2
DORMA TS 93 Cam actiondoor closer system
TS 93 GB
DORMA TS 93 – Cam action door closer system
Versatile andelegant
The TS 93 cam action doorcloser system provides ahigh-quality architecturalsolution for all project application requirements. Theproven DORMA technologyfeaturing the heart-shapedcam ensures exceptionalease of opening.
The new Contur designoffers an even more impres-sive specification - thanks to2 concealed fixings2 height-adjustable G-N
slide channel 2 delayed closing action as
standard2 smoke detector integrated
in the slide channel2 simple, fast installation
Rapidly decreasing opening forceThe DORMA TS 93 system’sunique cam technology setsit apart from conventionaldoor closer systems. Theresistance encounteredwhen opening the door isinstantly reduced, offeringan easy opening actionmuch appreciated by, in particular, children andolder people.
0°0
20
10
30
50
40
Nm
30° 60° 90° 120° 150° 180°
Force profileDORMA TS 93(Spring strength: EN 3)
Opening forceClosing force
TS 93 G-SR-EMR
3TS 93 GB
Further information, specification textsAdditional information e.g.specification texts, drawings,installation instructions onmany products can beaccessed via electronicmedia (Internet, CD ROM).
PageFeatures and functions 4
DORMA TS 93 B Door closer for pull-side door leaf fixing/push-side transom fixing 6
DORMA TS 93 G Door closer for push-side door leaf fixing/pull-side transom fixing 7
DORMA G-N Standard slide channel design 8
DORMA RF Hold-open unit 8
DORMA G-EMF Slide channel with electro-mechanical hold-open 10
DORMA G-EMR Slide channel with electro-mechanicalhold-open and integral smoke detector 12
DORMA G-SR Door co-ordinator slide channel for pull-side fixing 14
DORMA G-SR-EMF Door co-ordinator slide channel with integralelectro-mechanical hold-open for pull-side fixing 14
DORMA G-SR-EMR Door co-ordinator slide channel with electro-mechanical hold-open and integral smoke detector for pull-side fixing 14
DORMA G-SR/BG Door co-ordinator slide channel for push-side fixing 18
DORMA G-SR-EMF/BG Door co-ordinator slide channel with integralelectro-mechanical hold-open for push-side fixing 18
DORMA G-SR-EMR/BG Door co-ordinator slide channel with electro-mechanical hold-open and integral smoke detector for push-side fixing 18
DORMA RMZ, DORMA RM Frame-mounted and ceiling-mounted smoke detectors 22
Accessories 24
Hold-open systemsRegulations and information 27
Range of equipment and optional accessories Single doors 28
Range of equipment and optional accessoriesDouble doors 30
Specification textsSingle doors 32
Specification textsDouble doors 34
Contents
TS 93 N
TS 93 EMF
TS 93 EMR
4
DORMA TS 93 Cam actiondoor closer system
TS 93 GB
EN ENVariable closing force Spring strength 2–5 5–7Standard doors2) ≤ 1250 mm 2 –
≤ 1600 mm – 2External doors, ≤ 1250 mm 2 –outward opening2) ≤ 1600 mm – 2For fire and ≤ 1250 mm 2 –smoke check doors2) ≤ 1600 mm – 2Non-handed 2 2Arm assembly type Standard – –
Slide channel 2 2Closing force variable by means of adjustment screw 2 2Closing speed adjustable by valve 2 2Latching speed at arm – –adjustable at valve 2 2Backcheck (BC/ÖD) adjustable
at valve 2 2Delayed action (DC/SV)adjustable at valve 2 2Hold-open " "Weight in kg 3,5 5,2Dimensions in mm Length (L) 275 285
Overall depth (B) 253 262Height (H) 260 271
Door closer tested to EN 1154 2Hold-open devices tested to EN 1155 2Door co-ordinators tested to EN 1158 2
mark for building products 22 yes – no " option
Data and features TS 93 B/G1)The perfect project solution for all application needsThe TS 93 cam action doorcloser system sets new stan-dards in user convenience in project applications. Theproven DORMA technologyof the heart-shaped camensures exceptional ease ofopening.
The TS 93 series comprisesa modular system whichenables just a few door closer models to be combinedwith a number of differentslide channels to meet virtually every conceivablefunctional requirement. Doorsof varying designs can beequipped for a wide range ofdifferent applications.
…for the trade2 Clear product allocation
ensures use of the rightmodels for the right appli-cations.
2 Identical door closermodel for single and double doors
…for the installer2 The TS 93 system is suita-
ble for all fixing positions.2 Mounting bracket with
universal fixing hole pattern for optimal fixing.
2 Simple, fast installation.
…for the specifier/architect2 High-quality design
ensures an ideal solutionfor all project applications.
2 Harmonious appearancethanks to integral smokedetector.
2 Available in a wide rangeof colours and finishes.
…for the user2 Easy opening action and
fully controlled closing.2 Smoke detector with
convenient service andmaintenance indicator.
2 Adjustable hydraulic func-tions for easy adaptationto each specific door situation.
1) B = Standard model for pull-side door leaf fixing/push-side transom fixingG = Special model for push-side door leaf fixing/pull-side transom fixing.
2) For applications involving particularly heavy or wide doors, and doors which have to close against wind resistance, the next highest door closer size should be selected, or the closing force adjusted to a higher setting.
Plus points…
116020
97
428
500
31
53
56
16091
275
8
1616
43
38
117120
108
428
500
56
160
91285
8
1616
43
38
31
62
DORMA TS 93,Size EN 2 – 5
DORMA TS 93,Size EN 5 – 7
5TS 93 GB
12
4
3
Standard mounting backplate with universalfixing hole systemThis mounting backplate withits universal hole system,including hole pattern tosupplementary sheet 1 ofDIN EN 1154 A, ensuresideal fixing whatever theconditions and irrespectiveof the door type. The fixinghole patterns are the same for both sizes of theDORMA TS 93. Additionalmounting plates/brackets are no longer required.Alignment dowels on themounting backplate facilitatelocation of the closer body.
BackcheckThe backcheck feature ensures the safe decelerationand restraint of a door whichhas been flung open orcaught by a gust of wind.This effectively reduces the danger of the door andadjacent wall being damaged.
Delayed actionThe delayed action featureretards the closing cyclebetween 120° and 70°(approximate values for pull-side door leaf fixing). Theextra time allowed for passage through the doorwaycan be essential for peoplewith luggage or bulky items:mothers with prams, personnel with tea trolleys,post trolleys, hospital beds,etc.; and also for disabledpeople.
120°70°
4
3
2
1
70°3
120°70°
4
1 Fully controlled closingaction with adjustablespeed
2 Adjustable latch speed3 Adjustable backcheck4 Adjustable delayed action
3 Adjustable backcheck
4 Adjustable delayed action
6
DORMA TS 93 B Door closers
TS 93 GB
max. 164
2 65
16
143 428
33
4
142 160884
(80)
max. 30
154
38
1
160 1428 84(80)
4
143428
Door leaf fixing (standardarrangement) of the DORMATS 93 B on the pull side.Structural conditions permit-ting, an opening angle of180° is possible with thisfixing method. In mostcases, a wall recess mayhave to be provided for thedoor closer.
Example: Anticlockwise-closing (ISO 6) door; mirrored arrangements applyto clockwise-closing (ISO 5)doors.
