32
Cam action door closer system TS 93 DORMA

Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

  • Upload
    others

  • View
    20

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

Cam action door closer system

TS 93DORMA

Page 2: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

2

DORMA TS 93

Force profileDORMA TS 93(Spring strength: EN 5)

Opening forceClosing force

DORMA TS 93 – Cam action door closer system

More compact,lighter andmore elegant

DORMA has set new standardswith its TS 93 cam-actiondoor closer system. Offeringfurther technical refinementsand enhanced sophistication,it constitutes an even moreimpressive specification –thanks to

2 smaller dimensions 2 concealed fixings 2 height-adjustable standard

(N) slide channel 2 30 mm high EMF, EMR

and GSR slide channels2 mechanically secured

cover2 delayed action feature as

standard2 simple, fast installation2 low weight

Rapidly decreasing opening forceUnlike rack and pinionslide-channel door closers,the DORMA TS 93 systemwith its the linear drivemechanism and heart-shaped cam ensures thatthe resistance encounteredwhen opening the doordecreases almost instantlywith the opening action. So even children, the elderlyand handicapped peoplehave no problem in openingthe door.

60

50

40

30

20

10

00° 30° 60° 90° 120° 150° 180°

Nm

TS 93 GB

Page 3: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

3

PageFeatures and functions 4

DORMA TS 93 BDoor closer for pull-side door leaf fixing/push-side transom fixing 6

DORMA TS 93 G Door closer for push-side door leaf fixing/pull-side transom fixing 7

DORMA G 93 NStandard slide channel design 8

DORMA RF Hold-open unit 8

DORMA G 93 EMF Slide channel with electro-mechanical hold-open 10

DORMA G 93 EMR Slide channel with electro-mechanicalhold-open and integral smoke detector 12

DORMA G 93 GSRDoor co-ordinator slide channel for pull-side fixing 14

DORMA G 93 GSR-EMFDoor co-ordinator slide channel with integralelectro-mechanical hold-open for pull-side fixing 15

DORMA G 93 GSR/BGDoor co-ordinator slide channel for push-side fixing 18

DORMA G 93 GSR-EMF/BGDoor co-ordinator slide channel with integralelectro-mechanical hold-open for push-side fixing 19

DORMA RMZ-K/S, DORMA RMFrame-mounted and ceiling-mounted smoke detectors 22

Accessories 24

Hold-open systemsRegulations and information 27

Range of equipment and optional accessoriesSingle doors 28

Range of equipment and optional accessoriesDouble doors 30

Contents

Further information, specification textsAdditional information e.g.specification texts, drawings,installation instructions onmany products can beaccessed via electronicmedia (Internet, CD ROM,floppy disk). The codes beside the computer symbol

are the search terms.The specification texts arealso available in printedform.

TS 93 GB

Page 4: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

DORMA TS 93 Cam action door closer system

4

EN ENVariable closing force Spring strength 2–5 5–7Standard doors2) Up to 1250 mm 2 –

Up to 1600 mm – 2External doors, Up to 1250 mm 2 –outward opening2) Up to 1600 mm – 2To EN 1154 A, Up to 1250 mm 2 –for fire and smoke doors2) Up to 1600 mm – 2Non-handed 2 2Arm assembly type Standard – –

Slide channel 2 2Closing force variable by means of adjustment screw 2 2Closing speed adjustable by valve 2 2Latching speed at arm – –adjustable at valve 2 2Backcheck (BC/ÖD) self-

adjusting – –adjustableat valve 2 2

Delayed action (DC/SV)adjustable at valve 2 2Hold-open " "Weight in kg 3.5 5.2Dimensions in mm Length (L) 275 285

Overall depth (B) 253 262Height (H) 260 271

2 yes – no " option

Data and features TS 93 B/G1)For every door and application –the best in aesthetics and functionWith its TS 93, DORMA hasdeveloped an aestheticallyelegant generation of doorclosers offering unbeatableease of use. The TS 93series comprises a modularsystem which enables just afew door closer models to becombined with a number ofdifferent slide channels tomeet virtually every conceiv-able functional requirement.Doors of varying designs canbe equipped for a wide rangeof different applications.

Advanced, computer-aideddesign and manufacturingwith comprehensive qualityassurance provide a securebasis for the outstandingreliability and long servicelife of this product.

Quality-assured manufacture to ISO 9001,

EN 29001,BS 5750.

Certified and verified byBSI Quality AssuranceReg.-No. Q 6423, FM 10756

... for the trade2 Low inventory costs and

reduced stocking require-ments thanks to stream-lined modular system andseparate packaging of closer body and slidechannel assemblies.

2 Practical solutions tosatisfy special requirementsand fixing situations.

... for the installer2 Suitable for all fixing

positions.2 Universal fixing hole

pattern for perfect alignment every time.

2 Same fixing hole patternfor both clockwise-closing(ISO 5) and anticlockwise-closing (ISO 6) doors.

2 Simple spring strengthadjustment – in just amatter of seconds with aratchet wrench.

... for the specifier/architect2 Harmony and compatibility

with the architecturalenvironment.

2 All models feature thesame, fully matching"Softline" styling.

2 Available in a wide rangeof colours and finishes.

... for the user2 The perfect combination

of aesthetic elegance,technical refinement andaffordability.

2 Wide spectrum of user-friendly and safety functions.

2 Easy opening action, fullycontrolled closing.

500

428

16

43

1611

8

56

160

275

505428

91

53

31

31

6291

160

285

56

1643

1611

3838

8

2071

109

97

2060

1) B = Standard model for pull-side door leaf fixing/push-side transom fixingG = Special model for push-side door leaf fixing/pull-side transom fixing.

2) For applications involving particularly heavy or wide doors, and doors which have to close against wind resistance, the next highest door closer size should be selected, or the closing force adjusted to a higher setting.

DORMA TS 93,Size EN 2 – 5

DORMA TS 93,Size EN 5 – 7

Plus points...

TS 93 GB

Page 5: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

5

12

4

3

Standard mounting backplate with universalfixing hole systemThis mounting backplate withits universal hole system,including hole pattern tosupplementary sheet 1 ofDIN EN 1154 A, ensuresideal fixing whatever theconditions and irrespectiveof the door type. The fixinghole patterns are the same for both sizes of theDORMA TS 93. Additionalmounting plates/brackets are no longer required.Alignment dowels on themounting backplate facilitatelocation of the closer body.

BackcheckThe backcheck feature ensures the safe decelerationand restraint of a door whichhas been flung open orcaught by a gust of wind.This effectively reduces the danger of the door andadjacent wall being damaged.

Delayed actionThe delayed action featureretards the closing cyclebetween 120° and 70°(approximate values for pull-side door leaf fixing). Theextra time allowed for passage through the doorwaycan be essential for peoplewith luggage or bulky items:mothers with prams, personnel with tea trolleys,post trolleys, hospital beds,etc.; and also for disabledpeople.

