OBJECTIVES

Identify characteristics of LPG vs. Natural Gas Identify standard extinguishing methods for

them Identify hazards associated with electricity

Page 3: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

CONTROL OF GAS UTILITIES

Natural Gas LPG - Liquefied Petroleum Gas

Page 4: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

NATURAL GAS

Mostly methane Nontoxic Classified as asphyxiant Odor - Butyl Mercaptin is added Explosive concentrations 4-14% Pressure ranges from 1/4 to 1000 psi Pressure is usually below 50 psi

Page 5: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

LIQUEFIED PETROLEUM GAS

Mainly propane Non-toxic Odor added 1.5 times heavier than air Explosive concentrations 1.5 to 10% Gas is shipped in cylinders and tanks

Page 6: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

INCIDENTS INVOLVING DISTRIBUTION SYSTEM

Most often caused by excavation Approach and stage from upwind side Evacuation is first concern Eliminate ignition sources in area Do not attempt to operate main valves

If burning, do not extinguish Exposures should be protected if necessary

Page 7: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

SERVICE METER

Flow stopped by turning the cutoff valve Use hoseline for protection

Page 8: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

SUPPRESSING CLASS C FIRES

Primary danger of electrical fires is the failure of FF’s to recognize the hazard.

Commercial and high rise buildings, power is necessary to operate elevators and /or air handling equipment so the entire building should not be unilaterally deenergized.

Once power has been shut down, fires may self-extinguish or become class A or B fires.

Page 9: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

BULK ELECTRICAL TRANSMISSION LINES An area equal to a span between poles

should be cleared on either side of the break. Transformers have coolant liquids that may

contain PCB’s. These liquids are flammable and may be carcinogenic.

Transformers at ground level - Dry Chem. Transformers above ground - Let burn

Page 10: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

WARNING

Stop the flow of electricity to the object involved before initiating fire suppression activities.

Consider all wires live until confirmed to be otherwise by the power company.

Page 11: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

UNDERGROUND LINES

Most common hazard is explosions. Accumulation of gases ignited by spark Keep public clear and don’t park apparatus

over a manhole. Do not enter except to attempt a rescue. Firefighting can be done from outside. Discharge Dry chemical or Carbon Dioxide

and replace cover.

Page 12: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

COMMERCIAL HIGH-VOLTAGE INSTALLATIONS

Water should not be used. Toxic chemicals, coolants smoke is a real

hazard. If rescue is required, search with clenched

fist or back of hand to prevent reflex actions of grabbing live equipment which may be contacted.

Page 13: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

ELECTRICAL POWER SHUTOFF

During structural firefighting ops., power should be turned off as soon as practical.

Firefighters do not pull electricity meter. Control power at panel box initially. Emergency Generators - pulling meter does not

shut off all power.

Page 14: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

ELECTRICAL EMERGENCIES

Never look directly at arcing electrical lines All wires treated as energized Do not cut electrical wires Use approved insulated tools Use care in raising/lowering ladders Proceed carefully where wires are down Mark downed line with appropriate tape,

inform command and on scene crews

Page 15: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

ELECTRICAL EMERGENCIES

Do not touch vehicles in contact with lines. Solid or straight streams must not be used. Special considerations for fences. If line is in

contact the entire fence becomes charged.

Page 16: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

REVIEW

Page 17: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

WHICH OF THE FOLLOWING STATEMENTS INVOLVING A PIPE BREAK IN A NATURAL GAS LINE IS NOT CORRECT?

1) First concern, evacuate around break and downwind.

2) If gas is burning, extinguish the flame.

3) FF’s should not operate main valves.

4) FF’s may stop flow of gas into a building by turning cutoff valve.

Page 18: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

2. IF THE GAS IS BURNING, FF’S SHOULD EXTINGUISH THE FLAME.

FIREFIGHTERS SHOULDN’T EXTINGUISH THE FLAME FROM LPG OR NATURAL GAS UNTIL THE SUPPLY HAS BEEN SHUT OFF.

Page 19: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

AT FIRES INVOLVING ELECTRICAL TRANSFORMERS AND BROKEN

TRANSMISSION LINES, FF’S SHOULD ________.

1) Allow transformers to burn themselves out.

2) Clear an area equal to the height of the pole.

3) Extinguish ground level transformers with dry chem if safe

4) Determine if the lines are energized or not

Page 20: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

4) DETERMINE IF THE LINES ARE ENERGIZED.

FIREFIGHTERS SHOULD NOT DETERMINE IF THE LINES ARE ENERGIZED OR NOT.

LEAVE THIS TO CLARK PUBLIC UTILITIES. SOME LINES MAY BECOME ENERGIZED

UPSTREAM FROM THE BREAK IF THEY ARE LAYING ACROSS POWER LINES.

Page 21: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

DURING STRUCTURAL FIRE FIGHTING OPS, IT IS DESIRABLE FOR ELECTRICAL POWER _______.

1) To remain on until FF’s are out of bldg.

2) Shut off as soon as fire personnel arrive.

3) Remain on until bldg. becomes damaged enough to interrupt electrical service

4) Shut off unless absolutely needed.

Page 22: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

4) SHUT OFF UNLESS ABSOLUTELY NEEDED

ELECTROCUTION IS A LIFE THREATENING HAZARD THAT SHOULD BE MITIGATED AS SOON AS POSSIBLE.

Page 23: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IDENTIFY THE FOLLOWING CHARACTERISTICS AS THOSE OF LPG, NATURAL GAS, OR

BOTH.

Page 24: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

HAS NO NATURAL ODOR.

Page 25: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

BOTH

Page 26: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS LIGHTER THAN AIR.

Page 27: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

NATURAL GAS

Page 28: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS NONTOXIC.

Page 29: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

BOTH

Page 30: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

HAS A DISTINCTIVE ODOR ADDED TO IT.

Page 31: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

BOTH

Page 32: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS EXPLOSIVE IN CONCENTRATIONS BETWEEN 4-14%.

Page 33: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

NATURAL GAS

Page 34: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS CLASSIFIED AS AN ASPHYXIANTE

Page 35: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

BOTH

Page 36: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS DISTRIBUTED FROM GAS WELLS TO ITS POINTS OF USAGE BY A

NATIONWIDE NETWORK OF SURFACE AND SUBSURFACE PIPES.

Page 37: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

NATURAL GAS

Page 38: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS ABOUT 1 1/2 TIMES AS HEAVY AS AIR.

Page 39: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

LPG

Page 40: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS EXPLOSIVE IN CONCENTRATIONS BETWEEN 1.5-10%.

Page 41: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

LPG

Page 42: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS STORED IN TANKS AND CYLINDERS NEAR ITS POINT OF USAGE.

Page 43: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

LPG

Page 44: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

IS USED PRIMARILY AS A FUEL GAS IN CAMPERS, MOBILE HOMES, AND RURAL

HOMES.

Page 45: F IRE C ONTROL BY T ODD I REMONGER Developed by Todd Iremonger, 2001 Adapted by CCTD, 2012

LPG