The DORMA TS 93 B isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120,MM/IMM 240.
Transom fixing (overheadframe fixing) of the DORMATS 93 B on the push side.Backcheck and delayedaction non-operative with thisfixing arrangement. The dooropening angle is limited toapprox. 120° to 145°,depending on the structuralconditions. In order to pre-vent damage to the wall anddoor, a door stop should beinstalled to limit the maxi-mum angle of door opening.
Example: Anticlockwise-closing (ISO 6) door; mirroredarrangements apply to clok-kwise-closing (ISO 5) doors.
The DORMA TS 93 B isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120,MM/IMM 240.
( ) = TS 93 5–7
( ) = TS 93 5–7
Push-side transom fixing
Pull-side door leaf fixing
F Approval certification
F Approval certification
7TS 93 GB
DORMA TS 93 G
max. 264
32
8
81
428 143
16043
107
17
(45)49
max. 3
2843
81
142 160884(80)
143
17
428
Door leaf fixing (standardinstallation) of the DORMATS 93 G on the push side. The door opening angle islimited to approx. 120° to145°, depending on thestructural conditions. Inorder to prevent damage tothe wall and door, a doorstop should be installed tolimit the maximum angle of door opening.
A door stop must be installedfor fire and smoke doors.Example: Anticlockwise-closing (ISO 6) door; mirroredarrangements apply to clok-kwise-closing (ISO 5) doors.
The DORMA TS 93 G isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120,MM/IMM 240.
Transom fixing (overheadframe fixing) of the DORMATS 93 G on the pull side.Structural conditions permitting, an opening angle of 180° is possiblewith this fixing method.
Example: Anticlockwise-closing (ISO 6) door; mirrored arrangements applyto clockwise-closing (ISO 5)doors
The DORMA TS 93 G isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120, MM/IMM 240.
( ) = TS 93 5–7
( ) = TS 93 5–7
F Approval certification
Pull-side transom fixing
F Approval certification
Push-side door leaf fixing
Door closers
8
DORMA G-N, RF Slide channels
TS 93 GB
428
± 2,5
442
± 2,5
31
20
150°
75°
80°
The DORMA G-N slide channel assembly incorpo-rates the slide arm, slidechannel, slide block, fixingadapters, screws and endcaps. The DORMA G-N slide channel assembly isnon-handed and can becombined with all door closermodels.
Thanks to oblong holes inthe fixing adapters, the slidechannel can be effectivelyadjusted to variations in the drill hole pattern whilekeeping the gap betweendoor closer body and slidechannel aligned and parallel.
The DORMA G-N has beensuccessfully type-tested toEN 1154 in conjunctionwith the DORMA TS 93.Certificates are available onrequest.
The DORMA RF hold-openunit enables doors to besecurely held without anyfall-back at precisely therequired position up to anopening angle of approx.150°. The hold-open func-tion can be easily switchedon and off by the user, and
the release force can beadjusted to the door typeconcerned. The DORMA RFmechanism is non-handedand has been specificallydesigned for retrofitting tothe G-N type standard slidechannel.
The suitability of the hold-open unit may be limitedwhere the closer unit isfixed to the door leaf on thepush side, in combinationwith outward-opening doors,and also in the case oflarge, heavy doors.
Not for fire and smoke doors.
Accessories for the DORMAG-N, RF slide channel:Cushioned limit stay forretrofitting to the slide channel. Adjustable between80° and max. 120°.
The cushioned limit stay prevents the door from hitting the adjacent wallwhen opened normally.
The cushioned limit stay is not a heavy-duty protective device and inmany applications cannotsubstitute for a door stop.
F Approval certification
Standard model
Hold-open unit
Cushioned limit stay
Hold open range
Cushioned limit stay
max. 120°
9TS 93 GB
max. 16
42 6
516
143 428
33
4
142 160884
(80)
max. 30
154
38
1
160 1428 84(80)
4
143428
max. 3
2843
81
142 160884(80)
143
17
428
max. 26
43
28
81
428 143
16043
107
17
(45)49
DORMA TS 93 B door closer with DORMA G-N slide channel assembly, door leaf fixing on the pull side and transom fixing on the push side.Examples: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.
DORMA TS 93 G door closer with DORMA G-N slide channel assembly,door leaf fixing on the push side and transom fixing on the pull side.Examples: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.
( ) = TS 93 5 – 7
The door opening angle is limited to approx. 120° – 145° depending on the structural conditions. Use a cushioned limit stay or install a door stop.
( ) = TS 93 5 – 7
The door opening angle is limited to approx. 120° – 145° depending on the structural conditions. Use a cushioned limit stay or install a door stop.
( ) = TS 93 5 – 7
( ) = TS 93 5 – 7
10
DORMA G-EMF Slide channel assembly
TS 93 GB
428
518
34
30
120°
80°
The DORMA G-EMF slidechannel assembly enablesthe door to be held opensecurely at a preselectedposition without fall-back.The hold-open point can beadjusted within an openingangle of approx. 80° and 120°.NoteThe active leaf can be openedup to the maximum selectedhold-open point (door stopto be positioned accordingly).
In the event of an alarm or a fault in the power supply,the hold-open is releasedand the door is closed bythe door closer. The releaseis triggered by a signal fromexternal smoke detectors(e.g. DORMA RMZ orDORMA RM). The release force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure that
the door can also be easilyreleased manually.The DORMA G-EMF slidechannel assembly comprisesthe slide arm, slide channel,slide block, electro-mechan-ical hold-open unit, cover,fixing screws and end caps.The DORMA G-EMF is transom-fixed and non-handed.
In the case of particularlylarge and heavy doors (over1250 mm), or doors inwhich the hold-open pointrequired exceeds 120°, werecommend that DORMA EMhold-open magnets in conjunction with theDORMA RMZ central smokedetector be employed inste-ad of the electro-mechanicalhold-open unit.
Operating voltage 24 vDC, ± 15%
Power input 1.4 W
Rated for continuous duty (100%)
Release force adjustable
11,5
l 8 (24 V DC)
99 428
160
8
142
84(80)
434
max. 16
6516
42
l 8 (24 V DC)
99
85
81
2843
max. 26
17
49(45)
107
43
160
428
11,5
DORMA TS 93 B closer with DORMA G-EMF slide channel assembly, pull-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.
DORMA TS 93 G closer with DORMA G-EMF slide channel assembly, push-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.
Technical data
Electro-mechanical hold-open
( ) = TS 93 5 – 7
( ) = TS 93 5 – 7
Hold open range
= Door stop
11TS 93 GB
Hold-open system on a fireand smoke door, comprising:DORMA TS 93 B door closer,DORMA G-EMF slide channel assembly, DORMARMZ (smoke sensor, releaseswitching unit and stabilisedpower pack for 24 vDC) asframe-mounted smokedetector, plus one DORMARM smoke detector on bothsides of the door.(See also page 22.)
230 V AC RMZ
RM
G 93 EMF
TS 93
18 kΩ
HT
N LPE
167 18 49
1012 23 1411
121 kΩ
EMF
230 V AC
RMZ
RM
12
1514
1114
1313
12
8
10
56
44
11
RM
12
1514
1114
1313
12
89
10
12
2x121 k Ω
56
44
11
18 kΩ
23
11
7
12
11
923
7
2x121 k Ω
B 10 A
Example application
Regulations/Information
The use of hold-open devicesmay be subject to certainconditions – see page 27.
