4
LUMINAIRE SPECIFICATION Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previous printed or electronic versions. OUTLINE LED Recessed Linear Perimeter Slot System Project Name Type Catalog Number Date Sample Catalog #: EVL-30-24’-FL-120-1C-W EVL- Edge Evo- lution Outline EVLS- Edge Evolution Out- line Shallow YEAR LED WARRANTY CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Extruded alumi- num module with reflector and lens for perfect perimeter illumination. FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish on exposed trim. Driver cover to be painted standard white when custom color specified. Consult factory for custom colors. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. MOUNTING Edge Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF for individual and continuous runs (runs designed to fall on-grid). Consult factory for detailed installation instructions. ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥91, 30K, 35K, and 40K is CRI≥83. Minimum lifetime greater than 60,000 hours. WARRANTY Edge Evolutuion LED offered with a 5-year limited warranty. Covers LED, driver and fixture. COLOR/LUMENS EVL_- ____- ___’- ___- ___- __- ____ __- HOUSING LENGTH MOUNTING 1 VOLTAGE CIRCUITING FINISH OPTIONS Matte White Metallic Silver (rails only) 9 Textured Black (rails only) 9 Graphite (rails only) 9 Bronze (rails only) 9 Custom Color (rails only) 9 W- S- BL- GR- BR- CC- Inaccessible Ceiling G1- G9- GS- GB- 1” (25.4mm) Ceiling Grid 9/16” (14.3mm) Ceiling Grid Screw Slot Ceiling Grid 9/16” (14.3mm) Ceiling Grid with Bevel Trim Standard 1/2” (12.7mm Flange Spackle Flange Flangeless 4 FL- SF- NF- Acoustical Grid Ceiling 120- 277- 347- UNV- 120 V 277 V 347 V UNV (120-277) 1C- 1D- 1B- 1E- Single Circuit Single Circuit Dimming 5 Single Circuit with Battery Pack 5, 6,11 Single Circuit with Emergency Circuit 11 2- 3- 4- 6- 8- 2’, 23” (584.2mm) fixture 2 3’, 35” (889mm) fixture 2 4’, 47” (1,193.8mm) fixture 2 6’, 71” (1,893.4mm) fixture 2 8’, 95” (2,413mm) fixture 2 Individual Units 2 Continuous Runs 3 xx’- Specify row length to 1’ (304.8mm) increments 1 See back page for mounting detail. 2 Individual units shipped with end plates uninstalled. 3 Continuous runs made up of both even and odd length fixtures. Designed to fall on-grid. 4 NF to be utilized for metal pan / millwork ceiling. 5 Some Edge configurations will not accommodate all electrical options. Consult factory. 6 Integral battery packs with remote test switch are provided with 1B option. Available in 4’ or longer lengths. 7 See back page for corner details. 8 End Filler option used for fitting fixture into odd lengths. Filler is non-illuminated. Left and right end filler provided whe EF specified. 9 Custom Color will be on fixture rails only. 10 Osram/Sylvania Color Changing RGB LED and components are for accent or decorative lighting and does not provide room illumination. See back page for more information. 11 Submittal drawings required. 12 Low Glare Reflector (LGR) required on any layout with inside corner. LGR softens glare and changes polar cuvre and does effect lumen out put and efficacy, see back page for photometry. 13 Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago plenum, and GLR. 30- 30HO- 30VHO- 27- 27HO- 27VHO- 30K Color Temperature Lumen Options 27K Color Temperature Lumen Options 40K Color Temperature Lumen Options 40- 40HO- 40VHO- 35- 35HO- 35VHO- 35K, 209 lumens/ft (4.0 watts/ft) 35K, 398 lumens/ft (6.0 watts/ft) 35K, 514 lumens/ft (8.0 watts/ft) 40K, 214 lumens/ft (4.0 watts/ft) 40K, 409 lumens/ft (6.0 watts/ft) 40K, 527 lumens/ft (8.0 watts/ft) 30K, 200 lumens/ft (4.0 watts/ft) 30K, 381 lumens/ft (6.0 watts/ft) 30K, 492 lumens/ft (8.0 watts/ft) 27K, 164 lumens/ft (4.0 watts/ft) 27K, 313 lumens/ft (6.0 watts/ft) 27K, 404 lumens/ft (8.0 watts/ft) 35K Color Temperature Lumen Options EDGE E V O L U T I O N Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® March 2016 Quick Ship 13 Chicago Plenum Internal Fast blow fuse Low Glare Reflector 12 90˚ Inside Corner 7,11 90˚ Outside Corner 7,11 45˚ Inside Corner 7,11 45˚ Outside Corner 7,11 End Filler 8 Step Switching QS- CP- GLR- LGR- C90I- C90O- C45I- C45O- EF- SW- RGB LED 10 RGBX- RGB LED with DMX Controller Shallow (EVLS) Standard (EVL) 4-1/2” (114.3mm) 4-1/2” (114.3mm) 5-1/4” (133.4mm) 4-1/4” (107.9mm) CL_____- CW____- Specify color temp. and lumens/ft. (i.e. CL35300) Specify color temp. and wattage/ft. (i.e. CW407) (Specify lumens/watts between standard offering listed above. Lumens are specified per color temp.) Custom Output

EDGE - Villa Lighting Supply, Inc....13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EDGE - Villa Lighting Supply, Inc....13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago

L U M I N A I R E S P E C I F I C A T I O N

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previous printed or electronic versions.

OUTLINELED Recessed Linear Perimeter Slot System

Project Name

TypeCatalog Number

Date

Sample Catalog #: EVL-30-24’-FL-120-1C-W

EVL- Edge Evo-lution OutlineEVLS- Edge Evolution Out-line Shallow

YEAR LEDWARRANTY

ConvertibleLED

ConvertibleLFL

LFL LED

YEAR LEDWARRANTY

ConvertibleLED

ConvertibleLFL

LFL LED

YEAR LEDWARRANTY

ConvertibleLED

ConvertibleLFL

LFL LED

YEAR LEDWARRANTY

ConvertibleLED

ConvertibleLFL

LFL LED

CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Extruded alumi-num module with reflector and lens for perfect perimeter illumination.

FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish on exposed trim. Driver cover to be painted standard white when custom color specified. Consult factory for custom colors.

LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted.

MOUNTING Edge Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF for individual and continuous runs (runs designed to fall on-grid). Consult factory for detailed installation instructions.

ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard.

LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥91, 30K, 35K, and 40K is CRI≥83. Minimum lifetime greater than 60,000 hours.

WARRANTY Edge Evolutuion LED offered with a 5-year limited warranty. Covers LED, driver and fixture.

COLOR/LUMENS

EVL_- ____- ___’- ___- ___- __- ______-HOUSING LENGTH MOUNTING1 VOLTAGE CIRCUITING FINISH OPTIONS

Matte WhiteMetallic Silver (rails only)9

Textured Black (rails only)9

Graphite (rails only)9

Bronze (rails only)9

Custom Color (rails only)9

W-S-BL-GR-BR-CC-

Inaccessible Ceiling

G1-G9-GS-GB-

1” (25.4mm) Ceiling Grid9/16” (14.3mm) Ceiling GridScrew Slot Ceiling Grid9/16” (14.3mm) Ceiling Grid with Bevel Trim

Standard 1/2” (12.7mm FlangeSpackle FlangeFlangeless4

FL-SF-NF-

Acoustical Grid Ceiling

120-277-347-UNV-

120 V277 V347 VUNV(120-277)

1C-1D-1B-

1E-

Single CircuitSingle Circuit Dimming5

Single Circuit with Battery Pack5, 6,11

Single Circuit with Emergency Circuit11

2-3-4-6-8-

2’, 23” (584.2mm) fixture2

3’, 35” (889mm) fixture2

4’, 47” (1,193.8mm) fixture2

6’, 71” (1,893.4mm) fixture2

8’, 95” (2,413mm) fixture2

Individual Units2

Continuous Runs3

xx’-Specify row length to 1’ (304.8mm) increments

1See back page for mounting detail. 2Individual units shipped with end plates uninstalled. 3Continuous runs made up of both even and odd length fixtures. Designed to fall on-grid. 4NF to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery packs with remote test switch are provided with 1B option. Available in 4’ or longer lengths. 7See back page for corner details. 8End Filler option used for fitting fixture into odd lengths. Filler is non-illuminated. Left and right end filler provided whe EF specified. 9Custom Color will be on fixture rails only. 10Osram/Sylvania Color Changing RGB LED and components are for accent or decorative lighting and does not provide room illumination. See back page for more information. 11Submittal drawings required. 12Low Glare Reflector (LGR) required on any layout with inside corner. LGR softens glare and changes polar cuvre and does effect lumen out put and efficacy, see back page for photometry. 13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago plenum, and GLR.

30-30HO-30VHO-

27-27HO-27VHO-30K Color Temperature Lumen Options

27K Color Temperature Lumen Options

40K Color Temperature Lumen Options40-40HO-40VHO-

35-35HO-35VHO-

35K, 209 lumens/ft (4.0 watts/ft) 35K, 398 lumens/ft (6.0 watts/ft)35K, 514 lumens/ft (8.0 watts/ft)

40K, 214 lumens/ft (4.0 watts/ft) 40K, 409 lumens/ft (6.0 watts/ft)40K, 527 lumens/ft (8.0 watts/ft)

30K, 200 lumens/ft (4.0 watts/ft) 30K, 381 lumens/ft (6.0 watts/ft)30K, 492 lumens/ft (8.0 watts/ft)

27K, 164 lumens/ft (4.0 watts/ft) 27K, 313 lumens/ft (6.0 watts/ft)27K, 404 lumens/ft (8.0 watts/ft)

35K Color Temperature Lumen Options

EDGEE V O L U T I O N

Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® March 2016

Quick Ship13

Chicago PlenumInternal Fast blow fuseLow Glare Reflector12

90˚ Inside Corner7,11

90˚ Outside Corner7,11

45˚ Inside Corner7,11

45˚ Outside Corner7,11

End Filler8

Step Switching

QS-CP-GLR-LGR-C90I-C90O-C45I-C45O-EF-SW-

RGB LED10

RGBX- RGB LED with DMX Controller

EVLS

Shallow (EVLS)

EVL

Standard (EVL)

4-1/2”(114.3mm) 4-1/2”

(114.3mm)

5-1/4”(133.4mm)

4-1/4”(107.9mm)

CL_____-CW____-

Specify color temp. and lumens/ft. (i.e. CL35300)

Specify color temp. and wattage/ft. (i.e. CW407)(Specify lumens/watts between standard offering listed above. Lumens are specified per color temp.)

Custom Output

Page 2: EDGE - Villa Lighting Supply, Inc....13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago

E V _ L

INDIVIDUAL AND CONTINUOUS RUN MODULES 1

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

APPLICATION GUIDELINES

MOUNTING

INSTALLATION

PHOTOMETRICS

Outline easily installs into acoustical grid and inaccessible ceiling. Install wall rail onto wall and hook fixture onto rail. Tie off fixture to structure. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See installation instructions for detailed information.

Outline is designed to install flush against the wall. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See instal-lation instructions for detailed information.

2'(1) module per 2' unit

4'(1) module per 4' unit

3'(1) module per 3' unit

8'(2) modules per 8' unit

6'(2) modules per 6' unit

1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.

23" (584.2mm)

35" (889mm)

47” (1193.8mm) or 48” (1219.2mm)

EV3WG

71” (1893.4mm) or 72” (1828.8mm)

95” (2413mm) or 96” (2438.4mm)

CORNERS

90° Outside

90° Inside

End Filler 45° Outside

45° Inside

90° Outside

90° Inside

End Filler 45° Outside

45° Inside

End Filler Detail

Inside Corner Detail

Outside Corner Detail

Pinnacle Lighting’s Outline is a complete perimeter lighting solution. The inside, outside corners, and end fillers allow designers to Outline a space. The 45 degree and 90 degree corners allow for +/- 5 degrees of adjustability to accommodate any wall imperfections. Specify runs to the nearest foot and non-illuminated corners are slid into place to finish the perimeter lighting. Minimum distance for corners is 5-1/2” from the wall, with a max of 12” away from the wall. The End Fillers have a maximum of 6” per end. See installation instructions for detailed information.

1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot and 9/16” Mounting Flange Detail Non-Flange Spackle Flange

G1 G1 G9 G9 GS GS FL NF SF

Specify G1 in Mounting section of part #.

Specify G9 in Mounting section of part #.

Specify GS in Mounting section of part #.

Specify FL of part #.

Specify NF of part #.

Specify SF of part #.

1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot and 9/16” Mounting Flange Detail Non-Flange Spackle Flange

G1 G1 G9 G9 GSGB GS FL NF SF

Specify G1 in Mounting section of part #.

Specify G9 in Mounting section of part #.

Specify GS in Mounting section of part #.

Specify FL of part #.

Specify NF of part #.

Specify SF of part #.

Test #: ITL84679Part #: EVL-35HO-4Lumens per watt: 66Total Delivered Lumens: 1592

873

655

437

218

Test #: ITL84682Part #: EVL-35HO-4-LGRLumens per watt: 57Total Delivered Lumens: 1376

720

540

360

180

Reflector

Low Glare Reflector

18”-20” Illumination

Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® March 2016

Page 3: EDGE - Villa Lighting Supply, Inc....13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago

PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com March 2016© 2016 Pinnacle Architectural Lighting™

Row Layout with End FillersIlluminatedLength

Max.Length

Min.Length

OptimalLength

3’

2’

4’

5’

6’

7’

8’

9’

10’

11’

12’

13’

14’

15’

16’

17’

18’

19’

20’

21’

22’

23’

24’

25’

4’-11”

3’-11”

5’-11”

6’-11”

7’-11”

8’-11”

9’-11”

10’-11”

11’-11”

12’-11”

13’-11”

14’-11”

15’-11”

16’-11”

17’-11”

18’-11”

19’-11”

20’-11”

21’-11”

22’-11”

23’-11”

24’-11”

25’-11”

28’-11”

3’-1” 3’-11”

2’-1” 2’-11”

4’-1” 4’-11”

5’-1” 5’-11”

6’-1” 6’-11”

7’-1” 7’-11”

8’-1” 8’-11”

9’-1” 9’-11”

10’-1” 10’-11”

11’-1” 11’-11”

12’-1” 12’-11”

13’-1” 13’-11”

14’-1” 14’-11”

15’-1” 15’-11”

16’-1” 16’-11”

17’-1” 17’-11”

18’-1” 18’-11”

19’-1” 19’-11”

20’-1” 20’-11”

21’-1” 21’-11”

22’-1” 22’-11”

23’-1” 23’-11”

24’-1” 24’-11”

25’-1” 25’-11”

Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs.

Edge Evolution Outline end fillers allow for wall-to-wall fixture installation. The fillers are installed to the end of the row filling the gap between the fixture end and the wall. End fillers are designed to be installed at the beginning and end of the row for optimal light distribution along the wall. Below are typical rows built of standard fixture lengths with end fillers at each end. The end fillers can increase a row length between 1” to 12” on either side with 1” to 6” being the optimal length to either end.

When ordering rows with end fillers, specify the illuminated row length in the LENGTH section of the part number and EF in the OPTIONS section of the part number for the End Fillers. Sample catalog #; EVL-30-24-G1-120-1D-W-EF

23” EFEF

EFEF 35”

EFEF 59”

EFEF 47”

EFEF 35”48”

EFEF 71”

EFEF 47”72”

EFEF 35”72”

EFEF 35”48”72”

EFEF 95”

EFEF 47”96”

EFEF 71”96”

EFEF 35”48”96”

EFEF 95”96”

EFEF 35”72”96”

EFEF 47”72”96”

EFEF 35”96”96”

EFEF 47”96”96”

EFEF 71”96”96”

EFEF 35”48”96”96”

EFEF 95”96”96”

EFEF 35”72”96”96”

EFEF 35”48”72”96”

EFEF 35”96”

Nominal Fixture LengthsActual Fixture Lengths

2’ 3’ 4’ 5’ 6’ 8’23” 35” 47” or 48” 59” 71” or 72” 95” or 96”

Edge Evolution OutlineRow layout with End Fillers

Page 4: EDGE - Villa Lighting Supply, Inc....13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago

Edge Evolution OutlineRow layout with End Fillers

90° Outside

90° Inside

End Filler

End Filler

45° Outside

45° Inside

Begining of Row

Joining Fixture

90° Outside

90° Inside

End Filler

End Filler

45° Outside

45° Inside

Begining of Row

Joining Fixture

PLAN VIEW

End Filler

45° Outside Corner

45° Inside Corner

90°Inside Corner

90° Outside Corner

EF

C45O

C45I

C90I

C90O

1”

3/8”

4-1/4”

7”

0”

12”

9-11/16”

11-5/8”

13”

9-1/2”

Connector Part Number

Min. Length

Max. Length

End Fillers - Designed to be adjustable to allow a standard fixture to fit into a wall-to-wall opening. ie. If you have an opening that is 51” order a 4’ (47”) fixture and End Fillers to fill in 2” inches on either side.

Outside Corners - Designed to go around outside corners allowing you to light a straight wall turn a corner and light another wall. (Numbers shown are wall dimension)

Inside Corners - Designed to go into inside corners allowing you to light a straight wall turn a corner and light another wall.

Rough in for outside corner is from begining of row length to far end of joining fixture.

PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com March 2016© 2016 Pinnacle Architectural Lighting™Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs.