4
Represented by: DORMA BWN OPERATING MANUAL “The Automatic Door Experts” A Member of the Dorma Group of Companies FOR OTHER COUNTRIES PLEASE CALL DORMA BWN HEAD OFFICE DORMA BWN HEAD OFFICE & MAJOR NATIONAL CENTRES AUSTRALIAN MADE DORMA BWN Automatics Pty Ltd Head Office 46 Abbott Road Hallam, Victoria AUSTRALIA 3803 Tel. +61 (3) 9796 4111 Fax. +61 (3) 9796 3767 www.bwn.com.au DORMA BWN Automatics Pty Ltd Unit 1 Block V 391 Park Road Regents Park, New South Wales AUSTRALIA 2143 Tel. +61 (2) 9738 8222 Fax. +61 (2) 9738 8022 Edington Automatic Doors DORMA BWN Automatics Pty Ltd 44 Harries Road Coorparoo, Queensland AUSTRALIA 4151 Tel. +61 (7) 3394 3477 Fax. +61 (7) 3394 2953 Dorma Horizon NZ Ltd 20 Sylvia Park Road Mt Wellington, Auckland NEW ZEALAND Tel. +64 (9) 573 1999 Fax. +64 (9) 573 1991 Authorised Agents and Distributors Auto Door Systems 36 Crompton Road Rockingham,Western Australia AUSTRALIA 6168 Tel. +61 (8) 9527 2981 Fax. +61 (8) 9592 6242 Stratford Services Pty Ltd 2A Meredith Street Newton, South Australia AUSTRALIA 5074 Tel. +61 (8) 8337 3077 Fax. +61 (8) 8336 9431 Architectural Hardware 78 Winnellie Road Winnellie, Northern Territory AUSTRALIA 0821 Tel. +61 (8) 8984 4566 Fax. +61 (8) 8984 3339 Bright Lights Electrical (ACT) Pty Ltd 3/12 Sandford Street Mitchell, ACT AUSTRALIA 2911 Tel. +61 (2) 6241 0008 Fax. +61 (2) 6241 9069

Dorma Automatic Door

Embed Size (px)

DESCRIPTION

DORMA

Citation preview

Page 1: Dorma Automatic Door

Represented by:

DORMA BWN

OPERATING

MANUAL

“ T h e A u t o m a t i c D o o r E x p e r t s ”A Member of the Dorma Group of Companies

FOR OTHER COUNTRIES PLEASE CALL DORMA BWN HEAD OFFICE

DORMA BWN HEAD OFFICE & MAJOR NATIONAL CENTRES

AUSTRALIAN MADE

DORMA BWN Automatics Pty LtdHead Office46 Abbott RoadHallam, VictoriaAUSTRALIA 3803

Tel. +61 (3) 9796 4111Fax. +61 (3) 9796 3767www.bwn.com.au

DORMA BWN Automatics Pty LtdUnit 1 Block V 391 Park RoadRegents Park, New South WalesAUSTRALIA 2143

Tel. +61 (2) 9738 8222Fax. +61 (2) 9738 8022

Edington Automatic DoorsDORMA BWN Automatics Pty Ltd44 Harries RoadCoorparoo, QueenslandAUSTRALIA 4151

Tel. +61 (7) 3394 3477Fax. +61 (7) 3394 2953

Dorma Horizon NZ Ltd20 Sylvia Park RoadMt Wellington, AucklandNEW ZEALAND

Tel. +64 (9) 573 1999Fax. +64 (9) 573 1991

Authorised Agents and Distributors

Auto Door Systems36 Crompton RoadRockingham,Western AustraliaAUSTRALIA 6168

Tel. +61 (8) 9527 2981Fax. +61 (8) 9592 6242

Stratford Services Pty Ltd2A Meredith StreetNewton, South AustraliaAUSTRALIA 5074

Tel. +61 (8) 8337 3077Fax. +61 (8) 8336 9431

Architectural Hardware78 Winnellie RoadWinnellie, Northern TerritoryAUSTRALIA 0821

Tel. +61 (8) 8984 4566Fax. +61 (8) 8984 3339

Bright Lights Electrical (ACT) Pty Ltd3/12 Sandford StreetMitchell, ACTAUSTRALIA 2911

Tel. +61 (2) 6241 0008Fax. +61 (2) 6241 9069

Page 2: Dorma Automatic Door

DORMA BWN

AUTOMATIC DOOR

OPERATING MANUAL

2

Features . . . . . . . . . . . . . . . . . . . .1

Standard Accessories . . . . . . . . . .3

Mode Switching . . . . . . . . . . . . . .4

Failsafe System . . . . . . . . . . . . . . .5

Battery Monitoring . . . . . . . . . . . .5

Safety Photoelectric P.E. Cells . . . .5

Fire Alarm . . . . . . . . . . . . . . . . . .5

Malfunction . . . . . . . . . . . . . . . . . .5

Climate Control . . . . . . . . . . . . . .5

Trouble Shooting . . . . . . . . . . . . .6

The features of the Automatic Door Logic Controller include:–

1. Dual photo electric safety beams

2. Safety reverse on closing cycle

3. Low speed retry from safety reverse

4. Safety stop on opening cycle

5. Security control interface

6. People counting capability

7. Fully automatic ‘failsafe’

8. Fully adjustable opening and closing speeds

9. Fully adjustable dwell opening time

10. Four mode functions (open, auto, exit, off)

11. Selectable fire alarm interface

12. Climate Control (auto, manual)

Features:

Table of Contents

“Thank you for purchasing aDORMA BWN Automatic Door Operator”

DORMA BWN Automatics Pty Ltd is Australia’s leadingmanufacturer, designer and exporter of Automatic Door equipment.We incorporate a Logic Controller System which is the latest inmicroprocessor based technology suitable for automatic doorcontrol systems. The Logic Controllers operating parameters can beadjusted to accommodate various climatic conditions and specificsite requirements in relation to speed, braking, etc.

The benefits to you, our customer, will become apparent over theperiod of ownership. At DORMA BWN Automatics Pty Ltdwe have included hundreds of features during our thirty years ofbusiness into our products so that the main tangible benefit is areliable and trouble-free entry to your building. Should your DoorOperator ever give you any trouble, the additional benefit of thegenuine manufacturers warranty, extensive service network andspare parts facilities will have your Automatic Door returned to safeoperation and the entry to your place of business again fullyfunctional.

Page 3: Dorma Automatic Door

Mode Switching

There are four (4) standard modes that the Automatic Door Operator will operatein.They are:–

1. OFF: (For After Hours/Locking)The door will close and turn off so as to be manually locked.The door can also be moved manually to any position in thismode for cleaning and maintenance.

If a DORMA BWN electric locking system is fitted thenthe door will close and lock automatically. Entry or exitfrom the building is obtained via either keyswitch or remoteactuation.

2. EXIT:The door will automatically open when approached fromthe inside but not from the outside. This mode is used toallow people to leave the building after hours or at closingtime, it restricts people from coming in. If the DORMABWN locking system is used the door will also lockautomatically after each cycle in this mode.

3.AUTO: (For Normal Business Hours)In this position the doors will open and close automaticallysubject to the sensors activating upon an approachingperson.

4. OPEN:In this position the door will drive fully open and remainthere.This mode may be used whilst moving equipment inand out of the building or to hold the door open forcleaning or repair.

The door should be controlled by the mode switch at all times.The onlytime the mode switch is not used is when the unit has been interfacedwith a security system.The power to the unit should only be turned off formaintenance to the unit.

4

OFF

OPEN

EXIT

AUTO

OFF

OPEN

EXIT

AUTO

OFF

OPEN

EXIT

AUTO

OFF

OPEN

EXIT

AUTO

User Guide –Operator Standard Accessories

3

DO

RM

A B

WN

OP

ER

ATO

R

STA

ND

AR

D G

PO24

0V –

10A

(by

othe

rs)

SA

FE

TY

P.E

.CE

LL

S(S

idel

ight

fra

me)

●Pr

ojec

ts b

eam

acr

oss

door

way

.If

any

obje

ct (

e.g.

pers

on,b

ox)

brea

ks t

he b

eam

the

doo

r w

illho

ld o

pen.

FL

OO

RG

UID

ES

●R

olle

rs t

o gu

ide

door

as

it op

ens

and

clos

es.

SE

NS

OR

●M

ovem

ent

Det

ecto

r.●

One

eac

h si

de.

SW

ITC

HIN

G●

Usu

al m

ode

switc

hlo

catio

n.●

Usu

al r

eset

but

ton

loca

tion.

INS

IDE

EL

EV

AT

ION

600

150

Page 4: Dorma Automatic Door

6

Trouble Shooting

TROUBLE REMEDY

Door will not close

Door will not open

Door will only open fromone side

Door opens/closes by itself

Alarm (continuous highpitch) sounding and red lighton “Back-up System” switch

● Check 240V power is turned on

● Check Four Position switch is in the AutoMode

● Check there is no object or materialcovering the light cells (safety beam)

● Check there are no obstructions – i.e.stones under door, rubber mat, etc.

● Check 240V power is turned on

● Check Four Position switch is in the AutoMode

● Check Four Position switch is not in ExitMode

● Check for moving objects in the sensordetection area, e.g. cobwebs on sensor,moving plants.

● Press RESET button on “Back-up System”switch. Alarm should cease. If not, contactyour authorised BWN Service Agent.

FAILSAFE SYSTEM – (Loss of 240V Mains Power)In the event of a power failure the door will automatically open if in ‘AUTO’ modeusing the DORMA BWN Invertor. This is to allow people to exit the building in caseof emergency. In ‘EXIT’ or ‘LOCK’ mode if a DORMA BWN electric lock is fitted theunit will remain closed and locked until the ‘emergency exit’ button is pressed. If theoutside key switch is used this will unlock the door and it will open via the invertorfailsafe.The door will automatically reset once power has been restored.

BATTERY MONITORINGIf a DORMA BWN invertor is fitted a red light and a resetbutton will be provided. The invertor battery voltage ismonitored and if it falls below a preset value the red light andbuzzer will turn on. By pressing the reset button the buzzer willturn off but the red light will remain on indicating a service callis required, (i.e. battery low).

SAFETY PHOTOELECTRIC (P.E.) CELLSThe automatic door operator has two (2) sets of safety P.E. cellsfitted across the doorway. Each set is comprised of a transmitter

and a receiver. One (1) set is positioned at approximately 150mm from floor leveland other at 600mm from floor level.These are designed to prevent the door fromclosing on a person or object that is stationary in the doorway.The safety P.E. cellswork in all modes.The safety P.E. cells can be turned off in ‘LOCK’ mode for securityreasons upon request. Note: Breaking the safety P.E. beams whilst the doors arelocked will not open the door.

FIRE ALARMThe automatic door operator can easily be interfaced with a signal from the fireindicator board. Upon receiving a signal the unit will either automatically open orclose dependent on fire authority requirement.

MALFUNCTIONThe automatic door operator will automatically analyse information being fed to itand if it determines that the door is not operating to set parameters i.e. the door isstalled or jammed it will shut off power to the motor to avoid any major fault fromoccurring.

CLIMATE CONTROL (Contact your agent to activate)Manual climate control (if fitted) will allow a switch to select from four (4) differentdoor openings, one at full opening the others at a reduced distance that can beprogrammable up to 100% of full opening.

Automatic climate control, if activated, will automatically adjust the opening distancedependant on traffic volume.

5

BACK-UP SYSTEM

FAULT

RESET

Under no circumstances should anyone other than an authorised DORMA BWNService Agent open the cover to adjust the Automatic Door operator.DORMA BWN Automatics Pty Ltd recommends that your automatic dooroperators be regularly maintained by an authorised DORMA BWN Service agent toensure safety and longevity of operation. Please contact your local AuthorisedService agent to enquire about a maintenance program that best suites your needs.

Your DORMA BWN automatic door operator is cover by a 1-year labour and 2-yearparts warranty and any warranty work must be carried out by an authorisedDORMA BWN Service representative or agent. Any work carried out on theautomatic door other than by an authorised agent may void the warranty.