The DORMA TS 93 EMF hasbeen successfully type-testedto EN 1155, ElectricallyPowered Hold-Open Devices.Certificates are available onrequest.
F Approval certification
Recommended cabling:I - (St) Y 2 x 2 x 0,6
RS-AM (Optional)
12
DORMA G-EMR Slide channel
TS 93 GB
823
428
245
150
40
30
120°
80°
Power supply: 230 vAC, ± 10%
Operating voltage (internal): 24 vDC
Max. output rating: 9.8 W
Power input EMF: 1.4 W
Rated for continuous duty: 100%
Release force: adjustable
125 24
l 10 (230 V AC) l 8 (24 V DC)
max. 16
42
6516
443
5 5
142
84(80)
8
160
428
l 10 (230 V AC)
12524
5
l 8 (24 V DC)
5
max. 26
4328
81
428
49(45)
10716043
1730
DORMA TS 93 B closer with DORMA G-EMR slide channel assembly, pull-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.
DORMA TS 93 G door closer with DORMA G-EMR slide channel assembly, push-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.
Technical data
( ) = TS 93 5 – 7
( ) = TS 93 5 – 7
Electro-mechanical hold-open and integral smoke detector
The DORMA G-EMR slidechannel assembly enables fireand smoke doors to be heldopen securely at precisely theangle required, and monitoredand controlled completely in-dependently of other systems.The hold-open point can beadjusted to opening anglesbetween approx. 80° and 120°.
NoteThe active leaf can be openedup to the maximum selectedhold-open point (door stop tobe positioned accordingly). In the event of an alarm or a fault in the power supply,the hold-open is releasedand the door is closed bythe door closer. The release force for thehold-open mechanism can
be adjusted without toolsand is rated to ensure thatthe door can also be easilyreleased manually.The DORMA G-EMR slidechannel assembly comprisesthe arm, slide channel, slideblock, electro-mechanicalhold-open unit, smokedetector, power pack, cover,fixings and end caps. It isnon-handed, enabling usewith both RH/ISO 5 andLH/ISO 6 doors.A floating (volt-free) alarmcontact and connections forfurther detectors and externalmanual release devices areprovided. The G-SR-EMRDCW slide channel assembly
is also available without apower pack for integration inbuilding management andcontrol systems via a DCWbus and the DORMA TMSdoor management system.In the case of particularlylarge and heavy doors (over1250 mm), or doors inwhich the hold-open pointrequired exceeds 120°, werecommend that DORMA EMhold-open magnets beemployed instead of theelectro-mechanical hold-open unit, in conjunctionwith the DORMA RMZ-K/Sframe-mounted smokedetector.
Hold open range
= Door stop
13TS 93 GB
The DORMA TS 93 EMRhas been successfully type-tested to EN 1155,Electrically Powered Hold-Open Devices.Certificates are available onrequest.
F Approval certification
Hold-open system on a fireand smoke door, comprising:DORMA TS 93 B door closer,DORMA G-EMR slide channel assembly, plus oneDORMA RM smoke detectoron both sides of the door.(See also page 22.)
RM
G 93 EMR230 V AC
TS 93
18 k
HT
N LPE
167 18 49
1012 23 1411
121 kΩ230 V AC
EMR
RM
12
1514
1114
1313
12
8
10
Ω
56
44
11
RM
12
1514
1114
1313
12
89
10
12
2x121 k Ω
Ω
56
44
11
18 k
23
11
7
12
11
923
7
2x121 k Ω
B 10 A
Regulations/Information
Example application
The use of hold-open devicesmay be subject to certainconditions – see page 27.
Recommended cabling:I - (St) Y 2 x 2 x 0,6
RS-AM (Optional)
14
DORMA G-SRDORMA G-SR-EMFDORMA G-SR-EMR
Door co-ordinatorslide channel
TS 93 GB
The DORMA G-SR slidechannel with integral doorco-ordinator featuring apush rod clamping systemfor double doors, ensuresthat the active leaf alwayscloses after the inactive leaf.As this system operatesindependently of the doorcloser hydraulics, it offersmaximum safety and reliabi-
lity (doors prevented from“creeping closed”). An over-load release protects boththe door co-ordinator andthe door set from damage. The DORMA G-SR door co-ordinator is non-handedand suitable for combinationwith DORMA TS 93 B doorclosers.
Standard door co-ordinator (G-SR)
These door co-ordinators notonly ensure the correct closing sequence of doubledoors, but also allow thedoor leaves to be individuallyheld open. In the event ofan alarm or power failure,the hold-open is releasedand the door is closed bythe door closer.The release action is trigge-red by a signal from thesmoke detector integrated in the G-SR-EMR door co-ordinator.The G-SR-EMR DCW doorco-ordinator model is alsoavailable without a powerpack for integration in building management andcontrol systems via a DCWbus and the DORMA TMSdoor management system.
The pull-off force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure thatthe door can also be easilyreleased manually. DORMAG-SR-EMF and G-SR-EMRdoor co-ordinators are non-handed and suitable forcombination with DORMATS 93 B door closers.In the case of doors inwhich the hold-open pointrequired exceeds 130°, werecommend that DORMAEM hold-open magnets be applied instead of the electro-mechanical hold-open unit.
Door co-ordinator with electro-mechanical hold-open (G-SR-EMF)Door co-ordinator with integral smoke detector (G-SR-EMR)
The DORMA TS 93 G-SR has been successfully type-tested to EN 1158, Door Co-ordinator Devices.Certificates are available on request.
F Approval certification
Active leaf Inactive leaf
Active leaf Inactive leaf
Regulations/Information
The use of hold-open devicesmay be subject to certainconditions – see page 27.
G-SR-EMF24 V DC extern
Active leaf Inactive leaf
G-SR-EMR
230 V AC
Active leaf Inactive leaf
15TS 93 GB
This door co-ordinator containsjust one hold-open mechanism,located in the inactive leafslide channel, for holdingopen both door leaves. Thesingle-point hold-open posi-tion is adjustable betweenapprox. 80° and 130°.Note The active leaf can beopened up to the maximumselected hold-open point(door stop to be positionedaccordingly). The active leafcan be held open by thedoor co-ordinator at anyangle up to max. 150°.
With this door co-ordinator,the active leaf can be heldopen independently of theinactive leaf. The hold-openpoints for each leaf lie bet-ween approx. 80° and 130°. Note The active leaf can beopened up to the maximumselected hold-open point(door stop to be positionedaccordingly).
This door co-ordinator enablesthe active leaf to be held openindependently in special doorsets involving, for example,fixed side screens, narrowinactive leaves ("penny farthing" doors), etc. Thehold-open point lies betweenapprox. 80° and 130°.Note The active leaf can beopened up to the maximumselected hold-open point (door stop to be positionedaccordingly).
DORMA G-SR-EMF 1G
DORMA G-SR-EMF 2
DORMA G-SR-EMF 1
This door co-ordinator includes an integral smokedetector.A floating (volt-free) alarmcontact and connections for further detectors and external manual releasedevices are also provided. Technical data for smokedetectors: see page 22.
