L U M I N A I R E S P E C I F I C A T I O N
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previous printed or electronic versions.
OUTLINELED Recessed Linear Perimeter Slot System
Project Name
TypeCatalog Number
Date
Sample Catalog #: EVL-30-24’-FL-120-1C-W
EVL- Edge Evo-lution OutlineEVLS- Edge Evolution Out-line Shallow
YEAR LEDWARRANTY
ConvertibleLED
ConvertibleLFL
LFL LED
YEAR LEDWARRANTY
ConvertibleLED
ConvertibleLFL
LFL LED
YEAR LEDWARRANTY
ConvertibleLED
ConvertibleLFL
LFL LED
YEAR LEDWARRANTY
ConvertibleLED
ConvertibleLFL
LFL LED
CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Extruded alumi-num module with reflector and lens for perfect perimeter illumination.
FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish on exposed trim. Driver cover to be painted standard white when custom color specified. Consult factory for custom colors.
LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted.
MOUNTING Edge Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF for individual and continuous runs (runs designed to fall on-grid). Consult factory for detailed installation instructions.
ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard.
LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥91, 30K, 35K, and 40K is CRI≥83. Minimum lifetime greater than 60,000 hours.
WARRANTY Edge Evolutuion LED offered with a 5-year limited warranty. Covers LED, driver and fixture.
COLOR/LUMENS
EVL_- ____- ___’- ___- ___- __- ______-HOUSING LENGTH MOUNTING1 VOLTAGE CIRCUITING FINISH OPTIONS
Matte WhiteMetallic Silver (rails only)9
Textured Black (rails only)9
Graphite (rails only)9
Bronze (rails only)9
Custom Color (rails only)9
W-S-BL-GR-BR-CC-
Inaccessible Ceiling
G1-G9-GS-GB-
1” (25.4mm) Ceiling Grid9/16” (14.3mm) Ceiling GridScrew Slot Ceiling Grid9/16” (14.3mm) Ceiling Grid with Bevel Trim
Standard 1/2” (12.7mm FlangeSpackle FlangeFlangeless4
FL-SF-NF-
Acoustical Grid Ceiling
120-277-347-UNV-
120 V277 V347 VUNV(120-277)
1C-1D-1B-
1E-
Single CircuitSingle Circuit Dimming5
Single Circuit with Battery Pack5, 6,11
Single Circuit with Emergency Circuit11
2-3-4-6-8-
2’, 23” (584.2mm) fixture2
3’, 35” (889mm) fixture2
4’, 47” (1,193.8mm) fixture2
6’, 71” (1,893.4mm) fixture2
8’, 95” (2,413mm) fixture2
Individual Units2
Continuous Runs3
xx’-Specify row length to 1’ (304.8mm) increments
1See back page for mounting detail. 2Individual units shipped with end plates uninstalled. 3Continuous runs made up of both even and odd length fixtures. Designed to fall on-grid. 4NF to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery packs with remote test switch are provided with 1B option. Available in 4’ or longer lengths. 7See back page for corner details. 8End Filler option used for fitting fixture into odd lengths. Filler is non-illuminated. Left and right end filler provided whe EF specified. 9Custom Color will be on fixture rails only. 10Osram/Sylvania Color Changing RGB LED and components are for accent or decorative lighting and does not provide room illumination. See back page for more information. 11Submittal drawings required. 12Low Glare Reflector (LGR) required on any layout with inside corner. LGR softens glare and changes polar cuvre and does effect lumen out put and efficacy, see back page for photometry. 13Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago plenum, and GLR.
