)thebase:99.4g•Operatingtemperature:-10÷+60°C• Relativeoperatinghumidity10÷ 93%noncondensing• Localwarningindicator(standbyandalarm)-RedLED•ABS+PC(UL94-V0)plasticmaterials

Page 9: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 9

Addressed wall modules interfaceable with unit loop devices

Addressed mini modules interfaceable with unit loop devices

> FDVMI100 Input mini module> FDVMC120 Output mini module > FDVMC100 Monitored output mini module> FDVMM120 Input and output mini module> FDVMM100 Monitored input and output mini module

• Power10-40V•Averagepowerconsumption120µA• PowerconsumptionofLED6mA(24V–line)• Fittedwithintegratedinsulationcircuit• Relayoutput30Vdc2A•Operatingtemperature–30°Cto70°C•Maxhumidity95%withnocondensation• Dimensions87x87x23mmwithoutbracket•Weight:200g

Ad

dre

sse

d m

od

ule

s

> FDVMIC404 4 input 4 output moduleSamefeaturesofFDVMIC100butwithdimensions130x130x35

> FDVMIC422 4 input 2 output 2 monitored output moduleSamefeaturesofFDVMIC100butwithdimensions130x130x35

> FDVMIC602 6 input 2 output moduleSamefeaturesofFDVMIC100butwithdimensions130x130x35

> FDVMIC100 Monitored input and output module

• Power10-40V•Averagepowerconsumption120µA• PowerconsumptionofLED6mA(24V–line)• Fittedwithintegratedinsulationcircuit• Relayoutput30Vdc2A•Operatingtemperature:–30°Cto70°C•Maxhumidity:95%withnocondensation• Dimensions:87x87x23mmwithoutbracket•Weight:200g

*on request

Page 10: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

10 | FIRE System

Addressed DIN rail mount modules interfaceable with unit loop devices

> FDVMDI100 Input mini module > FDVMDC100 Monitored output mini module> FDVMDC120 Output mini module> FDVMDIC100 Monitored input and output mini module> FDVMDIC120 Input and output mini module

• Power:10-40V•Averagepowerconsumption120µA• PowerconsumptionofLEDs6mA(24V–line)• Fittedwithintegratedinsulationcircuit• Relayoutput:30Vdc2A•Operatingtemperature:–30°Cto70°C•Maxhumidity:95%withnocondensation

Ad

dre

sse

d c

all

po

ints

an

d s

ou

nd

er > FDVCP100 Fire alarm call point addressed ripristinable

• RedcolouredABS• Fittedwithintegratedinsulationcircuit• Accessoriesforflash-mountingfixture• Power:10-40V•Averagepowerconsumption70μA• PowerconsumptionofLED6mA(24V–line)•Operatingtemperature:-20C°+65C°•Maxhumidity:95%withnocondensation• Dimensions:87x87x23mm

> FDS100 Electronic sounder addressed

• 3tone• Programmablesounderviaprotocol• Redplasticcasing• Fittedwithintegratedinsulationcircuit• Power:15-30V•Averagepowerconsumption70μA• Powerconsumptionofenabledsiren5mA(24V–line)• Sirenoutput100dB•Activationtimeonstartup2sec• ProtectionratingIP42•Operatingtemperature:–25°Cto70°C•Maxhumidity:95%withnocondensation• Dimensions:87x87x23mmwithoutbracket•Weight:200g

• 3tone• programmableviaprotocol• Redplasticcasing• Fittedwithintegratedinsulationcircuit• Power15-30V•Averagepowerconsumption70μA• Powerconsumptionofenabledsiren9mA(24V–line)• Sirenoutput100dB• Flashingindicatorbrightnesslevel2cd• Activationtimeonstartup2sec• ProtectionratingIP21•Operatingtemperature–10C°+55°C•Maxhumidity95%withnocondensation• Dimensions87x87x23mmwithoutbracket•Weight:200g

> FDS100LMPG Electronic sounder and flashing indicator addressed

*on request

*on request

*on request

*on request

*on request

Page 11: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 11

> FDVMC Z100 Addressed modules for conventional detectors

• Fittedwithintegratedinsulationcircuit• Absorption:500μAinStand-Bymode• Powersupply:14-40V•Averagepowerconsumption:120μA•Operatingtemperature:-30°C+70°C•Minimumvoltage=18V

