67
608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/11862 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

21621 SE 281st St, Maple Valley, WA 98038

March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/11862 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Page 2: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc.Property Inspection Report

Cover Page

21621 SE 281st St, Maple Valley, WA 98038Inspection prepared for: Faira .com

Real Estate Agent: -

Date of Inspection: 3/23/2018 Time: 1:30 PM Age of Home: 2003 Size: 1870

Order ID: 3452

Inspector: Robert PickeringLicense #1807

Email: [email protected]

Page 3: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 1 of 65

General Exterior Note 1. Exterior Note

||2||North Elevation ||2||East Elevation

||2||West Elevation ||2||South Elevation

Page 4: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 2 of 65

Exterior Areas 1. Siding ConditionSiding appeared in good condition overall. • LP Oriented Strand Board SidingObservations:• Vent cover blocked, Recommend cleaning for adequate air flow.• Some siding nails need to be reset.• Vent wells damaged/decayed. Recommend replacement.• Foliage contact with siding, recommend pruning or removing any plants that are in contact orproximity to home to eliminate pathways of wood destroying insects.• Paint flaking at the trim, recommend loose paint is removed, barewood areas primed andrepainted.• Some areas of LP siding that show signs of water damage/swelling/Failing. Recommendconditions are investigated further and corrected by licensed Siding Contractor.

West

Page 5: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 3 of 65

West South

South South

East

Page 6: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 4 of 65

East East

2. GuttersGutters and downspouts appeared in good condition overall.Observations:• Debris in gutters, recommend cleaning gutters.• Indications of water running in behind gutters, staining on the fascia, recommend furtherinvestigation and correction

Page 7: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 5 of 65

3. Driveway and Walkway ConditionConcrete sidewalks and driveways appeared in good condition overall.

4. SoffitSoffits and eaves appeared in good condition overall.Observations:• Fungal growth at the soffit, areas would need to be cleaned, sealed and repainted.• Fascia tails decaying, recommend repair.

Page 8: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 6 of 65

North upper South

East Upper

Left of entry

Page 9: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 7 of 65

5. Door/WindowExterior doors appeared in operable condition, at time of inspection. • Threshold and jambsappeared in good condition overall. • Window frames and sills appeared in good condition overall.Observations:• There was no visible flashing above the window north upper. Windows and or doors withoutflashing require periodic maintenance of caulking material.

6. GradingGrading appeared in good condition overall.

7. ElectricalExterior outlets operate overall • Exterior outlets are GFCI protected overall

8. Cable FeedsMaterials: Primary Service is Underground Service Lateral

9. Gas ConditionMeter located at west side. Main Gas shutoff is located to the lower left of the meter.

Page 10: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 8 of 65

10. Exterior Faucet ConditionObservations:• Hose bib at west side of house leaks from packing nut.• Hose bib at south side of house leaks.

South West11. Pressure70

Page 11: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 9 of 65

12. Gate ConditionMaterials: WoodObservations:• Fences are NOT INCLUDED as part of a home inspection.• Gate hardware missing or damaged; gate will not secure.

Page 12: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 10 of 65

Roof 1. Roof ConditionArchitectural Composition shingle.Type Average life span 30 years for this type surface with proper maintenance and care.Observations:• Areas of moss on roof. This can lead to the premature failure of the roof and subsequent leaks.Recommend treating moss with a moss retarding chemical. Pressure washing is not recommendedas it can damage surface and lessen life span.• Recommend following conditions are investigated further by licensed roofing contractor andconditions corrected as required.• Granular surfacing deteriorated. Recommend further investigation by licensed roofing contractor

Page 13: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 11 of 65

2. SkylightsSkylights appeared sealed, no visible indications of leakage.Observations:• Failed insulated glass seal at skylight, recommend conditions are repaired by licensed roofingcontractor or glass company.

Page 14: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 12 of 65

South North

Page 15: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 13 of 65

Attic 1 1. AtticGarage is location of access.

2. FramingVisible framing appeared in good condition overall, no visible indications of decay or waterpenetration presently.

Page 16: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 14 of 65

3. VentilationVentilation appeared adequate overall.

4. Fan/DuctFurnace appeared to exhaust to the exterior overall.

Page 17: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 15 of 65

5. Insulation ConditionObservations:• No insulation present. Attic is over garage.

6. Rodent/PestsNo visible indications of Rodent Activity.

Page 18: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 16 of 65

Attic 2 1. AtticAttic access is located in the hallway

2. FramingVisible framing appeared in good condition overall, no visible indications of decay or waterpenetration presently.Observations:• There is a whitish and or darkened coloration that possibly could be a fungal/mold growth.Conditions are generally a result of excessive moisture at some point or inadequate ventilation.Treating/remediation and correction moisture conditions will help prevent future occurrences.Testing would need to be performed to determine the presence or absence of Mold. Testing mayinclude surface sampling and air quality testing.

South North

Page 19: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 17 of 65

Near skylight south

North3. Ventilation

Page 20: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 18 of 65

4. Fan/DuctBathroom fans appeared to exhaust to the exterior overall.

5. Insulation ConditionBlown in fiberglass insulation noted.Depth: Insulation averages about 16-18 inches in depth, estimated R value 49.

6. Rodent/PestsNo visible indications of Rodent Activity.

Page 21: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 19 of 65

General Interior Note 1. General NotesMaterials: Windows in the home are Double pane insulated glass windows. Any deficiencies arenoted in each room section for accessible windows • Doors in the home are considered operationalunless otherwise noted in each room section • Cabinet doors and in the home are consideredoperational unless otherwise noted in each room section

Page 22: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 20 of 65

Entryway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. Entry door operates andlocks overall. • Wood flooring is in good condition overall.

2. FloorObservations:• Wood floor finish faded/worn

Page 23: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 21 of 65

Living Room 1. LocationLocation Northeast

2. Living RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

3. ElectricalMaterials: Top halves of outlet on the east wall switch controlled.

Page 24: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 22 of 65

Dining Room 1. LocationLocation East

2. Dining RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.

Page 25: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 23 of 65

Kitchen 1. Kitchen RoomWalls and ceilings appear in good condition overall. Flooring is linoleum. Heat register present.Accessible outlets operate. Light fixture operates. Sink and faucets are in operable conditionoverall. Cabinet doors and drawers are in operable condition overall.

2. Counter ConditionFormica counter is in good condition overall.Observations:• Formica counter damaged.

3. CabinetCabinet doors and drawers are in operable condition overall.

4. DisposalDisposal operates overall.

5. DishwasherDishwasher was in operable condition.

Page 26: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 24 of 65

6. MicrowaveObservations:• Built-in microwave ovens are tested using normal operating controls. Unit was tested andappeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scopeof this inspection. If concerned, client should seek further review by qualified technician prior toclosing.• Light is inoperable, may be a blown bulb

7. FloorObservations:• Damaged linoleum

8. Stove/OvenStove/oven were in operable condition overall.

Page 27: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 25 of 65

9. RefrigeratorRefrigerator was in operable condition.

10. SinksSinks are in operable condition overall.Observations:• Sink chipped (Cosmetic; does not affect function).

Page 28: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 26 of 65

11. ElectricalOutlets are GFCI protected at the counters.Observations:• No GFCI protection present on south wall right and left of sink, strongly recommend conditionsare investigated further and corrected as required by licensed electrical contractor.• GFCI outlet would not trip with tester on east wall GFCI trip test, strongly recommend conditionsare investigated further and corrected as required by licensed electrical contractor.

12. Vent ConditionVent fan appears to exhaust to the exterior.

13. HeatingHeat register operates.

Page 29: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 27 of 65

Family Room 1. LocationLocation Southwest

2. Family RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.

3. FloorObservations:• Carpet staining.

4. FireplaceFireplace is a gas unit. • Fireplace appeared in operable condition.Observations:• Gas shutoff is located at the wall adjacent to the fireplace.• Pilot Controls are located inside access panel under glass.• Recommend cleaning fireplace glass, if discoloration is left for long periods it can become etchedin the glass.

Page 30: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 28 of 65

Page 31: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 29 of 65

1/2 Bathroom 1. Location1st Floor

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.Toilet was in operable condition overall .

3. CounterTile counter tops are in good condition overall.

4. CabinetCabinet doors are in operable condition overall.

5. SinksSinks are in operable condition overall.

6. ElectricalGFI outlets within 6 feet of the sink.

7. Exhaust FansVent fan operates overall.

8. FloorsLinoleum Flooring is in good condition overall.

9. ToiletToilet was in operable condition overall.

10. HeatingHeat register operates.

Page 32: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 30 of 65

Laundry 1. Location1st Floor

2. ConditionCeiling and walls are in good condition overall. Accessible outlets operate. • Light fixture operates.

3. ElectricalGFI outlet east wall.

4. Exhaust FansVent fan operates overall.

5. DryerDryer appeared to exhaust to the exterior.

6. Floor ConditionLinoleum Flooring is in good condition overall.Observations:• Damaged linoleum near entry

Page 33: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 31 of 65

Garage entry7. HeatingHeat register operates.

8. Window DeficienciesObservations:• Latch hardware difficult to operate at one or more locations. Recommend investigation and repairas needed by qualified window contractor.• Broken tension bar on window frame. This is a "Safety Concern". Tension bar holds window inopen position. Window would not stay in the open position. Suggest repairs/replacement asneeded to ensure safety.

9. WasherMaterials: Washer faucets were in operable condition, no visible leakage.Observations:• Washer not tested hose bibs were not turned on.

Page 34: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 32 of 65

Page 35: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 33 of 65

Stairs Leading to 2nd Floor 1. StairSteps appeared uniform. • Handrail appeared secure.

Page 36: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 34 of 65

Upstairs Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Carpet floor covering is ingood condition.

2. DoorsObservations:• Closet door not installed

Page 37: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 35 of 65

Master Bedroom 1. BedroomWalls and ceilings appear in good condition overall. Flooring is carpet in good condition. Heatregister present. Accessible outlets operate.Observations:• Cracking at the ceiling does not appear unusual.• Slight wall damage noted

Behind entry door2. ElectricalMaterials: Top halves of outlet on the north wall switch controlled

Page 38: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 36 of 65

3. FloorObservations:• Carpet staining.

4. HeatingHeat register operates.

5. Window DeficienciesObservations:• Discoloration/condensation between the panes. This is an indication of a failed seal. Recommendconditions are corrected by licensed glass company.• Voids in sealant at window casing recommend sealing.

Page 39: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 37 of 65

Page 40: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 38 of 65

Master Bathroom 1. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.Observations:• Nail pops at ceiling do not appear unusual.

Master closet2. ElectricalGFI outlets within 6 feet of the water sources.

3. CountersTile counter tops are in good condition overall.

4. CabinetsCabinet doors are in operable condition overall.

Page 41: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 39 of 65

5. SinksSinks are in operable condition overall.Observations:• Stopper did not seal tight or function correctly.• Sinks slightly rusted. Recommend monitoring.

Right

Right Left6. Exhaust FansVent fan operates overall.Observations:• Exhaust fan vibrates or is excessively noisy. The fan may eventually need to be replaced tocorrect this condition.

7. FloorsLinoleum Flooring is in good condition overall. • Carpet floor covering is in good condition.

Page 42: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 40 of 65

8. ShowerShower is in good condition overall.Observations:• Voids in the grout between some of the tile, recommend resealing.• Voids in the caulking/grout where shower walls rest on floor.

9. ToiletToilet was in operable condition overall.

10. HeatingHeat register operates.

Page 43: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 41 of 65

Hall Bathroom1 1. LocationMaterials: Upstairs

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.Observations:• Ceiling cracks did not appear unusual.

3. ElectricalGFI outlets within 6 feet of water sources.

4. CountersCounter tops are in good condition overall.

5. CabinetsCabinet doors and drawers are in operable condition overall.

6. Exhaust FansVent fan operates overall.

7. FloorsLinoleum Flooring is in good condition overall.

8. TubTub and shower were in good condition overall.Observations:• Voids in the caulking/grout where tub rests on floor, recommend resealing.

Page 44: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 42 of 65

9. SinksSinks are in operable condition overall.Observations:• Stopper did not seal tight or function correctly.• Stains from presumed past leaks noted.

10. ToiletToilet was in operable condition overall.

11. HeatingHeat register operates.

Page 45: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 43 of 65

Bedroom 1 1. LocationLocation Northeast

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.

3. FloorObservations:• Carpet damage near entry.

4. HeatingHeat register operates.

Page 46: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 44 of 65

Bedroom 2 1. LocationLocation Southeast

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.

3. FloorObservations:• Carpet staining.

4. HeatingHeat register operates.

Page 47: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 45 of 65

Bedroom 3 1. LocationLocation South

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.

3. FloorObservations:• Carpet staining.

4. HeatingHeat register operates.

Page 48: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 46 of 65

Garage 1. ConditionWalls and ceilings appeared in good condition overall. Accessible outlets operate. Light fixturesoperate overall. Flooring is concrete, visible portions in good condition overall.

2. Floor ConditionMaterials: Flooring is concrete, appeared in good condition overall.Observations:• Cracking at the floor does not appear unusual.

3. DoorsEntry door is in operable condition overall.

4. Garage DoorsSingle garage door operates, was on auto opener. • Photo cell safety returns operate overall. •Tension safety returns operate overall.Observations:• Garage vehicle door sensors mounted higher than the standard auto-reverse height. Maximumrecommended height 6 inches. Recommend adjustment as a safety precaution.

Page 49: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 47 of 65

Right Left

Page 50: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 48 of 65

Heat/AC 1. Heating TypeGas forced air furnace.

2. Heater Location The furnace is located in the garageFurnace is Goodman Brand • 4 years of age approximately, average life span is 18 to 22 years.

3. Heating conditionObservations:• Service does not appear to have been performed within the last year, recommend serviced bylicensed HVAC contractor.

Page 51: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 49 of 65

4. Venting

5. FiltersLocation: Filter located above furnace.Observations:• The furnace filter is dirty. Filters clean the air before it passes through the blower and heatexchanger. This helps to keep these furnace components working efficiently. Dirty Filters lessen lifespan of the Heating/AC equipment. It is recommended to change the filter and then regularinspection & maintenance is advised.

Page 52: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 50 of 65

6. Fresh AirFurnace is equipped with timer operated fresh air exchange. This system should typically operate15 minutes per hour for proper fresh air exchange.

Page 53: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 51 of 65

Plumbing/Water Heater1 1. PlumbingWater lines were CPVC plastic. • Drain and waste lines were plastic.

2. Water Heater ConditionHeater Type: Gas Water heater. • 40 gallonsLocation: The heater is located in the garage.

3. AgeApproximately 16 years of age, average life span is 10 to 12 years.Observations:• Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring orreplacement.• Approximately 16 years of age, average life span is 10 to 12 years.

Page 54: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 52 of 65

4. ConditionSeismic straps are in place. • Expansion tank is in place.

5. TPRV ConditionTemperature Pressure Relief Valve (TPR Valve) present.

Page 55: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 53 of 65

Electrical 1 1. LocationMaterials: Located in the Garage

2. Electrical200 AMP service, 4/0 Aluminum service entrance wires.

3. GroundingElectrical service is grounded and bonded.

4. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.

5. Arc Fault CircuitsArc Fault Circuits in the panel for bedroom lights and outlets.

6. SubpanelObservations:• Generator sub panels are out side the scope of this inspection

Page 56: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 54 of 65

Foundation/Crawlspaces 1. LocationEntryway closet.

2. FoundationContinuous concrete foundation visible portion appeared in good condition overall.

3. DrainageCrawlspace area was dry, there were no visible indications of standing water presentlyObservations:• Staining on plastic vapor barrier, recommend monitoring

Page 57: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 55 of 65

4. FramingVisible framing appeared in good condition overall.

5. VentilationVentilation appeared adequate.

6. Insulation ConditionUnfinished fiberglass batts noted.Depth: Insulation averages about 6 inches in depth; estimated R value 19, newer requirements areR30 insulation content.Observations:• Insulation damaged/missing in areas of the crawlspace, recommend conditions are corrected.

Page 58: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 56 of 65

7. DuctsDucts appeared securely attached and insulated overall.

8. Vapor BarrierVapor Barrier was in place.

9. RodentObservations:• Indications of Rodent activity,some rodent droppings can carry disease, recommend conditionsare investigated further by licensed Pest Control Company.• Droppings present.

Page 59: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 57 of 65

10. ElectricalObservations:• Low voltage wiring on the floor of the crawlspace. Recommend wiring is secured to the base ofthe framing as a safety precaution

11. PlumbingObservations:• Water lines are not insulated or completely insulated, recommend insulating water lines to preventfreezing.

Page 60: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 58 of 65

Page 61: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 59 of 65

Shutoffs 1. Shutoff Locations

Main water shutoff is located on the east wall ofthe garage.

Hose bib water shutoff is located on the east wallof the garage.

||2||Water Heater gas shutoff is located to the leftof the water heater.

||2||Furnace gas shutoff is located to the right ofthe Furnace.

Page 62: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 60 of 65

||2||Water heater water line shutoff is located above the water heater.

Page 63: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 61 of 65

Equipment 1. Appliances/Equipment

||2||Microwave ||2||Stove

||2||Refrigerator ||2||Dishwasher

Page 64: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 62 of 65

||2||Dryer ||2||Washer

Furnace Water Heater

Page 65: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 63 of 65

GlossaryGlossary

Term DefinitionExpansion Tank An expansion tank or expansion vessel is a small tank used to

protect closed (not open to atmospheric pressure) water heatingsystems and domestic hot water systems from excessivepressure. The tank is partially filled with air, whosecompressibility cushions shock caused by water hammer andabsorbs excess water pressure caused by thermal expansion.

GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.

TPR Valve The thermostat in a water heater shuts off the heating sourcewhen the set temperature is reached. If the thermostat fails, thewater heater could have a continuous rise in temperature andpressure (from expansion of the water). The temperature andpressure could continue to rise until the pressure exceeds thepressure capacity of the tank (300 psi). If this should happen, thesuper-heated water would boil and expand with explosive force,and the tank would burst. The super-heated water turns to steamand turns the water heater into an unguided missile. To preventthese catastrophic failures, water heaters are required to beprotected for both excess temperature and pressure. Usually, themeans of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Mostof these devices are set to operate at a water temperature above200° F and/or a pressure above 150 psi. Do not attempt to testthe TPR valve yourself! Most water heating systems should beserviced once a year as a part of an annual preventivemaintenance inspection by a professional heating and coolingcontractor. From Plumbing: Water Heater TPR Valves

Page 66: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 64 of 65

Report SummaryReport Summary

The summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expense to correct or items I would like to draw extra attentionto. The summary is not a complete listing of all the findings in the report, and reflects the opinion ofthe inspector. Please review all pages of the report as the summary alone does not explain all of theissues. All repairs should be done by a licensed & bonded tradesman or qualified professional. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.Exterior AreasPage 2 Item: 1 Siding Condition • Some areas of LP siding that show signs of water

damage/swelling/Failing. Recommend conditions areinvestigated further and corrected by licensed SidingContractor.

RoofPage 10 Item: 1 Roof Condition • Recommend following conditions are investigated further by

licensed roofing contractor and conditions corrected asrequired.• Granular surfacing deteriorated. Recommend furtherinvestigation by licensed roofing contractor

Attic 2Page 16 Item: 2 Framing • There is a whitish and or darkened coloration that possibly

could be a fungal/mold growth. Conditions are generally aresult of excessive moisture at some point or inadequateventilation. Treating/remediation and correction moistureconditions will help prevent future occurrences. Testingwould need to be performed to determine the presence orabsence of Mold. Testing may include surface sampling andair quality testing.

KitchenPage 26 Item: 11 Electrical • No GFCI protection present on south wall right and left of

sink, strongly recommend conditions are investigated furtherand corrected as required by licensed electrical contractor.• GFCI outlet would not trip with tester on east wall GFCI triptest, strongly recommend conditions are investigated furtherand corrected as required by licensed electrical contractor.

LaundryPage 31 Item: 8 Window

Deficiencies• Broken tension bar on window frame. This is a "SafetyConcern". Tension bar holds window in open position.Window would not stay in the open position. Suggestrepairs/replacement as needed to ensure safety.

GaragePage 47 Item: 4 Garage Doors • Garage vehicle door sensors mounted higher than the

standard auto-reverse height. Maximum recommended height6 inches. Recommend adjustment as a safety precaution.

Foundation/CrawlspacesPage 56 Item: 9 Rodent • Indications of Rodent activity,some rodent droppings can

carry disease, recommend conditions are investigated furtherby licensed Pest Control Company.• Droppings present.

Page 67: FAIRA TRANSPARENCY REPORTS · 21621 SE 281st St, Maple Valley, WA 98038 March 20, 2018 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of

RW West Consultants, Inc. 21621 SE 281st St, Maple Valley, WA

Page 65 of 65

Page 57 Item: 10 Electrical • Low voltage wiring on the floor of the crawlspace.Recommend wiring is secured to the base of the framing as asafety precaution