30-30HO-30VHO-
27-27HO-27VHO-30K Color Temperature Lumen Options
27K Color Temperature Lumen Options
40K Color Temperature Lumen Options40-40HO-40VHO-
35-35HO-35VHO-
35K, 209 lumens/ft (4.0 watts/ft) 35K, 398 lumens/ft (6.0 watts/ft)35K, 514 lumens/ft (8.0 watts/ft)
40K, 214 lumens/ft (4.0 watts/ft) 40K, 409 lumens/ft (6.0 watts/ft)40K, 527 lumens/ft (8.0 watts/ft)
30K, 200 lumens/ft (4.0 watts/ft) 30K, 381 lumens/ft (6.0 watts/ft)30K, 492 lumens/ft (8.0 watts/ft)
27K, 164 lumens/ft (4.0 watts/ft) 27K, 313 lumens/ft (6.0 watts/ft)27K, 404 lumens/ft (8.0 watts/ft)
35K Color Temperature Lumen Options
EDGEE V O L U T I O N
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® March 2016
Quick Ship13
Chicago PlenumInternal Fast blow fuseLow Glare Reflector12
90˚ Inside Corner7,11
90˚ Outside Corner7,11
45˚ Inside Corner7,11
45˚ Outside Corner7,11
End Filler8
Step Switching
QS-CP-GLR-LGR-C90I-C90O-C45I-C45O-EF-SW-
RGB LED10
RGBX- RGB LED with DMX Controller
EVLS
Shallow (EVLS)
EVL
Standard (EVL)
4-1/2”(114.3mm) 4-1/2”
(114.3mm)
5-1/4”(133.4mm)
4-1/4”(107.9mm)
CL_____-CW____-
Specify color temp. and lumens/ft. (i.e. CL35300)
Specify color temp. and wattage/ft. (i.e. CW407)(Specify lumens/watts between standard offering listed above. Lumens are specified per color temp.)
Custom Output
E V _ L
INDIVIDUAL AND CONTINUOUS RUN MODULES 1
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
APPLICATION GUIDELINES
MOUNTING
INSTALLATION
PHOTOMETRICS
Outline easily installs into acoustical grid and inaccessible ceiling. Install wall rail onto wall and hook fixture onto rail. Tie off fixture to structure. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See installation instructions for detailed information.
Outline is designed to install flush against the wall. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See instal-lation instructions for detailed information.
2'(1) module per 2' unit
4'(1) module per 4' unit
3'(1) module per 3' unit
8'(2) modules per 8' unit
6'(2) modules per 6' unit
1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
23" (584.2mm)
35" (889mm)
47” (1193.8mm) or 48” (1219.2mm)
EV3WG
71” (1893.4mm) or 72” (1828.8mm)
95” (2413mm) or 96” (2438.4mm)
CORNERS
90° Outside
90° Inside
End Filler 45° Outside
45° Inside
90° Outside
90° Inside
End Filler 45° Outside
45° Inside
End Filler Detail
Inside Corner Detail
Outside Corner Detail
Pinnacle Lighting’s Outline is a complete perimeter lighting solution. The inside, outside corners, and end fillers allow designers to Outline a space. The 45 degree and 90 degree corners allow for +/- 5 degrees of adjustability to accommodate any wall imperfections. Specify runs to the nearest foot and non-illuminated corners are slid into place to finish the perimeter lighting. Minimum distance for corners is 5-1/2” from the wall, with a max of 12” away from the wall. The End Fillers have a maximum of 6” per end. See installation instructions for detailed information.
1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot and 9/16” Mounting Flange Detail Non-Flange Spackle Flange
G1 G1 G9 G9 GS GS FL NF SF
Specify G1 in Mounting section of part #.
Specify G9 in Mounting section of part #.
Specify GS in Mounting section of part #.
Specify FL of part #.
Specify NF of part #.
Specify SF of part #.
1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot and 9/16” Mounting Flange Detail Non-Flange Spackle Flange
G1 G1 G9 G9 GSGB GS FL NF SF
Specify G1 in Mounting section of part #.
Specify G9 in Mounting section of part #.
Specify GS in Mounting section of part #.
Specify FL of part #.
Specify NF of part #.
Specify SF of part #.