120°70°

4

3

2

1

70°3

120°70°

4

1 Fully controlled closingaction with adjustablespeed

2 Adjustable latch speed3 Adjustable backcheck4 Adjustable delayed action

3 Adjustable backcheck

4 Adjustable delayed action

TS 93 GB

Page 6: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

6

DORMA TS 93 Gleitschienen-Türschließersystem

DORMA TS 93 B Door closers

max. 164

2 65

16

143 428

33

4

142 160884

(80)

max. 30

154

38

1

160 1428 84(80)

4

143428

Door leaf fixing (standardarrangement) of the DORMATS 93 B on the pull side.Structural conditions permit-ting, an opening angle of180° is possible with thisfixing method. In mostcases, a wall recess mayhave to be provided for thedoor closer.Example: Anticlockwise-closing (ISO 6) door; mirrored arrangements applyto clockwise-closing (ISO 5)doors.

The DORMA TS 93 B isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120.

Cam-action overhead doorcloser tested to EN 1154,CERTIFIRE approved,Softline design, with rapidlydecreasing openingtorque/force. Closing speed,latching speed, backcheckand delayed action adjustableat the valve. Mounting back-plate with universal fixinghole pattern. Non-handed,with slide channel... (see pages 8 – 21)

ModelY for pull-side door leaffixingSizeY EN 2 – 5Y EN 5 – 7ColourY silver Y dark brownwhite,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )Make DORMA TS 93 B

TS93N/2-5TS93N/5-7

Transom fixing (overheadframe fixing) of the DORMATS 93 B on the push side.Backcheck and delayedaction non-operative with thisfixing arrangement. The dooropening angle is limited toapprox. 120° to 145°,depending on the structuralconditions. In order to pre-vent damage to the wall anddoor, a door stop should beinstalled to limit the maxi-mum angle of door opening.Example: Anticlockwise-closing (ISO 6) door; mirroredarrangements apply to clock-wise-closing (ISO 5) doors.

The DORMA TS 93 B isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120.

Cam-action overhead doorcloser tested to EN 1154,CERTIFIRE approved,Softline design, with rapidlydecreasing openingtorque/force. Closing speedand latching speed adjustableat the valve. Mounting back-plate with universal fixinghole system. Non-handed,with slide channel... (see pages 8 – 21).

ModelY for push-side transomfixingSizeY EN 2 – 5Y EN 5 – 7ColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )Make DORMA TS 93 B

TS93N/2-5TS93N/5-7

( ) = TS 93 5–7

( ) = TS 93 5–7

Push side door leaf fixing

TS 93 GB

Pull-side door leaf fixing

F Approval certification Specification text

F Approval certification Specification text

Page 7: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

DORMA TS 93 G

7

max. 264

32

8

81

428 143

16043

107

17

(45)49

max. 3

2843

81

142 160884(80)

143

17

428

Door leaf fixing (standardinstallation) of the DORMATS 93 G on the push side. The door opening angle islimited to approx. 120° to145°, depending on thestructural conditions. Inorder to prevent damage tothe wall and door, a doorstop should be installed tolimit the maximum angle of door opening.A door stop must be installedfor fire and smoke doors.

The DORMA TS 93 B isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120.

Cam-action overhead doorcloser tested to EN 1154,CERTIFIRE approved,Softline design, with rapidlydecreasing openingtorque/force. Closing speed,latching speed, backcheckand delayed action adjustableat the valve. Mounting back-plate with universal fixinghole system. Non-handed,with slide channel... (see pages 8 – 21)

ModelY for push-side door leaffixingSizeY EN 2 – 5Y EN 5 – 7ColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )Make DORMA TS 93 G

TS93G/N/2-5TS93G/N/5-7

Transom fixing (overheadframe fixing) of the DORMATS 93 G on the pull side.Structural conditions permitting, an opening angle of 180° is possiblewith this fixing method.Example: Anticlockwise-closing (ISO 6) door; mirrored arrangements applyto clockwise-closing (ISO 5)doors.

The DORMA TS 93 B isCERTIFIRE approved(Certificate No. CF 119) fordoor types ITT 120.

Cam-action overhead doorcloser tested to EN 1154,CERTIFIRE approved,Softline design, with rapidlydecreasing openingtorque/force. Closing speed,latching speed, backcheckand delayed action adjustableat the valve. Mounting back-plate with universal fixinghole system. Non-handed,with slide channel... (see pages 8 – 21)

ModelY for pull-side transomfixingSizeY EN 2 – 5Y EN 5 – 7ColourY silver Y dark brownwhite,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )Make DORMA TS 93 G

TS93G/N/2-5TS93G/N/5-7

( ) = TS 93 5–7

( ) = TS 93 5–7

TS 93 GB

F Approval certification Specification text

Pull-side transom fixing

F Approval certification

Specification text

Push-side door leaf fixing

Door closers

Example: Anticlockwise-closing (ISO 6) door; mirroredarrangements apply to clock-wise-closing (ISO 5) doors.

Page 8: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

8

DORMA G 93 N, RF Slide channels

20 ±2,5

31

441

428

±2,5

150°

75°

Hold-open range

max. 120° 80°

Cushioned limit stay

The DORMA G 93 N slidechannel assembly incorpo-rates the slide arm, slidechannel, slide block, fixingadapters, screws and endcaps. The DORMA G 93 Nslide channel assembly isnon-handed and can becombined with all door closermodels.

Thanks to oblong holes inthe fixing adapters, the slidechannel can be effectivelyadjusted to variations in the drill hole pattern whilekeeping the gap betweendoor closer body and slidechannel aligned and parallel.

The DORMA G 93 N hasbeen successfully type-tested to EN 1154 in conjunction with theDORMA TS 93.Certificates are available onrequest.

DORMA TS 93 ... door closer(see pages 6 and 7) with slidechannel G 93 N, standardmodel.

ColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y stainless steelY polished chromeY polished brassY special colour (like RAL )

Make DORMA TS 93 N

TS93N/2-5TS93N/5-7TS93G/N/2-5TS93G/N/5-7

The DORMA RF hold-openunit enables doors to besecurely held without anyfall-back at precisely therequired position up to anopening angle of approx.150°. The hold-open func-tion can be easily switchedon and off by the user, and

the release force can beadjusted to the door typeconcerned. The DORMA RFmechanism is non-handedand has been specificallydesigned for retrofitting tothe N type standard slidechannel.

The suitability of the hold-open unit may be limitedwhere the closer unit isfixed to the door leaf on thepush side, in combinationwith outward-opening doors,and also in the case oflarge, heavy doors.

Not for fire and smoke doors.

