A W O R L D O F D IF F E R E N C E F O R R E A L W O R L D C O N D I T I O N S Wate rproofing Systems 800-882-1896 • www.eproserv.com Excellent Strength and Durability – The result of the unique field installed composite design. Exceptional Chemical Resistance – The HDPE films are very resistant to most contaminates including VOCs. Seamless System – The fluid applied component makes the transition details and field barrier a monolithic installation. Fully Bonded to Slab – The geo-textile surface of the barrier mechanically interlocks with the concrete slab to form a permanent bond between the barrier and slab. Redundant Protection – Multiple waterproofing and gas vapor barriers as well as protection courses. System Description System III MB is a field installed composite waterproofing and gas vapor barrier that is comprised of a water-based polymer modified asphalt (PMA) membrane sandwiched between two HDPE and polypropylene fabric laminate sheets which provides the durability and chemical resistance of HDPE with the constructability and installation efficiencies of a PMA. (See below for special designs for water table conditions.) System Components Ecoshield-P (Base Course) – An HDPE film laminated with a nonwoven polypropylene fabric geo-membrane. Ecoline-S (Middle Course) – A spray or fluid applied, water based polymer modified asphalt membrane. Ecoshield-PP (Top Course) – Same as Ecoshield-P except with micro-perforations. System Components (Water Table Design) Ecoshield-PB -(Replaces Ecoshield-PP) - A geocomposite membrane comprised of polypropylene fabric and bentonite granules laminated to an HDPE sheet to provide self sealing characteristics and puncture resistance. Additional Information Specifications – Reference “Specification Beneath Slab Moisture Barrier” Detail Drawings – Reference all “MB” labeled Details Installation Guidelines – Reference “Moisture Barrier Installation” and “Repair Procedures – Moisture Barrier” Product Information –Reference “Ecoline-S”, “Ecoline- R”, “Ecoshield-P”, "Beneath Slab Gas Vapor Barrier" product brochures epro • System III MB Moisture / Gas Barrier Excellent Strength and Durability • Exceptional Chemical Resistance • Seamless System • Fully Bonded to Slab • Redundant Protection Patent Pending rev. sys3-mb_042111

Epro - System III MB

Embed Size (px)

DESCRIPTION

Moisture & Gas Barrier

Citation preview

Page 1: Epro - System III MB

A

WORLD OF DIFFERENCE

FO

RREAL WORLD CONDIT

ION

S

Waterproof i ng Systems

800-882-1896 • www.eproserv.com

Excellent Strength and Durability – The result of the unique field installed composite design.

Exceptional Chemical Resistance – The HDPE films are very resistant to most contaminates including VOCs.

Seamless System – The fluid applied component makes the transition details and field barrier a monolithic installation.

Fully Bonded to Slab – The geo-textile surface of the barrier mechanically interlocks with the concrete slab to form a permanent bond between the barrier and slab.

Redundant Protection – Multiple waterproofing and gas vapor barriers as well as protection courses.

System DescriptionSystem III MB is a field installed composite waterproofing and gas vapor barrier that is comprised of a water-based polymer modified asphalt (PMA) membrane sandwiched between two HDPE and polypropylene fabric laminate sheets which provides the durability and chemical resistance of HDPE with the constructability and installation efficiencies of a PMA. (See below for special designs for water table conditions.)

System Components

Ecoshield-P (Base Course) – An HDPE film laminated with a nonwoven polypropylene fabric geo-membrane. Ecoline-S (Middle Course) – A spray or fluid applied, water based polymer modified asphalt membrane. Ecoshield-PP (Top Course) – Same as Ecoshield-P except with micro-perforations.

System Components (Water Table Design)Ecoshield-PB -(Replaces Ecoshield-PP) - A geocomposite membrane comprised of polypropylene fabric and bentonite granules laminated to an HDPE sheet to provide self sealing characteristics and puncture resistance. Additional Information

Specifications – Reference “Specification Beneath Slab Moisture Barrier”Detail Drawings – Reference all “MB” labeled Details Installation Guidelines – Reference “Moisture Barrier Installation” and “Repair Procedures – Moisture Barrier” Product Information –Reference “Ecoline-S”, “Ecoline-R”, “Ecoshield-P”, "Beneath Slab Gas Vapor Barrier" product brochures

epro • System III MB Moisture / Gas BarrierExcellent Strength and Durability • Exceptional Chemical Resistance • Seamless System • Fully Bonded to Slab • Redundant Protection

Patent Pending

rev. sys3-mb_042111

Page 2: Epro - System III MB

Tensile Strength* .........................Elongation* ..................................Adhesion to Concrete*** ..............Puncture Resistance ....................Hydrostatic Pressure ...................

Soil Burial* ...................................Weight change .....................Tensile Strength ...................Elongation ............................

Heat Aging* .................................Tensile Strength ..................Elongation ..........................

Environmental Stress Cracking* ..Failure ................................

Oil Resistance* ..........................

Weight change ............................Tensile Strength .................Elongation ..........................

Methane Transmission* ..............

epro • System III MB - Moisture / Gas Barrier

Epro Below Slab Water / Gas Barrier Composite System Testing

Composition HDPE film and polypropylene fabric laminate and polymer modified asphalt and HDPE film and polypropylene fabric laminate. ( Ecoshield-P / Ecoline-S / Ecoshield-PP )

Chemical Permeation** ....

Chlorinated SolventPerchloroethylene .......Trichloroethylene ........

Aromatic HydrocarbonBenzene ....................

Chemical Resistance** ......Chlorinated Solvents ..PerchloroethyleneWeight ........................ Tensile Strength .........TricholorethyleneWeight ........................Tensile Strength .........

Aromatic HydrocarbonBenzeneWeight ........................ Tensile Strength .........

GasesHydrogen SulfideWeight ........................ Tensile Strength .........

ASTM D-412 .....ASTM D-412 .....ASTM C-836 ....ASTM D-1709 ...ASTM D-5385 ...

ASTM D-4068See Note 1 ........See Note 1 ........See Note 1 ........

ASTM D-4068See Note 1 .......See Note 1 .......

ASTM D-1693See Note 2 ........

ASTM D-543 & ASTM D-412See Note 1 .......See Note 1 .......See Note 1 .......

ASTM D-1434See Note 3 .......

662 psi45%27 lbf/in310.9 lbs369.5 ft.

1.2% .........9.89% .......2.2% .........

8.6% .........8.9% .........

620 hrs. ....

7.6% .........1.1% .........4.4% .........

3.70xE-15..

passedpassedpassed

passedpassed

passed

passedpassedpassed

passed

ASTM F-739

............................

............................

............................

ASTM D-543ASTM D-882 Mod.

.............................

.............................

.............................

.............................

.............................

.............................

.............................

.............................

Perm RateUg/cm2

69.4 ..........89.8 ..........

59.3 ..........

Net change

4.1%6.5%

5.4%6.0%

4.1%4.4%

0.6%0.8%

Perm Rateml/day

0.00080.0012

0.0013

* Tests performed by SGS / US Testing** Tests performed by TRI Environmental*** Tests performed by Momentum Technologies

Note 1: LA requires less than 10%Note 2: LA requires over 500 hrs.Note 3: LA requires less than 3 ml per day

(Less 10% pass)