Co

nv

en

tio

na

l d

ete

cto

rs m

od

ule

s

> BOX500 Box for detectors for installation in shafts

• Adaptorforinstallationoutsideairshafts• DetectoralarmLEDvisiblethroughthetransparentsurface• Dimensions:220x165x100mm

Acc

ess

ori

es

for

ad

dre

sse

d d

ete

cto

rs

> FDB100 Universal sounder for optical smoke detector

• Addressedanaloguedetectorsoundertobeassembledonthedetector• TriggeredwhenthedetectoralarmrepeaterLEDcomeson• Acousticpressureat1meter94dBa• Consumptionat24Vdc11mA• ProtectionratingIP42• 4differenttones•Operatingtemperature-20C°+70C°•Weight:121g

> FDP100 Programmer for Analog module and detector addressed with digital communication protocol

• Display2x8• Displaycontrolkeypad• Addressprogramming/deletefunction• Thresholdprogrammingfunctionoftemperatureforthermalsensors• Detectorstatusfunction• Batteryincluded9V

> FDVCP100 Fire alarm call point addressed ripristinable

*on request

Page 12: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

12 | FIRE System

Wir

ele

ss f

ire

de

tect

ion

mo

du

les

> FDW2W Wirelless reciver and protocol conveter Teledata•Wirelessmoduleanddetectorreceivedforamaximumof32elements• Poweredbythepanelloop,andabletoaddressthedifferentelementsindividually• Bi-directionalwirelesscommunicationwithdevices• Upto600squaremtcoveragearea• Canbeprogrammedtoquerythedevicesfromevery12sectoevery2min.• PCprogrammabledevice• Suppliedwithdualbatterywithlowbatteryindicator•Wirelessradiofrequency868-870MHz• RadiatedPowerfrom0.01to7mW•Modulationtype:FM•Wirelessqueryintervalfrom12secto12min.• Numberofchannels:7• Primarybattery:CR123A• Secondarybattery:CR2032A•Operatingtemperature:-10C°+55C°• Powersupplybyloop

> SWF1000 Optical smoke detector with wireless communication protocol

> SWF2000 Optical + thermal detector with wireless communication protocol

> SWF3500 Thermal sensor with wireless communication protocol

• Bi-directionalcommunicationprotocol• Suppliedwithdualbatterywithlowbatteryindicator• Primarybattery:CR123A• Secondarybattery:CR2032A• Itismadefrommulti-colouredplasticmaterialandhasamoderndesign.• Automaticself-adaptationtothevariationsinenvironmentalconditions• Tamperprotection• ComplianttoEN54-5EN54-7EN54-25Standards

> FDWVMI100 Input mini module with wirelesscommunication protocol

• Fittedwith2two-colourLEDS• Suppliedwithdualbatterywithlowbatteryindicator• Primarybattery:CR123A• Secondarybattery:CR2032A• Tamperprotection•Operatingtemperature:–30C°+70°C•Maxhumidity:95%withnocondensation• Dimensions:87x87x23mmwithoutbracket•Weight:200g

> FDWVMI120 Form C output mini module with wireless communication protocol

> FDWCP100 Fire alarm call point with wireless communication protocol• AlarmcallpointmadefromredcolouredABS• Suppliedwithdualbatterywithlowbatteryindicator• Primarybattery:CR123A• Secondarybattery:CR2032A• Tamperprotection•Operatingtemperature:-20C°+65C°• Dimensions:87x87x23mm

> FDSGLSP100 Electronic sounder with radio communication protocol• 3tonesounderinredplasticcasing• Suppliedwithdualbatterywithlowbatteryindicator• Primarybattery:CR123A• Secondarybattery:CR2032A• Fittedwithintegratedinsulationcircuit• Sirenoutput100dB•Activationtimeonstartup2sec• ProtectionratingIP42•Operatingtemperature:–25°Cto70°C•Maxhumidity:95%withnocondensation• Dimensions:87x87x23mmwithoutbracket•Weight:200g

Page 13: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 13

• Integratedmonitoringsystemtocontroldevices: -FireDetection -CCTV -Burglaralarm -Accesscontrol -BASBuildingautomationsystem• LANandWANlinemanagement• Telephonelines:PSTNGSMISDN•Dedicatedline:RS232RS485pointtopointMultiprotocolmanagement•Multimonitormangementoneachworkstationwithgraphicmapsanduserfriendlyinterface• Clientserversystemarchitecture• Completecontrolofeverysingledeviceincludingremoteprogrammingandremotefirmwareupdating• Hierarchicalsystemscalablebyusercategory• Advancedeventstorageandsearchfunctions• Customizabletosuitallcustomerrequirements•Operatingenvironment:Windows

Winwatch versions available

> Win Terminal max 2 devices

> Win Super max 6 devices

> Win Max max 12 devices

> Winwach Enterpise Management of an unlimited number of peripherals

Optional modules for integration

> Win client Management module for 1 additional client work station

> Win Mappe Interactive image-maps management module

> Win back up Module for back up management of the devices

connected to GSM data lines

Inte

gra

ted

mo

nit

ori

ng

so

ftw

are

Multi-function monitoring software

> C32/85 RS232 - RS 485 serial converter

• TheconverteristobeconnectedtothePConwhichtheWINWATCHenvironment monitoringsoftwareisinstalled• ConvertstheRS232serialoutputtoRS485orRS422• Providesfortheconnectionofseveralmultidropunitswithgalvanicisolation• Powersupply:12Vdc

Page 14: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

14 | FIRE System

> SF100 Optical smoke conventional detector> SF200 Optical + thermal smoke conventional detector> SF400 Thermal smoke conventional detector

• LowprofileforinstallationonthestandardanalogbaseBSE100• Itismadefromplasticmaterialandhasamoderndesign• Diameter100mm•Height42mm•Weight(without)thebase99.4g•Operatingtemperature(-30÷+70)°C• Relativeoperatinghumidity(95%)noncondensing• RemotecontrolLED6mA•ABS+PC(UL94-V0)plasticmaterials• Parts5and7certifiedtoEN54Standard• Consumptioninstand-bymode75μA•Maximumpowerconsumption50mA (inthecaseofanalarmitislimitedbytheresistorinthebaseortheunit)• Diameter:110mm•Height:54mm•Weight:130g

> BSE100 Standard base

• Itismadefromplasticmaterialandhasamoderndesign• FittedwithresistorforFD102/FD108panels• VersionwithrelaybaseonboardBSE100Rmodelalsoavailable• Diameter:110mm•Height:42mm•Weight:(without)thebase99.4g•Operatingtemperature:(-10÷+60)°C• Relativeoperatinghumidity:(10÷93)%noncondensing• Localwarningindicator(standbyandalarm)-RedLED•ABS+PC(UL94-V0)plasticmaterials

> BRL100 Relay base for conventional detectors: SF100 - SF200 - SF400

Co

nv

en

tio

na

l d

ete

cto

rs

Page 15: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 15

Ala

rm c

all

po

int

> FD 2470 Emergency break glass call pont

• Thermoplasticmaterial• 1change-overcontact•Maxcurrentoncontacts:3A•Maxvoltageoncontacts:75Vcc• HousingProtectionratingIP54• 7self-adhesivesigns•Weight:0.18Kg

> FD 1469 Emergency metal break glass call pont

•Metalemergencybutton• 1change-overcontact•Maxcurrentoncontacts:3A•Maxvoltageoncontacts:75Vcc• Protectionrating(IP)65• 7self-adhesivesigns•Weight:0.46Kg

> FD 2474 Reset device

> FD 2470P Resettable alarm call point

• LikeFD2470butwithresettablealarmcallpoint (AccessoriesforFD2470asperFD2470)

> FD 3480 Low profile emergency call point

• 2change-overcontacts•Maxcurrentoncontacts:3A•Maxvoltageoncontacts:75Vcc• Protectionrating(IP)30• 7self-adhesivesigns•Weight:0.13Kgm

> FD 2475 Red flush-mounting installation frame

Page 16: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

16 | FIRE System

Aco

ust

ic o

pti

cal

dis

pla

y u

nit

s

> FD 5053 Optical acoustic display in thermoplastic material not self-powered

• Flashtubexenolamp0,5μ• Adjustableblinkingfrequency60-90/min.• ProtectionratingIP40• 3phrases• Powersupply24Vdc64mA(also12VinCCandACcurrent)

> FD 5551 Optical acoustic display ip 65 self powered

• Fluorescentlamp-8W• Blinkingfrequency60min.• Protectionrating:IP65• 3phrases• Powersupply:24VdcRechargecurrent100mA

> FD 5553 Optical acoustic display ip 65

> FD FI100 Optical led repeater for individual or group detector alarms

• TherepeaterconnectsdirectlytothedetectorrepeaterconnectorLED•Wallorceilinginstallation,Madefromthermoplasticmaterial• Currentconsumption:4.5mA•Operatingtemperature:-30C°to+70C°• Protectionrating:IP40• Dimensions:80x80x27

• Flashtubexenolamp0,5μ• Adjustableblinkingfrequency60-90/min.• Protectionrating:IP65• 3phrases• Powersupply:24Vdc65mA(also12VinCCandACcurrent)

> FD 1553 Aluminium optical acoustic display

• Flashtubezenolamp0,5Ì• Adjustableblinkingfrequency60-90/min.• Protectionrating:IP40• 5phrases• Powersupply:24Vdc60mA(also12VinCCandACcurrent)

> FD5055 Optical acoustic display

> FD5056 Optical acoustic plate

•Opticalacousticdisplayinmethacrylatepolystyrenenotself-powered• HighbrightnessLED5• ProtectionratingIP44• Absorptioninalarmcondition35mA–12V/45mA–24V• 2phrases• Powersupply12or24Vdc

•OpticalAcousticPlatewithseparateelectronic24Vdc• LED• ProtectionratingIP34• 2phrases• Powersupply24Vdc• Averageconsumption:50mA

*on request

Page 17: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 17

Re

fle

ctiv

e o

pti

cal

be

am

lin

ea

r sm

ok

e d

ete

cto

rs

> FD RK70R Linear optical detector with range of 40 X metres reflecting light

• Smallsizedandstylishdesign• Alarmandpre-alarmlevelindicator• Powersupply:12Vdc24Vac• Currentconsumption:10mA• 0-10Voutputanalogsignalforlevelsignalindication• Interventiondelay:5seconds• Interventiondelay:5seconds• IndicatorLEDS:pre-alarmandalarm• Pre-alarmoutput:OpenCollector(transistorNPN)50mAmax• Alarmrelayoutput:1A/24Vcc•Outputterminalwiththepossibilitytoplacethesignalsatvariousdistances• Polycarbonateplasticcase(redorwhitecaseatchoice–blackcover)• Protectionrating:IP50(IEC529-144)• Dimensions:162x62x63mm•Weight:250g

> FD RK75R Same features as the FDRK70R but with flush-mounting fixture

> FD RK80R Light reflecting linear optical beam detectors

• Powersupply:from11to30Vcc.• Consumption:14mA(receiver)-4mA(transmitter)• Alarm,faultandpre-alarmindicatorLED•Alarmrelayoutput:1A/24Vcc• Pre-alarmoutputOpenCollector(transistorNPN):50mAmax• FaultoutputOpenCollector(transistorNPN):50mAmax• Protectionrating:IP65(IEC529-144)•Maxoperatingrange:2,550m2• Dimensions:247x146x114mm.• Container:polycarbonateplasticmaterial•Weight:900g.

> FD FX0X Reflectors for optical detectors in the FD RK family

> FX01 range 25 m

> FX02 range 40/50m

> FX03 range 70m

• BematchedtoFDFX0X

Page 18: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

20 | FIRE System

Fla

me

de

tect

ors

> FD FL10 Infrared radiation flame detectors

• Smallsized,idealforinstallationonwallsandceilings• Powersupply:12Vcc(FL10/12)or24Vcc(FL10/24)• Currentconsumption:15mA•Maximumdistanceofflamedetection:20m(flametarget20x20cm-height20cm)•Opticalviewingangle:120degrees• Sensitivityregulation• Interventiondelayregulation• Terminalsforremoteoperatingtests• Relayoutput:1A/24Vcc• Casinginself-extinguishingpolycarbonate–ClassV0• Protectionrating:IP34• Dimensions:162x62x63mm•Weight:240g

> FD FL20 Infrared radiation flame detector with two sensors IP65

• 2sensorswithdifferentviewingspectrumidealforindustrialapplication• Forwallorceilinginstallation,wideviewingangle• Casing:self-extinguishingpolycarbonate-IP65• Powersupply:12/24Vcc• Consumption:18mA•Maximumdistanceofflamedetection:20m(flametarget20x20cm-height20cm)•Opticalviewingangle:120degrees• Sensitivityregulation:• Interventiondelayregulation:• Terminalsforremoteoperatingtests• Relayoutput:1A/24Vcc• Casinginself-extinguishingpolycarbonatematerial–ClassV0• Protectionrating:IP65• Dimensions:247x146x114mm•Weight:900g