Y DORMA RF hold-open unit

TS93RF/2-5TS93G/RF/2-5

Accessories for the DORMAG 93 N, RF slide channel:Cushioned limit stay forretrofitting to the slide channel. Adjustable between80° and max. 120°.

The cushioned limit stay prevents the door from hitting the adjacent wallwhen opened normally.

The cushioned limit stay is not a heavy-duty protective device and inmany applications cannotsubstitute for a door stop.

Y Cushioned limit stay

TS 93 GB

F Approval certification Specification text

Accessories

Accessories

Standard model

Hold-open unit

Cushioned limit stay

Page 9: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

9

max. 30

154

38

1

428 143

4

160 1428 84(80)

max. 16

42 6

51

6

143 428

33

4

84(80)

1428

160

max. 3

28

81

43

max. 26

43

81

28

428 143

16043

107

17

49(45)

17

142 160

884(80)

143 428

DORMA TS 93 B door closer with DORMA G 93 N slide channel assembly, door leaf fixing on the pull side and transom fixing on the push side.Examples: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.

DORMA TS 93 G door closer with DORMA G 93 N slide channel assembly,door leaf fixing on the push side and transom fixing on the pull side.Examples: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.

( ) = TS 93 5 – 7

The door opening angle is limited to approx. 120° – 145° depending on the structural conditions. Use a cushioned limit stay or install a door stop.

( ) = TS 93 5 – 7

The door opening angle is limited to approx. 120° – 145° depending on the structural conditions. Use a cushioned limit stay or install a door stop.

( ) = TS 93 5 – 7

( ) = TS 93 5 – 7

TS 93 GB

Page 10: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

10

DORMA G 93 EMF Slide channel assembly

30

37,5

465

428

120°

80°

= Door stop

Hold-open range

The DORMA G 93 EMF slidechannel assembly enablesthe door to be held opensecurely at a preselectedposition without fall-back.The hold-open point can beadjusted within an openingangle of approx. 80° and120°.NoteThe active leaf can be opened up to the maximumselected hold-open point(door stop to be positionedaccordingly).

In the event of an alarm or a fault in the power supply,the hold-open is releasedand the door is closed bythe door closer. The releaseis triggered by a signal fromexternal smoke detectors(e.g. DORMA RMZ-K/S orDORMA RM). The release force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure thatthe door can also be easilyreleased manually.

The DORMA G 93 EMF slidechannel assembly comprisesthe slide arm, slide channel,slide block, electro-mechan-ical hold-open unit, cover,fixing screws and end caps.The DORMA G 93 EMF is transom-fixed and non-handed.

In the case of particularlylarge and heavy doors (over1250 mm), or doors inwhich the hold-open pointrequired exceeds 120°, werecommend that DORMA EMhold-open magnets in conjunction with theDORMA RMZ-K/S centralsmoke detector be employedinstead of the electro-mechanical hold-open unit.

Operating voltage 24 vDC, ± 15%

Power input 1.4 W

Rated for continuous duty (100%)

Release force adjustable

The DORMA TS 93 EMF hasbeen successfully type-testedto EN 1155, ElectricallyPowered Hold-Open Devices.Certificates are available onrequest.

10

Ø 8 (24 V DC)

138 428

1608

14284(80)

434

max. 16

6516

42

Ø 8 (24 V DC)

10

138

81

2843

max. 26

1730

49(45)

107

43

160

428

DORMA TS 93 B closer with DORMA G 93 EMF slide channel assembly, pull-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.

DORMA TS 93 G closer with DORMA G 93 EMF slide channel assembly, push-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.

TS 93 GB

F Approval certificationTechnical data

Electro-mechanical hold-open

( ) = TS 93 5 – 7

( ) = TS 93 5 – 7

Page 11: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

11

DORMA TS 93 ... door closer(see pages 6 and 7) G 93EMF slide channel assembly,with integrated 24 vDC electro-mechanical hold-open,tested to EN 1155. Hold-open point (80° – 120°) andrelease force adjustable.

ColourY silver Y dark brownwhite,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

Make DORMA TS 93 EMF

TS93EMF/2-5TS93G/EMF/2-5

Hold-open system on a fireand smoke door, comprising:DORMA TS 93 B door closer,DORMA G 93 EMF slidechannel assembly, DORMARMZ-K (smoke sensor, release switching unit andstabilised power pack for 24 vDC) as frame-mountedsmoke detector, plus oneDORMA RM smoke detectoron both sides of the door.(See also page 22.)

230 VACRMZ-K

RM

G 93 EMF

TS 93

RMZ-KRMZ-KRMZ-KRM

EMFRMHTRM

= 2 x 0,5 mm2

= 3 x 0,5 m= 2 x 0,5 m= 3 x 0,5 m

RMRM

HTNC C NO

RMZ-K

9 9

12

32

151418 k

5 12

77

3

5

897106

14

25

41

151418 k

24V AC

230 V AC ± 10%

G 93 EMF

TS 93 (B/G )nnnn

m2

m2

m2

Ω Ω

18 k Ω9

11111

2

TS 93 GB

Specification text Example application

Regulations/Information

The use of hold-open devices may be subject tocertain conditions – see page 27.

Junction boxby others

10 A fuseby others

Page 12: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

The DORMA G 93 EMR slidechannel assembly enables fireand smoke doors to be heldopen securely at precisely theangle required, and monitoredand controlled completelyindependently of othersystems. The hold-open pointcan be adjusted to openingangles between approx. 80°and 120°.NoteThe active leaf can be openedup to the maximum selected

hold-open point (door stop tobe positioned accordingly). In the event of an alarm or a fault in the power supply,the hold-open is releasedand the door is closed bythe door closer. The release force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure thatthe door can also be easilyreleased manually.

The DORMA G 93 EMR slidechannel assembly comprisesthe slide arm, slide channel,slide block, electro-mechan-ical hold-open unit, smokedetector, power pack, cover,fixing screws and end caps.The DORMA G 93 EMR isnon-handed and is availableas an Easy-action or Standardmodel.Both models offer the optionof fitting additional detectors(RMZ-S – only available as a two-wire system). An additional manual releasemechanism can be fitted tothe Easy-action model, anda volt-free changeover contactis also optionally available.In the case of particularlylarge and heavy doors (over1250 mm), or doors in

which the hold-open pointrequired exceeds 120°, werecommend that DORMA EMhold-open magnets beemployed instead of theelectro-mechanical hold-open unit, in conjunctionwith the DORMA RMZ-K/Sframe-mounted smokedetector.

12

DORMA G 93 EMR Slide channel

30

45

141

771

428

202

120°

80°

= Door stop

Hold-open range

Power supply 230 vAC, ± 10%

Operating voltage (internal) 24 vDC

Max. output rating 4.4 W

Rated for continuous duty 100%

Release torque/force adjustable

The DORMA TS 93 EMRhas been successfully type-tested to EN 1155,Electrically Powered Hold-Open Devices.Certificates are available onrequest.

130

Ø10 (230 V AC)

max. 16

42

6516

443

142

84(80)

8

160

428

Ø 10 (230 V AC)

130max. 16

4328

81

428

49(45)

10716043

1730

DORMA TS 93 B closer with DORMA G 93 EMR slide channel assembly, pull-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.

DORMA TS 93 G door closer with DORMA G 93 EMR slide channel assembly, push-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.

TS 93 GB

F Approval certification

Technical data

( ) = TS 93 5 – 7

( ) = TS 93 5 – 7

Electro-mechanical hold-open and integral smoke detector

Page 13: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

13

DORMA TS 93 ... door closer(see pages 6 and 7) G 93EMR slide channel assembly,with integrated electro-mechanical hold-open(tested to EN 1155), powerpack, smoke detector andone-piece cover. Hold-openpoint (80° – 120°) andrelease force adjustable. Power supply 230 vAC Operating voltage 24 vDCColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )ModelY Easy-action model with

optional fitting of additional detectors,external manual releaseand volt-free alarmcontact.Make DORMA TS 93EMR-K

Y Standard model withoptional fitting of twoadditional two-wire detectorsMake DORMA TS 93EMR-S

Hold-open system on a fireand smoke door, comprising:DORMA TS 93 B door closer,DORMA G 93 EMR slidechannel assembly, plus oneDORMA RM smoke detectoron both sides of the door.(See also page 22.)

230 V A C

RM

G 93 EMR

TS 93

G 93 EMR-KG 93 EMR-KRM

RMHTRM

= 3 x 0,5 m= 2 x 0,5 m= 3 x 0,5 m

RMRM

18 k Ω

151418 k Ω

5

3

5

151418 k Ω

230 V AC ± 10%

TS 93 (B/G )

24V

AC G 93 EMR-K

9

7

41

HT

CNC NO

10 6798 14

52

12

32

m2nnn

m2

m2

9

11111

2

7

TS93EMR/K/2-5TS93EMR/S/2-5TS93EMR/K/G/2-5TS93EMR/S/G/2-5

TS 93 GB

Regulations/Information

Example applicationSpecification text

The use of hold-open devicesmay be subject to certainconditions – see page 27.

Junction boxby others

10 A fuseby others

Page 14: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

14

DORMA G 93 GSR Door co-ordinatorslide channel

The DORMA G 93 GSR slidechannel with integral doorco-ordinator for double doorsensures that the active leaf always closes after theinactive leaf.

A slide channel with an integral door co-ordinator ofthis system design alwaysconsists of an active leafslide channel, an inactiveleaf slide channel and a setof covers.

Active leaf Inactive leaf

The DORMA G 93 GSR doorco-ordinator slide channelfeatures a push rod clampingsystem. As this system operates independently ofthe door closer hydraulics, itoffers maximum safety andreliability (doors preventedfrom "creeping closed"). An overload release protectsboth the door co-ordinator andthe door set from damage.The DORMA G 93 GSR doorco-ordinator is non-handedand can be combined with DORMA TS 93 B doorclosers.

Inactive leafActive leaf

The DORMA TS 93 GSR has been successfully type-tested to EN 1158, Door Co-ordinator Devices.Certificates are available on request.

DORMA TS 93 B door closer(see page 6) with G 93 GSRslide channel, with integralmechanical door co-ordinatoremploying a push rod clamping system with over-load release which operatesindependently of the closerhydraulics. With single coverextending over the top ofboth door leaves.

ColourY silver Y dark brownwhite,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

Make DORMA TS 93 GSR

TS93GSR/2-5TS93GSR/5-7

TS 93 GB

For pull-side fixing

Specification textDORMA G 93 GSR

F Approval certification

Page 15: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

15

DORMA G 93 GSR-EMF Door co-ordinatorslide channel

These door co-ordinators not only ensure the correctclosing sequence of doubledoors, but also allow the doorleaves to be individually heldopen in various combinationsdepending on the slidechannel type employed (see page 16).In the event of an alarm or afault in the power supply,

the hold-open is releasedand the door is closed bythe door closer. The releaseis triggered by a signal fromexternal smoke detectors(e.g. DORMA RMZ-K/S orDORMA RM). The release force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure that

the door can also be effort-lessly released manually.DORMA G 93 GSR-EMFdoor co-ordinator slide channels are non-handedand are combined withDORMA TS 93 B door closers.

This door co-ordinator containsjust one hold-open mechanism,located in the inactive leaf slidechannel, for holding open bothdoor leaves. The single-pointhold-open position is adjustablebetween approx. 80° and 130°.Note The active leaf can beopened up to the maximumselected hold-open point (doorstop to be positioned accord-ingly). The active leaf can be heldopen by the door co-ordinator atany angle up to max. 150°.

With this door co-ordinator,the active leaf can be heldopen independently of theinactive leaf. The hold-openpoints for each leaf lie bet-ween approx. 80° and 130°. Note The active leaf can beopened up to the maximumselected hold-open point(door stop to be positionedaccordingly).

This door co-ordinator enablesthe active leaf to be held openindependently in special doorsets involving, for example,fixed side screens, narrowinactive leaves ("penny farthing" doors), etc. Thehold-open point lies betweenapprox. 80° and 130°.Note The active leaf can beopened up to the maximumselected hold-open point (door stop to be positionedaccordingly).

The DORMA TS 93 GSR-EMF 1, EMF 2 and EMF 1Ghave been successfully type-tested to EN 1155,Electrically Powered Hold-Open Devices.Certificates are available onrequest.

DORMA TS 93 B door closer(see page 6) with G 93 GSRslide channel, with integralmechanical door co-ordinatoremploying a push rod clamping system with over-load release, which operatesindependently of the closerhydraulics. With single coverextending over the top ofboth door leaves.

EMF 1Y With integrated electro-mechanical hold-open forthe inactive leaf, 24 vDC,tested to EN 1155. Hold-open point (80° – 130°) andrelease force adjustable.MakeDORMA TS 93 GSR-EMF 1

TS93GSR-EMF1/2-5

EMF 2Y With integrated electro-mechanical hold-open forboth leaves, 24 vDC, testedto EN 1155. Hold-openpoint (80° – 130°) andrelease force adjustable.MakeDORMA TS 93 GSR-EMF 2

TS93GSR-EMF2/2-5

EMF 1GY With integrated electro-mechanical hold-open forthe active leaf, 24 vDC,tested to EN 1155. Hold-open point (80° – 130°) andrelease force adjustable.MakeDORMA TS 93 GSR-EMF 1G

TS93GSR-EMF1G/2-5

Inactive leafActive leaf

= Door stop

approx.150°

approx. 80°

approx. 130°

Inactive leafActive leaf

= Door stop

approx. 80°

approx. 80°

approx. 130°

approx. 130°

Inactive leafActive leaf

= Door stop

approx. 80°

approx.130°

Operating voltage 24 vDC ± 15%

Power input 1.4 W (GSR EMF 2 = 2.8 W)

Rated for continuous duty 100%

Release torque/force adjustable

In the case of doors in which the hold-open point requiredexceeds 130°, we recommend that DORMA EM hold-openmagnets be employed instead of the electro-mechanicalhold-open unit.

ColourY silver Y dark brownwhite,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

TS 93 GB

With integral electro-mechanical hold-open, for pull-side fixing

DORMA G 93 GSR-EMF 1G

DORMA G 93 GSR-EMF 2

DORMA G 93 GSR-EMF 1

F Approval certification Technical data

Specification text

Page 16: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

16

DORMA G 93 GSRDORMA G 93 GSR-EMF

Components and combinations

max. 16

30

42

1665

37,5

84(80)

142 160

470

B

115

G 93 SR-G Slide channel for active leaf with connection for hold-open

G 93 SR-S Slide channel for inactive leaf

G 93 SR-G/OSlide channel for active leaf without connection for hold-open

G 93 SR-S/EMF Slide channel for inactive leaf with electro-mechanical hold-open

G 93 SR-G/EMF Slide channel for active leaf with electro-mechanical hold-open

G 93 SR-V (VK/VL)Cover setwith slide arms and connection tube

Active leaf

( ) = TS 93 5 – 7

TS 93 GB

Page 17: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

17

Ø 8

470

84(80)

142160

B

4

43

A

A DORMA G 93 GSR door co-ordinator slide channel generally comprisesthe following: Active leaf slide channel, inactive leaf slide channel andcover set with slide arms and connection tube.

GSR 1220 – 1350 2 – 5 G 93 SR-VK2)G 93 SR-G/0Door co-ordinator 1350 – 2500 2 – 5 G 93 SR-VG 93 SR-S

2500 – 3200 5 – 7 G 93 SR-VLGSR-EMF 1 1220 – 1350 2 – 5 G 93 SR-VK2)

G 93 SR-GDoor co-ordinator and 1350 – 2500 2 – 5 G 93 SR-VG 93 SR-S/EMFhold-open of the inactive leaf

2500 – 32003) 5 – 7 G 93 SR-VLGSR-EMF 2 1220 – 1350 2 – 5 G 93 SR-VK2)

G 93 SR-G/EMFDoor co-ordinator and 1350 – 2500 2 – 5 G 93 SR-VG 93 SR-S/EMFhold-open of both leaves

2500 – 32003) 5 – 7 G 93 SR-VLGSR-EMF 1G 1220 – 1350 2 – 5 G 93 SR-VK2)

G 93 SR-G/EMFDoor co-ordinator and 1350 – 2500 2 – 5 G 93 SR-VG 93 SR-Shold-open of the active leaf

2500 – 32003) 5 – 7 G 93 SR-VL

1) The covers should be cut to length on site where they meet in the middle, to suit the door size.2) With short slide arms, 320 mm long.3) In the case of particularly large and heavy doors (over 2500 mm), we recommend that DORMA EM hold-open magnets

be employed instead of the electro-mechanical hold-open unit.

Power supply (for EMF only)24 vDC from smoke detector,e.g. DORMA RMZ-K/S

Fixing dimension BB (mm) Door width A (mm)88 1220 – 135034 more than 1350

Inactive leafIn the case of unequal leaves,minimum width 370 mm

TS 93 GB

Model/Function Door width A (mm) TS 93 Closer size Cover set1) Slide channels

Regulations/Information

The use of hold-open devicesmay be subject to certainconditions – see page 27.

Page 18: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

18

DORMA G 93 GSR/BG Door co-ordinator slide channel

The DORMA G 93 GSR/BGslide channel with integraldoor co-ordinator for doubledoors ensures that the activeleaf always closes after theinactive leaf (max. door open-ing angle 120°; door stop tobe positioned accordingly).

A slide channel with an integral door co-ordinator ofthis system design alwaysconsists of an active leafslide channel, an inactiveleaf slide channel and a setof covers.

Not suitable for emergencyexit doors which are openedat the inactive leaf.

Inactive leaf Active leaf

The DORMA G 93 GSR/BGdoor co-ordinator slide channel features a push rodclamping system. As thissystem operates indepen-dently of the door closerhydraulics, it offers maximumsafety and reliability (doorsprevented from "creepingclosed"). An overload releaseprotects both the door co-ordinator and the doorset from damage. TheDORMA TS 93 GSR/BG is ahanded system with ISO 5and ISO 6 models, and canbe combined with TS 93 Gdoor closers.

Inactive leaf Active leaf

approx. 120°

= Door stop

approx. 120°

The DORMA TS 93 GSR/BGhas been successfully type-tested to EN 1158,Door Co-ordinator Devices.Certificates are available on request.

DORMA TS 93 G door closer(see page 7) with G 93GSR/BG slide channel, withintegral mechanical door co-ordinator employing apush rod clamping systemwith overload release, whichoperates independently ofthe closer hydraulics. Withsingle cover extending overthe top of both door leaves.For push-side fixing.

ColourY silver Y dark brownwhite,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

MakeDORMA TS 93 GSR/BG

TS93GSR/BG/2-5

TS 93 GB

For push-side fixing

DORMA G 93 GSR/BG Specification text

F Approval certification

Page 19: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

19

DORMA G 93 GSR-EMF/BG

Door co-ordinatorslide channel

These door co-ordinators notonly ensure the correct closing sequence of doubledoors, but also allow thedoor leaves to be individuallyheld open in various combinations depending onthe slide channel typeemployed (see page 20).In the event of an alarm or a

fault in the power supply,the hold-open is releasedand the door is closed bythe door closer. The releaseis triggered by a signal fromexternal smoke detectors(e.g. DORMA RMZ-K/S orDORMA RM). The release force for thehold-open mechanism can

be adjusted without toolsand is rated to ensure thatthe door can also be effort-lessly released manually.DORMA G 93 GSR-EMF/BGdoor co-ordinator slide channels are non-handedand are combined withDORMA TS 93 G door closers.

This door co-ordinator containsjust one hold-open mechanism,located in the inactive leafslide channel, for holding openboth door leaves. The single-point hold-open position isadjustable between approx.80° and 120°.Note The active leaf can beopened up to the maximum selected hold-open point (doorstop to be positioned accordingly).The active leaf can be held openby the door co-ordinator at anyangle up to max. 120°.

With this door co-ordinator,the active leaf can be heldopen independently of theinactive leaf. The hold-openpoints for each leaf lie bet-ween approx. 80° and 120°. Note The active leaf can beopened up to the maximumselected hold-open point(door stop to be positionedaccordingly).

This door co-ordinator enablesthe active leaf to be held openindependently in special doorsets involving, for example,fixed side screens, narrowinactive leaves (asymmetricaldouble doors), etc. The hold-open point lies betweenapprox. 80° and 120°. Note The active leaf can beopened up to the maximumselected hold-open point (door stop to be positionedaccordingly).

The DORMA TS 93 GSR-EMF1/BG, EMF 2/BG and EMF1G/BG have been success-fully type-tested to EN 1155,Electrically Powered Hold-Open Devices.Certificates are available onrequest.

DORMA TS 93 G door closer(see page 7) with G 93GSR/BG slide channel, withintegral mechanical door co-ordinator employing a pushrod clamping system withoverload release, which operates independently of thecloser hydraulics. With singlecover extending over the topof both door leaves. For push-side fixing.

EMF 1/BGY With integrated electro-mechanical hold-open forthe inactive leaf, 24 vDC,tested to EN 1155. Hold-open point (80° – 120°) andrelease force adjustable. MakeDORMA TS 93 GSR-EMF 1/BG

TS93GSR-EMF1/BG/2-5

EMF 2/BGY With integrated electro-mechanical hold-open forboth leaves, 24 vDC, testedto EN 1155. Hold-openpoint (80° – 120°) andrelease force adjustable. MakeDORMA TS 93 GSR-EMF 2/BG

TS93GSR-EMF2/BG/2-5

EMF 1G/BGY With integrated electro-mechanical hold-open forthe active leaf, 24 vDC,tested to EN 1155. Hold-open point (80° – 120°) andrelease force adjustable.MakeDORMA TS 93 GSR-EMF 1G/BG

TS93GSR-EMF1G/BG/2-5

Inactive leaf Active leaf

approx.120°

= Door stop

approx.80°

approx.120°

Inactive leaf Active leaf

approx. 120°

= Door stop

approx. 80°

approx. 80°

approx. 120°

Inactive leaf Active leaf

approx. 120°

= Door stop

approx. 80°

approx. 120°

Operating voltage 24 vDC ± 15%

Power input 1.4 W (GSR EMF 2/BG = 2.8 W)

Rated for continuous duty 100%

Release torque/force adjustable

TS 93 GB

With integral electro-mechanical hold-open, for push-side fixing

DORMA G 93 GSR-EMF 1G/BG

DORMA G 93 GSR-EMF 2/BG

DORMA G 93 GSR-EMF 1/BG

F Approval certification Technical data

Specification text

ColourY silver Y dark brown white,like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

Page 20: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

20

DORMA G 93 GSR/BGDORMA G 93 GSR-EMF/BG

Components and combinations

max. 5*

30

4328

81

37,5

49(45)

123

160107

470

max. 90

G 93 SR-S/EMF/BGSlide channel for inactive leaf with electro-mechanical hold-open

G 93 SR-S/BGSlide channel for inactive leaf

G 93 SR-G Slide channel for active leaf with connection for hold-open

G 93 SR-G/OSlide channel for active leaf without connection for hold-open

G 93 SR-G/EMF/BGSlide channel for active leaf with electro-mechanical hold-open

G 93 SR-V/BGCover setwith slide arms and connection tube

Inactive leafMinimum width 600 mmwith unequal leaves

*Use angle bracket for larger reveal depths

TS 93 GB

Page 21: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

21

Ø 8 30

17

176

118(114)

115

160

470 165

A

Active leaf

( ) = TS 93 5 – 7

TS 93 GB

Power supply (for EMF only)24 vDC from smoke detector, e.g. DORMA RMZ-K/S

A DORMA G 93 GSR/BG door co-ordinator slide channel generally comprisesthe following: Active leaf slide channel, inactive leaf slide channel and coverset with slide arms and connection tube.

GSR/BGG 93 SR-G/0Door co-ordinator 1500 – 2500 2 – 5 G 93 SR-V/BGG 93 SR-S/BG

GSR-EMF 1/BG*G 93 SR-GDoor co-ordinator and 1500 – 25002) 2 – 5 G 93 SR-V/BGG 93 SR-S/EMF/BGhold-open of the inactive leaf

GSR-EMF 2/BG*G 93 SR-G/EMF/BGDoor co-ordinator and 1500 – 25002) 2 – 5 G 93 SR-V/BGG 93 SR-S/EMF/BGhold-open of both leaves

GSR-EMF 1G/BG*G 93 SR-G/EMF/BGDoor co-ordinator and 1500 – 25002) 2 – 5 G 93 SR-V/BGG 93 SR-S/BGhold-open of the active leaf

1) The covers should be cut to length on site where the ends meet in the middle, to suit the door size.2) In the case of particularly large and heavy doors, we recommend that DORMA EM hold-open magnets be employed

instead of the electro-mechanical hold-open unit.* Planned availability from spring 1999

Model/Function Door width A (mm) TS 93 Closer size Cover set1) Slide channels

Regulations/Information

The use of hold-open devicesmay be subject to certainconditions – see page 27.

Page 22: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

22

DORMA RMZ-K/S, RM Frame and ceiling-mounted smoke detectors

Functions Smoke detector 2 2 2Release device 2 2 2Power supply unit 2 2 –

Smoke Scattered light principledetection (optical sensor) 2 2 2Fixing Frame-mounted 2 2 2

Ceiling-mounted – – 2Connection 2-wire 2 2 2of other smoke switches 2 – 2detectors

Total installed load (max.) Dependsfor hold-open device on powerand other detectors in W 4.4 4.4 supply unit

Power input ofinternal detectors in W 0.5 0.5 0.6

Indicators Alarm – red LED 2 2 2Armed – green LED 2 2 2

Input voltage 230 V AC 230 V AC 24 V DC± 10 % ± 10 % +15%, –10%

Output voltage 24 V DC 24 V DC 24 V DC

Detector operating voltage 24 V DC 24 V DC 24 V DC+15%, –10%

Input current (max.) with externalpower supply unit, in A – – 2

Current input (max.) in mA 111 91 25

Floating Switching voltage (max.) 60 V DC/ 60 V DC/change-over 25 V AC 25 V ACcontact Switching current (max.) 2 A – 2 A

Switching capacity (max.) 60 W 60 W

Automatic reset, 2 2 2can be changed tomanual reset – – 2Test port for functional checking 2 2 2Connection terminalsfor external manual release 2 – 2Degree of protection IP 20 IP 20 IP 20

Ambient temperature in °C –15, +60 –15, +60 –20, +50

Weight in kg 0.6 0.6 0.4

Dimensions Length 336 336 195in mm Overall depth 50 50 53

Height 30 30 52

2 yes – no

For more detailed information, see RMZ/RM brochure

Data and features RMZ-K RMZ-S RMThe DORMA RMZ-K/S frame-mounted smoke detector andthe DORMA RM frame andceiling-mounted smoke detectorprovide the ideal complementto the successful, service-proven DORMA TS 93 rangeof preventive fire protectionproducts. They are designedin accordance with the latestcodes issued by the GermanInstitute for Building Techno-logy, and ensure perfectinteraction between all thedevices employed for holdingopen fire and smoke doors –whatever the situation.

