UK/0126/0119
MI-005
Issue date: Valid until
18 December 2018 16 January 2022
Marek Bokota Technical Manager For and on behalf of the Head of Technical Services
0135
NMO I Stanton Avenue I Teddington I TW11 OJZ I United Kingdom Tel +44 (0) 20 8943 7272 I Fax +44 (0) 20 8943 7270 I Web www.gov.uk/government/organisations/regulatory-delivery NMO is part of the Regulatory Delivery directorate within the Department for Business, Energy & Industrial Strategy
EU-type examination certificate UK/0126/0119 Revision 3
Issued by:
NMO Notified Body Number 0126
In accordance with the requirements of the Measuring Instruments Regulations 2016 (S.I. 2016 No. 1153) which implement, in the United Kingdom, Council Directive 2014/32/EU, this EU-type examination certificate has been issued to:
Dem. G. Spyrides S.A. 24 Athinon Avenue 10441 Athens Greece
In respect of a LPG dispenser instrument designated the M5200 and having the following characteristics:
Accuracy class: 1.0
The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.
This revision replaces previous versions of the certificate.
2/17
Descriptive Annex 1 INTRODUCTION The M5200 LPG dispenser is for use in attended or unattended mode. The housing comprises a hydraulics enclosure with an electronics enclosure above it. Hose connections are made at the hydraulic housing with an example arrangement shown in Figure 1. 2 CHARACTERISTICS
Accuracy Class 1.0
Mechanical Environment Class M1
Electromagnetic Environment Class E1
Vmin 5 litres (often determined by national re-verification practices)
Temperature Range Liquid -10 °C to 50 °C
Temperature Range Ambient -25 °C to 55 °C
3 CONSTRUCTION 3.1 Prime Components and Characteristics 3.1.1 The dispenser is constructed from the following prime components:
Table 1 Prime Component Summary
Manufacturer Type Evaluation Certificate
Meters
Yenen YGM TC7300
2A (Mühendislik A.Ş.) PRIMA SK 12 – 001 ME
Electronic Calculator
Dem G Spyrides S.A. AK6 GB-1427
Self-service devices
- - -
3.2 Optional Components and Arrangements 3.2.1 Optional Chassis Construction 3.2.1.1 The electronics enclosure facia may be constructed of steel, aluminium, or plastic, or a combination of these materials. 3.2.1.2 The dispenser may be combined with one or more liquids other than water dispensers, which may also share the calculating device.
3/17
3.3 Options not critical to metrology 3.3.1 The following items may be included within the hydraulic circuits, typical examples of both single and double nozzle configurations are shown in Figures 2, 3 and 6 respectively:
• Check Valves
• Safety Relief Valves
• Differential Valves
• Gas Separator
• Pressure Gauge/Manometer
• Excess Flow Valves
• Filters
• Purge Valves 3.3.2 The following items may be included within the electronics housing without being included in component evaluation certificates
• Any electronics not associated with the sales transaction and not connected to circuits of the calculator, and which will not impact the EMC characteristics of the enclosure.
4 APPROVAL CONDITIONS The certificate is issued subject to the following conditions: 4.1 Markings 4.1.1 Markings are in accordance with the WELMEC Guide 10.5 Issue 1. An example is shown in Figure 4. Initial verification labels including the CE mark and supplementary metrology mark are added to this nameplate; but may be removed at subsequent field verifications. The height of the CE mark and the rectangle containing the letter “M” and year code are greater than 5mm.
4.1.2 The markings and inscriptions shall fulfil the requirements of Article 8, Article 21, Article 22 and Point 9 of Annex I of Directive 2014/32/EU. The markings shall include the manufacturer’s postal address.
4.2 Data Sheet 4.2.1 The datasheet format is in accordance with the WELMEC Guide 10.5 Issue 1. An example is shown in Figure 5. 4.3 Displays and Legends 4.3.1 Displays and legends are configured to meet the requirements of the country of installation. The text associated with the volume and price is greater than 10mm high. The text associated with unit price(s) is greater than 4mm high. 4.3.2 Text is included on or near the primary display to indicate the minimum delivery for the dispenser.
4/17
5 LOCATION OF SEALS 5.1 Securing is detailed in the Evaluation Certificates for the individual components. 5.2 Components may additionally be sealed to the dispenser frame, or alternatively, may be specifically listed by serial number on a datasheet which remains with the dispenser in the calculator enclosure. 6 SUPPORTING DOCUMENTATION 6.1 Documentation File Trim File TS0901/0017/4 7 ALTERNATIVES 7.1 Having alternative software version(s) and checksum(s) for the Electronic Calculator AK6 described in certificate GB-1427.
i) Version 5.11 Checksum 0x6C95 ii) Version 5.12 Checksum 0x90BA iii) Version 5.14 Checksum 0x199E iv) Version 5.15 Checksum 0x48CE v) Version 5.20 Checksum 0x2E53 vi) Version 5.22 Checksum 0x4512
8 ILLUSTRATIONS Figure 1 Typical arrangements Figure 2 Single Nozzle Configuration (YENEN hydraulics – YGM meter) Figure 3 Double Nozzle Configuration (YENEN hydraulics – YGM meter) Figure 4 Nameplate – typical arrangements, Figure 5 Datasheet Figure 6 Double Nozzle Configuration (2A hydraulics – PRIMA meter) Figure 7 Sealing measures 9 CERTIFICATE HISTORY
ISSUE NO. DATE DESCRIPTION
UK/0126/0119 17 January 2012 Type examination certificate first issued.