> FD EV 395 Spark detector IP 65

TheFDEV395sparkdetectorisanelectronicdeviceusedtodetectsparksintubesorpipesconveyingvarioustypesofcombustiblematerialstowardsastoragesilos.• Powersupply:24Vccandca• Solidopticalviewingangle:90degrees• Regulatingsensitivity• Remoteoperatingtests• Protectionrating:IP67• Dimensions:140x135x85

> FD SCL 01 Spark detector IP 65 ATEX version

TheFDSCL-01sparkdetectorisanelectronicdeviceusedtodetectsparksintubesorpipesconveyingvarioustypesofcombustiblematerialstowardsastoragesilos.• ThedeviceisexplosionproofEX-dIIC-T6–ATEXcertified.• Powersupply:12/24Vccandca• Electronicwithmicroprocessor• Solidopticalviewingangle:90degrees• Regulatingsensitivity• Protectionrating:explosionproofEX-dIICT6• Certifications:CESIandATEX• Protectionrating:IP66• Dimensions:200x130mm

> FD EV-521 Control unit for 2 spark detectorsThesparkdetectorcontrolunitisusedwiththerelativedetectors.Itcancontrol1or2nozzlesolenoidvalvestospraywatertoextinguishflames.Itcancontrolrelativeacousticalarms.Automaticactivationofshutterstoblocktheflow.Itcheckstheopeningoftheshuttersusingpressureswitchesonthehydrauliccircuit.• Timers:2adjustable• RemoteTestbuttonsfor2sparkdetectors• Relayoutput:4• Container:inshockproofplasticmaterialwithtransparentflap• Protectionrating:IP54• Dimensions:275x325x110mm

Sp

ark

de

tect

or

Page 19: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 21

Sir

en

s a

nd

be

lls

Ele

ctro

ma

gn

eti

c b

lock

> FD 4476 Fire alarm bell

• Bellforindoorusewithcoverinredenamelledsteel• ProtectionratingIP42• Acousticpressureat1m93/95db• Power24Vdc25mA(availableat12V)• Allowablevoltage18-30Vdc• 4,6or8inchversions• Diameter:150mm•Weight:0.85Kg

> FD 4479 Electronic fire alarm bell

• Bellforoutdoorusewith6”steelcover• ProtectionratingIP55• Acousticpressureat1m93/95db• Power24Vdc30mA(availableat12V)• Allowablevoltage18-30Vdc• Diameter:150mm•Weight:1.1Kg

> FD 4460 28 tone electronic sounder

• ProtectionratingIP57• Acousticpressureat1m100db• Powersupply12/24Vdcconsumption8/16m/A•Allowablevoltage9-28Vdc• Diameter:93mm•Weight:0.31Kg

> NSF20 Outdoor self-powered sounder

> FD M5411 D Metal electromagnetic block

> FD M9412 D Die-cast aluminium electromagnetic block

• Baseandcoverinfire-proofABS(availablealsowithepoxyvarnishedsteelcoverNSE26)• ProtectionratingIP34• Halogenflash• Acousticpressureat3m106db• NC/NOinput• Powersupply:24Vdc• Consumption:2.1mAwhenidle1.05Ainalarmstatus• Dimensions:210x255x65mm•Weight:1.4Kg

• Electromagneticdoorblockinsteelhousing• Comeswithreleasebuttonandprotectiondiode(Alsoavailablewithnodiode)• Suppliedwithacounterplateandelectricalconnection• Fittedwithdoublecablesheath• Retainingforce:40N• Protectionrating(IP)42• Powersupply12Vdc• Consumption:2W

• Electromagneticdoorblockinreinforcedvandal-proofaluminiumhousing• Comeswithreleasebuttonandprotectiondiode• Retainingforce:40N• Fittedwithvandal-proofreel• Protectionrating(IP)52• Powersupply:24Vdc• Consumption:2W