This door co-ordinator includes an integral smokedetector.A floating (volt-free) alarmcontact and connections for further detectors and external manual releasedevices are also provided. Technical data for smokedetectors: see page 22.
This door co-ordinator includes an integral smokedetector.A floating (volt-free) alarmcontact and connections for further detectors and external manual releasedevices are also provided. Technical data for smokedetectors: see page 22.
DORMA G-SR-EMR 1G
DORMA G-SR-EMR 2
DORMA G-SR-EMR 1
The DORMA TS 93 G-SR-EMF 1, EMF 2 and EMF 1Ghave been successfully type-tested to EN 1155,Electrically Powered Hold-Open Devices.Certificates are available onrequest.
Power supply EMR: 230 vAC ± 10%Max. output rating EMR: 9.8 WOperating voltage EMF: 24 vDC ± 15%Power input EMF 1: 1.4 W
EMF 2: 2.8 WRated for continuous duty: 100%Release force: adjustableIn the case of doors in which the hold-open point requiredexceeds 130°, we recommend that DORMA EM hold-openmagnets be employed instead of the electro-mechanicalhold-open unit.
F Approval certification Technical data
Active leaf Inactive leaf
= Door stop
approx.150° approx.
130°
approx.80°
Active leaf Inactive leaf
= Door stop
approx.130°
approx.130°
approx.80°
approx.80°
Active leaf Inactive leaf
= Door stop
approx.130°
approx.80°
The DORMA TS 93 G-SR-EMR 1, EMR 2 and EMR 1Ghave been successfully type-tested to EN 1155,Electrically Powered Hold-Open Devices.Certificates are available onrequest.
F Approval certification
16
DORMA G-SRDORMA G-SR-EMFDORMA G-SR-EMR
Slide channel door co-ordinators
TS 93 GB
Bmax. 16
30
42
1665
34
(80)
142
443
84
160
470
Standard door co-ordinator (G-SR)Door co-ordinator with electro-mechanical hold-open (G-SR-EMF)
max. 16
30
42
1665
55
31
(80)
142
443
84
160
470
34
Door co-ordinator with integral smoke detector (G-SR-EMR)
Inactive leafIn the case of unequal leaves, minimumwidth 370 mm
( ) = TS 93 EN 5-7
Inactive leaf
( ) = TS 93 EN 5-7
17TS 93 GB
B
115 470
84(80)
142160
l 8 (24 V DC)
A*
250
95
2,5
84(80)
142160
470444
l 8 (24 V DC)l 10 (230 V AC)
1700 – 3200*
34
Active leafFixing dimension BB (mm) Door width A (mm)88 1220 – 135034 more than 1350 – 3200
Active leaf
* In the case of particularly large and heavy doors (over 2500 mm), we recommend that DORMA EM hold-open magnetsbe employed instead of the electro-mechanical hold-open unit.
18
DORMA G-SR/BGDORMA G-SR-EMF/BGDORMA G-SR-EMR/BG
Slide channel door co-ordinators
TS 93 GB
The DORMA G-SR/BG push-side slide channel with integral door co-ordinator,featuring a push rod clam-ping system for doubledoors, ensures that the activeleaf always closes after theinactive leaf. As this systemoperates independently ofthe door closer hydraulics, itoffers maximum safety andreliability (doors preventedfrom “creeping closed”). Anoverload release protects boththe door co-ordinator andthe door set from damage.
The DORMA G-SR/BG doorcoordinator is non-handedand suitable for combinationwith DORMA TS 93 G doorclosers.Note:Max. opening angle 120°(door stop to be positionedaccordingly).Not suitable for emergencyexit doors which are openedat the inactive leaf.
Standard door co-ordinator (G-SR/BG)
These push-side door co-ordinators not only ensurethe correct closing sequenceof double doors, but alsoallow the door leaves to beindividually held open. Inthe event of an alarm orpower failure, the hold-openis released and the door isclosed by the door closer.The release is triggered by asignal from the smokedetector integrated in the G-SR-EMR/BG door co-ordi-nator.The G-SR-EMR DCW/BGdoor co-ordinator model isalso available without apower pack for integration inbuilding management andcontrol systems via a DCWbus and the DORMA TMSdoor management system.
The pull-off force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure thatthe door can also be easilyreleased manually.The DORMA G-SR-EMF/BGand G-SR-EMR/BG door co-ordinators are non-handedand suitable for combinationwith DORMA TS 93 G doorclosers.Not suitable for emergencyexit doors which are openedat the inactive leaf.
Door co-ordinator with electro-mechanical hold-open (G-SR-EMF/BG)Door co-ordinator with integral smoke detector (G-SR-EMR/BG)
The DORMA TS 93 G-SR/BGhas been successfully type-tested to EN 1158,Door Co-ordinator Devices.Certificates are available on request.
F Approval certification
Inactive leaf Active leaf
Active leafInactive leaf
= Door stop
approx.120°
approx.120°
Regulations/Information
The use of hold-open devicesmay be subject to certainconditions – see page 27.
G-SR-EMF24 V DC
Inactive leaf Active leaf
230 V AC
G-SR-EMR/BG
Inactive leaf Active leaf
19TS 93 GB
With this door co-ordinator,the active leaf can be heldopen independently of theinactive leaf. The hold-openpoints for each leaf lie bet-ween approx. 80° and 120°. Note The active leaf can beopened up to the maximumselected hold-open point(door stop to be positionedaccordingly).
DORMA G-SR-EMF 2/BG
This push-side door co-ordi-nator includes an integralsmoke detector.A floating (volt-free) alarmcontact and connections forfurther detectors and externalmanual release devices arealso provided.Technical data for smokedetectors: see page 22.
DORMA G-SR-EMR 2/BG
The DORMA TS 93 G-SR-EMF 2/BG have beensuccessfully type-tested toEN 1155, ElectricallyPowered Hold-Open Devices.Certificates are available onrequest.
Power supply EMR: 230 vAC ± 10%
Max. output rating EMR: 9.8 W
Operating voltage EMF: 24 vDC ± 15%
Power input EMF 2: 2.8 W
Rated for continuous duty: 100%
Release force: adjustable
F Approval certification
The DORMA TS 93 G-SR-EMR 2/BG has been appro-ved by the German Institutefor Building Technology,Berlin, for use as a hold-openunit. Acceptance inspectionof the system is mandatory.
F Approval certificationTechnical data
Inactive leafActive leaf
= Door stop
approx.120°
approx.120°
approx.80°
approx.80°
20
DORMA G-SR/BGDORMA G-SR-EMF/BGDORMA G-SR-EMR/BG
Slide channel door co-ordinators
TS 93 GB
(45)
107
49
160
519
34max.5*
4328
81
30
34
max. 90
Standard door co-ordinator (G-SR/BG)Door co-ordinator with electro-mechanical hold-open (G-SR-EMF/BG)
max.5
4328
81
30
55
(45)49
34
519
160107
31
l 10 (230 V AC)
Door co-ordinator with integral smoke detector (G-SR-EMR/BG)
Inactive leafIn the case of unequal leaves,minimum width 600 mm
( ) = TS 93 EN 5-7
Inactive leaf
( ) = TS 93 EN 5-7
21TS 93 GB
l 8 (24 V DC)
492115
34
118(114)
176160
1500 – 2500*
1730
l 8 (24 V DC)
34
(114)
1800 – 2500*
30
17
492
160 176
118
444
250
95
2,5
Active leaf
Active leaf
* In the case of particularly large and heavy doors, we recommend that DORMA EM hold-open magnetsbe employed instead of the electro-mechanical hold-open unit.