Test #: ITL84679Part #: EVL-35HO-4Lumens per watt: 66Total Delivered Lumens: 1592
873
655
437
218
Test #: ITL84682Part #: EVL-35HO-4-LGRLumens per watt: 57Total Delivered Lumens: 1376
720
540
360
180
Reflector
Low Glare Reflector
18”-20” Illumination
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2016 Pinnacle Architectural Lighting® March 2016
PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com March 2016© 2016 Pinnacle Architectural Lighting™
Row Layout with End FillersIlluminatedLength
Max.Length
Min.Length
OptimalLength
3’
2’
4’
5’
6’
7’
8’
9’
10’
11’
12’
13’
14’
15’
16’
17’
18’
19’
20’
21’
22’
23’
24’
25’
4’-11”
3’-11”
5’-11”
6’-11”
7’-11”
8’-11”
9’-11”
10’-11”
11’-11”
12’-11”
13’-11”
14’-11”
15’-11”
16’-11”
17’-11”
18’-11”
19’-11”
20’-11”
21’-11”
22’-11”
23’-11”
24’-11”
25’-11”
28’-11”
3’-1” 3’-11”
2’-1” 2’-11”
4’-1” 4’-11”
5’-1” 5’-11”
6’-1” 6’-11”
7’-1” 7’-11”
8’-1” 8’-11”
9’-1” 9’-11”
10’-1” 10’-11”
11’-1” 11’-11”
12’-1” 12’-11”
13’-1” 13’-11”
14’-1” 14’-11”
15’-1” 15’-11”
16’-1” 16’-11”
17’-1” 17’-11”
18’-1” 18’-11”
19’-1” 19’-11”
20’-1” 20’-11”
21’-1” 21’-11”
22’-1” 22’-11”
23’-1” 23’-11”
24’-1” 24’-11”
25’-1” 25’-11”
Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs.
Edge Evolution Outline end fillers allow for wall-to-wall fixture installation. The fillers are installed to the end of the row filling the gap between the fixture end and the wall. End fillers are designed to be installed at the beginning and end of the row for optimal light distribution along the wall. Below are typical rows built of standard fixture lengths with end fillers at each end. The end fillers can increase a row length between 1” to 12” on either side with 1” to 6” being the optimal length to either end.
When ordering rows with end fillers, specify the illuminated row length in the LENGTH section of the part number and EF in the OPTIONS section of the part number for the End Fillers. Sample catalog #; EVL-30-24-G1-120-1D-W-EF
23” EFEF
EFEF 35”
EFEF 59”
EFEF 47”
EFEF 35”48”
EFEF 71”
EFEF 47”72”
EFEF 35”72”
EFEF 35”48”72”
EFEF 95”
EFEF 47”96”
EFEF 71”96”
EFEF 35”48”96”
EFEF 95”96”
EFEF 35”72”96”
EFEF 47”72”96”
EFEF 35”96”96”
EFEF 47”96”96”
EFEF 71”96”96”
EFEF 35”48”96”96”
EFEF 95”96”96”
EFEF 35”72”96”96”
EFEF 35”48”72”96”
EFEF 35”96”
Nominal Fixture LengthsActual Fixture Lengths
2’ 3’ 4’ 5’ 6’ 8’23” 35” 47” or 48” 59” 71” or 72” 95” or 96”
Edge Evolution OutlineRow layout with End Fillers
Edge Evolution OutlineRow layout with End Fillers
90° Outside
90° Inside
End Filler
End Filler
45° Outside
45° Inside
Begining of Row
Joining Fixture
90° Outside
90° Inside
End Filler
End Filler
45° Outside
45° Inside
Begining of Row
Joining Fixture
PLAN VIEW
End Filler
45° Outside Corner
45° Inside Corner
90°Inside Corner
90° Outside Corner
EF
C45O
C45I
C90I
C90O
1”
3/8”
4-1/4”
7”
0”
12”
9-11/16”
11-5/8”
13”
9-1/2”
Connector Part Number
Min. Length
Max. Length
End Fillers - Designed to be adjustable to allow a standard fixture to fit into a wall-to-wall opening. ie. If you have an opening that is 51” order a 4’ (47”) fixture and End Fillers to fill in 2” inches on either side.
Outside Corners - Designed to go around outside corners allowing you to light a straight wall turn a corner and light another wall. (Numbers shown are wall dimension)
Inside Corners - Designed to go into inside corners allowing you to light a straight wall turn a corner and light another wall.
Rough in for outside corner is from begining of row length to far end of joining fixture.
PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com March 2016© 2016 Pinnacle Architectural Lighting™Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs.