ADPRO® FastTrace™ 2 Series by Xtralis Quick Setup Guide

March 16, 2015 Doc. 21778_06 Software version XOa 3.00.0005

ADPRO® FastTrace™ 2 Series Quick Setup Guide

21778_06 3

Disclaimer

The contents of this document are provided on an "as is" basis. No representation or warranty (either express or implied) is made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded.

Intellectual Property and Copyright

This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their respective owners. Your use of this document does not constitute or create a license or any other right to use the name and/or trademark and/or label. This document is subject to copyright owned by Xtralis. You agree not to copy, communicate to the public, adapt, distribute, transfer, sell, modify, or publish any contents of this document without the express prior written consent of Xtralis.

General Warning

This product must only be installed, configured and used strictly in accordance with the General Terms and Conditions, User Manual and product documents available from Xtralis. All proper health and safety precautions must be taken during the installation, commissioning, and maintenance of the product. The system should not be connected to a power source until all the components have been installed. Proper safety precautions must be taken during tests and maintenance of the products when these are still connected to the power source. Failure to do so or tampering with the electronics inside the products can result in an electric shock causing injury or death and may cause equipment damage. Xtralis is not responsible and cannot be held accountable for any liability that may arise due to improper use of the equipment and/or failure to take proper precautions. Only persons trained through an Xtralis accredited training course can install, test and maintain the system.

Liability

You agree to install, configure, and use the products strictly in accordance with the User Manual and product documents available from Xtralis.

Xtralis is not liable to you or any other person for incidental, indirect, or consequential loss, expense or damages of any kind including without limitation, loss of business, loss of profits, or loss of data arising out of your use of the products. Without limiting this general disclaimer the following specific warnings and disclaimers also apply:

Fitness for Purpose

You agree that you have been provided with a reasonable opportunity to appraise the products and have made your own independent assessment of the fitness or suitability of the products for your purpose. You acknowledge that you have not relied on any oral or written information, representation, or advice given by or on behalf of Xtralis or its representatives.

Total Liability

To the fullest extent permitted by law that any limitation or exclusion cannot apply, the total liability of Xtralis in relation to the products is limited to: (i) in the case of services, the cost of having the services supplied again; or (ii) in the case of goods, the lowest cost of replacing the goods, acquiring equivalent goods or having the goods repaired.

Indemnification

You agree to fully indemnify and hold Xtralis harmless for any claim, cost, demand, or damage (including legal costs on a full indemnity basis) incurred or which may be incurred arising from your use of the products.

Miscellaneous

If any provision outlined above is found to be invalid or unenforceable by a court of law, such invalidity or unenforceability will not affect the remainder which will continue in full force and effect. All rights not expressly granted are reserved.

Document Conventions

The following typographic conventions are used in this document.

Convention Description

Bold Used to denote: emphasis Used for names of menus, menu options, toolbar buttons

Italics Used to denote: references to other parts of this document or other documents. Used for the result of an action

The following icons are used in this document.

Icon Description

Note. This icon indicates information of special interest that will help the reader make full use of the product, optimise performance, etc. Failure to read the note will not result in physical harm to the reader, or damage to equipment or data.

Caution! This icon indicates danger to equipment. The danger can be loss of data, physical damage to the equipment, or permanent corruption of configuration details.

Warning! This icon indicates danger of physical harm to the reader. Not following instructions may lead to death or permanent injury.

Warning! This icon indicates danger of electric shock. This may lead to death or permanent injury.

Warning! This icon indicates that there is a danger of inhaling dangerous substances. This may lead to death or permanent injury.

Quick Setup Guide ADPRO® FastTrace™ 2 Series

4 21778_06

Trade Name Statement

ADPRO is a registered trademark of Xtralis Pty Ltd.

Contact Us

UK and Europe +44 1442 242 330 D-A-CH +49 431 23284 1 The Americas +1 781 740 2223

Middle East +962 6 588 5622 Asia +86 21 5240 0077 Australia and New Zealand +61 3 9936 7000

www.xtralis.com

ADPRO® FastTrace™ 2 Series Quick Setup Guide

21778_06 5

Contents

1 Packing List ........................................................................................................................................... 6

2 Power Requirements ............................................................................................................................. 6

3 Safety Instructions ................................................................................................................................ 6

4 Technical Documents ........................................................................................................................... 6

5 Installing the XOa Client Software on Your Computer ...................................................................... 6

5.1 XOa Client – Minimum System Requirements ......................................................................... 6 5.1.1 Hardware ......................................................................................................................... 6 5.1.2 Software ........................................................................................................................... 7

5.2 Preparing Your PC for Installation ............................................................................................ 7 5.2.1 Internet Explorer Settings ................................................................................................ 7 5.2.2 Changing the PC’s IP Address ........................................................................................ 8

5.3 Installing the XOa Client Software ............................................................................................ 8

6 Launching the XOa Client ................................................................................................................... 11

7 Adding a Server to the XOa Client ..................................................................................................... 12

8 Connecting to a Server ....................................................................................................................... 13

Quick Setup Guide ADPRO® FastTrace™ 2 Series

6 21778_06

1 Packing List After unpacking, check for any signs of damage. Report any damage to your supplier immediately. Also check whether all items are present:

ADPRO® FastTrace™ 2 server unit

Power cord

CD with client software and manuals

Quick Setup Guide

19" mounting brackets, black

Set of resistors (if fitted with Main or Extension input/output card)

Set of 4 rubber feet to use the FastTrace 2 as a desktop unit.

The products are provided with a plug according to the National Heavy Current Regulations of the country of shipment. Installation shall be done according to National Regulations.

2 Power Requirements The ADPRO FastTrace 2 is designed for 100–240 VAC 50–60 Hz operation. It shall not share electrical outlets or circuits with devices that may cause significant electrical interference, such as air conditioners or photocopiers.

Some installations may have particularly bad mains power disturbances, such as large voltage spikes, surges, and power sags which may cause system failure. In this case, power line filters/conditioners and/or uninterruptible power supplies shall be fitted between the ADPRO FastTrace 2 and the mains.

3 Safety Instructions The plug is the disconnect device for the FastTrace 2 server. The outlet socket must be installed near the server and must be easily accessible.

4 Technical Documents Please download the FastTrace 2 Hardware Installation Manual and XOa Client Software User Manual from our website www.xtralissecurity.com. You can also download technical data sheets on specific devices that connect to the FastTrace 2.

5 Installing the XOa Client Software on Your Computer

5.1 XOa Client – Minimum System Requirements

5.1.1 Hardware

Core 2 Duo, 1.6 GHz

2 GB RAM

Graphics card that is compatible with DirectX 7

Xtralis recommended to use a graphics card that allows YUV surfaces and hardware stretching. If not, the XOa client software will force the graphics card to GDI mode, which will increase CPU load.

ADPRO® FastTrace™ 2 Series Quick Setup Guide

21778_06 7

It is recommended to install the latest drivers of your graphics card. For NVIDIA cards, check http://www.nvidia.com. For ATI/AMD cards, check http://ati.amd.com

If necessary, you can always force the client into GDI mode (not recommended, because of CPU load). Add the line ‘gdi=1’ in the [General] section of the hydra.ini file. The default location for this file is C:\Users\username\Appdata\Roaming\AdproXOa\ (where username is the name of the Windows user that is currently logged on).

Caution!

These minimum system requirements enable you to configure the server from the client software. However, if you want to use HD cameras in optimal quality, these minimum requirements will prove insufficient. Please take into account that double resolution, on average, results in 4 times more performance. Xtralis advises to test the settings to make sure that your PC can handle your configuration.

5.1.2 Software

Windows XP, Windows Vista, Windows 7, Windows 8, Windows 8.1

Internet Explorer 8 or higher

DirectX 7 drivers.

5.2 Preparing Your PC for Installation

5.2.1 Internet Explorer Settings

Note

The preferred browser for installing the XOa client software is Internet Explorer. If you cannot use Internet Explorer, try any other internet browser. In this case, you must install the MeadCo Neptune plugin. You can download the plugin from www.meadco.com/Neptune/Download.

When installing the XOa client software on a Windows Vista or Windows 7 operating system, you need to add the server’s IP address to your Trusted sites in Internet Explorer. Proceed as follows:

1. In Internet Explorer, choose Tools > Internet options.

2. Click the Security tab.

3. In the Select a zone… box, click Trusted sites, and click Sites.

4. In the Add this website… box, type http:// followed by the server’s IP address. For example: http://10.0.0.10

5. Click Add, and then click Close.

6. Click OK to close the Internet Options window.

If installation is still not possible, you may try clearing the Protected Mode check box in the Security tab.

Caution!

Check with the IT department if you are allowed to switch off protected mode, because this may cause IT issues.

Quick Setup Guide ADPRO® FastTrace™ 2 Series

8 21778_06

5.2.2 Changing the PC’s IP Address

The server’s default IP address is 10.0.0.10 with subnet mask 255.255.255.0. When you install the client software, you need to put your PC in the same IP range (e.g. IP address 10.0.0.2 with subnet mask 255.255.255.0).

