53
4/8/2019 2019 Copyright © American Wood Council. All rights reserved. 1 CLT Stands Up A Look at Cross-laminated Timber Wall Design (DES442) Lori Koch, P.E. Manager, Educational Outreach American Wood Council Michelle Kam-Biron, P.E., S.E., S.E.C.B Senior Director, Education American Wood Council Photo courtesy of LendLease CLT Stands Up 2 This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of AWC is prohibited. © American Wood Council 2019 COPYRIGHT

CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 1

CLT Stands UpA Look at Cross-laminated Timber Wall Design (DES442)

Lori Koch, P.E.Manager, Educational OutreachAmerican Wood Council

Michelle Kam-Biron, P.E., S.E., S.E.C.BSenior Director, EducationAmerican Wood Council

Photo courtesy of LendLease

C LT S t a n d s U p 2

This presentation is protected by US and International Copyright laws. Reproduction,

distribution, display and use of the presentation without written permission of

AWC is prohibited.

© American Wood Council 2019

COPYRIGHT

Page 2: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 2

C LT S t a n d s U p 3

DESCRIPTION

Even before cross-laminated timber (CLT) was recognized in the 2015 IBC, there wasgrowing interest to use it in the US by designers seeking a sustainable constructionproduct, with a reduced on-site construction time, all while exploiting the naturalbeauty of wood to provide a pleasing environment to occupants. Not only does CLTmeet all of these attributes, but it also provides excellent thermal separation and canbe designed to provide up to two hours of fire resistance and even more whenprotected. This presentation will provide a step-by-step design example of CLT usedin a wall application to resist gravity loads as well as design for exposure to fire perthe 2018 National Design Specification® (NDS®) for Wood Construction and AWC’sTR-10 – Calculating the Fire Resistance of Wood Members and Assemblies.

C LT S t a n d s U p 4

LEARNING OBJECTIVES

1. Discuss relevant CLT product manufacturing and design standards and identify where these standards are referenced in the IBC.

2. Describe how to design CLT walls for gravity loads.

3. Design a CLT wall for fire resistance and thermal separation.

4. Discuss existing state of in-plane CLT shear wall design provisions.

Page 3: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 3

C LT S t a n d s U p 5

POLLING QUESTION

1. What is your profession?

a. Architect

b. Engineer

c. Code Official

d. Fire Service

e. Builder/Manufacturer/Other

C LT S t a n d s U p 6

POLLING QUESTION

2. Where are you located given the map below?

a. West  (purple)

b. North Central (green)

c. Northeast (brown)

d. Southeast (teal)

e. South Central (yellow)

West (purple)

North Central (green)

Northeast (brown)

Southeast (teal)

South Central (mustard)

Page 4: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 4

C LT S t a n d s U p 7

POLLING QUESTION

3. How familiar are you with CLT?

a) Guru – designed or plan reviewed many CLT projects and can teach this course. 

b) Craftsman – designed or plan reviewed many projects with CLT. 

c) Apprentice – familiar with CLT but no design/review of projects. 

d) Novice – just started learning about CLT 

e) CLT whaaat?

C LT S t a n d s U p 8

OUTLINE

CLT Building ExamplesCLT – IBC, NDS, ANSI/APA PRG-320

CLT Wall Structural & Fire Design Example

Resources

Page 5: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 5

C LT S t a n d s U p 9

LIGHT WOOD FRAME CONSTRUCTION

C LT S t a n d s U p 1 0

UNITED KINGDOM – MASS TIMBER CONSTRUCTION

Developer: Telford HomesArchitect Waugh ThistletonGeneral Contractor lford HomesStructural Engineer Techniker Ltd

The StadthausHackney, London, U.K.• 9 Stories (8 over 1)• Mixed use • Completed Jan. 2009

Page 6: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 6

C LT S t a n d s U p 1 1

CANADIAN PROJECTS – MASS TIMBER

Brock Commons -Tallest MassTimber Structure in North AmericaVancouver, British Columbia, Canada• 18 Stories (17 over 1)

• Mixed use student housing

• Completed Sept. 2017

Owner/Developer: University of British ColumbiaArchitect Acton Ostry Architects, Inc.General Contractor Centura Building Systems Ltd.

