EXZHELLENT RZ1F3Z1-K (AS) AlPOWER RAILWAY INDOOR INFRASTRUCTURE

CUSTOMER SERVICETEL.:+34 932 279 700FAX : +34 932 279 719www.generalcable.es

EXZHELLENT RZ1F3Z1-K AL (AS )

Page 2: EXZHELLENT RZ1F3Z1-K (AS) Al POWER RAILWAY …grandvoltage.ro/download_file/brosuri/GC_Exzhellent Flexalum... · (1) Current ratings according to UNE 20460-5-523 table A,52-1 bis,

RZ1F3Z1-K (AS) AlRated voltage: 0,6/1 (1,2) kVArmoured, Halogen-Free & Fire Retardant

1.- CONDUCTOR:Aluminium, class 2 with flexible wires (-K).Sector-shaped for 50 mm2 and higher cross-sections.

2.- INSULATION:Halogen-free cross-linked polyethylene, XLPE (R).Core identification by colours.

3.- INNER COVERINGHalogen free thermoplastic polyolefin (Z1).

4.- ARMOURCorrugated tinned steel tape for multi core cables (F3) or aluminiumfor single core cables (FA3).

5.- OUTER SHEATH:Halogen free thermoplastic polyolefin type ST7 according to IEC 60502-1 (Z1).

Low voltage power cables specially designed for powerelectric circuits in indoor railway infrastructure such astunnels, stations, technical buildings and generally inpublic zones or zones where it is possible for people tostay. With special fire performance such as fire retardancy,halogen-free and low emission of smoke and fumes.

The cables are armoured with special corrugated steelarmour, which provides the cable mechanical safetywater-tightness and rodent-proofness, and betterhandleability.

The unique SECTORFLEX® flexible sector-shaped conductor design allows significantly easier installationwith improved flexibility and handleability due the lower cable diameter and weight, while providing thesame electrical performance and allowing the use of the same conventional terminals and accessoriesas circular conductors.

Minimum operational temperature: -40 ºC. Maximum rated conductor temperature in normal operation: 90 ºC

1

2

34

5

FLAMEHALOGENS WATER TIGHTREINFORCED RODENT-PROOFGASESSMOKE FLEXIBLE SECTORFLEX -40 ºCFIRE

STANDARS & FEATURES:

DESIGN CHARACTERISTICS:

APPLICATIONS & MAIN FEATURES:

Flameretardant

IEC 60332-1-2

Halogen-freeIEC 60754-1

Low smoke &fumes

IEC 61034-2

Low acidity &corrosivity

IEC 60754-2

Armoured Water-tight Rodent proof FlexibleIEC 60228

Sector-shapedconductor

SECTORFLEX

Low temp.- 40 ºC

Fire retardantIEC 60332-3-24

INDOOR

Page 3: EXZHELLENT RZ1F3Z1-K (AS) Al POWER RAILWAY …grandvoltage.ro/download_file/brosuri/GC_Exzhellent Flexalum... · (1) Current ratings according to UNE 20460-5-523 table A,52-1 bis,

Code Crosssection

mm2

Diameterunder

armour

mm

Outerdiameter

mm

Weight

kg/km

Minimumbendingradius

mm

Maximumcurrent ratingAir 40 ºC (1)

Ohm/km

Drop voltage a.c.three phase system

cos phi = 0.8

V/A.km727321172732127273213727321472732157273216727321772732187273219727322072732217273311727331272733137273314727331572733167273317727331872733197273320727341172734127273413727341472734157273416727341772734187273419727342072735117273512727351372735147273515727351672735177273518

2x162x252x352x502x702x952x1202x1502x1852x2402x3003x163x253x353x503x703x953x1203x1503x1853x2404x164x254x354x504x704x954x1204x1504x1854x2405x165x255x355x505x705x955x1205x150

22,425,327,528,933,436,238,540,645,649,254,523,626,728,834,037,640,943,746,452,357,225,428,931,436,540,644,347,450,757,563,127,631,534,442,447,452,156,160,4

16,819,721,923,326,429,231,533,638,642,046,918,021,123,227,030,633,936,739,445,349,819,823,325,829,533,637,340,443,550,155,322,025,928,635,440,445,148,953,0

670865

1.0251.1251.5051.8052.0702.3302.8553.3954.145735955

1.1251.4101.7452.1052.4352.7403.3404.095840

1.1051.3201.7152.1502.6253.0503.5204.3505.395980

1.3101.5852.3502.9853.6854.3455.070

225255275290335365385410460495545240270290340380410440465525575255290315365410445475510575635280315345425475525565605

8394117145187230269312359429496668410412716219722826430135566841041271621972282643013556684104127162197228264

7798118139172204232263294340384648199118145173196221249287648199118145173196221249287648199118145173196221

3,4712,2111,6191,2150,8620,6420,5230,4400,3650,2960,2513,4712,2111,6191,2150,8620,6420,5230,4400,3650,2963,4712,2111,6191,2150,8620,6420,5230,4400,3650,2963,4712,2111,6191,2150,8620,6420,5230,440

0,238 0,241 0,236 0,233 0,230 0,226 0,226 0,228 0,227 0,225 0,223 0,238 0,241 0,236 0,233 0,230 0,226 0,226 0,228 0,227 0,225 0,238 0,241 0,236 0,233 0,230 0,226 0,226 0,228 0,227 0,225 0,238 0,241 0,236 0,233 0,230 0,226 0,226 0,228

Inductance

mH/km

Maximumcurrent ratingDirectly buried

25 ºCV/A.km

Ed

ition: Novem

ber 2009

(1) Current ratings according to UNE 20460-5-523 table A,52-1 bis, method of installation F for single-core cables and E for multi-core cables

(*) Other cross-sections available on request

PHYSICAL CHARACTERISTICS:

Page 4: EXZHELLENT RZ1F3Z1-K (AS) Al POWER RAILWAY …grandvoltage.ro/download_file/brosuri/GC_Exzhellent Flexalum... · (1) Current ratings according to UNE 20460-5-523 table A,52-1 bis,

CUSTOMER SERVICETEL.:+34 932 279 700FAX : +34 932 279 719www.generalcable.es

NorwayTel.: +47 [email protected]

FranceTel.: +33 (0) 1 60 57 30 [email protected]

United KingdomTel.: +44 1244 893 [email protected]

ItalyTel.:+39 02 660 [email protected]

PortugalTel.: +351 219 678 [email protected]

GermanyTel.: +49 4731 82 [email protected]

Abu Dhabi (UAE)Tel.: + 971 -2- [email protected]

RussiaTel.: +7 495 617 [email protected]

Spain (headquaters)Tel.: 93 227 97 [email protected]

AlgerTel.: +213 21676174/[email protected]

BiskraTel.: +213 33754321/[email protected]

EgyptTel.: +2017 38 5555 [email protected]