Note : SP = Standard Pack Quantity, g = Weight in Grams, F-T = Fusion Time in Seconds, C-T = Cooling Time in Minutes PE 100 Black 4 mm Pin Terminal PE 100 Black 4.7mm Pin Terminal Electrofusion Coupler for Gas / Water - SDR11 (ISO S5) PT KARO GRAHA ABADI Crystal Shophouse CRL No 7 Jl Gading Golf Boulevard Gading Serpong - Indonesia, 15810 TEL.: +62 21 5421 3636 MAIL : [email protected] WEBSITE : www.karograha.com Common Applications: Pipe to pipe connection during laying Pipe connections in areas difficult to access, in narrow trenches Repairing localised damages on pipes, connections of transition fittings, pipe stub ends etc Pipe Connections with spigot end fittings Reinforcements of squeezed or kinked portions of permanently laid down (immovable) pipes Advantages : Standard Operating Voltage - 40 V Same fusion time for various SDR and PN rated pipes Higher penetration of pipe in the fittings enables proper alignment Optimal fusion and cold zone for a strong and sturdy joint Auto Temperature compensation for ambient conditions -5°C to + 40°C Clearance-Fit for ease of installation 20-125mm coupler with knock down stopper & 140-315mm couplers are with removable stopper Pop-Up fusion indicators to indicate fusion process performance Permanent Batch Indicator, Fusion Time, Cooling Time, Raw Material Grade and SDR marking Each fitting individually packed in PE bag to protect against contamination and oxidation Each fitting with water-proof bar code to automatically feed fusion data to the Control-box for fusion process Kimplas Electrofusion Couplers, manufactured in PE100 (Black) grade are Standard SDR 11 rated (PN 16). Kimplas Electrofusion fittings are suitable for permanently connecting MDPE 80 and PE 100 pipes, both in straight as well as coil form. Installation : Joint preparation must be done as specified in the installation instructions. Pipe outside surface must be scraped to remove oxidized layer. Before fusing, pipe ends and inside of the fittings must be cleaned to remove dirt and contamination. Complete Installation Manual may be downloaded. Standards: PE Pipe Compatibility : ISO:4427, ISO:4437, EN:1555-2, EN: 12201-2, IS: 4984, DIN:8074 Complies with EN1555- Part 3 for Gas, EN12201- Part 3 for water For details about our other products and specifications please refer the corporate website Disclamer : Kimplas reserve the right to modify product without prior notice, as part of its continual improvement programme. Whilst every effort is taken to ensure the accuracy of information contained in the data Sheet, Kimplas accepts no liability for matters arising as a result of errors or omissions. GW-Rev02/July17 GIS/PL-4:2014 KM 518050 TM 20 25 32 40 50 55 63 75 90 110 44 53 68 67 133 117 133 221 496 799 31 36 44 53 65 69 81 91 113 138 70 70 75 75 90 85 100 100 133 152 22 28 42 52 55 40 70 80 140 160 4 4 4 7 7 7 7 7 15 15 C20BKB C25BKB C32BKB C40BKB C50BKB C55BKB C63BKB C75BKB C90BKB C110BKB 250 175 150 125 60 50 35 35 14 11 140 160 180 200 225 250 280 315 240 380 400 480 690 840 650 840 20 20 20 30 30 40 40 40 170 193 215 246 277 292 342 386 165 180 190 183 212 212 220 274 1217 1585 2000 2270 3500 4500 5800 8030 C140BKB C160BKB C180BKB C200BKB C225BKBN C250BKBN C280BKBN C315BKBN 7 12 9 6 4 4 2 2 C20BKA C25BKA C32BKA C40BKA C50BKA C55BKA C63BKA C75BKA C90BKA C110BKA C140BKA C160BKA C180BKA C200BKA C225BKAN C250BKAN C280BKAN C315BKAN 125 885 152 167 220 15 C125BKF 7 C125BKAF

Electrofusion Coupler for Gas / Water - SDR11 (ISO S5) · 2019. 4. 23. · • PE Pipe Compatibility : ISO:4427, ISO:4437, EN:1555-2, EN: 12201-2, IS: 4984, DIN:8074 • Complies

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Electrofusion Coupler for Gas / Water - SDR11 (ISO S5) · 2019. 4. 23. · • PE Pipe Compatibility : ISO:4427, ISO:4437, EN:1555-2, EN: 12201-2, IS: 4984, DIN:8074 • Complies

Note : SP = Standard Pack Quantity, g = Weight in Grams, F-T = Fusion Time in Seconds, C-T = Cooling Time in Minutes

4mm Pin Terminal 4.7mm Pin TerminalPE 100 Black

4 mm Pin TerminalPE 100 Black

4.7mm Pin Terminal

Electrofusion Coupler for Gas / Water - SDR11 (ISO S5)

PT KARO GRAHA ABADI

Crystal Shophouse CRL No 7Jl Gading Golf Boulevard

Gading Serpong - Indonesia, 15810TEL.: +62 21 5421 3636

MAIL : [email protected] : www.karograha.com

Common Applications:

Pipe to pipe connection during laying

Pipe connections in areas difficult to access, in narrow trenches

Repairing localised damages on pipes, connections of transition

fittings, pipe stub ends etc

Pipe Connections with spigot end fittings

Reinforcements of squeezed or kinked portions of permanently

laid down (immovable) pipes

Advantages :

• Standard Operating Voltage - 40 V

• Same fusion time for various SDR and PN rated pipes

• Higher penetration of pipe in the fittings enables proper alignment

• Optimal fusion and cold zone for a strong and sturdy joint

• Auto Temperature compensation for ambient conditions -5°C to +

40°C

• Clearance-Fit for ease of installation 20-125mm coupler with

knock down stopper & 140-315mm couplers are with removable

stopper

• Pop-Up fusion indicators to indicate fusion process performance

• Permanent Batch Indicator, Fusion Time, Cooling Time, Raw

Material Grade and SDR marking

• Each fitting individually packed in PE bag to protect against

contamination and oxidation

• Each fitting with water-proof bar code to automatically feed fusion

data to the Control-box for fusion process

Kimplas Electrofusion Couplers, manufactured in PE100 (Black) grade are Standard SDR 11 rated (PN 16). Kimplas Electrofusion fittings are

suitable for permanently connecting MDPE 80 and PE 100 pipes, both in straight as well as coil form.

Installation :

Joint preparation must be done as specified in the installation

instructions. Pipe outside surface must be scraped to remove oxidized

layer. Before fusing, pipe ends and inside of the fittings must be

cleaned to remove dirt and contamination. Complete Installation

Manual may be downloaded.

Standards:

• PE Pipe Compatibility : ISO:4427, ISO:4437, EN:1555-2, EN:

12201-2, IS: 4984, DIN:8074

• Complies with EN1555- Part 3 for Gas, EN12201- Part 3 for water

For details about our other products and specifications please refer the corporate websiteDisclamer : Kimplas reserve the right to modify product without prior notice, as part of its continual improvement programme. Whilst every effort is taken to

ensure the accuracy of information contained in the data Sheet, Kimplas accepts no liability for matters arising as a result of errors or omissions.

GW-Rev

02/July�17

GIS/PL-4:2014KM 518050

TM

20

25

32

40

50

55

63

75

90

110

44

53

68

67

133

117

133

221

496

799

31

36

44

53

65

69

81

91

113

138

70

70

75

75

90

85

100

100

133

152

22

28

42

52

55

40

70

80

140

160

4

4

4

7

7

7

7

7

15

15

C20BKB

C25BKB

C32BKB

C40BKB

C50BKB

C55BKB

C63BKB

C75BKB

C90BKB

C110BKB

250

175

150

125

60

50

35

35

14

11

140

160

180

200

225

250

280

315

240

380

400

480

690

840

650

840

20

20

20

30

30

40

40

40

170

193

215

246

277

292

342

386

165

180

190

183

212

212

220

274

1217

1585

2000

2270

3500

4500

5800

8030

C140BKB

C160BKB

C180BKB

C200BKB

C225BKBN

C250BKBN

C280BKBN

C315BKBN

7

12

9

6

4

4

2

2

C20BKA

C25BKA

C32BKA

C40BKA

C50BKA

C55BKA

C63BKA

C75BKA

C90BKA

C110BKA

C140BKA

C160BKA

C180BKA

C200BKA

C225BKAN

C250BKAN

C280BKAN

C315BKAN

125 885 152 167 220 15C125BKF 7C125BKAF