The innovative design ofthese devices has ensured ahigh degree of compactnessso that there are no installa-tion or positioning problems.And their attractive Softlinestyling blends in with anysurroundings.

Frame-mounted smoke detector with stabilised powersupply unit. This detector isavailable as an Enhanced orStandard model.

In the event of an alarm or apower failure, this unit de-energises all the hold-opendevices connected to it (release function).

Designed as a smoke switch;actuates a floating (volt-free)change-over contact in theevent of an alarm or powerfailure. Also suitable as an

add-on smoke detector forthe DORMA TS 73 EMR, TS 93 EMR and RMZ.Tested by VdS Cologne toEN 54, Part 7.

RMZ-K/SSmoke detector for framemounting with integratedpower supply unit and optical smoke sensor. Forrelease of DORMA hold-opendevices. With connectionsfor further smoke detectors.Floating (volt-free) change-over contact and connectionterminals for externalmanual release.Input voltage 230 vACOperating voltage 24 vDCApproved by the Institute for Building Technology in Berlin as a hold-open release device.

ColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

ModelY Enhanced model with

optional connection ofadditional detectors,external manual releaseand floating (volt-free)alarm contact.Make DORMA RMZ-K

Y Standard model withoptional connection ofadditional 2-wire detectors Make DORMA RMZ-S

RMZ-KRMZ-S

RMNon-directional, universaloptical smoke detector (24 vDC) for frame and ceiling installation. Can beemployed as smoke switchand monitoring device forhold-open devices. Withconnections for furthersmoke detectors, floating(volt-free) change-overcontact and connection terminals for externalmanual release.Approved by the Institute for Building Technology,Berlin for general use as ahold-open release deviceand tested by the VdSCologne to EN 54 Part 7.

ColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y stainless steelY polished brassY special colour (like RAL )

RM

304

16

336 30

50

53

52195

170

32

Ø 4,5

TS 93 GB

Specification texts

DORMA RMZ-K/S

DORMA RM

DORMA RMZ-K/S andDORMA RM units have beenapproved by the GermanInstitute for BuildingTechnology, Berlin, as hold-open release devices.

F Approval certification

Page 23: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

23

RMZ-K/S frame-mounted smoke detector on the push sideconnected to a G 93 GSR on the pull side

>1700

RMZ-K/S frame-mounted smoke detector on the pull side connected to a G 93 GSR on the pull side (use mounting bracket)

39354

327

33

Mounting bracket for RMZ-K/S frame-mounted smoke detector

Active leafInactive leaf

Active leaf Inactive leaf

TS 93 GB

Page 24: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

24

Accessories Single doors

5,5

10

5

23

442

428

30

10

5

442

428

40

465

428

5,5

20 33

10

5

5,5

20 33 40

4

32Ø 5,5

15 25

15

257 142

442

142 7

428

4

32Ø 5,5

15 25

26 35

18,5 142

465

142 18,5

428

31

5413

11

EMF

NEM

R

28

23

16

5443

5315

16

4326

64

16

30 mm mounting backplatefor G 93 NFor fixing the slide channelto the door frame wheredirect fixing is not possible.

40 mm mounting backplatefor G 93 N, EMF, EMRFor fixing the slide channelto the door frame wheredirect fixing is not possible.

Angle bracket for G 93 NFor push-side fixing of theslide channel to door frameswith a deep reveal.

Angle bracket for G 93 EMFFor push-side fixing of theslide channel to door frameswith a deep reveal.

TS 93 GB

G 93 N

G 93 EMF/EMR

Page 25: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

25

5

18,5

33

10

20

608

470

40

5,5

5

5,5

33

10

20

1805

327

40

739

5

1155470

23518

45010

33

10

40

26 35

4

32

18

253

1155

18470

253

470

Ø 5,5

15 25

13

4216

6513

16

42 6

5

5423

1628

2643

64

16

40 mm mounting backplatefor G 93 GSRFor fixing the slide channelsto the door frame wheredirect fixing is not possible.

40 mm mounting backplatefor RMZ-K/S base unit inconjunction with a G 93 GSR(also as filler between thetwo G 93 GSR mountingbackplates)

40 mm mounting backplatefor G 93 GSR/BGFor fixing the slide channelsto the door frame wheredirect fixing is not possible.

Angle bracket for G 93 GSR/BGFor fixing the slide channelsto door frames with a deepreveal.

Accessories Double doors

TS 93 GB

Page 26: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

26

Accessories GSR pivot block

If the DORMA GSR door co-ordinator is to operateindependently of the TS 93door closer, for example, in combination with the ED 200 automatic swingdoor operator, the connectionbetween the door co-ordinator and the door leafis provided by means ofGSR pivot blocks.

B

142

122 106

66

53 13 26

470

43

0

43

10

0

42

13

37,5

38,5

133

10

6

65

Fixing dimension BB (mm) Door width (mm)88 1220 – 135034 more than 1350

GSR pivot block for door co-ordinator

DORMA ED 200 automatic swingdoor operator with DORMA G 93 GSR door co-ordinator andGSR pivot block

TS 93 GB

Specification text

F Approval certification

The DORMA GSR door co-ordinator with pivot blockshas been approved by e.g.the State Material TestingAuthority, Dortmund/Germany, for use on doublefire and smoke doors.

Pivot blocks for closer-inde-pendent door co-ordinationwith DORMA G 93 GSR doorco-ordinators.

ColourY silver Y dark brownwhite, like RAL Y 9010 Y 9016Y special colour (like RAL )

MakeDORMA GSR pivot block

GSR

Page 27: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

27TS 93 GB

Hold-open systems Regulations/Information

The use of hold-open devicesmay be subject to certainconditions. These usuallydeal particularly with therelevant acceptance, routineinspection and maintenancerequirements.The information given onthis page is designed toinform all relevant personsof the most important measures to be implementedin order to ensure best practice governing the oper-ation of hold-open systems.

Further details can be foundin the following documents:

– Guidelines for hold-opensystems, published by the German Institute forBuilding Technology,Berlin.