22
DORMA RMZDORMA RM
Smoke detectors
TS 93 GB
Functions Smoke detector 2 2Release device 2 2Power supply unit 2 –
Smoke Scattered light principledetection (optical sensor) 2 2
Fixing Frame-mounted 2 –Ceiling-mounted – 2
Connection 2-wire – 2of other smoke switches 2 2detectors
Total installed load (max.) Dependsfor hold-open device on powerand other detectors in W 9,8 supply unit
Power input ofinternal detectors in W 1,2 0,6
LED Alarm 2 2indicators Standby 2 2
Maintenance due 2 –Contaminated condition 2 –
Input voltage 230 V AC 24 V DC± 10 % +15%, –10%
Output voltage 24 V DC 24 V DC
Detector operating voltage 24 V DC 24 V DC+15%, –10%
Input current (max.) with externalpower supply unit, in A – 2
Current input (max.) in mA 75 25
Floating (volt-free) change-over contactSafety extra-low voltage (SELV) 24 V AC 24 V AC
Reset automatic 2 2can be changed tomanual reset 2 2
Function Smoke extraction 2 2checking opening test – 2
Connection terminalsfor external manual release 2 2
Degree of protection IP 30 IP 20
Ambient temperature in °C –20, +40 –20, +50
Weight in kg 0,25 0,40
Dimensions Length 379 195in mm Overall depth 34 52
Height 30 53
2 yes – no
Data and features RMZ RMThe DORMA RMZ andDORMA RM smoke detectorsprovide the ideal comple-ment to the successful, ser-vice-proven DORMA TS 93range in preventive fire protection environments.They are designed in accor-dance with the latest codes
issued by the GermanInstitute for BuildingTechnology and ensure perfect interaction betweenall the devices employed forholding open fire and smokecheck doors – whatever thesituation.
The DORMA RMZ smokedetector provides a 24 V DCsupply for all the hold-opendevices connected to it. In the event of an alarm orpower failure, it de-energisesthe devices (release function).It has an automatic reset,which can be switched tomanual reset if required. A floating (volt-free) change-over contact and connec-tions for further detectors
and external manual releasedevices are also provided.The smoke detector is avai-lable in the RMZ versionwith stabilised power packor in the RMZ DCW versionwithout a power pack forintegration in buildingmanagement and controlsystems via a DCW bus and the DORMA TMS doormanagement system.
The DORMA RM smokedetector is designed as asmoke switch and actuates afloating (volt-free) change-over contact in the event ofan alarm or power failure. Itis also suitable as an add-onsmoke detector for the
DORMA TS 93 EMR andRMZ.A floating (volt-free) change-over contact and connec-tions for further detectorsand external manual releasedevices are also provided.
DORMA RMZ
DORMA RM
DORMA RMZ and DORMA RMunits have been approved bythe German Institute forBuilding Technology, Berlin,as hold-open release devices.
F Approval certification
378
34
357,5
30
53
52195
170
32
Ø 4,5
18 k
HT
N LPE
167 18 49
1012 23 1411
121 kΩ
EMF
230 V AC
RMZ
RM
12
1514
1114
1313
12
8
10
Ω
56
44
11
RM
12
1514
1114
1313
12
89
10
12
2x121 k Ω
Ω
56
44
11
18 k
23
11
7
12
11
923
7
2x121 k Ω
B 10 A
23TS 93 GB
DORMA RMZ + 2x RM
18 k
N LPE
167 18 49
1012 23 1411
121 kΩ230 V AC
RMZ
RM
12
1514
1114
1313
12
8
10
Ω
56
44
11
RM
12
1514
1114
1313
12
89
10
12
2x121 k Ω
Ω
56
44
11
18 k
23
11
7
12
11
923
7
2x121 k Ω
EMF
24 V DC
EMF
HT
B 10 A
G-SR-G/EMF G-SR-S/EMF
DORMA G-SR-EMR + 2x RM
Recommended cabling:I - (St) Y 2 x 2 x 0,6
RS-AM (Optional)
Recommended cabling:I - (St) Y 2 x 2 x 0,6
RS-AM (Optional)
24
Accessories Single doors
TS 93 GB
l 5
,5
10
5
23
442
428
30
10
5
442
428
40
l 5
,5
20 33
5
l 5
,5
10
33 40
428518
20
24 15
22,5
5
l 5
,5
10
33 40
428823
20
150
15
24
15
125
4
32Ø 5,5
15 25
15
257 142
442
142 7
428
4
32Ø 5,5
26
25
15
24
43 144 43144
428
518
24428
35
31
5410
11
EMF
NEM
R
28
23
16
5443
5615
16
16
6443
26
30 mm mounting backplatefor G-NFor fixing the slide channelto the door frame wheredirect fixing is not possible.
40 mm mounting backplatefor G-N, EMF, EMRFor fixing the slide channelto the door frame wheredirect fixing is not possible.
Angle bracket for G-NFor push-side fixing of theslide channel to door frameswith a deep reveal.
Angle bracket for G-EMFFor push-side fixing of theslide channel to door frameswith a deep reveal.
25TS 93 GB
10
500
5
l 5
,5
33
470
600
20
10
3320
40
40
24
250
1832
88 500
33 40
10
246
4725
l 5
,5
492
613,5
10
24
40
40
10
259,5
499
519613,5
24
3310
33 10
250
1170
96,5 500
5
l 5
,5
2626
4
32
l 5,5
15
15
250 250565,5613,5
519
25
25
492
24
3535
250
1170250
585
823,596,5
1665
1342
5423
1628
2643
64
16
40 mm mounting backplatefor G-SRFor fixing the slide channelsto the door frame wheredirect fixing is not possible.
40 mm mounting backplatefor G-SR/BGFor fixing the slide channelsto the door frame wheredirect fixing is not possible.
Angle bracket for G-SR/BGFor fixing the slide channelsto door frames with a deepreveal.
Accessories Double doors
26
Accessories G-SR pivot block
TS 93 GB
If the DORMA G-SR door co-ordinator is to operateindependently of the TS 93door closer, for example, in combination with the ED 200 automatic swingdoor operator, the connectionbetween the door co-ordinator and the door leafis provided by means of G-SR pivot blocks.
F Approval certification
The DORMA G-SR door co-ordinator with pivot blockshas been approved by e.g.the State Material TestingAuthority, Dortmund/Germany, for use on doublefire and smoke doors.
B
142
120 110
66
49
13
29
470
43
3
96
29
13
34
37
133
106
52
DORMA ED 200automatic swingdoor operator withDORMA G-SR door co-ordinator and G-SR pivot block
Fixing dimension BB (mm) Door width (mm)88 1220 – 135034 more than 1350
G-SR pivot block for door co-ordinator
27TS 93 GB
Hold-open systems Regulations/Information
The use of hold-open devicesmay be subject to certainconditions. These usuallydeal particularly with therelevant acceptance, routineinspection and maintenancerequirements.
The information given onthis page is designed toinform all relevant personsof the most important measures to be implementedin order to ensure best practice governing the oper-ation of hold-open systems.