Seagate Structures LtdStructural Engineer Fast+Epp

C LT S t a n d s U p 1 2

CANADIAN PROJECTS

Photo courtesy of Seagate Structures

Page 7: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 7

C LT S t a n d s U p 1 3

CANADIAN PROJECTS – MASS TIMBER

The ArboraQuébec, Canada• (3) 8 Stories• 434 Residential condo, townhouse

and rental units

Developer: LSR GesDev and SotramontArchitect Lemay+CHAStructural Engineer Nordic Structures

C LT S t a n d s U p 1 4

CANADIAN PROJECTS – MASS TIMBER

Page 8: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 8

C LT S t a n d s U p 1 5

CANADIAN PROJECTS – MASS TIMBER

The Arbora

C LT S t a n d s U p 1 6

CANADIAN PROJECTS – MASS TIMBER

OrigineQuébec, Canada• 12 over 1Stories• 92 Unit Residential condo

Developer: NEB GroupContractor: EBCArchitect: Yvan Blouin ArchitectEngineer: Groupe conseil SID Inc.Mass Timber Source: Nordic StructuresCompleted 2017

Page 9: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 9

C LT S t a n d s U p 1 7

CANADIAN PROJECTS – MASS TIMBER

Source: Nordic Structures

C LT S t a n d s U p 1 8

CANADIAN PROJECTS – MASS TIMBER

Source: Nordic Structures

Page 10: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 10

C LT S t a n d s U p 1 9��������� ������

Elementary School, Franklin, West Virginia – completed 2015

US PROJECTS – MASS TIMBER

Owner: Pendleton County School DistrictArchitect MSES Architects General Contractor City Construction Company

Seagate Structures LtdStructural Engineer MSES Consultants, Inc.

Clayton L. Carter Professional Engineer, Inc.

C LT S t a n d s U p 2 0Four stories 58,000 sq ftArchitect: Lend Lease

Source: Lend Lease

Private Army HotelRedstone Arsenal Huntsville, ALCompleted 2016

US PROJECTS – MASS TIMBER

Owner: Pendleton County School DistrictArchitect MSES Architects General Contractor City Construction Company

Seagate Structures LtdStructural Engineer MSES Consultants, Inc.

Clayton L. Carter Professional Engineer, Inc.

Page 11: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 11

C LT S t a n d s U p 2 1

US PROJECTS – MASS TIMBER

Albina YardPortland, Oregon4 Story

Office, Retail

16,000SF

Completed Summer 2016

Client/Owner: Albina Yard LLCArchitect Lever ArchitectureGeneral Contractor ReworksStructural Engineer KPFF Consulting Engineers

C LT S t a n d s U p 2 2

US PROJECTS – MASS TIMBER

Page 12: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 12

C LT S t a n d s U p 2 3

US PROJECTS – MASS TIMBER

Carbon 12Portland, Oregon8 Story (85 feet)

Condominiums/ commercial

42,000SF

Completed Summer 2018

Developer: Ben KaiserArchitect: PATH ArchitectureGeneral Contractor: Kaiser Group Inc.Structural Engineer: DCI Engineers

C LT S t a n d s U p 2 4

US PROJECTS – MASS TIMBER

����������� ���� �

Page 13: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 13

C LT S t a n d s U p 2 5

OUTLINE

CLT Building ExamplesCLT – IBC, NDS, ANSI/APA PRG-320CLT Wall Structural & Fire Design

Example

Resources

C LT S t a n d s U p 2 6

BUILDING CODE

Page 14: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 14

C LT S t a n d s U p 2 7

CROSS-LAMINATED TIMBER (CLT)