– Building Regulations,England and Wales

– Relevant regulations forScotland and N. Ireland

– EN 1155

1.1 In respect of doors etc.which are held open byhold-open systems, the areaneeded for closure must bekept permanently free ofobstructions. This areashould be clearly indicatedby means of lettering, floor markings or similar. If necessary, structural measures may need to betaken in order to ensure thatwiring/ducting, stored goodsor structural components(e.g. false ceilings or othercomponents) do not falldown into the area to bekept clear.

1.2 As far as possible,smoke detectors should beused for hold-open systems.Smoke detectors should beused for hold-open systemsfor doors etc. in emergencyexits and escape routes.

1.3 All hold-open devicesshould be able to be releasedmanually without their operational readiness beingadversely affected. Door closers with electro-magnetichold-open systems can bereleased by pressing lightlyon the door leaf. If hold-open magnets or free-swingdoor closers are used, therelease function is triggeredby pressing a switch. Theswitch must be located inthe immediate proximity ofthe door and must not becovered when the door isheld open.

2.1 After the system hasbeen fitted ready for use on-site, it should be commissioned to check thatits operation is problem-freeand that its installationcomplies with all relevantregulations. The commission-ing should only be performedby qualified technical personnel.

3.1 The operator shouldkeep the hold-open systemin a permanently fit state for use and must inspect itat least once a month toensure its functional integrity.

3.2 In addition, it is the responsibility of the operatorto ensure that all devices arechecked and maintained/serviced to ensure their combined functional integrity,this to be performed at leastonce a year, unless a shortertime period is stipulated inthe national regulations. Thisinspection and servicingactivity should only be carried out by a specialist orsuitably qualified person.

3.3 The scope, result and time of the routine inspections should be recorded, and these recordsshould be retained by theoperator.

1 General 2 Commissioning 3 Routine inspection

Page 28: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

28

Range of equipment and optional accessories

Single doors

TS 93 B TS 93 G 30 mm mounting 40 mm mountingbackplate backplatefor G 93 N for G 93 N

EN 2 – 5 EN 2 – 5y 120200xx y 120300xx

EN 5 – 7 EN 5 – 7y 125200xx y 125300xx 183400xx 183500xx

TS 93 GB

For specification text/product description, see page 6 7 24 24G 93 N

y y

8 # #Y Y

Y 180100xxG 93 EMF

y y

10Y Y

Y 180300xxG 93 EMR-K

y y

12Y Y

Y 180408xxG 93 EMR-S

y y

12Y Y

Y 180407xx

Page 29: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

24 24 24 8 8

# # #

# #

#

#

40 mm mounting Angle bracket Angle bracket Cushioned Add-onbackplate for for G 93 N for G 93 EMF limit stay set hold-open unitG 93 EMF, EMR for G 93 N for G 93 N

182900xx 183600xx 183000xx 35800093 18260000

29

Also available in matching"Design" finishes:

y = Closer separate

Y = Slide channel assembly separate

# = Optional accessory

Colour x xSilver 01Dark brown 03White (like RAL 9016) 11White (like RAL 9010) 10Special colour 09

Stainless steel 04Polished brass 05

"Design" refers to the surface finish of the products

Smoke detector system

RMZ-K180619xx

RMZ-S180618xx

RM3570xx88

For specification text/product description,see page 22

TS 93 GB

Page 30: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

30

Range of equipment and optional accessories

Double doors

For specification text/product description, see page 6 7 25 25GSR 2x

y

14 #G 93 SR-G/0 G 93 SR-S XX 18400000 X 18430000

GSR-EMF 1 2xy

15 #G 93 SR-G G 93 SR-S/EMF XX 18410000 X 18440000

GSR-EMF 2 2xy

15 #G 93 SR-G/EMF G 93 SR-S/EMF XX 18420000 X 18440000

GSR-EMF 1G 2xy

15 #G 93 SR-G/EMF G 93 SR-S XX 18420000 X 18430000

GSR/BG 2xy

18 #G 93 SR-G/0 G 93 SR-S/BG XX 18400000 X 18170000

GSR-EMF 1/BG 2xy

19 #G 93 SR-G G 93 SR-S/EMF/BG XX 18410000 X 18180000

GSR-EMF 2/BG 2xy

19 #G 93 SR-G/EMF/BG G 93 SR-S/EMF/BG XX 18200000 X 18180000

GSR-EMF 1G/BG 2xy

19 #G 93 SR-G/EMF/BG G 93 SR-S/BG XX 18200000 X 18170000

A door co-ordinator slide channel assembly of this system design TS 93 B TS 93 G Mounting Mountingalways comprises an active leaf slide channel, backplate backplatean inactive leaf slide channel and a set of covers. for GSR for GSR/BG

EN 2 – 5 EN 2 – 5y 120200xx1) y 120300xx1)

EN 5 – 7 EN 5 – 7y 125200xx1) y 125300xx1) 184500xx 183100xx

TS 93 GB

Page 31: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

31

25 23 25 26 8

# #

# #

# #

# #

# # #

#

#

#

Angle bracket RMZ-K/S Mounting back- Pivot block Cushionedfor GSR/BG base unit plate for RMZ-K/S limit stay

base unit

183200xx 180700xx1) 184600xx 3590xx07 18020000

Cover sets with arms

GSR

Door width Cover set Order No.mm1220–1350 G 93 SR-VK2) 182110xx1)

1350–2500 G 93 SR-V 182111xx1)

2500–3200 G 93 SR-VL 182112xx1)

2)With short slide arms, 320 mm long

GSR/BG

Door width Cover set Order No.mm1500–2500 G 93 SR-V/BG 182200xx1)

Smoke detector system

RMZ-K180619xx1)

RMZ-S180618xx1)

RM3570xx881)

For specification text/product description,see page 22

TS 93 GB

1) Also available in matching1 )"Design" finishes:

y = Closer separate

Y = Slide channel assembly separate

# = Optional accessory

Colour x xSilver 01Dark brown 03White (like RAL 9016) 11White (like RAL 9010) 10Special colour 09

Stainless steel 04Polished brass 05

"Design" refers to the surface finish of the products

Page 32: Cam action door closer system DORMA TS 93 · 2008. 10. 17. · DORMA TS 93 Cam action door closer system 4 EN EN Variable closing force Spring strength 2–55–7 Standard doors2)

Subject to change without notice

WN 051 541, 10/00, TS 93, GB, 5. DD/CtP. 11/00

DORMA Door Controls LtdDORMA Trading ParkStaffa RoadGB-London E10 7QXTel. 020 8558 8411Fax 020 8558 6122Email: [email protected]

DORMA Door Controls Ltd19 Sandyford Office ParkFoxrockIRL-Dublin 18Tel. 01 295 8280/1/2Fax 01 295 8584Email: [email protected]

DORMA GmbH + Co. KGPostfach 4009D-58247 EnnepetalTel. +49(0)2333/793-0Fax +49(0)2333/79 34 95