Further details can be foundin the following documents:
– Guidelines for hold-opensystems, published by the German Institute forBuilding Technology,Berlin.
– Building Regulations,England and Wales
– Relevant regulations forScotland and N. Ireland
– EN 1155
1 General
2 Commissioning
3 Routine inspection
1.1 In respect of doors etc.which are held open byhold-open systems, the areaneeded for closure must bekept permanently free ofobstructions. This areashould be clearly indicatedby means of lettering, floor markings or similar. If necessary, structural measures may need to betaken in order to ensure thatwiring/ducting, stored goods
or structural components(e.g. false ceilings or othercomponents) do not falldown into the area to bekept clear.
1.2 As far as possible,smoke detectors should beused for hold-open systems.Smoke detectors should beused for hold-open systemsfor doors etc. in emergencyexits and escape routes.
1.3 All hold-open devicesshould be able to be releasedmanually without their operational readiness beingadversely affected. Door closers with electro-magnetichold-open systems can bereleased by pressing lightlyon the door leaf. If hold-open magnets or free-swingdoor closers are used, therelease function is triggeredby pressing a switch. The
switch must be located inthe immediate proximity ofthe door and must not becovered when the door isheld open.
2.1 After the system hasbeen fitted ready for use on-site, it should be commissioned to check thatits operation is problem-freeand that its installationcomplies with all relevantregulations. The commission-
ing should only be performedby qualified technical personnel.
3.1 The operator shouldkeep the hold-open systemin a permanently fit state for use and must inspect itat least once a month toensure its functional integrity.
3.2 In addition, it is the responsibility of the operatorto ensure that all devices arechecked and maintained/serviced to ensure their combined functional integrity,this to be performed at leastonce a year, unless a shorter
time period is stipulated inthe national regulations. Thisinspection and servicingactivity should only be carried out by a specialist orsuitably qualified person.
3.3 The scope, result and time of the routine inspections should be recorded, and these recordsshould be retained by theoperator.
28
Range of equipment and optional accessories
Single doors
TS 93 GB
Product description: see page 6 7 24 24
Hold-open device TS 93 B TS 93 G 30 mm mounting 40 mm mountingbackplate backplate
Smoke detector zu G-N zu G-N
2 – 5 2 – 5y 430200xx y 430300xx
5 – 7 5 – 7y 435200xx y 435300xx 644000xx 644100xx
G-N xX 640100xx y y
8 # #xX xX
G-EMF xX 640200xx y y
10 # #xX xX
G-EMR xX 640300xx y y
12 # #xX xX
G-EMR DCW xX 640303xx y y
12 # #xX xX
29TS 93 GB
24 24 24 24 8 8
# # #
# #
#
#
40 mm mounting 40 mm mounting Angle bracket Angle bracket Cushioned Add-on hold-openbackplate for backplate for for G-N for G-EMF limit stay set unit for G-NG-EMF G-EMR for G-N
644200xx 644500xx 644300xx 644400xx 35800093 18570000
Product description: see page 22
Smoke detector system
RMZ648000xx
RMZ DCW648003xx
RM648200xx
Also available in matching“Design” finishes:
y = Closer separate
Y = Slide channel assembly separate
# = Optional accessory
Colour x xSilver 01White (like RAL 9016) 11White (like RAL 9010) 10Special colour 09
Stainless steel 04Polished brass 05
“Design” refers to the surface finish of the products
30
Range of equipment and optional accessories
Double doors
TS 93 GB
Product description: see page 6 7 25 25
Hold-open device TS 93 B TS 93 G Mounting Mountingbackplate backplate
Smoke detector for G-SR for G-SR/BG
2 – 5y 430200xx
5 – 7 2 – 5Active leaf Inactive leaf y 435200xx y 430300xx 644800xx 644900xx
Door width Modelin mm
1220-1350 G-SR…VK1350-2500 G-SR…V2500-3200 G-SR…VL
G-SR xX VK 641010xx 2xV 641020xx y
VL 641030xx 14 #xX
G-SR-EMF 1 xX VK 641110xx 2xV 641120xx y
VL 641130xx 14 #xX
G-SR-EMF 2 xX VK 641310xx 2xV 641320xx y
VL 641330xx 14 #xX
G-SR-EMF 1G xX VK 641210xx 2xV 641220xx y
VL 641230xx 14 #xX
G-SR-EMR 1 xX V 642150xx 2xVL 642160xx y
14 #xX
G-SR-EMR 2 xX V 642350xx 2xVL 642360xx y
14 #xX
G-SR-EMR 2 DCW xX V 642353xx 2xVL 642363xx y
14 #xX
G-SR-EMR 1G xX V 642250xx 2xVL 642260xx y
14 #xX
G-SR/BG xX V 641440xx 2xy
14 #xX
G-SR-EMF 2/BG xX V 641740xx 2xy
14 #xX
G-SR-EMR 2/BG xX V 642770xx 2xy
14 #xX
G-SR-EMR 2 DCW/BG xX V 642773xx 2xy
14 #xX
31TS 93 GB
25 26 8
# #
# # #
Angle bracket Pivot block Cushionedfor G-SR/BG limit stay
644700xx 645000xx 18020000
Product description: see page 22
Smoke detector system
RMZ648000xx
RMZ DCW648003xx
RM648200xx
1) Also available in matching1 )“Design” finishes:
y = Closer separate
Y = Slide channel assembly separate
# = Optional accessory
Colour x xSilver 01White (like RAL 9016) 11Special colour 09
Stainless steel 04“Design” refers to the surface finish of the products
32
Specification text Single doors
TS 93 GB
DORMA TS 93 N
Y Size EN 2-5Y Size EN 5-7Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Doorleaf fixing on the pull side,transom fixing on the push side. Closing speed,latching speed, hydraulicallycontrolled backcheck and delayed action conveniently
adjustable at valves acces-sible from the front.Mounting bracket with uni-versal fixing hole system.Non-handed. Height-adjusta-ble slide channel.
Optional: Y With retrofittable cushioned limit stay for integration in the standardslide channel.
Y With retrofittable mecha-nical hold-open unit (RF),hold-open point adjustablebetween 75° and 150°.
Use of mechanical hold-open units is not permittedon fire and smoke checkdoors.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. toRAL)
MakeDORMA TS 93 N, EN 2-5DORMA TS 93 N, EN 5-7DORMA TS 93 RF, EN 2-5DORMA TS 93 RF, EN 5-7
DORMA TS 93G N
Y Size EN 2-5Y Size EN 5-7Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Doorleaf fixing on the push side,transom fixing on the pull side. Closing speed, latching speed, hydraulicallycontrolled backcheck anddelayed action conveniently
adjustable at valves acces-sible from the front.Mounting bracket with univer-sal fixing hole system. Non-handed. Height-adjustableslide channel.
Optional: Y With retrofittable cushioned limit stay for integration in the standardslide channel.
Y With retrofittable mecha-nical hold-open unit (RF),hold-open point adjustablebetween 75° and 150°.
Use of mechanical hold-open units is not permittedon fire and smoke checkdoors.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA TS 93G N, EN 2-5DORMA TS 93G N, EN 5-7DORMA TS 93G RF, EN 2-5DORMA TS 93G RF, EN 5-7
DORMA TS 93 EMF
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Pull-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves acces-sible from the front.