5.2.2.1 In Windows XP

To change the PC’s IP address in Windows XP, proceed as follows:

1. Click Start and choose All Programs > Accessories > Communications > Network Connections.

2. Right-click Local Area Connection, and then click Properties.

3. Click Internet Protocol (TCP/IP), and then click Properties.

4. For ease of initial setup, change the PC’s TCP/IP settings as follows:

IP address 10.0.0.2

Subnet mask 255.255.255.0

5. Click OK. The Local Area Connection Properties window appears again.

6. Click OK, and then close the Network and Dial-up Connections window.

5.2.2.2 In Windows Vista/Windows 7

To change the PC’s IP address in Windows Vista/Windows 7, proceed as follows:

1. Click Start, and then click Control Panel (View by: Category).

2. Click Network and Internet.

3. Click Network and Sharing Center.

4. Click Change adapter settings.

5. Right-click Local Area Connection, and then click Properties.

6. Click Internet Protocol Version 4 (TCP/IPv4), and then click Properties.

7. For ease of initial setup, change the PC’s TCP/IP settings as follows:

IP address 10.0.0.2

Subnet mask 255.255.255.0

8. Click OK to return to the Local Area Connection window.

9. Click OK to close the window.

5.3 Installing the XOa Client Software

Note

The procedure below describes how to install the XOa client software on a new system. For upgrading your legacy FastTrace 2 server, see Field Alert #6 – Upgrading to XOa 3.

To install the XOa client software, proceed as follows:

1. Connect your PC to the server’s ETH0 port with an RJ45 network cross cable or via the network switch/router on the ETH0 port.

Note

The illustration below shows a server with a MiTAC PH10LU motherboard. To locate the ETH0 port on systems with Intel motherboards, see the FastTrace 2 Hardware Installation Manual.

ADPRO® FastTrace™ 2 Series Quick Setup Guide

21778_06 9

2. Open Internet Explorer and enter the server’s IP address, followed by /setup.php For example: http://10.0.0.10/setup.php

3. Click setup.exe.

4. Click Run to start the installation.

Note

Your virus scanner may block this download. Disable your virus scanner temporarily if this occurs. Remember to switch it back on after installation.

5. The following warning message may appear: Do you want to allow the following program from an unknown publisher to make changes to this computer? Click Yes to start the installation.

Quick Setup Guide ADPRO® FastTrace™ 2 Series

10 21778_06

6. Click I Agree to agree with the terms of the license agreement.

7. Accept or modify the installation folder. Click Next.

8. Accept or modify the work folder (= the folder for storing snapshots and downloaded recordings). Also select your preferred language. Click Install.

9. When the installation is completed, click Close to exit the installation Wizard.

ADPRO® FastTrace™ 2 Series Quick Setup Guide

21778_06 11

6 Launching the XOa Client To launch the XOa client, proceed as follows:

1. On the desktop, double-click the XOa client icon . If the icon is not available, you can click Start and choose All Programs > ADPRO XOa > AdproXOa. The following window appears:

The Login window displays all your servers so that you can quickly connect to them. When using the XOa client for the first time, the list is empty.

2. To set up how the client launches, click Settings.

3. Select the desired language for the application.

4. In the GUI style box, select a style to change the appearance of the application.

5. If required, in the Path box, change the work folder (= the folder for storing snapshots and downloaded recordings).

6. Set Save live view to Yes if you want to show the last used camera matrix in live view. If you set it to No, the live view window is empty when you start the client, and you have to select the cameras for the live view matrix each time you start the client.

7. Set Auto restart to Yes if you want the login window to reappear when you close the client software. This allows you to quickly connect to another server.

8. Click OK to save the settings.

You can now add a server and connect to it.

Quick Setup Guide ADPRO® FastTrace™ 2 Series

12 21778_06

7 Adding a Server to the XOa Client To add a server, proceed as follows:

1. Launch the XOa client (in its own window).

2. Click Add. The following window appears:

3. Provide the following information:

- In the Name box, type a meaningful name for the server.

- In the IP Address box, type the IP address or DNS hostname of the server (default is 10.0.0.10).

- Enter the RTSP Port (default is 554) and Control Port (default is 2000).

- In the Connection Type box, select the TCP or UDP protocol. UDP is recommended, but TCP may be required if the connection goes through a router that blocks the UDP packets.

- Enter the user ID/username and password of an existing user to log on to the server. The default user ID is 0 and the default password is 666777.

4. Click OK. The new server appears in the list.

ADPRO® FastTrace™ 2 Series Quick Setup Guide

21778_06 13

8 Connecting to a Server To connect to a server, proceed as follows:

1. Launch the XOa client.

2. Click the server in the list, and then click Connect. The Live Video screen appears:

Quick Setup Guide ADPRO® FastTrace™ 2 Series

14 21778_06

www.xtralis.com

UK and Europe +44 1442 242 330 D-A-CH +49 431 23284 1 The Americas +1 781 740 2223

Middle East +962 6 588 5622 Asia +86 21 5240 0077 Australia and New Zealand +61 3 9936 7000

A Disclaimer about this document, statements about Intellectual Property, Copyrights, and Liability, as well as a General Warning are available in an earlier section of this document. Doc. 21778_06 P/N 19531912