Photo provided by FPInnovations

C LT S t a n d s U p 2 8

MASS TIMBER CONCEPT - HISTORY OF CLT

1985 1st CLT patent - France

1993 1st CLT projects - Switzerland and Germany

1995-1996 Improved press technology

1998 1st multi-story res building - Austria

Early 2000’s• CLT use (Europe) increased significantly

• Green building movement driven

• Better efficiencies, product approvals, improved marketing and distribution channels

• Over 500 CLT buildings in England

Recent - US and Canadian use of CLT

Page 15: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 15

C LT S t a n d s U p 2 9

CLT VS GLULAM

Beam-like member Thick Orthotropic Plate

Graphics provided by WoodWorksGraphics provided by APA

Cross-Laminated TimberGlued Laminated Timber

C LT S t a n d s U p 3 0

BENDING MEMBERS – FLATWISE

• Design properties for out-of-plane (flatwise) loading – tabulated in PRG320• ASD bending moment (FbS)eff,f

• Average bending stiffness (EI)eff,f

• ASD shear capacity (Vs) • Average shear stiffness (GA)eff,f

Figure courtesy of APA (PRG320-18)

Page 16: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 16

C LT S t a n d s U p 3 1

BENDING MEMBERS – EDGEWISE

• Properties for in-plane (edgewise) bending require qualification testing per PRG320• ASD bending moment (Fb,eSe)• Average bending stiffness (EeIe)• ASD shear capacity (Fv,etp)• Average shear stiffness (Getp)

Figure courtesy of APA (PRG 320-18)

C LT S t a n d s U p 3 2

TYPICAL CLT PANEL CONNECTORS

Page 17: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 17

C LT S t a n d s U p 3 3

TYPICAL CLT PANEL CONNECTORS

C LT S t a n d s U p 3 4

CLT - TYPICAL CONSTRUCTION DETAILS

Single surface spline

Half-lapped

Page 18: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 18

C LT S t a n d s U p 3 5

http://www.awc.org/Code-Officials/2012-IBC-Challenges/#

http://www.awc.org/Code-Officials/2012-IBC-Challenges/Preliminary-CLT-Fire-Test-Report-FINAL-July2012.pdf

FIRE TESTS

C LT S t a n d s U p 3 6

FIRE TEST

American Wood CouncilASTM E119 Fire Endurance Test• 5-Ply CLT (approx. 7” thick)• 5/8” Type X GWB each side• Sought 2 hour rating• RESULTS: 3 hours 6 minutes

Half-lapped – middle of panel (vertical)

Page 19: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 19

C LT S t a n d s U p 3 7

WHERE IS CLT ALLOWED IN IBC 2018?

Type IV Construction

2015 IBC 2018 IBC

NEW: CLT and SCL

C LT S t a n d s U p 3 8

WHERE IS CLT ALLOWED IN IBC 2018?

Relocated from Ch. 6

Page 20: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 20

C LT S t a n d s U p 3 9

TYPE IV CONSTRUCTION

All structural elements can be CLT• Exterior walls – 6” total (actual)

• FRTW or gypsum protection

• Floor – 4” (actual)

• Roof – 3” (actual)

• Interior walls – 4” (actual)

NLT structural elements• Floor – 4” (nominal) on edge

• Roof – 3” (nominal) on edge

C LT S t a n d s U p 4 0

WHERE IS CLT ALLOWED IN IBC 2018?

Type III Construction

602.3 Type III. Type III construction is that type ofconstruction in which the exterior walls are ofnoncombustible materials and the interior buildingelements are of any material permitted by this code.Fire-retardant-treated wood framing and sheathingcomplying with Section 2303.2 shall be permittedwithin exterior wall assemblies of a 2-hour rating orless.

Page 21: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 21

C LT S t a n d s U p 4 1

• So where could CLT go?• Almost anywhere!

• Interior – any material permitted by code

• Roof

• Exterior Walls need to be non-combustible or FRT Wood (2 hour or less)

TYPE III CONSTRUCTION

CLT/NLT - Roof

CLT/NLT - Floor

CLT – Interior walls

C LT S t a n d s U p 4 2

WHERE IS CLT ALLOWED IN IBC 2018?

Type V Construction

602.5 Type V. Type V construction is that type of construction in which the structural elements, exterior walls and interior walls are of any materials permitted by this code.

Page 22: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 22

C LT S t a n d s U p 4 3

TYPE V CONSTRUCTION

ALL structural elements can be CLT/NLT• Exterior walls• Floor• Roof• Interior walls

C LT S t a n d s U p 4 4

POLLING QUESTION

4. Which of the following is the tallest mass timber structure in North America?

a) The Stadthaus

b) Brock Commons 

c) The Arbora

d) Origine

Page 23: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 23

C LT S t a n d s U p 4 5

GOVERNING CODES FOR WOOD DESIGN

2018 IBC references 2018 NDS

C LT S t a n d s U p 4 6

2018 NDS

Product Chapters

• Ch. 4 Sawn Lumber

• Ch. 5 Structural Glued Laminated Timber

• Ch. 8 Structural Composite Lumber

• Ch. 10 Cross-Laminated Timber

Page 24: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 24

C LT S t a n d s U p 4 7

CROSS-LAMINATED TIMBER

C LT S t a n d s U p 4 8

CHAPTER 10 – CROSS-LAMINATED TIMBER

New

Page 25: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 25

C LT S t a n d s U p 4 9

CLT MANUFACTURING STANDARDS

• 2018 IBC references ANSI/APA PRG 320-2017

• Applicable to current low- and mid-rise buildings using CLT

• Types III, IV, and V

2017

C LT S t a n d s U p 5 0

CLT MANUFACTURING STANDARDS

• 2021 IBC references ANSI/ APA PRG 320-2018

• Applicable to all CLT construction• Types III, IV-HT, and V• Types IV-A, IV-B, and IV-C

• Tall mass timber

2018

Page 26: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 26

C LT S t a n d s U p 5 1

PRODUCT MARKING

Marks contain the following

a) CLT layup qualified

b) CLT thickness or identification

c) Mill name or identification number

d) Approved agency name or logo

e) Reference product standard “ANSI/APA PRG 320”

f) “Top” stamped on top face (only for unbalanced layup)

320-2017

C LT S t a n d s U p 5 2

CHAPTER 10 – CROSS-LAMINATED TIMBERSingle or multiple

surface layers1, 2, 3, 4 transverse layers

Graphics provided by FPInnovations

Laminations: 5/8”-2” sawn lumber or SCL Panel thickness: 20” maxIn-Service MC: 16%

Page 27: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 27

C LT S t a n d s U p 5 3

CHAPTER 10 – CROSS-LAMINATED TIMBER

C LT S t a n d s U p 5 4

CLT PRODUCT REPORTS

https://www.apawood.org/cross-laminated-timber

Page 28: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 28

C LT S t a n d s U p 5 5

CLT PRODUCT REPORTS

C LT S t a n d s U p 5 6

CHAPTER 10 – CROSS-LAMINATED TIMBER

Page 29: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 29

C LT S t a n d s U p 5 7

NDS – CHAPTER 12

Includes CLTConnections

C LT S t a n d s U p 5 8

SEISMIC DESIGN OPTIONS

ASCE 7 Minimum Design Loads for Buildings and Other StructuresResponse Modification Coefficient, R

CLT not recognized system in ASCE 7 Table 12.2-1Options• Performance-based design procedure per ASCE 7• Demonstrating equivalence to an existing ASCE 7 system• ASCE 7-16, FEMA P695, and FEMA P795 Quantification of

Building Seismic Performance Factors; Component Equivalency Methodology

• Use a system prescribed in ASCE 7

Page 30: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 30

C LT S t a n d s U p 5 9

IN-PLANE SHEAR FOR LATERAL LOADS

• No ASCE 7 R-value (earliest possible ASCE 7-22/2024 IBC)

• No standardized shear-through-thickness values (in-plane shear)

• No published standard design method• All present designs by alternative methods & materials

• SDPWS 2021 being balloted now

• Design procedures per manufacturer’s specs• Based on tested assemblies

• Not all manufacturers have design values/procedures

• Approval by alternate methods and materials

C LT S t a n d s U p 6 0

NDS CHAPTER 16 – FIRE (ASD)

• Fire resistance up to two hours• Columns• Beams • Tension Members• ASD only

• Products• Lumber• GLT• SCL• Decking• CLT

Page 31: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 31

C LT S t a n d s U p 6 1

HEAVY TIMBER FIRE RESISTANCE RATING

Photo by Structure Magazine

C LT S t a n d s U p 6 2

FIRE PERFORMANCE GLULAM VS. STEEL

Page 32: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 32

C LT S t a n d s U p 6 3

NDS CHAPTER 16 – CALCULATED RESISTANCE

Fire resistance of exposed wood members may be calculated using the provisions of NDS Chapter 16

Predictable

C LT S t a n d s U p 6 4

2018 NDS METHODOLOGY

NDS Chapter 16 – Fire Design of Wood Members• Mechanics Based Model

• Supported by empirical data

• NLT, Glulam & CLT

Page 33: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 33

C LT S t a n d s U p 6 5

FIRE DESIGN OF EXPOSED WOOD MEMBERS

Allowable Stress Design

C LT S t a n d s U p 6 6

Technical Report No. 10• Background on NDS provisions• Design examples• CLT provisions

FIRE DESIGN OF EXPOSED WOOD MEMBERS

Page 34: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 34

C LT S t a n d s U p 6 7

NDS CHAPTER 16 – CALCULATED RESISTANCE

Cross-laminated Timber – Effective Char Depth

Revised

C LT S t a n d s U p 6 8

NDS CHAPTER 16 – CALCULATED RESISTANCE

CLT manufactured with laminations of equal thickness

Page 35: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 35

C LT S t a n d s U p 6 9

NDS CHAPTER 16 – CALCULATED RESISTANCE

Structural Fire

Design

C LT S t a n d s U p 7 0

NDS CHAPTER 16 – CALCULATED RESISTANCE

Page 36: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 36

C LT S t a n d s U p 7 1

NDS CHAPTER 16 – CALCULATED RESISTANCE

• Char rate and char depth• Modified char depth model• Step-wise approach

C LT S t a n d s U p 7 2

FIRE DESIGN OF EXPOSED WOOD MEMBERS

Char layer

Heated zone

Cross-section used for calculating capacity

Fire

Exp

osur

e

Page 37: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 37

C LT S t a n d s U p 7 3

CALCULATED FIRE RESISTANCE?

Net section properties

Plan

Typical one foot section

Section

C LT S t a n d s U p 7 4

POLLING QUESTION

5. The following information may be found on a CLT product mark:

a) Panel layupb) Panel thickness, width and lengthc) Mill Named) Grade of laminationse) a. and c.

Page 38: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 38

C LT S t a n d s U p 7 5

OUTLINE

CLT Building ExamplesCLT – IBC, NDS, ANSI/APA PRG-320

CLT Wall Structural & Fire Design Example

Resources

C LT S t a n d s U p 7 6

COMBINED BENDING AND AXIAL LOADING

A 10 ft CLT wall supports the following loads:

Dead load = 7500 plf (includes estimated self weight)

Live load = 15000 plf

Wind load = 25 psf

Design the wall using properties from PRG 320-18

Page 39: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 39

C LT S t a n d s U p 7 7

COMBINED BENDING AND AXIAL LOADING

Select 3-ply CLT panel (each ply = 1-3/8”, total thickness = 4-1/8”) CLT grade E1 tabulated properties:

Fc0 = 1800 Reference compression stress, psi

FbSeff,f,0 = 4525 Reference bending moment, ft-lb/ft of width

EIeff,f,0 = 115x106 Reference bending stiffness, psi/ft of width

GAeff,f,0 = 0.46x106 Reference shear stiffness, lb/ft of width

C LT S t a n d s U p 7 8

CLT MANUFACTURING STANDARD

Page 40: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 40

C LT S t a n d s U p 7 9

TR-10 CLT WALL DESIGN EXAMPLE

See CLT manufacturer or ER for design valuesAssume for this ex. PRG 320-18 design values

Excerpt from PRG 320-18 Table A2

C LT S t a n d s U p 8 0

CLT MANUFACTURING STANDARDCLT Layups

Page 41: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 41

C LT S t a n d s U p 8 1

COMBINED BENDING AND AXIAL LOADING

Effective Wall Compression Capacity

Area parallel to grain is 2 plies @ 1-3/8” thick

Aparallel = 2*(1.375”)*12” = 33 in2 per foot of wall

Pc = Fc0 * Aparallel = 59,400 lb per foot of wall

C LT S t a n d s U p 8 2

COMBINED BENDING AND AXIAL LOADING

Effective Wall Buckling Capacity

Use NDS Eqn. 10.4-1; Ks = 11.8 (pin-pin supports)

psi/ft of wall

Adjusted Buckling Capacity

EIappmin = 0.518EIapp = 49 *106 psi/ft of wall (NDS C10.4.1)

Page 42: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 42

C LT S t a n d s U p 8 3

COMBINED BENDING AND AXIAL LOADING

Adjusted Compression Capacity

Live and dead loads only, so CD = 1.0 (all other adjustment factors = 1.0)PcE = 2 * (EIappmin/L2) = 34 x 103 lb/ft of wall

Pc* = Pc * CD * CM * Ct = 59.4 x 103 lb/ft of wall c = PcE / Pc* = 0.57

P’c = Pc* (CP) = 30.6 x 103 lb/ft of wall

C LT S t a n d s U p 8 4

COMBINED BENDING AND AXIAL LOADING

Adjusted Bending Capacity

Moment is due to applied wind load (CD = 1.6)

M = (wwind * L2)/8 = 312.5 ft-lb/ft of wall

CL = 1.0 (d<b)

Fb’Seff0 = FbSeff0 * CD * CM * CL * Ct = 7240 ft-lb/ft of wall

Page 43: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 43

C LT S t a n d s U p 8 5

COMBINED BENDING AND AXIAL LOADING

Combined Capacity

Interaction check, Combined demand must be < 1.0

C LT S t a n d s U p 8 6

NDS-CLT DESIGN

Page 44: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 44

C LT S t a n d s U p 8 7

TR-10 CLT WALL DESIGN EXAMPLE

Given (cont.):Adjustment factors:

Load duration factor CD = 1.0

Moisture factor CM = 1.0

Temperature factor Ct = 1.0

Calculate axial panel load (per foot of width):

Pload = (Pdead + Plive) = (6,150 plf + 14,000 plf )(1ft width) = 20,150 lf/ft of panel width

C LT S t a n d s U p 8 8

• From PRG 320-18 select 7-ply CLT floor panel made from 13/8in. x 31/2 in. lumber boards (CLT thickness of 95/8 in.)

TR-10 CLT WALL DESIGN EXAMPLE

10’-0”

9 5/8”

NA

Structural Check• Calculate the effective wall compression capacity

Aparallel = bd of strong axis plies = 4(12)(1.375)

= 66 in2/ft of width (NDS 10.3.1)

Pc = Fc,0 Aparallel = (1800)(66) = 118,800 lb/ft of width

Page 45: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 45

C LT S t a n d s U p 8 9

TR-10 CLT WALL DESIGN EXAMPLEStructural Check (cont.)• Calculate the apparent wall buckling capacity:

NDS Equation 10.4-1, with PRG-320 assumption E/G = 16

For pinned-pinned column buckling, Ks = 11.5; therefore:

EI1,089 x10

1 11.8 1,089 x10

1.4 x10 120 2

EIEIeff

1 Ks

EIeffGAeff

L2

= 665 x 106 lbs-in.2/ft. of width

Using NDS Appendix H and the COV = 0.10 from PRG-320:

(EI)app-min = (665x106)(1-1.645(0.10))(1.03)/1.66 = 345x106 lb/in2/ft of width (NDS 10.3.1)

C LT S t a n d s U p 9 0

TR-10 CLT WALL DESIGN EXAMPLE

Structural Check (cont.)• Calculate the adjusted allowable column capacity:

(EI)app-min' = (EI)app-min (CM)(Ct) = 345x106(1.0)(1.0) = 345x106 lb/in2/ft of width (NDS 10.3.1)

Using the general form of the Euler buckling equation:

P*c = Pc (CD)(CM)(Ct) = 118,800 (1.0)(1.0)(1.0) = 118,800 lb/ft. of width (NDS C3.7.1.5)

Use c = 0.9 for CLT (NDS C3.7.1.5)

c = PcE / P*c = 236,500/118,800 = 1.991

(NDS C3.7.1.5)

P’s = P*c Cp = 118,800 (0.9208) = 109,400 lb/ft of width

Structural Check: P’s = Pload 109,400 lb/ft > 20,150 lb/ft

𝑃𝜋 𝐸𝐼 𝑎𝑝𝑝 𝑚𝑖𝑛

𝐿2= 236,500 lb/ft. of width (NDS C3.7.1.5)

𝜋 345𝑥10 𝑎𝑝𝑝 𝑚𝑖𝑛

120 2

Page 46: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 46

C LT S t a n d s U p 9 1

TR-10 CLT WALL DESIGN EXAMPLE

Fire Check:Mass loss due to charring is conservatively maximum induced moment is unchanged.

Aeff 3.8 inches

The wall can be designed as an eccentrically-loaded 3-ply CLT column.

C LT S t a n d s U p 9 2

TR-10 CLT WALL DESIGN EXAMPLE

Typical one foot section

NA

10’-0”

9 5/8”

NATypical one foot section

NA

Fire Check (cont.)

Page 47: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 47

C LT S t a n d s U p 9 3

From PRG 320, select a 3-ply CLT panel made from the same 1-3/8 in x 3-1/2 in. lumber boards (CLT thickness of 4-1/8 inches) and the same CLT grade E1. The tabulated properties are:

Reference compression stress, (Fc,0) = 1800 psi (Table A1)

Reference bending moment, (FbS)eff,f,0= 4,545 lbf-ft/ft of width(Table A2)

Reference bending stiffness, (EI) eff,f,0= 115 x 106 lbf-in.2/ft of width (Table A2)

Reference shear stiffness, (GA) eff,f,0= 0.46 x 106 lbf/ft of width (Table A2)

Calculate the effective wall compression capacity:

Aparallel = bd of strong axis plies = 2(12)(1.375) = 33 in2/ft of width (NDS 10.3.1)

Pc = Fc,0 Aparallel = (1800)(33) = 59,400 lb/ft of width (NDS 10.3.1)

TR-10 CLT WALL DESIGN EXAMPLE

C LT S t a n d s U p 9 4

Calculate the apparent wall buckling capacity

(EI)app-min = (95.4x106)(1-1.645(0.10))(1.03)/1.66

= 49.5x106 lb/in2/ft of width (NDS 10.3.1)

Calculate the adjusted allowable column capacity (assuming CD=N/A: CM=N/A: Ct=N/A):

(EI)’app-min = 49.5x106 lb/in2/ft of width (NDS 10.3.1)

TR-10 CLT WALL DESIGN EXAMPLE

Fire Check (cont.)

EI115 x 106

1 11.8 115 x100.46 x10 120 2

= 95.4 x 106 lbs-in.2/ft. of width

Page 48: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 48

C LT S t a n d s U p 9 5

Calculate the adjusted allowable column capacity (cont.)

Using the general form of the Euler buckling equation:

P*c,f = 2.58Pc = 2.58(59,400) = 153,300 lb/ft. of width (NDS C3.7.1.5)

Use c = 0.9 for CLT

c = PcE,f / P*c,f = 68,900 / 153,300 = 0.4494

(NDS C3.7.1.5)

P’f = P*c Cp = 153,300 (0.4192) = 64,250 lb/ft of width

Fire Check: P’f = Pload 64,2500 lb/ft > 20,150 lb/ft

TR-10 CLT WALL DESIGN EXAMPLE

Fire Check (cont.)

𝑃 , 2.03𝜋 𝐸𝐼 𝑎𝑝𝑝 𝑚𝑖𝑛

𝐿2= 68,900 lb/ft. of width (NDS C3.7.15)2.03

𝜋 49.5 𝑥 10 𝑎𝑝𝑝 𝑚𝑖𝑛

1202

C LT S t a n d s U p 9 6

Eccentricitye = (d7-ply-d3-ply)/2 = (9.625-4.125)/2 = 2.75”

resisting moment (assuming CD=N/A: CM=N/A: Ct=N/A: CL=1.0)

Mf′ = (2.85) Fb(Seff)( CL) = 2.85(4,525)(1.0)

= 12,900 ft-lb/ft of width (NDS 16.2.2)

TR-10 CLT WALL DESIGN EXAMPLE

Fire Check (cont.)

Page 49: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 49

C LT S t a n d s U p 9 7

Based on NDS Equation 15.4-3:

Fire Check:

TR-10 CLT WALL DESIGN EXAMPLE

Fire Check (cont.)

C LT S t a n d s U p 9 8

TR-10 CLT WALL DESIGN EXAMPLE

Fire Check (cont.)

Page 50: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 50

C LT S t a n d s U p 9 9

TR-10 CLT WALL DESIGN EXAMPLE

Thermal SeparationASTM E119 average temp increase on unexposed surface < 250°F Estimated time to burn-through, tbt, is calculated using TR10 Section 4.4.1.1:

(TR10 4.4.1.1)

tts =0.85 tbt = 0.85 (562) = 478 minutes (TR10 4.4.1.2)

Thermal Separation Check: tts > FRR 478 minutes > 120 minutes

𝑡 60 .

.

.+ 17 = 60 . .

.

.+17 = 562 minutes

C LT S t a n d s U p 1 0 0

POLLING QUESTION

6. Which of the following is true for CLT wall systems?

a) Manufacturer or code ER provide ref. design valuesb) The deflection criteria in the IBC is the same as the

NDSc) Exposed CLT may be designed for 2 hrs. of fire-

resistance d) All of the above e) a) and c)

Page 51: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 51

C LT S t a n d s U p 1 0 1

OUTLINE

CLT Building ExamplesCLT – IBC, NDS, ANSI/APA PRG-320

CLT Wall Structural & Fire Design Example

Resources

C LT S t a n d s U p 1 0 2

RESOURCES

www.awc.org• Print versions

• PDF versions

Page 52: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 52

C LT S t a n d s U p 1 0 3

RESOURCES

E-courses

2018 NDS Changes - National Design Specification® for Wood Construction (STD120)

Taking Wood to the Next Level – CLT as a Floor or Roof Element (DES441-1)

Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion (DES605 )

http://awc.org/education/ecourses

C LT S t a n d s U p 1 0 4

RESOURCES

Structure Magazine2018 NDS

2018 WFCM

2015 SDPWS

www.awc.org

Page 53: CLT Stands Up · • Types III, IV, and V 2017 CLT Stands Up 50 CLT MANUFACTURING STANDARDS • 2021 IBC references ANSI/ APA PRG 320-2018 • Applicable to all CLT construction •

4/8/2019

2019 Copyright © American Wood Council. All rights reserved. 53