Mounting bracket with universal fixing hole system.Non-handed.Slide channel assembly withintegral electro-mechanicalhold-open, 24 V DC, confor-ming to EN 1155.Hold-open point (80° - 120°)and pull-off force infinitelyvariable. One-piece cover.Overall height 30 mm.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for usein hold-open systems.Acceptance inspection ofthe system is mandatory.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA TS 93 EMF, EN 2-5
DORMA TS 93G EMF
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Push-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves acces-sible from the front.
Mounting bracket with universal fixing hole system.Non-handed.Slide channel assembly withintegral electro-mechanicalhold-open, 24 V DC, conforming to EN 1155.Hold-open point (80° - 120°)and pull-off force infinitelyvariable. One-piece cover.Overall height 30 mm.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for usein hold-open systems.Acceptance inspection ofthe system is mandatory.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA TS 93G EMF, EN 2-5
33TS 93 GB
DORMA TS 93 EMR
Y Size EN 2-5Cam action door closer conforming to EN 1154,carries the CE mark, Conturdesign, with rapidly decreasing opening torque/force. Pull-side fixing. Closingspeed, latching speed,hydraulically controlled back-check and delayed actionconveniently adjustable atvalves accessible from thefront. Mounting bracket withuniversal fixing hole system.Non-handed.
Slide channel assembly withintegral smoke detector featuring standby and main-tenance indicators and elec-tro-mechanical hold-open,24 V DC, conforming to EN 1155. Hold-open point(80° - 120°) and pull-offforce infinitely variable. Afloating (volt-free) alarmcontact and connections forfurther detectors and exter-nal manual release devicesare provided. One-piececover. Overall height 30 mm.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for useas a hold-open unit.Acceptance inspection ofthe system is mandatory.
ModelY TS 93 EMR with integra-ted power pack.Power supply 230 V AC,operating voltage 24 V DCY TS 93 EMR DCWSmoke detector withoutpower pack for connectionto DCW bus.
Y Optional integral alarmmodule adding an audiblesignal to the visual indicator.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA TS 93 EMR, EN 2-5DORMA TS 93 EMR DCW,EN 2-5
DORMA TS 93G EMR
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Push-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-ble from the front. Mountingbracket with universal fixinghole system. Non-handed. Slide channel assembly withintegral smoke detector fea-
turing standby and mainte-nance indicators, powerpack and electro-mechanicalhold-open, 24 V DC, confor-ming to EN 1155. Hold-open point (80° - 120°)and pull-off force infinitelyvariable. A floating (volt-free)alarm contact and connec-tions for further detectorsand external manual releasedevices are provided. One-piece cover. Overallheight 30 mm.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for useas a hold-open unit.Acceptance inspection ofthe system is mandatory.
ModelY TS 93 EMR with integrated power pack.Power supply 230 V AC,operating voltage 24 V DCY TS 93 EMR DCWSmoke detector withoutpower pack for connectionto DCW bus.
Y Optional integral alarmmodule adding an audiblesignal to the visual indicator.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA TS 93G EMR, EN 2-5DORMA TS 93G EMR DCW,EN 2-5
DORMA RMZ
Smoke detector, Conturdesign, with standby andmaintenance indicators,integral power pack andoptical smoke sensor fortransom/lintel fixing. For activation of DORMAhold-open devices.A floating (volt-free) alarmcontact and connections forfurther detectors and exter-nal manual release devicesare provided.
Can be switched to manualreset. One-piece cover.Overall height 30 mm.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for usein a hold-open system.Acceptance inspection ofthe system is mandatory.
ModelY RMZ with integratedpower pack.Power supply 230 V AC,operating voltage 24 V DCY RMZ DCWSmoke detector withoutpower pack for connectionto DCW bus. Y Optional integral alarmmodule adding an audiblesignal to the visual indicator.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA RMZDORMA RMZ DCW
DORMA RM
Universal, non-directionaloptical smoke detector, 24 V DC, for transom, linteland ceiling fixing. For use asa smoke switch and moni-toring unit for hold-opendevices. A floating (volt-free)alarm contact and connec-
tions for external manualrelease device are provided.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for usein a hold-open system, andapproved by the VdS,Cologne, to EN 54, Part 7.Acceptance inspection ofthe system is mandatory.
ColourY silverwhite, sim. to RAL Y 9010
Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)
MakeDORMA RM
34
Specification text Double doors
TS 93 GB
DORMA TS 93 GSR
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Pull-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-
ble from the front. Mountingbracket with universal fixinghole system. Non-handed. Slide channel assembly withintegrated mechanical doorco-ordinator, conforming to EN 1158. This systemoperates independently ofthe door closer hydraulicsusing a push rod clampingsystem with an overload
release and one-piece cover.Overall height 30 mm.Non-handed.Approved by the GermanInstitute for BuildingTechnology, Berlin, for useon fire and smoke checkdoors.
ColourY silverwhite, sim. to RAL Y 9016Y stainless steelY special colour (sim. to RAL)
MakeDORMA TS 93 GSR
DORMA TS 93 GSR-EMF
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Pull-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-ble from the front. Mountingbracket with universal fixinghole system. Non-handed. Slide channel assembly with integrated mechanicaldoor co-ordinator, confor-ming to EN 1158. With electro-mechanical
hold-open, 24 V DC, confor-ming to EN 1155.Hold-open point (80° - 130°)and pull-off force infinitelyvariable. This system opera-tes independently of thedoor closer hydraulics usinga push rod clamping systemwith an overload release andone-piece cover. Overallheight 30 mm. Non-handed.Approved by the GermanInstitute for BuildingTechnology, Berlin, for usein hold-open systems.Acceptance inspection ofthe system is mandatory.
ModelY TS 93 GSR-EMF 1With electro-mechanicalhold-open for the inactiveleaf
Y TS 93 GSR-EMF 2With electro-mechanicalhold-open for the active andinactive leaf
Y TS 93 GSR-EMF 1G With electro-mechanicalhold-open for the active leaf
ColourY silverwhite, sim. to RAL Y 9016Y stainless steelY special colour (sim. to RAL)
MakeDORMA TS 93 GSR-EMF1DORMA TS 93 GSR-EMF 2DORMA TS 93 GSR-EMF 1G
DORMA TS 93 GSR-EMR
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Pull-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-ble from the front. Mountingbracket with universal fixinghole system. Non-handed. Smoke detector with stand-by and maintenance indica-tors, fully integrated in the door co-ordinator body.A floating (volt-free) alarmcontact and connections forfurther detectors and exter-nal manual release devicesare provided. Power supply230 V AC, operating voltage24 V DC.
Slide channel assembly withintegrated mechanical doorco-ordinator, conforming toEN 1158. With electro-mechanical hold-open, 24 V DC, conforming to EN 1155. Hold-open point(80° - 130°) and pull-offforce infinitely variable. Thissystem operates independ-ently of the door closerhydraulics using a push rodclamping system with anoverload release and one-piece cover. Overall height30 mm. Non-handed.Approved by the GermanInstitute for BuildingTechnology, Berlin, for useas a hold-open unit.Acceptance inspection ofthe system is mandatory.
