Density, Refractive Index, pH and ColorMultiparameter Analysis

Cosm

etic

s

Page 2: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

2

Mul

tipar

amet

er A

naly

sis

Flexible product approach

A wide range of samples can be measured, from low to high viscous products. Sampling and cleaning cycles and result limits can be programmed individually for each type of sample. At the end of the analysis, sample recovery allows to get the sample back in the vial in order to retain it as a reference sample.

Various samples – several parameters

All analysis results are shown on the instru-ment touch screen. A computer is only re-quired if a large product data base needs to be handled and if data has to be exported to LIMS or ERP. With the client/server software LabX, the computer can be placed away from the system, e.g. in the office of the lab manager.

The fully automatic analysis of samples saves time, increases throughput and avoids data transcription errors. The modularity of the systems allows upgrading of an existing instrument with additional modules to add further measuring parameters to the analysis anytime.The standard solution gives reliable and comparable results, wherever the system is used.

Our Standardsystemneeds no Computer

Page 3: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

3

Our Standardsystemneeds no Computer

www.mt.com/cosmetic-liquiphysics www.konicaminolta.eu

Find more Information:

3

DM45 Density Meter + RX40 Refractive Index Cell + CM-5 Spectrophotometer + SC30 Sample Changer

Partnership Programbetween:

• Density / Specific Gravity• Refractive index• pH• Automation• Software

• Color

Page 4: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

4

DensityThe LiquiPhysics DM density meter is usually the master and controls all other instru-ments, including the automation unit. One click on the selected product or measurement method starts the measurement on all connected instruments. The measurement is done automatically and all results displayed on the touch screen. All measurement data can be analyzed and transferred to a LIMS or ERP system.

Automation The SC1 and SC30 sample delivery and cleaning units completely automate the mea-surement of all parameters, including sampling, rinsing and drying. Using pressurized air allows to measure high viscous samples. There is no evaporation or contamination of the samples. SC1 is for single sample, SC30 for 30 samples.

Refractive IndexLiquiPhysics RX refractive index measuring cells can be connected to the DM density meter to measure refractive index or related values in a multi-parameter system. Benchtop LiquiPhysics RM refractometers are also available for stand-alone measure-ments.

A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the analy-sis. The SC1 sample delivery and cleaning unit and the SC30 sample changer automate the sampling, draining, rinsing and drying.

Measure simultaneously density, refractive index, pH, conductivity and color. The open archi-tecture allows to add further instruments, such as polarimeters. The LabX software allows to easily managing all instruments, users with different profiles, product database, methods and measurement data, with full integration in your IT environment.

From single analysis to a fully automatic multiparameter system

Mod

ular

ity

Density Density + single sample automation Density + refractive index + multi sample automation

Page 5: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

5

pHThe SevenCompact S220 pH/ion meter can be connected to the LiquiPhysics DM density meters or RM refractometers, using a flow cell to measure pH or conductivity.

ColorThe compact bench-top Spectrophotometer Konica Minolta CM-5 can be used either within a multi-parameter system or as stand alone instrument to measure and analyze the color of liquid samples in transmission and solid samples in reflectance. When equipped with a special flow cell, the CM-5 becomes a fully integrated and controlled part for color measurement of liquids within the multi-parameter analysis system.

SoftwareOur LabX software conveniently manages instruments, users, methods, measurement results, system suitability tests and adjustments. Reports can be adapted to specific corporate layout formats. The results of several instruments are stored in the same data-base and can be exported to LIMS or ERP systems. LabX fully supports you with software validation and compliance including 21CFR part 11.

The perfect modular system according to your needs

Density + refractive index + color + pH + multi sample automation + software

Page 6: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

6

Save up to 70% labor timeAll four measurements are done fully automati-cally by just pressing one button or a scan of the barcode. Instead of spending a lot of time for performing measurements and cleanings on each individual instrument, the operator can spend his valuable time for more demanding tasks.

Increase throughput by 50% All parameters are determined simultaneously in all instruments instead of one analysis done after the other. The SC30 sample changer can be loaded with up to 30 samples. A built-in bar code reader identifies each sample and starts the correspond-ing analysis automatically.

The dedicated solution for fully automatic analysis of all parameters helps to increase efficiency and ensures a high data quality. Operator indepen-dent measurements ensure maximum reproducibility and save labor costs.

One Systemfor zero worries

Adva

ntag

es

 

Page 7: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

7

Manage raw materials and final productsA product data base with all raw materials and finished products can be imported from an existing data base into the LabX software. The measure-ment results are automatically compared with the target values and limits stored in the product data base. Fully customized reports or quality certifi-cates can be created with LabX.

No transcription errorsThe whole workflow is done without human inter-action, therefore eliminating transcription errors. The sample is identified by barcode, the corre-sponding measurement method selected accord-ingly, followed by the comparison of the result to the target values. The result “passed/failed” is stored in the database with all the measurement data and can be transferred to a LIMS or ERP sys-tem (e.g. SAP).

Page 8: Density, Refractive Index, pH and Color · A stand-alone instrument can be upgraded anytime with different modules to increase throughput and add further measuring parameters to the

For more informationwww.mt.com/cosmetic-liquiphysics

Mettler-Toledo AG, AnalyticalCH-8603 Schwerzenbach, SchweizTelefon +41-44-806 77 11Fax +41-44-806 73 50

Subject to technical changes© 04/2012 Mettler-Toledo AGPrinted in Switzerland Global MarCom Switzerland

Genral

Min. sample volume per vial 10 mL for measurement of all parameters

Max. sample viscosity 30’000 mPas correspond to viscosity of liquid honey

Typical analysis time per sample 5 min for analysis of four parameters (density, RI, pH, color) including complete cleaning and drying of the whole system, for samples around 20’000 mPas (e.g. edible oil).

Density DM40 DM45 DM50

Measurement range [g/cm3] 0.0000 … 3.00000 0.00000 … 3.00000 0.00000 … 3.00000

Repeatability [g/cm3] 0.00005 0.000005 0.000005

Limit of error [g/cm3] 0.0001 0.00002 1) 0.00002 3)

0.00005 2) 0.00004 4)

Refractometry RX40 RX50

Measurement range [nD] 1.3200 ... 1.7000 1.32000 ... 1.58000

Repeatability [nD] 0.00005 0.00001

Limit of error [nD] 0.0001 0.00002

pH S220

Measurement range [pH] –2.000 … 20.000

Resolution 0.001 / 0.01 / 0.1

Accuracy ± 0.002

Color 5) CM-5 CR-5

Wavelength range [nm] 360 –740 Tri-Stimulus-Meter

Wavelength pitch [nm] 10 -

Repeatability, spectral [%] 0.1 [400 –740 nm] -

Repeatability, colorimetric [dE*] 0.04 0.04

1) 0.7 … 1 g/cm3, 15 … 20 °C 2) 0 … 3 g/cm3, 0 … 91°C 3) 0 … 1 g/cm3 4) 0 … 3 g/cm3 5) Provided by Konica Minolta

Technical Specifications for multiparameter system