UK/0126/0119 Revision 1
22 May 2012 Table 1 - Prima Meter added.
UK/0126/0119 Revision 2
11 January 2018 References to 2004/22/EC replaced with 2014/32/EU.
Postal address added to section 4.1.2.
Figure 7 added.
UK/0126/0119 Revision 3
18 December 2018 Section 7.1 added.
Section 3.3 renumbered to 3.2
Section 3.4 renumbered to 3.3
5/17
Figure 1 Typical arrangement
6/17
Item number Description Quantity
1 Flow meter outlet (bottom) 1
2 1” DIN check valve 1
3 Gas separator 1
4 ¾” PN valve 3
5 Filter with ¼” purge screw 1
6 Safety relief valve 1
7 Differential valve 1
8 Pressure gauge 1
9 2-Way dual flow solenoid valve 1
10 ¾” Excess flow valve 1
Figure 2 Single Nozzle Configuration (YENEN hydraulics – YGM Meter)
7/17
Item number
Description Quantity Item number
Description Quantity
1 Flow meter 2 18 Safety relief valve 2
2 Pulser mounting bracket 2 19 ¼” Reverse connector
4
3 Pulser 2 20 3-Way solenoid valve
2
4 1” check valve with DIN flange 2 21 ¾” Special fittings 2
5 Gas separator (double) 1 22 Differential valve complete (Right)
1
6 Bolt M12x55 8 23 Manometer 63x40 bar
2
7 M12 Nut 8 24 ¼” Flat seal 5
8 ¾” PN40 valve 1 25 ¼” – ¾” Reduction 2
9 ¾” NPT – ¾” NPT nipple 1 26 ¾” T with angle 1
10 Filter 1 27 ¼” Nipple 1
11 ¼” Purge valve 1 28 ¼” Nozzle connector 1
12 ¼” Elbow 1 29 2-Way solenoid valve body
2
13 ¼” Check valve 2 30 ¾” NPT thread elbow
1
14 ¼” NPT Elbow 14 31 ¾” Cross 1
15 Pipe connection Nut 8 39 32 Differential valve complete (Left)
1
16 ¼” T with ring 4 33 Coil 230V (AC) 4
17 8mm hydraulic pipe 4m
Figure 3 Double Nozzle Configuration (YENEN hydraulics – YGM Meter)
8/17
Figure 4 Nameplate – typical arrangements
DEM. G. SPYRIDES S.A.
24 ATHINON AV.,
ATHENS 10441, GREECE
LPG Dispenser Type M5200
II 2 G IIA T3
Ambient Temp.: -25 to +55°C
EN 14678-1
0359
12
M 0126
1
Q min.
L/min
Homologation No:
Measurement Unit: Litre
Ex Certificate No:
ITS XX ATEX XXXX
Liquid Temp.: -10 to +50°C
Accuracy Class: 1.0
Mechanical Class: M1
Electromagnetic Environment: E1
Q max.
L/min
2
1
Model / Year:
Serial No:
1
Design
Pressure
bar
25
Max. Working
Pressure
bar
18
Working
Pressure
bar
9 - 11 5 50
Nozzle
No.
FRONT
2
BACK
Nature of Liquid: Autogas, LPG
2
W&M Approval No:
UK/0126/0119
9/17
Figure 5 Datasheet
10/17
1
2
5
6
7 8 9 11 10
12 14
11
13 3
15 16
11/17
Item number Description Quantity
1 Frame 1
2 Flowmeter (PRIMA) 2
3 Pressure gauge 1
4 Pulser 2
5 Solenoid valve 2
6 Differential valve 2
7 ¾” Ball valve 3
8 Maintenance port 1
9 Vapour return line 1
10 ATC 2
11 Liquid phase line 2
12 Check valve 2
13 Safety relief valve 1
14 Gas separator 1
15 Filter 1
16 ¼” Purge valve 1
Figure 6 Double Nozzle Configuration (2A hydraulics – PRIMA Meter)
12/17
Sealing AK6, checkSum 857C, version F4.10 / checkSum 0xE7FD, version F4.15 / checkSum 0x6C95, version 5.11 / checkSum 0x90BA, version 5.12
Sealing PRIMA Flowmeter Upper Cover
13/17
Sealing PRIMA Flowmeter Side Covers & Adjuster Cover
Sealing Air Separator
14/17
Sealing Differential Valve (option 1)
Sealing Differential Valve (option 2)
15/17
Sealing P100 Pulser
Sealing Ball Valve (option 1)
16/17
Sealing Ball Valve (option 2)
Sealing Marking Plate
17/17
Sealing Head Enclosure
Figure 7 Sealing measures
© Crown copyright 2018 NMO Regulatory Delivery directorate Department for Business, Energy & Industrial Strategy This material may be freely reproduced except for sale