ModelY TS 93 GSR-EMR 1With electro-mechanicalhold-open for the inactiveleaf
Y TS 93 GSR-EMR 2With electro-mechanicalhold-open for the active andinactive leaf
Y TS 93 GSR-EMR 1G With electro-mechanicalhold-open for the active leaf
Y TS 93 GSR-EMR 2 DCWSmoke detector withoutpower pack for connectionto DCW bus. With electro-mechanical hold-open forthe active and inactive leaf.
ColourY silverwhite, sim. to RAL Y 9016Y stainless steelY special colour (sim. to RAL)
MakeDORMA TS 93 GSR-EMR1DORMA TS 93 GSR-EMR 2DORMA TS 93 GSR-EMR 1GDORMA TS 93 GSR-EMR 2DCW
35TS 93 GB
DORMA TS 93 GSR/BG
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Push-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-
ble from the front. Mountingbracket with universal fixinghole system. Non-handed. Slide channel assembly withintegrated mechanical doorco-ordinator, conforming toEN 1158. This system ope-rates independently of thedoor closer hydraulics usinga push rod clamping systemwith an overload release
and one-piece cover. Overallheight 30 mm.Non-handed.General building approvalissued by the GermanInstitute for BuildingTechnology, Berlin, for useon fire and smoke checkdoors.
ColourY silverwhite, sim. to RAL Y 9016Y stainless steelY special colour (sim. to RAL)
MakeDORMA TS 93 GSR/BG
DORMA TS 93 GSR-EMF 2/BG
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Push-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-ble from the front. Mountingbracket with universal fixinghole system. Non-handed.Slide channel assembly withintegrated mechanical door
co-ordinator, conforming toEN 1158. With electro-mechanical hold-open forthe active and inactive leaf,24 V DC, conforming to EN 1155.
Hold-open point (80° - 120°)and pull-off force infinitelyvariable. This system opera-tes independently of thedoor closer hydraulics usinga push rod clamping systemwith an overload release andone-piece cover. Overallheight 30 mm. Non-handed.
Approved by the GermanInstitute for BuildingTechnology, Berlin, for usein hold-open systems.Acceptance inspection ofthe system is mandatory.
ColourY silverwhite, sim. to RAL Y 9016Y stainless steelY special colour (sim. to RAL)
MakeDORMA TS 93 GSR-EMF2/BG
DORMA TS 93 GSR-EMR 2/BG
Y Size EN 2-5Cam action door closer con-forming to EN 1154, carriesthe CE mark, Contur design,with rapidly decreasing opening torque/force. Push-side fixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessi-ble from the front. Mountingbracket with universal fixinghole system. Non-handed.Smoke detector with stand-by and maintenance indica-tors, fully integrated in the door co-ordinator body.A floating (volt-free) alarmcontact and connections forfurther detectors and exter-nal manual release devicesare provided. Power supply230 V AC, operating voltage24 V DC.
Slide channel assembly withintegrated mechanical doorco-ordinator, conforming toEN 1158. With electro-mechanical hold-open forthe active and inactive leaf,24 V DC, conforming to EN 1155. Hold-open point(80° - 130°) and pull-offforce infinitely variable. Thissystem operates independ-ently of the door closerhydraulics using a push rodclamping system with anoverload release and one-piece cover. Overall height30 mm. Non-handed. Approved by the GermanInstitute for BuildingTechnology, Berlin, for useas a hold-open unit.Acceptance inspection ofthe system is mandatory.
ModelY TS 93 GSR-EMR 2/BG With integrated electro-mechanical hold-open forthe active and inactive leaf.
Y TS 93 GSR-EMR 2 DCW/BGSmoke detector withoutpower pack for connectionto a DCW bus. With inte-grated electro-mechanicalhold-open for the active andinactive leaf.
ColourY silverwhite, sim. to RAL Y 9016Y stainless steelY special colour (sim. to RAL)
MakeDORMA TS 93 GSR-EMR 2/BGDORMA TS 93 GSR-EMR 2DCW/BG
4021226316511
WN
053
11
55
15
32
, 0
3/0
7,
TS 9
3 C
ontu
r, G
B,
x. D
D.
xx/0
7·
Sub
ject
to
chan
ge w
itho
ut n
otic
e
Door Control Division worldwide
Central EuropeDORMA GmbH + Co. KGBreckerfelder Str. 42–48D-58256 EnnepetalTel. +49 2333/793-0Fax +49 2333/793-495
AustraliaDORMA Door Controls Pty. Ltd.52 Abbott RoadHallam/Victoria 3803AustraliaTel. +61 3/97 96 35 55Fax +61 3/97 96 39 55
ChinaDORMA Door Controls (Suzhou)Co. Ltd.No. 9, Hong Feng RoadSuzhou Singapore Industrial ParkSuzhou, 215021P. R. of ChinaTel. +86 512/67612481Fax +86 512/67614582
DORMA Door Controls Pte. Ltd.Room 701, Technology Plaza651 King’s RoadNorth PointHong KongTel. +825/250 34632Fax +825/288 75370
Emerging MarketsDORMA GmbH + Co. KGBreckerfelder Str. 42–48D-58256 EnnepetalTel. +49 23 33/7 93-0Fax +49 23 33/793-495
DORMA Door Controls (Pty.) Ltd.Kings Court, 4A Mineral CrescentZA-2000 Crown/GautengSouth AfricaTel. +27 11/8 30 02 80Fax +27 11/8 30 02 91
Far EastDORMA Far East Pte. Ltd.No. 31 Gul Lane,Singapore 629425Tel. +65 6268/7633Fax +65 6265/7914
FranceDORMA France S.A.S.Europarc42, rue Eugène DupuisF-94046 CréteilTel. +33 1/41 94 24 00Fax +33 1/41 94 24 01
GulfDORMA Gulf Door Controls FZEJebel Ali Free Zone,Roundabout 8, Unit VC 02Dubai, United Arab EmiratesTel. +971 48/83 90 14Fax +971 48/83 90 15
North AmericaDORMA Architectural HardwareDORMA Drive, Drawer ACReamstown, PA 17567Tel. +1-800-523-8483Fax +1-800-274-9724
ScanbaltDORMA Danmark A/SSindalvej 6 – 8DK-2610 RødovreTel. +45 44/54 30 00Fax +45 44/54 30 01
South AmericaDORMA Sistemas de Controlespara Portas Ltda.Av. Piracema, 1400Centro Empresarial TamboreCEP 06400 Barueri/São Paulo, BrasilTel. +55 11/41 91 32 44Fax +55 11/41 91 21 93
South-East EuropeDORMA AUSTRIA GmbHPebering Strass 22A-5301 EugendorfTel. +43 62 25/2 84 88Fax +43 62 25/2 84 91
South EuropeDORMA Italiana S.r.l.Via. A. Canova 44/46I-20035 Lissone (MI)Tel. +39 039/24 40 31Fax +39 039/24 40 33 10
DORMA Ibérica, S.A.Camino San Martin de la Vega, 4E-28500 Arganda del Rey (Madrid)Tel. +34 91/8 75 78 50Fax +34 91/8 75 78 81
UK/IrelandDORMA UK Ltd.Door Controls DivisionWilbury WayHitchinHertfordshire SG4 0ABTel. +44 14 62/4776 00Fax +44 14 62/4776 01
www.dorma.com
Door Control
Automatic
Glass Fittings and Accessories
Security/Time and Access (STA)
Movable Walls