Page 20: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

22 | FIRE System

> TD 40-27 Power units certified to ien 54 4 standards

•Managementofupto16loopedpowerunits• CertifiedtoEN54-4N°0051-CPD-0072standards• Type:Switching230/240V~24V/1A50Hz•Outputadjustment:+-10%• Shortcircuit,overload,overvoltageprotection•Maximalcurrentdeliverabletoexternalunits:1.5A• Batterychargecurrent0.2A• Alarmsignalsonfreepotentialcontacts• TamperPowerfailuresignal• Nopowersupplytotheexternalloadssignal• Lowbatterysignal• OpticalLEDindicationof:• 230Vacpowersupplypresence,lowbattery,batteryabsence,lowbatterychargercircuit• Inmetalcabinetwithhousingforn°2accumulatorsupto4Ah• Dimensions:290x250x180•Weight:Kg.5

> TD 60-27 Power units certified to ien 54 4 standards

•Managementofupto16loopedpowerunits• CertifiedtoEN54-4N°0051-CPD-0074standards• Switchingtype:230/240V~27,6V/2,5A50Hz•Outputadjustment:+-10%• Shortcircuit,overload,overvoltageprotection•Maximalcurrentdeliverabletoexternalunits:2.5A• Batterychargecurrent0.2A• Alarmsignalsonfreepotentialcontacts• TamperPowerfailuresignal• Nopowersupplytotheexternalloadssignal.• Lowbatterysignal.• OpticalLEDindicationof:230Vacpowersupplypresence,lowbattery,batteryabsence, lowbatterychargercircuit• Inmetalcabinetwithhousingfor2accumulatorsupto7Ah• Dimensions:450x260x205•Weight:Kg.8.5

> TD 150-27 Gruppo di alimentazione CERTIFICATO IEN 54 4

•Managementofupto16loopedpowerunits• CertifiedtoEN54-4N°0051-CPD-0075standards• Switchingtype:230/240V~27,6V/5.6A50Hz•Outputadjustment:+-10%• Shortcircuit,overload,overvoltageprotection•Maximalcurrentdeliverabletoexternalunits:5A• Batterychargecurrent0.6A•Alarmsignalsonfreepotentialcontacts• TamperPowerfailuresignal• Nopowersupplytotheexternalloadssignal.• Lowbatterysignal.• OpticalLEDindicationof:Networkavailable,lowbattery,nobattery,lowbattery,chargercircuit• Onwallcabinets,abletohousestoragebatteriesupto2x17Ah• Dimensions:450x260x205•Weight:Kg.11

Ad

ap

tors

an

d p

ow

er

sup

ply

un

its

Page 21: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 23

Op

en

fra

me

ad

ap

tors

> S-150-27• Switchingtype:230V/27,6V-5.6A50Hz• DCAdjustment+-10%• Protectionagainst:shortCircuit,overload,powersurge• Dimensions:199x50x110•Weight:Kg.0.8• Standard:CEIEN60950-CEI79/2

> S-60-27• Switchingtype:230V/27,6V-3,7A50Hz• DCAdjustment+-10%• Protectionagainst:shortCircuit,overload,powersurge• Dimensions:159x97x38mm.•Weight:Kg.0.55• Standard:CEIEN60950-CEI79/2

> Cavo 32101 Red twisted grade 3 shielded fire-proof cable diameter 2 x 1 mm

> Cavo 32151 Red twisted grade 3 shielded fire-proof cable diameter 2 x 1,50 mm

> Bat1201 Rechargeable lead batteries 12Vdc 1,22 Ah 97L x 43P x 51A mm > Bat1202 Rechargeable lead batteries 12Vdc 2 Ah 178L x 35P x 61A mm > Bat1207 Rechargeable lead batteries 12Vdc 7 Ah 151L x 65P x 94A mm > Bat1212 Rechargeable lead batteries 12Vdc 12 Ah 151L x 99P x 95A mm > Bat1217 Rechargeable lead batteries 12Vdc 17 Ah 181L x 76P x 167A mm > Bat1225 Rechargeable lead batteries 12Vdc 25 Ah 166L x 175P x 125A mm > Bat1240 Rechargeable lead batteries 12Vdc 40 Ah 197L x 165P x 170A mm

Ca

ble

sB

att

eri

es

Page 22: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

24 | FIRE System

NOTE

Page 23: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks

www.teledata-i.com

FIRE System

FIRE System | 25

NOTE

Page 24: FIRE System - UMO Enterprises | competence in securityumo-enterprises.ro/echipamente/FireCatalogue.pdf · FIRE System ... on RS232 serial lines or LAN and WAN geographical networks